Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10,620Accepted-AOC 75 ELECTRONICS ESTATE PERUNGUDI CHENNAI TAMIL NADU 600096 | CHENNAI | TAMIL NADU | 600096 | ₹10,620 | L1 | Accepted-AOC Being L1 for Sl. No. 7 |
| 2 | L1₹34,751Accepted-AOC | ₹34,751 | L1 | Accepted-AOC Being L1 for Sl. No 9 |
| 3 | L1₹47,318Accepted-AOC | ₹47,318 | L1 | Accepted-AOC Being L1 for Sl. Nos. 2,4,5,6,8 |
| 4 | L1₹53,867Accepted-AOC 42 MEENACHI SUNDARAM ST KARUNGAL PALAYAM ERODE | ERODE | ERODE | TAMIL NADU | ₹53,867 | L1 | Accepted-AOC Being L1 for Sl. Nos. 1,3,10 |
| 5 | L2₹1.3 LRejected-Finance VERBAL BUILDING 2 468 PHUDUPPATTI ROAD NEAR JEYAVILAS GARDEN KADACHANENTHAL MADURAI 625107 | MADURAI | MADURAI | TAMIL NADU | 625107 | ₹1.3 L | L2 | Rejected-Finance Rejected Being L2 |
| Sl No | Description | Qty | Unit | GM ELECTRONICS L5 | Vi Microsystems Pvt Ltd L3 | MI Measuring Instruments L2 | Om Technocrafts Corporation L1 | GREENTEK TRADERS L6 | BARATHI ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | DTH Trainer kit
Power Supply:
• 200 V to 240 V ac, 50 Hz.
Dish Antenna:
• 1.5 ft aluminium steerable dish antenna.
LNB (Low Noise Block Down Converter):
• Input frequency: Ku -band.
• Output frequency: 950 MHz to 1450 MHz.
• Conversion gain: 65 dB.
• Noise temperature: 35 K (max )
Set -Top Box Receiver in Trainer Form:
• IF frequency: 70 MHz.
• Video bandwidth: 50 Hz to 5 MHz.
• Video output level: 1 Vpp at 75 Ω load.
• Video polarity: Normal/Inverted, switch selectable.
Audio subcarrier frequency:
Tunable from 5.0 MHz to 8.0 MHz.
• Remote control provided.
• HDMI cable: 10 m.
Controls:
• Channel selection.
• Volume control.
Fault Simulation:
• Five built -in simulated faults for troubleshooting experiments.
• IF signal disconnected.
• Video output fault.
• Audio mute fault.
• Tuner misalignment.
• RF output interruption.
PCB Size:
• 15" × 12" with multicolour section -wise block diagram.
Standard Accessories:
• 1.5 ft dish antenna.
• LNB.
• Trainer PCB.
• Dish connecting wire.
• Audio -video cable.
• User manual.
• Acrylic cover.
• Hardware materials for assembly of dish antenna. Additional Features:
• DTH subscription connection with Doordarshan free channels.
• Free -to -air channel demonstration. | 3 | Nos. | 49,704 ₹58,650.72 | - | - | 29,400 ₹34,692 Lowest | 46,500 ₹54,870 | 36,600 ₹43,188 |
| 2.00 | DC Voltmeter ANALOG - Moving coil - (0-30)V, Class 1.0 (±1 % full-scale) accuracy | 15 | Nos. | 9,270 ₹10,938.6 | 9,000 ₹10,620 | 8,250 ₹9,735 | 9,750 ₹11,505 | 6,450 ₹7,611 Lowest | 11,025 ₹13,009.5 |
| 3.00 | DC Digital Voltmeter - 3½ digit LED/LCD display, Measurement range: 0–20 V dc, Accuracy: Class 0.5(±0.5 % full-scale) | 15 | Nos. | 12,420 ₹14,655.6 | 21,000 ₹24,780 | 15,000 ₹17,700 | 9,750 ₹11,505 Lowest | 14,250 ₹16,815 | 11,175 ₹13,186.5 |
| 4.00 | DC Ammeter ANALOG – Moving coil - (0-100) mA, Class 1.0 (±1 % full-scale) accuracy | 15 | Nos. | 9,270 ₹10,938.6 | 9,000 ₹10,620 | 8,250 ₹9,735 | 9,750 ₹11,505 | 6,450 ₹7,611 Lowest | 11,025 ₹13,009.5 |
| 5.00 | DC Ammeter Analog - Moving coil - (0 -500) mA, Class 1.0 (±1 % full-scale) accuracy | 5 | Nos. | 3,090 ₹3,646.2 | 3,000 ₹3,540 | 2,750 ₹3,245 | 3,250 ₹3,835 | 2,150 ₹2,537 Lowest | 3,675 ₹4,336.5 |
| 6.00 | DC Ammeter Analog - Moving coil - (0 - 1000) μA, Class 1.0 (±1 % full-scale) accuracy | 5 | Nos. | 3,590 ₹4,236.2 | 3,000 ₹3,540 | 3,000 ₹3,540 | 3,250 ₹3,835 | 2,150 ₹2,537 Lowest | 3,675 ₹4,336.5 |
| 7.00 | DC Ammeter DIGITAL - 3½ digit LED/LCD display, Measurement range: 0–5 A dc, Accuracy: Class 0.5 (±0.5 % full-scale) | 15 | Nos. | 14,970 ₹17,664.6 | 9,000 ₹10,620 Lowest | 18,000 ₹21,240 | 9,750 ₹11,505 | 14,250 ₹16,815 | 11,175 ₹13,186.5 |
| 8.00 | Decade Capacitance Box
• Range: 100 pF to 100 μF
• Rotary switch selection with 6 dials.
• Maximum voltage: 350 V.
• Accuracy: ±1%. | 10 | Nos. | 29,980 ₹35,376.4 | 32,500 ₹38,350 | 32,000 ₹32,000 | - | 22,900 ₹27,022 Lowest | 29,400 ₹34,692 |
| 9.00 | Decade Inductance Box
• Range: 10 µH to 10 H.
• Rotary switch selection with 6 dials.
• Low-loss inductors.
• Accuracy: ±1%. | 10 | Nos. | 30,980 ₹36,556.4 | 33,500 ₹39,530 | 35,000 ₹35,000 | - | 30,000 ₹35,400 | 29,450 ₹34,751 Lowest |
| 10.00 | SIM Reader Trainer kit
Power Supply:
• Operates on 230 V ac ±10%, 50 Hz mains supply.
• Built -in regulated SMPS power supply.
• Operating DC supply: 5 V / 12 V with overload and short -circuit protection.
SIM Card Interface:
• Supports GSM SIM cards compatible with 2G / 3G / 4G / 5G networks.
• SIM card read/write interface.
• Supports SIM card initialization, authentication, and communication functions.
• Compatible with standard 6 -pin / 8 -pin SIM card sockets.
Communication Interface:
• USB 2.0 interface for PC communication.
• RS -232 serial communication interface.
• UART communication facility for embedded system interfacing.
SIM Operating Parameters:
• Selectable SIM clock frequencies:
• 3.579 MHz
• 7.159 MHz
• 14.318 MHz
• SIM supply voltage selection facility.
• SIM reset and activation control.
Supported Protocols and Standards:
• GSM ETSI 07.07 and ETSI 07.05 AT command support. • ISO/IEC 7816 smart card communication support.
• SIM communication command monitoring facility. Hardware Features:
• On -board SIM card socket.
• LED indication for:
• Power status
• SIM detection
• Reset activity
• Data transmission/reception
• Built -in keypad for standalone operation.
• LCD display module (128 × 64) for menu and status display.
• On -board microcontroller -based control section. Software Support:
• AT command execution and monitoring software.
• SIM manager utility software.
• Data logging and communication terminal utility.
• PC -based GUI software for SIM data communication experiments. Trainer Features:
• Fault simulation facility for troubleshooting experiments.
• Simulation of faults such as:
• SIM not detected
• Clock failure
• VCC failure
• Reset failure
• Multiple on -board test points for signal observation.
• Test points for:
• SIM_RST
• SIM_CLK
• SIM_IO
• VCC
• UART TX/RX
• Suitable for CRO/DSO signal monitoring.
• Glass epoxy PCB with educational block diagram layout.
• Compact tabletop enclosed cabinet design. Construction:
• Front panel with printed block diagram.
• Banana test points and patching facility. Standard Accessories:
• GSM SIM trainer unit.
• USB communication cable.
• RS -232 communication cable.
• Power cord.
• User manual.
• Utility software CD / downloadable software package. | 1 | Nos. | - | - | - | 6,500 ₹7,670 Lowest | 22,500 ₹26,550 | - |
Tender Value
Refer Docs
Closing Date
22 Jul 2026, 3:00 pmClosed
PRINCIPAL
GOVERNMENT POLYTECHNIC COLLEGE, TRIVANDRUM ROAD, TIRUNELVLEI
REFER TENDER NOTICE
2026_DoTE_684310_1
10/A3/2026
Open Tender
Electronics Equipment
Supply
GOVERNMENT POLYTECHNIC COLLEGE
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
19 Aug 2026
7 Jul 2026
23 Jul 2026
7 Jul 2026
22 Jul 2026
7 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | DTH Trainer kit
Power Supply:
• 200 V to 240 V ac, 50 Hz.
Dish Antenna:
• 1.5 ft aluminium steerable dish antenna.
LNB (Low Noise Block Down Converter):
• Input frequency: Ku -band.
• Output frequency: 950 MHz to 1450 MHz.
• Conversion gain: 65 dB.
• Noise temperature: 35 K (max )
Set -Top Box Receiver in Trainer Form:
• IF frequency: 70 MHz.
• Video bandwidth: 50 Hz to 5 MHz.
• Video output level: 1 Vpp at 75 Ω load.
• Video polarity: Normal/Inverted, switch selectable.
Audio subcarrier frequency:
Tunable from 5.0 MHz to 8.0 MHz.
• Remote control provided.
• HDMI cable: 10 m.
Controls:
• Channel selection.
• Volume control.
Fault Simulation:
• Five built -in simulated faults for troubleshooting experiments.
• IF signal disconnected.
• Video output fault.
• Audio mute fault.
• Tuner misalignment.
• RF output interruption.
PCB Size:
• 15" × 12" with multicolour section -wise block diagram.
Standard Accessories:
• 1.5 ft dish antenna.
• LNB.
• Trainer PCB.
• Dish connecting wire.
• Audio -video cable.
• User manual.
• Acrylic cover.
• Hardware materials for assembly of dish antenna. Additional Features:
• DTH subscription connection with Doordarshan free channels.
• Free -to -air channel demonstration. | 3 | Nos. | - | - |
| 2 | DC Voltmeter ANALOG - Moving coil - (0-30)V, Class 1.0 (±1 % full-scale) accuracy | 15 | Nos. | - | - |
| 3 | DC Digital Voltmeter - 3½ digit LED/LCD display, Measurement range: 0–20 V dc, Accuracy: Class 0.5(±0.5 % full-scale) | 15 | Nos. | - | - |
| 4 | DC Ammeter ANALOG – Moving coil - (0-100) mA, Class 1.0 (±1 % full-scale) accuracy | 15 | Nos. | - | - |
| 5 | DC Ammeter Analog - Moving coil - (0 -500) mA, Class 1.0 (±1 % full-scale) accuracy | 5 | Nos. | - | - |
| 6 | DC Ammeter Analog - Moving coil - (0 - 1000) μA, Class 1.0 (±1 % full-scale) accuracy | 5 | Nos. | - | - |
| 7 | DC Ammeter DIGITAL - 3½ digit LED/LCD display, Measurement range: 0–5 A dc, Accuracy: Class 0.5 (±0.5 % full-scale) | 15 | Nos. | - | - |
| 8 | Decade Capacitance Box
• Range: 100 pF to 100 μF
• Rotary switch selection with 6 dials.
• Maximum voltage: 350 V.
• Accuracy: ±1%. | 10 | Nos. | - | - |
| 9 | Decade Inductance Box
• Range: 10 µH to 10 H.
• Rotary switch selection with 6 dials.
• Low-loss inductors.
• Accuracy: ±1%. | 10 | Nos. | - | - |
| 10 | SIM Reader Trainer kit
Power Supply:
• Operates on 230 V ac ±10%, 50 Hz mains supply.
• Built -in regulated SMPS power supply.
• Operating DC supply: 5 V / 12 V with overload and short -circuit protection.
SIM Card Interface:
• Supports GSM SIM cards compatible with 2G / 3G / 4G / 5G networks.
• SIM card read/write interface.
• Supports SIM card initialization, authentication, and communication functions.
• Compatible with standard 6 -pin / 8 -pin SIM card sockets.
Communication Interface:
• USB 2.0 interface for PC communication.
• RS -232 serial communication interface.
• UART communication facility for embedded system interfacing.
SIM Operating Parameters:
• Selectable SIM clock frequencies:
• 3.579 MHz
• 7.159 MHz
• 14.318 MHz
• SIM supply voltage selection facility.
• SIM reset and activation control.
Supported Protocols and Standards:
• GSM ETSI 07.07 and ETSI 07.05 AT command support. • ISO/IEC 7816 smart card communication support.
• SIM communication command monitoring facility. Hardware Features:
• On -board SIM card socket.
• LED indication for:
• Power status
• SIM detection
• Reset activity
• Data transmission/reception
• Built -in keypad for standalone operation.
• LCD display module (128 × 64) for menu and status display.
• On -board microcontroller -based control section. Software Support:
• AT command execution and monitoring software.
• SIM manager utility software.
• Data logging and communication terminal utility.
• PC -based GUI software for SIM data communication experiments. Trainer Features:
• Fault simulation facility for troubleshooting experiments.
• Simulation of faults such as:
• SIM not detected
• Clock failure
• VCC failure
• Reset failure
• Multiple on -board test points for signal observation.
• Test points for:
• SIM_RST
• SIM_CLK
• SIM_IO
• VCC
• UART TX/RX
• Suitable for CRO/DSO signal monitoring.
• Glass epoxy PCB with educational block diagram layout.
• Compact tabletop enclosed cabinet design. Construction:
• Front panel with printed block diagram.
• Banana test points and patching facility. Standard Accessories:
• GSM SIM trainer unit.
• USB communication cable.
• RS -232 communication cable.
• Power cord.
• User manual.
• Utility software CD / downloadable software package. | 1 | Nos. | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
BOQ_822606.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .