Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.6 LAccepted-Finance | ₹71.6 L | L1 | Accepted-Finance OK |
| 2 | L2₹78.9 L+₹7.3 L (10.2%)Accepted-Finance 5A 24 ANSARI ROAD DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | ₹78.9 L+₹7.3 L (10.2%) | L2 | Accepted-Finance OK |
| 3 | L3₹79.8 L+₹8.2 L (11.5%)Accepted-Finance 21 10 SHOP NO 1 SECTOR 3 MAHABINI DELHI 110085 | NORTH WEST | DELHI | 110085 | ₹79.8 L+₹8.2 L (11.5%) | L3 | Accepted-Finance OK |
| 4 | L4₹82.1 L+₹10.5 L (14.6%)Accepted-Finance 2ND FLOOR 208 D BLOCK AJNARA COMPLEX VIVEK VIHAR DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹82.1 L+₹10.5 L (14.6%) | L4 | Accepted-Finance OK |
| 5 | L5₹82.8 L+₹11.2 L (15.7%)Accepted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹82.8 L+₹11.2 L (15.7%) | L5 | Accepted-Finance OK |
Tender Value
₹1.3 Cr
Closing Date
23 Oct 2021, 3:00 pmClosed
EE(E)
North Electrical Division (M-352), Dr. BSA Hospital, Sector-6, Rohini, Delhi-85
SH Replacement of existing conventional HPSV MH fittings into energy efficient LED ic cabling work at Model Town to Mukarba Chowk under North Electrical Division PWD Delhi
2021_PWD_209739_1
30/NED/PWD/M352/2021-22
Open Tender
Electrical Works
Item Rate
60 days
as per NIT
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
11 Nov 2021
14 Oct 2021
23 Oct 2021
14 Oct 2021
23 Oct 2021
14 Oct 2021
Amount
Supplying, installation, testing & commissioning of LED street light fixture with IP 66 & IK 07 protection pressure aluminium die cast housing capable of delivering following nominal system lumens output with a minimum system efficacy more than 130 lumens /watt and a CRI greater than 70 . The luminaire shall have a life class of 50000 hours @L70 for a design ambient of 35 deg C . The inbuilt electronic driver shall operate at power factor > .95 of CCT 4000-5700K minimum internal surge protection of 4 KV with toughened glass /polycarbonates cover. The fitting shall be install on existing 10-12 mtrs GI pole with arrangement to fix on existing GI bracket. LM 79/80 certification to be provided by the manufacturer for LED luminaire /LED chip .complete etc . as reqd. (a) Not less than 28000 Lumen
(b) Not less than 21000 Lumen
Supplying, installation, testing & commissioning of following watts aluminium body, IP66 LED flood light fitting with lens & toughened glass capable of delivering following nominal system lumens output with a minimum system efficacy more than 115 lumens /watt and a CRI greater than 70 . The luminaire shall have a life class of 50000 hours @L70 for a design ambient of 35 deg C . The inbuilt electronic driver shall operate at power factor > .95 of CCT 5700K minimum internal surge protection of 4 KV with toughened glass /polycarbonates cover LM 79/80 certification to be provided by the manufacturer for LED luminaire /LED chip .complete with all accessories i/c making connections, testing & arrangement for fixing on existing bracket i/c dismantling the existing fitting if any etc. complete with all accessories etc. directly on all type of high mast pole as required. (a) Not Less than 16500 Lumen
(b) Not less than 22000 Lumen
Supplying and drawing following sizes of PVC/XLPE insulated (heavy duty) Aluminium conductor Armoured power cable of 1100 V grade conforming to IS:1554 (PART-I) 1988/ 7098 (Part – I) in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd. (a) 3 core 4 sq.mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing boring by trenchless technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer-in-charge with moling equipment i/c jointing cleaning, rodding of pipe providing suitable covers on mouth of pipes, excavation of pits of required size at a following depth i/c refilling etc. complete as reqd. 2 Mtr to 2.5 Mtr. depth.
Cutting RCC / Bituminous road (30 cm deep) with the help of Road reaper / cutting machine suitable i/c laying of GI pipe 65 mm medium B Class nominal i/c supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required and making good the same.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Upto 35 sq. mm
Providing, grouting & fixing 25 mm X 5 mm G.I. strip on surface or in recess or direct in ground for earth connections etc. as required.
ACE ENGINEERS BUREAU
R S ELECTRIC CO.
Goel electric works
Shaka Electrical (India)
SONA ENGINEERS
AJAY MC TOOLS
KALSI ENGINEERS
RAMESH ELECTRIC WORKS
SM ELECTROTECH PRIVATE LIMITED
A K Electric Works
Rajesh Electrical Works
Neev Energy LLP
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .