Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹47.5 L
EMD Value
₹94,960
Closing Date
2 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(N) Bikaner
GE (N) Bikaner (Raj) PIN-334001
SPL REPAIR TO BLDGS NO P-04A (URC) OF 624 EME BN AND BLDG NO P-45 (TROOPS LIVING) P-46 (STORES) OF OFFRS MESS OF HQ 8 INF BDE CAMP AT MIL STN BIKANER UNDER GE(N) BIKANER
2025_MES_743281_1
GE (N) BKN-TOKEN/39/2025-26
Open Tender
Miscellaneous Works
Item Rate
270 days
GE(N) Bikaner
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(N) Bikaner
₹94,960
Yes
5 Dec 2025
5 Dec 2025
9 Jan 2026
5 Dec 2025
2 Jan 2026
19 Dec 2025
Demolition Stone slabs of any description or thickness in roof ,sun shades, Chajjas, floors, aprons etc laid bedded and pointed in any mortar. (Note: Dismantling shall be carried out in portion only .)
Dismantling Brick tiles or terracing tiles,single layer on roofs all as specified and directed.
Demolition of lime Concrete to any thickness in any position incl all topping thickness (below or above ground level).
Demolition cement concrete unreinforced of any description and in any position not otherwise specifically provided.
Raking out joints/pointing to brick work or stone patti ceiling laid flat in lime concrete complete
Taking down cement plaster, any description on brick or stone or cement concrete walls including any tiles and raking out joints, hacking for key, scrubbing down with water complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), all as specified and directed by Engineer-in Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), all as specified and directed by Engineer-in Charge.
Taking down shutter exc 1 sqm and n exc 2 sqm each and refixing in the same opening after rescuring or easing & adjustment all as specified and directed by Engineer-in Charge.
Demolition of brick/stone masonry built in CM. all as specified.
Dismantling cast iron /PVC pipes fixed to walls or laid in trenches in any position.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr In Charge
M&L Brick work with fly ash bricks straight or curved on plan to any radius built in CM 1:4 all as specified.
M&L Half Brick work with fly Ash bricks straight or curved on plan to any radius built in CM 1:4 all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified.
M&L for Rendering 15 mm thick in two layers on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately).
M&L for Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified.
M&L for Rendering 5 mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified.
M&L Vitrified ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in floors ,area of each tile exc 0.18 sqm but n.exc. 0.38 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, over and including 15 mm thick screed plaster in CM 1:6 complete all as specified and directed
M&L Vitrified ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in skirting ,dados etc. area of each tile exc 0.18 sqm but n.exc. 0.38 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 10 mm thick screed plaster in CM 1:4 complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr In Charge.
M&L for 50 mm thick PCC 1:3:6 20 m graded stone aggregate type C-1 using 20mm graded crushed stone aggregate as in levelling course for roof etc complete all as specified.
M&L for Machine cut kota stone slab flooring 18-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab jointless joint including rubbing and polishing complete all as specified in SSR pt I Para 13.47.4 and as directed by Engineer-in-Charge.
M&L for flush pointing in cement mortar 1:3 on ceiling surfaces of stone patti roofs complete all as specified.
M&L for Kota stone slab 18-22mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified in SSR pt I Para 13.47.4 and as directed by Engineer-in-Charge.
Cutting chases,pinning in making good to facing where requried and pointing in cement mortar 1:3 to ends or edge of landings,steps,cills,sunshade,shelves, lintel etc. tubes or concealed conduit etc. and making good, cutting not exc 10 cm girth
M&L Jodhpur stone of roof slabs, self faced 7.5 cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6 complete
M&L 20-25 mm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete al as specified.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V,50Hz, RPM1200, copper winding of sweep 300mm complete all as specified and directed by Engr In Charge.
All as per item No 210 here -in- before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed .
S & F Mild steel framed work such as grills, gratings, tank staging etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks, cooler stand and similar work conforming to Fe 290 Gd E-165 all as specified .
Supply only liquid water proofing compound complete all as specified.
Cleaning of surface of loose dust and grit and cement slurry etc. by means of wire brush dust removing and scrapper etc .Pot holes/cracks shall be repaired with cement admixed with polymer as per manufacturer instructions complete all as specified and directed by Engg In Charge.
Providing PCC coving /gola along vertical parapets of size 75 mm x 75 mm with concrete mix (1:2:4) type B1 using WPC of approved make etc complete all as specified and directed by Engg In Charge.
The surface shall be treated with PU Elastoseal primer with Epoxy primer to seal the pores and enhance the adhesion of the coating,supplying and applying single component waterproofing liquid membrane based on pure,elastomeric,polyurethane resin cold applied of spray/brush applied membrane with an elongation of (650%+,- 50 ) and tensile strength not less than 2 Mpa ,crack bridging ability not less than 2 mm.No leakage upto 5 bars of water pressure.shore hardness > 50 shore. The Minimum thickness to be applied shall be 1.5 mm,( overall )in two layers (each layer 750 micron) or as per manufacurer's instructions so as acheive thickness not less tha 1.5 mm complete all as specified and directed by Engr-in-Charge.
Providing and laying SRI (Sun Resistance Index ) roof tiles (size 300x300x9-10 mm) with 20 mm thick cement plaster in CM (1:4) mixed with liquid WPC as per manufacturer's instructions confirming to required slope complete all as specified and directed by Engg In Charge. Note :- For Roof Treatment process Make of PU Primer /Membrane :- SIKA/BASF,BERGER/STP FOSROC/ SAINT GOBIN /PIDILITE
S&F for factory made single extruded WPC ( Wood polymer composite) solid door /window/ceosetory windows& other Frames/Chowkhat of size 65x100 mm compraising of virgin PVC polymer of K value 58-60 ( Suspension grade),calcium carbonate and natural fibers (wood powder/rice husk/wheat husk ) and non toxic additives ( maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum,screw withdrawal strength of 2200 N(face) & 1100 N ( Edge),minimum compressive strength of 58 N/mm2,modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fastners of required dia and length complete as per direction of Eng In charge .( MS holdfast / lugs dash fastners shall be included in unit rate of item). Note:- For WPC solid door/window frames,minus 5 mm toletance in dimension i.e. depth and width of profile shall be acceptable .Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F for factory made single extruded WPC ( Wood polymer composite) solid plain flush door shutter of size 30 mm thick compraising of virgin PVC polymer of K value 58-60 ( Suspension grade),calcium carbonate and natural fibers (wood powder/rice husk/wheat husk ) and non toxic additives ( maximum toxicity index of 12 for 100 gms ) having minimum density of 650 kg/cum,screw withdrawal strength of 1800 N(face) & 900 N ( Edge),minimum compressive strength of 50 N/mm2,modules of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixing with Stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws ,complete as per direction of Eng In charge . Note:- SS butt hinges and SS screws shall be included in unit rate of item.
S&F for 100 mm Stainless steel Butt hinges
S&F for 150mm Stainless steel handles.
S&F SS sliding door bolt, length 250 mm nuts and washers all as specified
S&F for 150mm size Stainless steel barrel tower bolts all as specified and directed.
S&F factory made mild steel Window/Ventilator box type with side huge shutters incl pintol hinges,steel handles, steel peg stay and all locking arrangement and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEBTZ/TD/888R & 889 ii) MS fillets, glazing, wire gauge shall be measured and paid separately iii) opening incl provn shutter for cooler to be provided as directed
S&F Anodised Aluminium frame door, window ,ventilator frames/shutter ,other sections for doors , windows , ventilators with one or more rebates , channel for sliding shutters , grills etc including jointing cleats for fixing etc , complete all as specified. .
Hacking out old broken glass (any thickness ,size quality or description) from wooden/metal frame including punching or drilling out old glazing pins/spring clips glazed with putty and removing materials from site of work all as directed by the Engineer-in-charge.
S&F sheet glass 4.8 mm thick ordinary quality & glazing with rubber gasket in squares exc 0.5sqm in each pane as in aluminium door complete all as specified and directed by Engineer-in-Charge.
S & F aluminium glazing clip with rubber gasket of suitable size and thickness as required at site for fixing glass in aluminium door/windows complete all as specified and directed by Engineer-in-Charge.
S & F for door closer hydraulically regulated , designation No 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 KG and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares n exe 0.5 sqm each pane all as specified
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F in repair Stainless steel wire cloth 0.36 mm nominal dia of wire and avg width of aperture1.40mm
S&F in repair 20 mm dia mild steel curtain rod chromium plated incl brackets, stops etc. complete all as specified.
Earthing complete with galvanised steel pipe electrode, 32mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 6mm dia galvanised iron or steel wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
S&F PVC (SWR)single socketed in any length with rubber ring joint fixed with wall of 110mm
M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width & girth & applying one
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width and grith and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
coat of synthetic enamel paint complete all as specified
Preparation of old surfaces plastered or unplastered ,brooming down or steel wire brushing etc and applying one coat of oil emulsion distemper/OBD of approved tint on old decorated surfaces of walls include comices by using roller/spray machine over avg 2 mm thick wall care putty as desired smoothening of surfaces complete all as specified and as directed by Engr-in-Charge
M&L for preparation of new surfaces plastered by brooming down or steel wire brushing scraping down oil & greasy spots etc and applying one coat of priming with chalk whitning, and applying three coats white wash on ceiling of approved tint over new plastered surfaces etc all as specified and directed by Engineer-in-Charge.
M&L for preparation of new surfaces plastered by brooming down or steel wire brushing scraping down oil & greasy spots etc applying one coat of priming with chalk whitning and applying two coats of acrylic distemper/OBD paint of approved tint over avg 2 mm thick wall care putty over new plastered surfaces etc all as specified and directed by Engineer-in-Charge.
Preparation of old surfaces plastered or unplastered , brooming down or steel wire brushing etc and applying one coat of white wash on old decorated surfaces of ceiling include cornices complete all as specified and as directed by Engineer-in-Charge
M&L for for complete removal of existing treatment on walls etc, by scraping, sand papering or by using mechanical sander and preparing plastered surfaces and applying one coat of exterior acrylic emulsion paint (weather coat ) of approved tint on walls over a coat of wall primer and a coat of putty by using roller/spray machine complete as specified and as directed by Engineer-in-Charge
M&L for RCC pillarrs in PCC 1:2:4 type B-1 set in cement mortar 1:4 moulded 100 x 100mm x 75cm long precast complete fixed and specifed and as directed by Enginer-In-Charge.
Providing cement concrete RCC jalli 35mm thick type B0 1:2:4 using 12.5mm graded aggregate (measured solid) including all mouldings but exc frame,set in CM (1:4) including dismantling old jallis all as specified.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade to IS 15658-2006 manufactured using grey cement and pigment complete all as spcified and directed.
M&L for 25 mm thick sand filling under floors, cushning under interlocking tiles or in foundations complete all as specified and directed.
M&L for PCC (1:4:8) type D2, using 40mm graded stone agg as in mass filling and fdn,sub base under Interlock etc. complete all as specified and directed.
M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even complete.
M&L For PCC type B1(1:2:4) using 20 mm graded cushed stone agg as in coping ,benching and the like incl form work
M&L for preparation of new surfaces plastered by brooming down or steel wire brushing scraping down oil & greasy spots etc applying one coat of priming with chalk whitning and applying two coat of exterior acrylic emulsion paint (weather coat )of approved tint over new plastered surfaces etc over a coat of putty all as specified and directed by Engineer-in-Charge.
Dismantling Brick tiles or terracing tiles,single layer on roofs all as specified and directed.
Demolition of lime Concrete to any thickness in any position incl all topping thickness (below or above ground level).
Demolition cement concrete unreinforced of any description and in any position not otherwise specifically provided.
Taking down cement plaster, any description on brick or stone or cement concrete walls including any tiles and raking out joints, hacking for key, scrubbing down with water complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), all as specified and directed by Engineer-in Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), all as specified and directed by Engineer-in Charge.
Demolition of brick/stone masonry built in CM. all as specified.
Demolition of reinforced cement concrete to any thickness as in slabs, beams incl cutting of reinforcement as reqd at site.
Taking up or down steel tubing 20 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified
Dismantling cast iron /PVC pipes fixed to walls or laid in trenches in any position.
Taking up or down steel tubing 25 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr In Charge
M&L Brick work with fly ash bricks straight or curved on plan to any radius built in CM 1:4 all as specified.
M&L Half Brick work with fly Ash bricks straight or curved on plan to any radius built in CM 1:4 all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified.
M&L for Rendering 15 mm thick in two layers on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately).
M&L for Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified.
M&L for Rendering 5 mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified.
Dismantling water tanks and removing to store exc 250 ltrs and n exc 500 ltrs
Providing and laying of protective Geotextile fabric 150 GSM over the entire membrane with proper overlaps of 75 mm before laying SRI Roof tiles omplete all as specified and directed by Engr-in-Charge.
M&L Vitrified ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in floors ,area of each tile exc 0.18 sqm but n.exc. 0.38 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, over and including 15 mm thick screed plaster in CM 1:6 complete all as specified and directed
M&L Vitrified ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in skirting ,dados etc. area of each tile exc 0.18 sqm but n.exc. 0.38 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 10 mm thick screed plaster in CM 1:4 complete all as specified and directed
M&L Non skid Ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular ) in floors ,area of each tile exc 0.11 sqm but n.exc. 0.18 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, over and including 15 mm thick screed plaster in CM 1:6 complete all as specified and directed by Engr In Charge
M&L for providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection finished even and smooth without using extra cement
S & F Mild steel framed work such as grills, gratings, tank staging etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks, cooler stand and similar work conforming to Fe 290 Gd E-165 all as specified .
M&L Baroda Green marble,machine cut as in shelves/steps/landing/cills/jambs/skirting/border etc. or similar ,15-16 mm thick with granite polishing bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of stone including cutting, rounding to edges and polishing etc. over 15 mm screed bed in CM(1:4) Complete all as specified and directed. Single piece should be used in steps/cills/jambs/shelves.
M&L for MS TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L for MS TMT bars 6mm to 8mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L for MS TMT bars 5 mm to 10 mm dia in reinforcement, cut to length, bent to shape required as in stirrups and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L for reinforced cement conc M-25 design mix as in slab supported on walls , beam, and columns in floors,roofs landings , balconies etc.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete, all as specified .
Supply only liquid water proofing compound complete all as specified.
Cleaning of surface of loose dust and grit and cement slurry etc. by means of wire brush dust removing and scrapper etc .Pot holes/cracks shall be repaired with cement admixed with polymer as per manufacturer instructions complete all as specified and directed by Engg In Charge.
Providing PCC coving /gola along vertical parapets of size 75 mm x 75 mm with concrete mix (1:2:4) type B1 using WPC of approved make etc complete all as specified and directed by Engg In Charge.
The surface shall be treated with PU Elastoseal primer with Epoxy primer to seal the pores and enhance the adhesion of the coating,supplying and applying single component waterproofing liquid membrane based on pure,elastomeric,polyurethane resin cold applied of spray/brush applied membrane with an elongation of (650%+,- 50 ) and tensile strength not less than 2 Mpa ,crack bridging ability not less than 2 mm.No leakage upto 5 bars of water pressure.shore hardness > 50 shore. The Minimum thickness to be applied shall be 1.5 mm,( overall )in two layers (each layer 750 micron) or as per manufacurer's instructions so as acheive thickness not less tha 1.5 mm complete all as specified and directed by Engg In Charge.
Providing and laying of protective Geotextile fabric 150 GSM over the entire membrane with proper overlaps of 75 mm before laying SRI Roof tiles complete all as specified and directed by Engg In Charge.
Providing and laying SRI (Sun Resistance Index ) roof tiles (size 300x300x9-10 mm) with 20 mm thick cement plaster in CM (1:4) mixed with liquid WPC as per manufacturer's instructions confirming to required slope complete all as specified and directed by Engg In Charge. Note :- For Roof Treatment process Make of PU Primer /Membrane :- SIKA/BASF,BERGER/STP FOSROC/ SAINT GOBIN /PIDILITE
S&F for factory made single extruded WPC ( Wood polymer composite) solid door /window/ceosetory windows& other Frames/Chowkhat of size 65x100 mm compraising of virgin PVC polymer of K value 58-60 ( Suspension grade),calcium carbonate and natural fibers (wood powder/rice husk/wheat husk ) and non toxic additives ( maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum,screw withdrawal strength of 2200 N(face) & 1100 N ( Edge),minimum compressive strength of 58 N/mm2,modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fastners of required dia and length complete as per direction of Eng In charge .( MS holdfast / lugs dash fastners shall be included in unit rate of item). Note:- For WPC solid door/window frames,minus 5 mm toletance in dimension i.e. depth and width of profile shall be acceptable .Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Form work to edges of concrete flats, breaks ,conc railing nexc 200mm wide finished roughthick
S&F for factory made single extruded WPC ( Wood polymer composite) solid plain flush door shutter of size 30 mm thick compraising of virgin PVC polymer of K value 58-60 ( Suspension grade),calcium carbonate and natural fibers (wood powder/rice husk/wheat husk ) and non toxic additives ( maximum toxicity index of 12 for 100 gms ) having minimum density of 650 kg/cum,screw withdrawal strength of 1800 N(face) & 900 N ( Edge),minimum compressive strength of 50 N/mm2,modules of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixing with Stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws ,complete as per direction of Eng In charge . Note:- SS butt hinges and SS screws shall be included in unit rate of item.
Ditto as above but of frame size 65 x 125 mm
S&F for 100 mm Stainless steel Butt hinges
S&F for 150mm Stainless steel handles.
S&F SS sliding door bolt, length 250 mm nuts and washers all as specified
S&F 300mm, ordinary rat tail rod patttern springs including roller and roller plate complete all as specified and directed.
S&F PVC(SWR) bends any radius 110mm bore
Ditto as above but skelton door shutter of size 30 mm thick
S&F for 150mm size Stainless steel barrel tower blots all as specified and directed.
S&F factory made mild steel Window box type with side huge shutters incl pintol hinges,steel handles, steel peg stay and all locking arrangement and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEBTZ/TD/888R & 889 ii) MS fillets, glazing, wire gauge shall be measured and paid separately iii) opening incl provn shutter for cooler to be provided as directed
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares n exe 0.5 sqm each pane all as specified
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor overall length of cover plate 150 mm complete all as specified and directed.
S&F 3 mm thick Frosted glass ordinary quality and glazing with oil putty in squares n exe 0.5 sqm each pane complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Each Job
Supply and laying of CPVC pipes (outer dia 22 mm) SDR 11 pipes & plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete all as specified and directed by Engr In Charge
S&F factory made mild steel Ventilator box type with upper top hung shutters and bottom fixed type shutters including pintol hinges,steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEBTZ/TD/888R & 889 ii) MS fillets, glazing, wire gauge shall be measured and paid separately
S&F 500 ltr Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including PTMT Ball valves, high pressure, with epoxy coated Al rod and high density plastic ball screwed for pipe and fixed
S&F in repair 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed
S&F Vitreous China Squatting pan `Orissa pattern` size 550x440mm including integral foot rest, incl P or S trap comp all as specified and fixed in repairs.
S&F in repairs vitreous China pedestal pattern white,(excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed by Engr In Charge
S&F in repairs PVC flushing cistern 10 ltrs capacity incl flushing pipe and connections complete. as approved by Engineer in charge,low level, white with inlet, ball valve ,complete including connection to pipe all as specified.
S&F in repair 20 mm dia mild steel curtain rod chromium plated incl brackets, stops etc. complete all as specified and directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand including brackets & waste pipe etc complete all as specified.
S&F in repair 15 mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified.
S&Fin repair 15mm bore PVC connection with PTMT nuts length 450 mm complete all as specified.
S&F in repair fancy type chromium plated stop valve/Angle valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15 mm. complete all as specified.
S&F in repair Brass chromium plated shower rose 125 mm size with and incl shower arm complete all as specified.
S&F in repair chromium plated long body Bib Tap, with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule, fancy type, CP, 15mm dia
S&F in re
pair 15 mm bore brass fancy concealed type stop valve chromium plated with long shank and cup complete screwed for iron pipe complete all as specified.
S&F in repair Towel Rail 600 mm long of CP with and incl chromium plated brass screws and wooden /plastic cleats
S &F in repair 5 mm thick mirror of size 450mm x600mm mounted on 6mm thick commercial ply wood backing and secured with PVC channel alround complete all as specified.
S&F in repair soap dish complete all as specified and directed by Engr In Charge.
S&F in repair 32 mm size cp waste coupling (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) incl waste pipe complete all as specified.
S & F PVC(SWR) bends any radius 110mm bore complete all as specified and directed by Engr In Charge.
S & F PVC(SWR)single socketed in any length with rubber ring joint fixed with wall of 110mm complete all as specified and directed by Engr In Charge.
S&F cast iron soil, waste and vent pipes (sand cast) 100mm bore in any length with or without ears with cement joints laid in trenches complete all as specified and directed by Engr In Charge.
S&F cast iron soil, waste and vent pipes (sand cast) 100mm bore in any length with or without ears with cement joints fixed to wall including suitable stack clamps complete all as specified and directed by Engr In Charge.
S&F cast iron soil, waste and vent pipes (sand cast) 75mm bore in any length with or without ears with cement joints laid in trenches complete all as specified and directed by Engr In Charge.
S&F cast iron soil, waste and vent pipes (sand cast) 75mm bore in any length with or without ears with cement joints fixed to wall including suitable stack clamps complete all as specified and directed by Engr In Charge.
S&F cast iron soil, waste and vent pipes (sand cast) 50mm bore in any length with or without ears with cement joints fixed to wall including suitable stack clamps complete all as specified and directed by Engr In Charge.
S & F in repairs health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engr In Charge
S&F cast iron vent cowl for 50 m dia pipe complete all as specified and directed by Engr In Charge.
S&F Cast iron bend (any radius) diminishing pieces or tapers/ Reducers/ Sockets 100mm bore fitted with oval access door complete all as specified and directed by Engr In Charge.
M&L for Extra over cast iron pipe and fittings if lead joint is provided in lieu of cement joint for 75 mm bore complete all as specified and directed by Engr In Charge.
M&L for Extra over cast iron pipe and fittings if lead joint is provided in lieu of cement joint for 100 mm bore complete all as specified and directed by Engr In Charge.
S&F cast iron Branch pieces, single (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches/ Junction box 100 mm bore fixed in repair with oval access door complete all as specified and directed by Engr In Charge.
M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer.
S&F cast iron Branch pieces, single (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches/ Junction box 75 mm bore fixed in repair with oval access door complete all as specified and directed by Engr In Charge.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width and grith and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
coat of synthetic enamel paint complete all as specified
Preparation of old surfaces plastered or unplastered ,brooming down or steel wire brushing etc and applying one coat of oil emulsion distemper/OBD of approved tint on old decorated surfaces of walls include comices by using roller/spray machine over avg 2 mm thick wall care putty as desired smoothening of surfaces complete all as specified and as directed by Engr-in-Charge
M&L for preparation of new surfaces plastered by brooming down or steel wire brushing scraping down oil & greasy spots etc and applying one coat of priming with chalk whitning, and applying three coats white wash on ceiling of approved tint over new plastered surfaces etc all as specified and directed by Engineer-in-Charge.
M&L for preparation of new surfaces plastered by brooming down or steel wire brushing scraping down oil & greasy spots etc applying one coat of priming with chalk whitning and applying two coats of acrylic distemper/OBD paint of approved tint over avg 2 mm thick wall care putty over new plastered surfaces etc all as specified and directed by Engineer-in-Charge.
Preparation of old surfaces plastered or unplastered , brooming down or steel wire brushing etc and applying one coat of white wash on old decorated surfaces of ceiling include cornices complete all as specified and as directed by Engineer-in-Charge
M&L for for complete removal of existing treatment on walls etc, by scraping, sand papering or by using mechanical sander and preparing plastered surfaces and applying one coat of exterior acrylic emulsion paint (weather coat ) of approved tint on walls over a coat of wall primer and a coat of putty by using roller/spray machine complete as specified and as directed by Engineer-in-Charge
S&F Cast iron bend (any radius) diminishing pieces or tapers/ Reducers/ Sockets 75mm bore fitted with oval access door all as specified.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade to IS 15658-2006 manufactured using grey cement and pigment complete all as spcified and directed.
M&L for 25 mm thick sand filling under floors, cushning under interlocking tiles or in foundations complete all as specified and directed.
M&L for PCC (1:4:8) type D2, using 40mm graded stone agg as in mass filling and fdn,sub base under Interlock etc. complete all as specified and directed.
S&F 75 mm bore CI floor trap plain with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engr In Charge.
Structural design for roof slab, beams, chajjas and other connected RCC members required to be reconstructed under this schedule with & including vetting of structural design from approved Govt Engineering College/NITTTR/CBRI, complete all as specified and as directed: Notes: (i) Tenderer shall cary out the site visit to ascertain the size of slab, other RCC members, arrangement of rooms, etc required for design purpose. (ii) Four sets of structural drawing shall be provided to GE by Contractor duly vetted as above.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width & girth & applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even complete all as specified and directed by Engr In Charge.
Returning filling in incl spreading levelling watering and well ramming in layers n exc 25cm thickness complete all as specified and directed by Engr In Charge.
Excavation in trenches n exc 10 Sqm on plan n exc 1.5 m deep and n exc 1.5 m wide , getting out in any type of soil.
Removing excavated soil to a distance n exc 50m and depositing at alevel n exc 1.5m above the starting point complete all as specified and directed by Engr In Charge.
M&L for conc 1:3:6 type C2 using 40mm graded aggregateas in bed to 150mm drain pies incl packing under and haunching against the sides of pipes after they are laid and tested for complete all as specified and directed by Engr In Charge.
M&L for DWCPE pipe 150 mm dia laid in trenches ,Jointing incl testing along with necessary fittings , complete all as per manufactrers instructions including dismantling old pipe of any type complete all as specified and directed by Engineer-in-charge.
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed.
Supply and laying of CPVC pipes (outer dia 25 mm) SDR 11 pipes & plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete all as specified and directed by Engr In Charge
Taking down old U/S existing DB SPN 8 way & TPN DB 4 way including MCB/MCCB/Industrial plug socket of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Disconnecting and taking down unserviceable submain wiring form TPN DB to SPN DB and SPN DB 8 way / SPN DB 4 Way complete & removing U/S items from site complete all as directed by Engineer-in-Charge.
Taking out carefully earthing set complete of any type including earthing wire & removing U/S items from site complete all as directed by Engineer-in-charge. complete all as specified and directed by Engineer-in-charge.
M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colour to coomon earth dolly laid/drawn into and including non metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed: Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE
One multi pin socket 5/6Amps, Independent.
One light/fan point (Ceiling Fan/Exhaust Fan) controlled by one switch
M&L brick work in cement mortar (1:4) using old size sub class 'B' bricks in walling, straight or curved on plan exc 6m mean radius complete all as specified and directed by Engr In Charge.
M&L For PCC type B1(1:2:4) using 20 mm graded cushed stone agg as in coping ,benching and the like incl form work complete all as specified and directed by Engr In Charge.
All as per item No 186 here -in- before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 sqmm single core PVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed .
All as per item No186 here -in- before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 sqmm single core PVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed .
S&F switch Modular type, 5/6 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.
S&F switch Modular type, 15/16 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.
S&F socket outlet 3 Pin 5/6 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.
S&F socket outlet 3 Pin 6/16 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.
Supply and hanging/fixing ceiling fan 1200mm sweep AC supply (input voltage range 120 to 280v), BLDC type, 5 star rated BEE and ISI marked, super enameled copper winding of 'B' class insulation, single phase 20 watt (+ 10%), PF 0.90 (MIN), air delivery of 220 CUM per min (CMM), 350 RPM (+ 10%), TEMP RISE 40 DEGREE MAX, without remote, with electronic regulator, 3 blades, down rod including accessories, total harmonic less than 10%, 5 speed, hanging in position, including making connection wih and including flexible cord twin core twisted copper conductor of size 23/0.0076 from cealing rose to fan complete all as specified and as directed. Note :- (i) Sl No of cealing fan and GE office name shall also be writing on fan with red colour permanant marker. Cost for the same shall deemed to be included in quoted unit rate. Nothing shall be paid extra on this account.
Supply and fixing fan step regulator modular type,120W -2 module electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
Taking down LED tube light fitting, 1x 20 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.
Refixing LED tube light fitting, 1x 20 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete a
ll as specified and as directed by Engr-in-Charge.
Supply and fixing LED Bldg Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F GI bracket made out of 40 mm bore GI pipe light grade /medume grade, ISI marked, medium grade 1.2m long bent to shape suitable for fixing of street light fitting including with 2 Nos MS clamps made with 40x3mm flat iron, bolts, nuts, washers etc including two coats of synthetic enamel paint over one coat of zinc chrome primer and fixing on electric pole complete all as specified and as directed by Engr-in-Charge.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S&F double door, sheet metal enclosure, powder coated for MCB DB TPN DB 4 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S&F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S&F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S&F MCB TPN 40-100 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
M & L Glazed ceramic coloured tiles of size (300x450 )mm x 7/8 mm thick on vertical surface as in dados, skirting etc, set and jointed in neat cement slurry over and including 10mm thick plaster in cement mortar 1:4, pointed with white/ coloured cement to match complete all as specified and directed by Engr-in-Charge
S&F in of sheet metal enclosures with socket, plug top complete with one single pole MCB -240 Volt- 20 AMP complete all as specified and as dircted by Engr-in-charge.
M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colour to coomon earth dolly laid/drawn into and including non metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed: Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE
M&L for submain wiring with 2 runs of 6.0 Sqmm (nominal area) size main cable & 1 runs of 6.0 Sqmm size earth continuity conductor single core PVC insulated unsheathed FRLSH multistranded copper conductor 1100 volt grade ISI marked cable drawn through & including suitable size of heavy duty non metalic rigid PVC concealed conduit ISI marked & conduit fittings/accessories, fixede concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified & directed. Note :-(i) 02 runs of 6.0 Sqmm size main cable, 01 run of 6.0 Sqmm size earth continuity conductor cable & Conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall be included in quoted rate of this item.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 2.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colour to coomon earth dolly laid/drawn into and including non metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed: Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE
One3 pin 5 amps socket on same board.
Taking down old unserviceble fan regulator from site complete a as specified and directed.
One3 pin 5 amps socket on Independent board.
All as per item No 210 here -in- before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed .
Taking down fan, sealing cable end, dismantling ades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing o ceilling fan, cleaning all dust & painting with existing colour synnthetic enamel paint by complete all as specified and directed .
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fitting ISI marked complete all as specified and directed.
S&F LED Bulb 9W, operating voltage 220-240 volts, startng time<0.5 s, color temperature-6500K, lumens: min 825 complete all as specified and directed by Engr-in-Charge
S&F double door, sheet metal enclosure, powder coated for MCB DB SPN 4 way fited wit neutral link, earth bar, din rail and 200 amps rated bus bar 230 volt conforming IS 13032-1991 complete all as specified and as directed by Engr-in-Charge.
S&F sheet metal encloure MCB DB double door, TPN 4 way wit 200 amps rated busbar all as specified and as directed by Engr-in-Charge.
M&L for submain wiring wit two single core 4.00 Sqmm size earth continuity conductor single core PVC insulated unsheathed FRLSH multistranded coper condctor 1100 volt grade ISI marked cable drawn through & including suitable zize of heay duty non metalic rigid PVC concealed condit fittings/accessories, fixede concealed in wall/ceiling including dismantling & taking down old unserviceable sb main wiring complete all as specified & directed. Note :- (i) Two run of single core and one rn earth wire, PVC Conduit will be measured as one length. (ii) Cost of cutting/leaving forming chases for condits and making good in CM 1:4 shall be included in quoted rate of this item.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Gen39_All_Tender_Docu.pdf
Tender Documents • 1.51 MB
BOQ_832296.xls
BOQ • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .