Tender Value
₹57.3 L
EMD Value
₹1.1 L
Closing Date
19 Jun 2026, 11:00 am5d left
Executive Engineer (E),
Executive Engineer (E),PWD NES/M-251, LM Bund Road, Ramesh Park, Delhi
(SH- Providing day to day routine maintenance of electrical work, Mechanical work, Lift Operation and CCTV Operation)
2026_PWD_293424_1
37/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
365 days
M-2533
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.1 L
Yes
13 Jun 2026
13 Jun 2026
19 Jun 2026
13 Jun 2026
19 Jun 2026
13 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Sub Head I CDMO Shahdara | |||||
| 1.1 | Providing services of the qualified and experienced staff for attending day to day Electrical complaints i/c maintenance of electrical installation such as ceiling fan, exhaust fan, tube light fitting, lamp holder, electrical main board i/c repairing and cleaning of all the electrical fans tube light fitting, main boards, sub-distribution board, earthing compound light etc. in all working days excluding Sunday and Holiday in General shift in 9:00 AM to 5:00 PM at office of the Chief District Medical officer Shahdara, Directorate of Health services GNCT of Delhi, Working Women Hostel Jhilmil, Delhi – 110095.
Wireman – 1 No.
Khallasi – 1 No. | - | Months | - | - |
| 2Sub Head II JJB, Vishwas Nagar | |||||
| 2.1 | Maintenance of Electrical Installations & Fans i/c EDB's main boards, rising mains, exit sign boards, security lights and compound lights and Operation of 125 KVA capacity DG set with AMF panel from 9 AM to 5 PM on all days excluding Sunday & Gazetted holidays i/c cleaning & routine testing of equipment’s etc. complete as required.
Wireman cum Operator: - 1 No.
Khallasi :- 1 No. | - | Months | - | - |
| 3Round the clock operation and maintenance of wet-riser/sprinkler, firefighting system, AFA/PAS installed at various places/floors along with panel, water supply pump sets drainage pumps etc. i/c cleaning of panels on all days excluding Sundays & Gazetted holidays complete as required. Operator: - 3 Nos. | |||||
| 4Operation of 1 No. 4 passengers’ capacity, Judges lift and 1 No. 8 Passenger capacity, common lift (both lifts Johnson Make) from 9 AM to 5 PM on all days excluding Sunday & Gazetted holidays i/c cleaning of lift cars etc. complete as required. Lift Operator: - 2 Nos. | |||||
| 5Providing services of the qualified and experienced staff for operation of CCTV surveillance system installed at Juvenile Justice Board and witness room, Vishwas Nagar, Delhi in all working days from 8:00 AM to 8:00 PM excluding Sundays and Holidays etc. i/c cleaning of all CCTV equipments etc. complete as required and as per terms & conditions. — One Job | |||||
| 6SH:- III (Material) | |||||
| 7LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and<135 lm/Watt). Supplying, of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) | |||||
| 7.1 | 200 Watt | - | Each | - | - |