Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹8.8 L Quoted ₹9.0 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹9.6 L+₹56,910 (6.31%)Rejected-AOC | ₹9.6 L+₹56,910 (6.31%) | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 3 | L3₹10.1 L+₹1.1 L (12.2%)Rejected-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹10.1 L+₹1.1 L (12.2%) | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 4 | L4₹11.8 L+₹2.8 L (30.7%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹11.8 L+₹2.8 L (30.7%) | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
1 Oct 2020, 6:00 pmClosed
CWE Shimla Hills Jutogh
CWE Shimla Hills Jutogh Jutogh Cantt Shimla - 171 008
REPAIR MAINTENANCE OF TRANSFORMER HT POLE PAINTING GOD HT UG CABLE SERVICING OF VCBs SUB STATION EARTHING AT MIL STATION KALKA UNDER GE JUTOGH
2020_MES_372516_1
CA NO CWE/JUT-41 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kalka
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Jutogh
₹25,000
Yes
1 Jan 2021
28 Aug 2020
3 Oct 2020
28 Aug 2020
1 Oct 2020
17 Sept 2020
Amount
Excavation in trenches not.exc 1.5 m wide and n.exc 1.5 m in depth and getting out in soft/loose soil for laying of HT cable including dressing / trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified.
Cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping complete all as specified.
Returning, filling in including spreading, levelling and watering and well ramming in layers n.exc 25 cm thick complete all as specified.
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified.
GI tubing light grade 80 mm bore including specials such as bends etc, laid in trenches/under floor/on walls for protection of UG cable complete all as specified.
Dismantling and taking down old unsv GOD complete all as directed.
Air break gang operated triple switch (GOD) outdoor type , vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element of 25 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection, testing and commissioning complete all as specified.
Lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating including connections fixed in repair including testing and commissioning complete all as specified.
Aluminium conductor steel reinforced (ACSR) including fixing, stretching on poles and proper noseling with binding wire with insulator, jumpring of any size as required at site fixed in repair complete all as specified.
Earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire and arrangement of watering pipe including PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 of MES Schedule Part-I including dismantling ,taking down old unserviceable earthing complete all as specified. Notes: (i) Unit rate quoted shall deemed to include the cost of earth work and excavation, earthing electrode, all connections, nut-bolts, washers, testing, earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh, watering pipe, earth lead protection pipe, test pit. (ii) Earth lead beyond 7.5 m shall be measured and paid for separately under relevant item.
Earthing in replacement complete with galvanized steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized strip 25x4 mm as Earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe medium grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanized Iron/steel of size 75x75x 25mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.
Earthing with copper plate earth electrode 60cmx60cmx3.15mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to copper earth lead strip of size 20X3.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through and including 40 mm dia GI pipe light grade for protection pipe and arrangement of 20 mm dia light grade GI watering pipe including PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 of MES Schedule Part-I including testing and dismantling ,taking down old unserviceable earthing all as directed. Notes: (i) Unit rate quoted shall deemed to include the cost of earth work and excavation, earthing electrode, all connections, nut-bolts, washers, testing, earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh, watering pipe, earth lead protection pipe, test pit. (ii) Earth lead beyond 7.5 m shall be measured and paid for separately under relevant item..
Earth continuity 20x3 mm copper strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. fixed in repair complete all as specified.
Earth continuity 25x4 mm GI strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. fixed in repair complete all as specified.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and wasters,clamps,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer and two coats of aluminum paint including dismantling and taking down old unserviceable complete all as specified.
Pin / Post type insulator vitreous white, brown or green 11000 volts grade of 150 mm dia and 150 mm height including one galvanized mild steel spindle with two GI washers and one galvanized nuts bolts including dismantling and taking down old insulator complete all as specified.
Anti-climbing device, spikes type fabricated out of mild steel bars (round,square and flat) including nuts, bolts, washers and welding in two halves make to shape to suit the cross section of the pole including dismantling and taking down old unserviceable complete all as specified.
Anti climbing device comprising of 2.24 mm dia galvanised steel two strand barbed wire with 2.00mm dia barbs wrapped spirally round the poles, to a length of 0.5 to 1.0 metre clamped and properly secured as directed including dismantling and taking down old unserviceable complete all as specified. Note: clamp shall be measured and paid for separately under relevant item.
XLPE insulated cable screened, PVC bedded galvanized steel strip or wire armoured , electric power cable (Heavy duty ) with aluminum conductor 11000 volts grade cross sectional area 95 sqmm 3 core suitable for HT 11 KV earthed system laid in trenches including taking down old unserviceable HT cable complete all as specified.
Straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 50-95 Sqmm including taking down old unserviceable HT joint complete all as specified. Note: Earth work shall be measured and paid for separately under relevant items.
Cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) indoor type complete with jointing material suitable for HT XLPE cable 50-95 sqmm 3 core 11 KV grade earthed system including taking down old unserviceable HT joint complete all as specified.
Cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 50-95 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as specified.
Maintenance free dry battery 12 volt 18 AH including statndard accessories fixed in repair complete all as speciied.
Loose filling of hard core of broken stones broken to gauge not exceding 63 mm in substations, under poles, under transformers including leveling and spreading lime stone powder under stones complete all as specified.
Servicing of solar street light system at existing postion from various location after disconnecting cable connection from battery , cleaning of solar panel replacing the damage parts/ repairing the minor faults and re connecting the same in its postion etc. including testing for its smooth functioning complete all as specified. Note: Supply only spare parts shall be measured and paid separately under relevant item Make of parts:- Crompton, Bajaj, Havells or equivalent as approved by GE
Solar PV Module 74W
Solar LED Street Light fitting 12/15W
Driver of solar street light fittings suitable for 12/15W LED
Maintenance free Battery Rating 12V & 75AH
Battery box for 12V and 75AH battery including locking arrangement
Connector and wires
Servicing and maintenance of HT Vacuum circuit breaker and HT Panel after taking proper shut down and disconnecting all elctric supply , maint , cleaning,servicing and testing of HT breaker , bus bar, CTs, PTs, IR value, control cables connections, meters connection, tightening and checking of of AC and DC supply, testing of CT and PT , tightening and checking of control wires and other allied works by authorised dealer, removing moisture and dust from HT breaker and inside of HT breaker through CRC and dry cloths , testing of VI leakage with the help of Hi-Pot @ 10 KV, testing of IR value of breaker, testing and checking of operating mechanism, testing and checking of AC and DC supply, testing of opening release and shunt closing , lubricants of all moving parts,testing and operation of on / off through TNC switch and push button ,checking of anti-pump device, reapir of racking mechanism, earth alignment,tightening of loose connection and allied work at 11 kV substations complete, all as specified and directed.
Notes: (i) Unit rate quoted shall deemed to include the cost of measurment of resistance value, tools , labour, petroleum jelly , dry cloths, nut -bolts, CRC, washers etc. (ii) Contractor shall provide company authorised dealer / service centre test / representative test report of internal resistance of breaker and operating time. (iii) Unserviceable parts or items replaced shall be measured and paid for separately under relevant items as supply only.
Calibration / setting of protection devices, relays with all protection function (overcurrent, Earth fault protection), tripping test of overcurrent and earth fault realay through primary and secondary injection machine, testing of auxiliary relay, tripping test through all respected relays and submission of report from authorised service dealer / center / representative complete all as specified and directed. Notes:- (i) Unit rate quoted shall deemed to include the cost of all All equipments, tools , labour. (ii) Contractor shall provide company authorised dealer / service centre / representative test report of calibration of relay. (iii) Unserviceable parts or items replaced shall be measured and paid for separately under relevant items as supply only.
Supply only highly HT insulating opaque red coloured ANTI TRACK COATING SPRAY (SPRAY-320 of MOSIL) that forms flexible chemical resistane coating to class H winding for electrical apparatus, in 500 ml spray bottles to protect HT equipments, bus bar, CTs, PTs from current leakage due to moisture complete all as specified.
Supply only HT bus bar insulator for HT panel suitable for Crompton greaves VCB Panel model UNIVAC and Siemens VCB panel at 11 KV substations complete all as specified.
Supply only spout suitable for Crompton greaves / Siemens VCB at 11 KV substations complete all as specified.
Supply only TNC switch suitable for Crompton greaves / Siemens VCB at 11 KV substations complete all as specified.
Supply only digital ammeter suitable for Crompton greaves / Siemens VCB at 11 KV substations complete all as specified.
Supply only digital volt meter suitable for Crompton greaves / Siemens VCB at 11 KV substations complete all as specified.
Supply only digital trivector meter suitable for Crompton greaves / Siemens VCB at 11 KV substations complete all as specified.
Supply only LED indicator lamp of different colours(red,green,yellow,white etc) suitable for Crompton greaves / Siemens VCB at 11 KV substations complete all as specified.
Supply only current transformer of ratio 10/5A, outdoor epoxy cast type, line voltage 11 kV, class 1.0/5P10, 50 Hz, size and model suitable for existing CTs installed at Mehtab Majra for HT meter complete all as specified.
Supply only current transformer of ratio 10/5A, burden 15 VA, indoor, epoxy cast type, line voltage 11 kV, class 0.5/5P10, 50 Hz, size and model suitable for existing CTs installed at 11 KV Substation suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only potential transformer of ratio 11kV/3/110V/3, burden 110 VA/Phase, indoor epoxy cast type line voltage 11 KV, insulation level 28/75 KV (P) class 1.0, 50 Hz size and model suitable for existing PTs installed at 11 KV Substation suitable for Crompton greaves VCB Incomer at 11 KV substations complete all as specified.
Supply only potential transformer of ratio 11kV/3/110V/3, burden 110 VA/Phase, outdoor epoxy cast type line voltage 11 KV, insulation level 28/75 KV (P) class 1.0, 50 Hz size and model suitable for existing PTs installed at Mehtab Majra for HT meter complete all as specified.
Supply only shunt closing coil 48 V /96 V DC / AC suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only tripping coil 48 V / 96 Volt DC / AC suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only racking mechanism complete suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only tulip contact 08/12 fingers of circuit breaker suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only auxiliary switch with 24/36 pins including wiring with sockets suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only operating mechanism suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only motor cut off switch suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only PT Bushing of capacity 11KV suitable to fit on exisitng PTs suitable for Crompton greaves at 11 KV substations complete all as specified.
Supply only PT fuse of capacity 11 KV suitable to fit on exisitng PTs suitable for Crompton greaves at 11 KV substations complete all as specified.
Strip heaters 80-100 watt , AC 240 volts from HT panel of 11 KV substations including taking down old unserviceable strip heater complete all as specified.
Combined over current and earth fault numerical relay with input current 1A/5A and auxiliary voltage 24 V including complete installation in 11 kV VCB panel, complete connections and testing at 11 KV sub stations as per instruction from OEM complete all as specified and directed. Make: Model CG14N of CG or its equivalent in ABB or Siemens. Notes: (i) Relay shall be fixed in existing HT panel including cutting , welding, drilling or any other suitable means or shall be fixed in separate cabinet without any extra cost to department (ii) All type of wires required for proper connection shall be provided by contractor without any extra cost to department. (iii) Proper functioning and testing shall be carried out without any extra cost to department.
Master tripping relay of auxillery voltage 24 V/110V AC / DC including installation in 11 kV VCB panel,and connections and testing at 11 KV sub stations as per instruction from OEM complete all as specified and directed. Make: CG, ABB or Siemens. Note :(i) Relay shall be fixed in existing HT panel by cutting , welding, drilling or any other suitable means or shall be fixed in separate cabinet without any extra cost to department (ii) All type of wires required for proper connection shall be provided by contractor without any extra cost to department. (iii) Proper functioning and testing shall be carried out without any extra cost to department.
Detecting of fault in HT UG cable with fault locator equipment to locate the fault in HT cable of length not less than 50 RM . Note :- (a) The fault which is detected through cable fault locater shall only be paid under this item (b) Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator shall be provided by the contractor for even single fault and no dealy on this account shall be acceptable otherwise penality of Rs. 1000/- per day shall be levied. (d) Necessary testing of cable after making joint shall be deemed to be including in the unit rate quoted. However necessary earth work, cable cutting , joint making Joint shall be paid under relevant items.
Trimming of trees along over head electric line and making line free from any kind of vegetation except tree trunks up to 1.50 metre all around the conductors and uprooting vegetation growth around pole complete all as specified.
Supply only tinned copper fuse wire for HT supply from 8 SWG to 38 SWG complete all as directed.
Supply only in replacement of Blue silica gel 4-6 mesh suitable for transformers breather and to protect HT/LT panels from moisture as per site requirement complete all as specified.
HDPE (DWC) tubing 100 mm dia of pressure rating 6Kgf/Cm2 fixed in repair to poles, walls under floors, laid on surface etc as required at site complete all as directed. Note: Unit rate quoted shall deemed to include the cost of all items and accessories such as bends, joints, nut bolts, clamps etc.
Non-metal part HV bushing with packing for outdoor / indoor / canopy type distribution transformer (11 /0.433 kV)of capacity upto 400 KVA fixed in repair complete all as specified.
HT brass bush rod of suitable size for outdoor / indoor / canopy type distribution transformer (11 /0.433 kV) of capacity upto 400 KVA fixed in repair complete all as specified.
Non-metal part LV bushing with packing for outdoor / indoor / canopy type distribution transformer (11 /0.433 kV) of capacity upto 400 KVA fixed in repair complete all as specified.
LT bush rod made of brass of suitable size for outdoor / indoor / canopy type distribution transformer (11 /0.433 kV) of capacity upto 400 KVA fixed in repair complete all as specified.
Top cover gasket of suitable size for outdoor / indoor / canopy type of transformer upto 400 KVA fixed in repair complete all as specified.
Preparing surfaces of transformer of capacity up to 400 KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, and writing MES No / SM No with 3" letters on each transformer after painting with white colour on black background complete all as specified. Note: (i) Painting of transformer shall be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor.
Heating, filtration and dehydration of transformer oil as per IS : 10028 (Part-III) 1981, Para 5.2 (obtained from transformer/ servo voltage stablizer with dehydration/ filtration plant to achieve dielectric strength of 40KV at 2.5 mm gap, complete all as specified. Note:- Any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
Transformer oil as per IS : 335 (1993) for transformers installed at various sites or in repair for topping up after dehydration to achieve the di electric strength 60 KV at 2.5 mm gap, complete all as specified.Note : Transformer oil shall be brought to site in sealed containers from the original manufacturer and shall be opened in the presence of Engr-in-charge. Container shall be deposited by the contractor with the department which shall be returned after completion of work.
Breather transparent type suitable for step down distribution transformers of capacity upto 400 KVA fixed in repair complete all as specified.
Preparation of surface of steel tubular poles HT 11 metres long and removing rusted particles and painting with two coats of aluminium paint over a coat of red oxide primer including cross arms, bracing, supports, clamps, eye hooks etc and painting black & white 30 cm strips alternatively with synthetic enamel paint two coats from coping upto 1.5 metre height starting with black strip complete all as specified.
KATWAL TECHNOCRATS
M/S Sonu Traders
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .