| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC 25 13 1 AMBEGAON PATHAR PUNE 411046 | PUNE | MAHARASHTRA | 411046 | L1 | Accepted-AOC L1 | |
| 2 | L2₹63.1 L+₹15.9 L (33.8%)Rejected-AOC 43 SABJI MAHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS N KOLKATA 700120 | KOLKATA | 24 PARGANAS N | WEST BENGAL | 700120 | L2 | Rejected-AOC L2 | |
| 3 | L3₹64.4 L+₹17.3 L (36.6%)Rejected-AOC 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L3 | Rejected-AOC L3 | |
| 4 | L4₹66.6 L+₹19.4 L (41.2%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹67.3 L+₹20.2 L (42.9%)Rejected-AOC GOALAPARA MONIRAMPUR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
23 Aug 2021, 6:00 pmClosed
CWE AF Borjhar
Commander Works EngineersAF Military Engineer Services Borjhar PO Borjhar AirportGuwahati15 Assam Pin781015
PROVN OF SMOKE DETECTOR FIRE ALARM SYSTEM IN REPAIR LABS AND STORES UNDER GE AF BORJHAR 2ND CALL
2021_MES_433607_2
CWE (AF)/BOR/TOKEN-59 OF 2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Borjhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE AF Borjhar
₹1.2 L
Yes
8 Oct 2021
22 May 2021
25 Aug 2021
22 May 2021
23 Aug 2021
9 Aug 2021
Amount
Supply, install, testing & commissioning intelligent addressable fire alarm control panel complying with UL Standards and NFPA 72, International Building Code (IBC) and battery backup to one hour with the specifications as appended below:- (a) Power - AC 230V, 50Hz, 2.5-5A (b) 99 devices (c) 99 detectors & minimum one loop (d) Printer Panel and LCD Display with backup of 24 hours in non alarm condition and one hour in alarm condition with separate cabinet for sealed batteries of above 26 AH (Battery Make - Exide/Amron/Amara Raja) panel Make:- Notifier/Bosch/Siemens
Supply, install, testing & commissioning intelligent addressable fire alarm monitoring control panel with battery backup to one hour and LCD Display. Make:- Notifier/Bosch/Siemens
Supply, install, testing & commissioning electronically addressable intellegent detector with electro chemical cell technology that monitors carbon monoxide (CO) produced by smoldering fires, infrared (IR) sensing that measures ambient light levelsand flame signatures, photo-electric smoke detection and thermal detection for temperature monitoring with mounting base and UL Listed. ULC Listed and FM approved with specification as appended below :- (a) Power - Operating voltage range: 15 to 32VDC (b) Maximum Standby Current: 200 A to 24VDC (no communications) (c) Maximum Alarm Current (LED on): 7mA at 24VDC (d) Ingress Protection IP-22 & Material-ABS. Make:- Notifier/Bosch/Siemens
Supply, install, testing & commissioning electronically addressable intellegent detector having multi spectrum and UV/Dual IR/ VIS fire and flame detector with mounting base. Make:- Notifier/Bosch/Siemens
Supply, install, testing & commissioning electronically addressable intellegent manual call point / pull stations with mounting base and UL Listed, CSFM approved, FM approved with the specifications as appended below :- (a) Switch contact: rating 0.25A @ 30 VAC or VDC, auxiliary contact: rating 3.0 A @ 30 VAC or VDC (b) Ingress Protection IP-43 & Material-ABS. Make:- Notifier/Bosch/Siemens
Supply, install, testing & commissioning electronically addressable intellegent remote response indicator with mounting base complying with standard with the specifications as appended below :- (a) Power: 24V (b) Materials - ABS. Make:- Notifier/Bosch/Siemens
Supply, install, testing & commissioning electronically addressable intellegent sounder / horn strobes with mounting base with tamper resistant construction, horn rated at 88+ dBA at 16 Volts with the specifications as appended below :- (a) Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) (b) Humidity Range 2: 10 to 93% non-condensing (c) Strobe Flash Rate: 1 flash per second (d) Nominal Voltage: Regulated 12 DC or regulated 24 DC/FWR1 (Full wave rectified) (e) Operating Voltage Range 2: 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal). Make:- Notifier/Bosch/Siemens
Material and labour for stranded, annealed bare copper conductor fire survival cable of size 1.5 sqmm, 2 core, 1100 V (conform to BS: 7629-1), XLPE insulated, FRLS, inner & outer sheathed drawn through in and including stove enamelled steel concealed conduit (medium grade) of size 20mm dia (ISI Marked) including bend, Tee and other accessories on ceiling/wall/floor/roof through galvanized steel clamp / saddles, stainless steel screws, rawl plug and making grooves in any type of wall and making good the disturbed surfaces as per existing for fire alarm system complete all as specified and as directed. Note: Rate of steel conduit with all accessories deemed to be inclusive of unit rate quoted for this item
Material and labour for stranded, annealed bare copper conductor fire survival cable of size 2.5 sqmm, 2 core, 1100 V (conform to BS: 846-2009), XLPE insulated, GI wire armoured, FRLS, inner & outer sheathed drawn through in and including stove enamelled steel concealed conduit (medium grade) of size 20mm dia (ISI Marked) including bend, Tee and other accessories on ceiling/wall/floor/roof through galvanized steel clamp / saddles, stainless steel screws, rawl plug and making grooves in any type of wall and making good the disturbed surfaces as per existing for fire alarm system complete all as specified and as directed. Note: Rate of steel conduit with all accessories deemed to be inclusive of unit rate quoted for this item.
Supply, install, testing and commissioning of PA Mixer Amplifier on the wall through clamp, wooden/PVC shelve with power output 110 W max, 80W rated power output, provision of one Mic input with one Microphone (Make - Ahuja, Type - AUD 101 XLR), universal serial bus connector with 32 GB storage device, SD/MMC card connector with 64 GB card with adaptor for addressing during fire incident complete all as specified and as directed. Make: Ahuja, Type - SSB-80DFM.
Supply, install, testing and commissioning of two way compact wall speaker 10W, 100V on the wall through clamp, including connection from PA Amplifier to speaker with twin flat speaker cable drawn through in and including DLP mini trunking of size 32 x 12.5 mm with all finishing accessories and junction elements etc. in any type of wall/ceiling and making good the disturbed surfaces to match with the existing surfaces complete all as specified and as directed. Make of Speaker: Ahuja, Type - PS 400 T, Cable: Havells.
Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth for foundation etc or for shafts, wells, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soils complete all as specified and directed.
Removing surplus excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
Material and Labour for dry sand cushioning with coarse sand in trenches for protection of underground electric cable 8cm deep before laying the cable and 15cm thick after laying & stretching of cable complete all as specified and as directed. (Note:- Only punned thickness of sand shall be measured and paid).
Material and labour for sub class 'B' bricks well burnt old size 230x115x75mm laid dry flat with width equal to length of brick for protection of cable complete all as specified and as directed by Engr-in-charge.
Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty LT electric power cable with stranded aluminum conductor 1100 volts grade, conform to IS-7098 (Part-I) 1988 with latest ammendment, laid in trenches / duct / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of cross sectional area 10 Sqmm 3.5 core complete all as specified and as directed.
Supply and fix GI pipe light grade, 50 mm bore including necessary fittings, fixing clamp to wall, for protection of cable for passing through walls, road crossing etc. complete all as specified and as directed.
All as per item No 18 here-in-before but 40mm bore complete all as specified and as directed.
Material and labour for horizontal boring under roads by required T&P without disturbing the existing road surfaces for passing through GI pipe upto 50mm bore complete all as specified and as directed.
Material and labour for Sub main wiring with 2 run of single core 4 Sqmm (nominal area), PVC insulated, unsheathed cable, multi-stranded copper conductor (FRLSH) drawn through in and including DLP mini trunking of size 32 x 12.5 mm with all finishing accessories and junction accessories etc. on roof, walls, ceiling etc including one run of 4 Sqmm (nominal area), PVC insulated, unsheathed cable, multi-stranded copper conductor (FRLSH) as continuous earth wire complete all as specified and as directed. (Note : Two run of single core cable and one run of earth wire alongwith DLP trunking shall be measured as one unit.)
Supply, fixing and testing MCB DB , SPN 4 way, double door with 200 Amp rated bus bar, horizontal type IP-43 including earth and neutral link ,complete with fixing accessories complete all as specified and as directed.
Supply and fixing MCB SPN, 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-10 Amps complete all as specified and as directed.
Material and labour for point wiring with 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLSH cable and 1.5 sqmm multistranded copper conductor FRLSH cable for earth continuity wire, drawn through in and including DLP mini trunking of size 32 x 12.5 mm with all finishing accessories and junction accessories etc. with MS sheet metal switch/ terminal box 1.2 mm thick sheet and Hylum sheet switch boards cover 3.0 mm thick and brass screws with cap washers for one 6 Amp switch socket combination and making the disturbed surface good to match with the existing wall all as directed and specified.
Supply and fixing including connection of switch socket combination 6 Amps, 2 in 1, flush type complete all as specified and directed.
Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level, sourrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filled in alternate layers etc and connected to and including 20 x 3 mm thick copper strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm bore GI pipe connected to main control board and GI pipe medium grade 15 mm bore for watering and including funnel, wire mesh etc including providing RCC pit cover flush to earth pit 50 mm thick reinforced with 8 mm TMT bar 100 mm C/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) including excavation and earthwork, disposal of surplus soil to a distance not exceeding 50 m and testing after completion all as specified and shown on electrical plate No 3 of SSR Part-I complete all as specified and directed.
Material and labour for test point terminal block made of gun metal or phsphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos, 8mm dia 25mm long hexagonal head screw fixed with and including weather proof IP-65 box of size not less than 200x160x98mm and fixed on wall through steel screws and rawl plug complete all as specified and directed
Supply and fixing earth continuity conductor or main earthing lead made of Copper strip of size 20 x 3mm as roof conductor/down conductor above ground level/ burried in ground fixed with saddles (made of Porcelain / PVC ) and screws at a distance 30 cm complete all as specified & directed by Engr-in-Charge
S C TRADING COMPANY
SAI KRISHNA ASSOCIATES
SANKAR TRADERS
JADAV CONSTRUCTION
SKYLIGHT INNOVATIONS
FIRE PROTECTION SYSTEM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .