Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | Not yet disclosed by govt. Qualified Make: MAHINDRA - GSP
Model: MM4430SITTCI(R)-C2 | Make: MAHINDRA - GSP
Model: MM4430SITTCI(R)-C2 | - | - | Qualified |
| 2 | Not yet disclosed by govt. Qualified Make: MAHINDRA GSP RETAIL
Model: MAHINDRA & 3445 GM C2 | Make: MAHINDRA GSP RETAIL
Model: MAHINDRA & 3445 GM C2 | - | - | Qualified |
| 3 | Not yet disclosed by govt. Qualified Make: Mahindra
Model: MAHINDRA POWEROL AND MODEL 3385 TCI GMc2 (three phase) | Make: Mahindra
Model: MAHINDRA POWEROL AND MODEL 3385 TCI GMc2 (three phase) | - | - | Qualified |
| 4 | Not yet disclosed by govt. Qualified Make: PERFECT DG SETS
Model: PERFECT (PECH - 30) | Make: PERFECT DG SETS
Model: PERFECT (PECH - 30) | - | - | Qualified |
| 5 | L1₹3.9 LDisqualified Make: KOHLER
Model: KOHLER-KDG0030P1 140 NAGINDAS MASTER ROAD MUMBAI MAHARASHTRA 400001 | MUMBAI | MAHARASHTRA | 400001 | Make: KOHLER
Model: KOHLER-KDG0030P1 | ₹3.9 L | L1 | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Jul 2018, 5:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 30 30 No of Phase - Single phase
Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic Class of governer A1 A0
A1
A2 Number of cylinders (nos) 3 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for 10 - 1/4 one hour for every 11 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 30 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 88.5 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 1 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual
AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 Thickness of Foam 25 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation With Installation
Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ram Kumar Singh 825401
District Board
Chatra Near DC Office 1 15
333365
GEM/2018/B/47261
diesel generators- DG Sets
15 days
Jharkhand; Chatra
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 30 30 No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic Class of governer A1 A0 | - | - | - |
| A1 | - | - | - |
| A2 Number of cylinders (nos) 3 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for 10 - 1/4 one hour for every 11 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 30 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 88.5 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 1 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 25 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ram Kumar Singh 825401 | - | - | - |
| District Board | - | - | - |
| Chatra Near DC Office 1 15 | - | - | - |
Exempted
6 Aug 2018
14 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_333365.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .