| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.5 LAccepted-AOC BELABAGAN B DEOGHAR 814142 JHARKHAND | DEOGHAR | DEOGHAR | JHARKHAND | 814142 | ₹69.5 L | L1 | Accepted-AOC As per order |
| 2 | L2₹82.2 LRejected-Finance | ₹82.2 L | L2 | Rejected-Finance As per decision |
| 3 | Rejected-Technical FLAT NO 04 K P NIWAS SANKOSAI DIMNA JAMSHEDPUR | EAST SINGHBUM | JHARKHAND | 831001 | - | - | Rejected-Technical As per decision |
Tender Value
₹72.7 L
EMD Value
₹1.4 L
Closing Date
19 Feb 2026, 5:00 pmClosed
Executive Engineer, SDD-2, chandil
Executive Engineer, SDD-2, chandil
Supply, Installation, Testing and Commissioning of Roof Top Solar System with operation and maintenance for five years at Chandil Dam Circle Office Building.
2026_WRD_110248_1
WRD/SDD-2 CHANDIL/F2/02/25-26
Open Tender
Civil Works
90 days
Chandil
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,000
₹1.4 L
Yes
23 Apr 2026
12 Feb 2026
20 Feb 2026
12 Feb 2026
19 Feb 2026
12 Feb 2026
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF ROOFTOP SOLAR SYSTEM AT CHANDIL DAM CIRCLE OFFICE BUILDING. Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730- Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient tempertature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Above 100 kWp and upto 500 Kwp
FIVE YEAR OPERATION AND MAINTENANACE OF ROOFTOP SOLAR SYSTEM AT CHANDIL DAM CIRCLE OFFICE BUILDING
Add GST @18%
Add Labour Cess @1%
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
document.pdf
Tender Documents • 1.44 MB
BOQ_149071.xls
BOQ • 1.10 MB
Download all tender documents and submit your bid