| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹15.7 L | L1 | Accepted-AOC Accepted being lowest bidder |
| 2 | L2₹17.0 LRejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹17.0 L | L2 | Rejected-AOC Rejected not being lowest bidder |
| 3 | L3₹18.1 LRejected-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹18.1 L | L3 | Rejected-AOC Rejected not being lowest bidder |
| 4 | L4₹22.1 LRejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹22.1 L | L4 | Rejected-AOC Rejected not being lowest bidder |
| Sl No | Description | Qty | Unit | K S BUILDERS L1 | MAMTA ENTERPRISES L2 | M/SHansrajbuilder L3 | DAVINDER SINGH L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for taking down and lifting up high mast light fitting including replacing the unserviceable items to make the fitting serviceable ,serving, greasing of steel re opened adjust/repair the timer, supply and fixing in replacement the contacts lifting mechanism with all accessories as required complete all as directed by the Engineer-in-Charge.(Note :- Drivers & LED fitting will be measured and paid separately) | 1 | Each Job | 11,006 ₹11,006 | 3,000 ₹3,000 | 900 ₹900 | 10,000 ₹10,000 |
| 2.00 | Dismantling and taking down the existing defective street light/flood light/Post top Lantern fitting of any type and any capacity fixed at any height complete all as directed by Engr-in-Charge. | 198 | Each | 6 ₹1,188 | 200 ₹39,600 | 3 ₹594 | 25 ₹4,950 |
| 3.00 | Supply and fixing LED street light fitting 90 Watt 230 Volt output 10800 LM AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple modular Secondary lens optics complete with IP 65/66 protection with 50000 burning Hrs complete all as directed.
Note: Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad | 50 | Each | 3,206 ₹1.6 L | 2,600 ₹1.3 L | 3,600 ₹1.8 L | 2,550 ₹1.3 L |
| 4.00 | Supply and fixing LED street light fitting 70/72 Watt 230 Volt AC output 9100 LM outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple modular Secondary lens optics complete with IP 65/66 protection with 50000 burning Hrs complete all as directed.
Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad | 50 | Each | 2,906 ₹1.5 L | 2,200 ₹1.1 L | 3,400 ₹1.7 L | 2,100 ₹1.1 L |
| 5.00 | Supply and fixing LED flood light 120 watt 230 Volt AC output 9600 LM outdoor type with thermal management in multiple modular Secondary lens optics and equipped with IP66 protection with 50000 burning Hrs, with impact and corrosion resistant complete with driver and lamp complete all as directed.
Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad | 20 | Each | 3,626 ₹72,520 | 3,200 ₹64,000 | 3,800 ₹76,000 | 3,000 ₹60,000 |
| 6.00 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC output 4000 LM outdoor type with decorative post top for 360 degree indirect light IP 65 protection with 50000 burning Hrs impact and corrosion resistant complete with driver and lamp complete all as directed.
Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad | 30 | Each | 3,806 ₹1.1 L | 3,600 ₹1.1 L | 4,600 ₹1.4 L | 4,200 ₹1.3 L |
| 7.00 | Supply and fixing post top lantern LED type 20/25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with 50000 burning Hrs with impact and corrosion resistant complete with driver and lamp complete all as directed.
Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad | 30 | Each | 3,106 ₹93,180 | 2,600 ₹78,000 | 2,600 ₹78,000 | 3,400 ₹1.0 L |
| 8.00 | Supply and fix in replacement of water proof electric distribution box( 3 Phase, 4 Wire), wheather proof IP-65 protection suitable for outdoor use, pole mounted, factory made of size 300mm x 250mm x 150mm comprising one No. MCB SP 6 Amps, 240 volts SPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 3mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts and washers made of galvanized iron and connection thimble etc. complete all as specified and directed. | 10 | Each | 1,806 ₹18,060 | 2,000 ₹20,000 | 1,400 ₹14,000 | 1,200 ₹12,000 |
| 9.00 | Supply and fixing of Junction box made out of thermo plastic material of size 240x130x110 mm with provision of single phase cable connector incomming and out going with MCB SP 6-32 amps for security light fitting/PTL IP 65 protection totally enclosed weather proof with cable entry along with GI clamps nut bolts & washer fixed on pole including dismantling/taking out old unserviceale one all as directed. | 15 | Each | 1,806 ₹27,090 | 700 ₹10,500 | 900 ₹13,500 | 1,000 ₹15,000 |
| 10.00 | Supply and fixing Street light/Flood light fitting electronic constant current drivers/PCB/electronic gear suitable for 70 to 120 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed . | 24 | Each | 206 ₹4,944 | 350 ₹8,400 | 700 ₹16,800 | 400 ₹9,600 |
Updated dates
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Nov 2025, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
REPAIR MAINTENANCE REPLACEMENT OF PATHWAY LIGHTS PARAMETER SECURITY LIGHTS HIGH MAST LIGHTS INCLUDING CONNECTED WORKS AT 15 FAD JINDRAH UNDER GE ARMY DHAR ROAD
2025_MES_737287_1
8071/NIT-62/2025-26
Open Tender
Civil Works
180 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹50,000
Yes
16 Jan 2026
28 Oct 2025
27 Nov 2025
29 Oct 2025
25 Nov 2025
12 Nov 2025
Amount
Labour only for taking down and lifting up high mast light fitting including replacing the unserviceable items to make the fitting serviceable ,serving, greasing of steel re opened adjust/repair the timer, supply and fixing in replacement the contacts lifting mechanism with all accessories as required complete all as directed by the Engineer-in-Charge.(Note :- Drivers & LED fitting will be measured and paid separately)
Dismantling and taking down the existing defective street light/flood light/Post top Lantern fitting of any type and any capacity fixed at any height complete all as directed by Engr-in-Charge.
Supply and fixing LED street light fitting 90 Watt 230 Volt output 10800 LM AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple modular Secondary lens optics complete with IP 65/66 protection with 50000 burning Hrs complete all as directed. Note: Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad
Supply and fixing LED street light fitting 70/72 Watt 230 Volt AC output 9100 LM outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple modular Secondary lens optics complete with IP 65/66 protection with 50000 burning Hrs complete all as directed. Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad
Supply and fixing LED flood light 120 watt 230 Volt AC output 9600 LM outdoor type with thermal management in multiple modular Secondary lens optics and equipped with IP66 protection with 50000 burning Hrs, with impact and corrosion resistant complete with driver and lamp complete all as directed. Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC output 4000 LM outdoor type with decorative post top for 360 degree indirect light IP 65 protection with 50000 burning Hrs impact and corrosion resistant complete with driver and lamp complete all as directed. Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad
Supply and fixing post top lantern LED type 20/25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with 50000 burning Hrs with impact and corrosion resistant complete with driver and lamp complete all as directed. Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad
Supply and fix in replacement of water proof electric distribution box( 3 Phase, 4 Wire), wheather proof IP-65 protection suitable for outdoor use, pole mounted, factory made of size 300mm x 250mm x 150mm comprising one No. MCB SP 6 Amps, 240 volts SPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 3mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts and washers made of galvanized iron and connection thimble etc. complete all as specified and directed.
Supply and fixing of Junction box made out of thermo plastic material of size 240x130x110 mm with provision of single phase cable connector incomming and out going with MCB SP 6-32 amps for security light fitting/PTL IP 65 protection totally enclosed weather proof with cable entry along with GI clamps nut bolts & washer fixed on pole including dismantling/taking out old unserviceale one all as directed.
Supply and fixing Street light/Flood light fitting electronic constant current drivers/PCB/electronic gear suitable for 70 to 120 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed .
Supply and fix in replacement of security light fitting bracket made up of 25/32 mm dia medium grade pipe of length 0.9 mtr with bending in shape by hot or cold method with 2 nos 50x4 mm MS flate clamps with nut bolts and washer etc all as directed
Excavation in trenches n.exc 1.5 mtr wide and exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been errected and tested , all as specified.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
M & L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm with width equal to length complete all as specified and directed by Engr-in-Charge
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 63 mm outer dia and 50 mm inner dia all as directed.
Taking out existing worn out/old PVC insulated cable in 4/2 core of 25 sqmm to 10 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 25 Sqmm 4 core with required aluminium cable lugs all as specified and directed.
All as per item no. 21 above but size 16 sq mm 4 core
All as per item no. 21 above but size 10 sq mm 2 core
Supply and laying or fixing or passing through pipe from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 10 Sqmm 2 core (TC) nominal cross section incl taking down old one complete all as directed.
All as per item no. 24 above but size 06 sq mm 2 core
Meterial and labour for cement concrete in foundations for pole or any other work type D2 1:4:8 with 40 mm graded crushed stone aggregate all as directed.
Meterial and labour for cement concrete in foundations for pole or any other work type C2 1:3:6 with 40 mm gradedcrushed stone aggregate all as directed
Meterial and labour for cement concrete in foundations for pole coping or any other work type B1 1:2:4 with 20mm graded crushed stone aggregate all as directed
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply & fixing in replacement of Busbar chamber 200 Amps, TPN 8 way minimum length 460mm long enclosed in sheet metal enclosure with and including 04 No's of angle iron legs length 1.2 made out of 50mmx50mmx6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system including consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade including all the fixing arrangements, making all incoming and out going connections through the lugs/thimbles all as specified and directed .Note: PCC item will be measured and paid separately.
S&F MCCB 125 Amps 4 Pole, 16 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 160 Amps 3 Pole, 36 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers and earth lead protected by 15mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth lead wire and protection pipe beyond 7.5m shall be measured and paid separately.
Supply and fixing of Steel tubular swaged poles type 410 SP-31 (9.0 meter long) complete with cast iron base plate, finial taper plug, bolts, nuts & screws etc including making the holes on the pole (bottom and top) suitable size for drawing of wire 1.5 sqmm 3 core round flexible for connection of security light fitting from junction box to light fittings including of one primer coat, one under coat and one finishing coat of silver paint all as specified and directed.
Supply and fixing in replacement of LED flood light 200 watt, 230 Volt AC output 24000 LM outdoor type with thermal management in multiple Secondary lens optics and equipped with IP 66 protection with 50000 burning Hrs, with impact and corrosion resistant complete with driver and lamp complete all as directed. Note:Product authentication and warranty to be provided by the company representative of the concerned company on OEM letter head pad
S&F in replacement of High Mast head suitable for existing High Mast light complete all as specified.
S&F in replacement of High Mast light decorative bracket circular type suitable for existing High Mast light that holds the light fixtures with all including nuts, bolts and washer etc complete all as specified and directed.
S&F in replacement of High Mast light steel wire rope suitable for existing High Mast light for raise and lower the lantern carriage complete all as specified and directed.
S&F in replacement of motor suitable for existing High Mast light to operate the winch system complete all as specified and directed.
S&F in replacement Automatic control panel for High Mast light of existing type complete all as specified and directed
S&F in replacement of trailing cable for connection of existing High Mast light fittings complete all as specified and directed
S&F in replacement of junction box suitable for existing High Mast light complete all as specified and directed.
S&F in replacement of Reverse forward switch suitable for existing High Mast light to controls the direction of motor complete all as specified and directed.
M&L in replacement of Winch stand (bracket) suitable for existing High Mast light to controls the direction of motor complete all as specified and directed.
M&L in replacement of High Mast lighting pole suitable of existing type/Make of High Mast light complete all as specified and directed.
Deduct Schedule of Credit of Rs. (-) 35363.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
MAMTA ENTERPRISES (BID ID -3477410)
M/SHansrajbuilder (BID ID -3476653)
DAVINDER SINGH (BID ID -3481815)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.34 MB
Tender Documents
Tender Documents • 1.54 MB
BOQ
BOQ • 0.69 MB
Download all tender documents and submit your bid