| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC | L1 | Accepted-AOC Awarded |
Tender Value
₹44.7 L
EMD Value
₹89,440
Closing Date
8 Mar 2024, 12:00 pmClosed
EE, PWD(R),New Guwahati Territorial Road Div.
Bamunimaidam, Guwahati
Electrical rewiring of the office of the Chief Engineer, Pwd (Roads),Chandmari, Guwahati-03 under SOPD (G) for the year 2023-24 (RETENDER)
2024_PWD_36851_1
NGTRD/ CS-245 / SOPD (G) /2023-24/3495-A
Open Tender
Civil Works
Works
60 days
Kamrup
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,342
Yes
₹89,440
Yes
24 Jun 2024
4 Mar 2024
8 Mar 2024
4 Mar 2024
8 Mar 2024
4 Mar 2024
4 Mar 2024 - 8 Mar 2024
Amount
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recess medium class PVC conduit as required. i) 2x1.5sq mm +1x1.5 Sqmm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recess medium class PVC conduit as required ii) 2x2.5sq mm +1x2.5 Sqmm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recess medium class PVC conduit as required ii) 2x4 sq mm +1x4 Sqmm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recess medium class PVC conduit as required ii) 4x10 sq mm +2x6 Sqmm earth wire
Rewiring for light point / fan point / exhaust fan point / call bell point (for door call bell only) with 1.5 Sq.mm FRLS PVC insulted copper conductor single core cable in surface / recessed medium class PVC conduit, with modular swith, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Group C
Supplying and fixing the following sizes of medium class PVC conduit along with acessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. i) 25mm
Supplying and fixing the following sizes of medium class PVC conduit along with acessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. ii) 32mm
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. i) 5/6amp Switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. ii) 15/16amps Switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. iii) 3 Pin 5/6A socket outlet
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. iv) 6 Pin 15/16A socket outlet
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. i) 3 Module (100mmx75mm)
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. ii) 4 Module (125mmx75mm)
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. iii) 6 Module (200mmx75mm)
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. iv) 8 Module (125mmx125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc as required.i) 3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc as required.ii) 6 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc as required.iii) 8 Module
Providing and fixing the following rating and breaking capactity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panle board including drilling holes in the cubicle panel, making connections etc as required. i) 200A, 36KA, FPMCCB
Supplying and fixing following way, horizontal type three pole and neutral, steel sheet, MCB Distribution Board, 415V on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted including earthing etc as required (But without MCB / MCCB/RCCB / Isolator) i) 6way (4+18) Double door
Supplying and fixing following way, horizontal type three pole and neutral, steel sheet, MCB Distribution Board, 415V on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted including earthing etc as required (But without MCB / MCCB/RCCB / Isolator) ii) 8way (4+24) Double door
Supplying and fixing of following ways surface / recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel dust protected, duly powder painted inclusive of 200amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required) i) 8 way (4+24), Double door
Supplying and fixing following rating, four pole, 415 volts, residual current circuit breaker, having a sensitivity current 20mA in the existing MCB DB complete with connections, testing and commissioning etc as required. i) 63A
Supplying and fixing 5amps to 32 amps rating, 240/420 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. i) Single pole
Supplying and fixing 5amps to 32 amps rating, 240/420 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. i) Single pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc as required
Earthing with GI earth pipe 4.5meter long, 40mm dia including accessories and provising masonry enclosure with cover plate having locking arrangement and water pipe etc with charcoal / coke and salt as required
Supplying and laying 6SWG GI wire at 0.50meter below ground level for conductor earth electrode including connection etmination with GI thimble etc as required
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. Above 35 Sq.mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
Supplying of pole, 63 Ampere rating MCB with connections as necessary and as directed by the Deptt.
Supplying of 4 core Aluminium unarmoured 50sq mm power cable
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .