| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹34.6 L+₹3.3 L (10.5%)Rejected-Finance 712 GORAKHPUR JABALPUR 482001 MP | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹37.8 L+₹6.5 L (20.7%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹38.0 L+₹6.7 L (21.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹38.6 L+₹7.3 L (23.3%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
31 Oct 2020, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
CERTAIN PETTY REPAIR AND REPLACEMENT OF INTERNAL WIRING, MCBS DBS FITTING, FIXTURE, SUB MAIN AND OTHER CONNECTED WORKS AND OTHER CERTAIN MISC UNDER GE (WEST) JABALPUR
2020_MES_382984_1
8275/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (West) Jabalpur
As per Tender document
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹96,000
2 Dec 2020
3 Oct 2020
2 Nov 2020
3 Oct 2020
31 Oct 2020
17 Oct 2020
5 Oct 2020 - 15 Oct 2020
Amount
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge.
Taking down carefully main switches / distribution boards complete of any size and refixing after repair and MCBs SP /SPN or Cut out of any size all as required and directed at site
Taking down carefully and re-fixing ceiling light 2x2 or 1x1 after rerpair of required items and replacemnt of wire all as required and directed at site
Taking down carefully and re-fixing light fitting /tube light fitting and repalcemnt of items as required with replacemnt of wire after repair of required items all as required and directed at site
Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 2.5 sqmm copper conductor cable drawing into pvc conduite and jointing properly etc all as required and directed at site
Repair the sub main wiring with detecting the fault and repair the point after replace the u/s wire of 4 sqmm copper conductor cable drawing into pvc conduite and jointing properly all as required and directed at site
Repair to point wiring with taking out the fault removing the u/s / brunt wire and repair with repalacemnt of wire jointing properly with connector and making the point serviceable (replacemnt of wire not more then 1 mtrs, junction box cover / connection of point is included in the cost of repair) and maKing the point serviceable all as requird and directed at site
M& L for comprehensive maintenance and repair to point wirring with taking out fault in the wirring and reapir to the point wring and mamking the point wiring serviceable including following works (a) Checking proper working of wiring light or fan point (b) Checking of socket point/switch /holder point including replacement of unseviceable part (c) Replacement of unserviceable baten holder/ tube light/lamps/ ballast/bipin holder /fittings (d) Cleaning of tube light fitting and repalcements of starter ( e). Note : 1.Contractor has to depute one electricians daily who will report to JE /Fan incharge. 2 Unserviceable parts to be measured & paid seperately under relevant item of Sch A..3.All T & P and ladder provide to electrician at site by The contractor.
S&F in replacement Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6.0 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run
S&F in replacement Sub main wiring with two single core PVC Insulated cable two run of size 4.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 2.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 4.0 Sqmm & one run of 2.50 Sqmm cable shall be measured as one unit run
S&F in replacement Sub main wiring with four single core PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 10.0 Sqmm & one run of 6.0 Sqmm cable shall be measured as one unit run.
S&F in replacement Sub main wiring with four single core PVC Insulated cable four run of size 10.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 32 mm dia with all conduit accessories and two run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Four run of 10.0 Sqmm & two run of 6.0 Sqmm cable shall be measured as one unit run.
S&F in replacement Sub main wiring with two single core PVC Insulated cable two run of size 2.5 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 2.5 Sqmm & one run of 1.5 Sqmm cable shall be measured as one unit run.
Supply & fixing in repair 25 mm dia non mettalic Rigid PVC conduit, ISI Marked conforming to IS : 9537 medium grade Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed.
Supply & fixing in repair 32 mm a non mettalic Rigid PVC conduit, ISI Marked conforming to IS : 9537 medium grade Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed.
Supply & fixing in repair 20 mm non mettalic Rigid PVC casing caping conduit, ISI Marked Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including fixing on wall and making good the disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed.
Material & Labour for concealed Point wiring with PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into and including concealed PVC conduit medium grade not less than 20mm (ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup washers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge.
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket point 5 Amp controlled by one switch on same board.
(d) One socket point 5 Amp controlled by one switch on Independent board.
(e) One socket point 5 Amp controlled by one switch on Independent board below the switch board.
(f) One bell point controlled by one bell push button independent board.
(g) One light point controlled by two way switch.
Ditto all as per above items but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Ditto all as per above items but with 1100 Volts grade copper stranded conductor FRLS cable of size 4.0 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Material & Labour for point wiring with PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover or inner outer plate for modular switches/socket for mounting switches, sockets, fan regulators fixed with CP screws with cup wahssrs and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge.
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket point 5 Amp controlled by one switch on same board.
(d) One socket point 5 Amp controlled by one switch on Independent board.
(e) One socket point 5 Amp controlled by one switch on Independent board below the switch board.
(f) One bell point controlled by one bell push button independent board.
(g) One light point controlled by two way switch.
Ditto all as per above items but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Ditto all as per above items but with 1100 Volts grade copper stranded conductor FRLS cable of size 4.0 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
M&L for drawing the wire in with casing caping complete with point wiring with FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -Make of wire -Finolex/plaza/gloster
(i) One light point point controlled by one way, single pole switch
(ii) One light one fan point controlled by one way, single pole switch
(iii) One 3 pin socket outlet, 6 Amp on “independent board” but below/side the switch board of the light point in same vertical plane.
(iv) One 3 pin socket out let, 6 amps on the "same board" with other switches
(v) One 3 pin socket outlet, 6 Amp on “independent board”
(vi) One bell / buzzer point controlled by one bell push
(vii) do but one light point controlled by two way switch
Ditto all as per above items but drawing in with casing caping point wiring using 2.5 Sqmm (Nominal area)triple layer FRLSH PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
Supply & Fixing Modular Switches 5 /6 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Switches 15 /16 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Sockets 6 amps 3/5 pin with fixing arrangements all as required and directed at site
Supply & Fixing Modular Sockets 15/16 amps 5/6 pin with fixing arrangements all as required and directed at site
Supply & Fixing Ceiling Fan regulator modular electronic ROTARY / Step type 80/120 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed.
Supply & Fixing Modular bell push switches 5 /6 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Switches 5 /6 AMPS single pole two way with fixing arrangements all as required and directed at site
Supply & Fixing switch piano flush button type single pole one way 5 Amps of polycarbonate complete all as specified & directed.
Supply & fixing of call bell ding dong sound type suitable for AC 240 volt single pole complete all as specified & directed.
Supply & Fixing switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
Supply & Fixing socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed.
Supply & Fixing Switch socket combination 2 in 1, 3 pin / 5 Amp and 15 Amps flush type universal of polycabonate body complete all as specified & directed.
Supply & Fixing lamp holder / batten or angle holder Insulated body with back plate suitable for batten fittings complete all as specified & directed.
Supply & Fixing 9 Watt capacity LED lamp fixed in lamp holder complete all as specified & directed.
Supply & Fixing Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed.
Supply & Fixing Ceiling Fan regulator electronic ROTARY / Step type 100 / 120 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed.
Supply & Fixing in repair 22 watt LED tube light fitting four feet long box type high efficiency aluminum linear batten type along with fixed on surface / wall or Pendent mounting Luminaires connector block etc, with all accessories internally pre-wired and connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified & directed. Make : philips 0211LED 22 S 6500/4000psugr/SI OR OSHRAM
S&F in repairs LED Decorative /mirror light fitting 9 watt along with fixture Surface mounted suitable for indoor aplication , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. Make Surya Cat No SLE BT 10 W OR havells Cate no LUMILINEBS9WLED830SPCWH LUMIN Luker code no LMR 10 or Wipro or equvalent philips/syaska
Supply and fixing in replacement of decorative wall light fitting WITH LAMPS 9 WATT made up of Polycarbonate , , Cylindrical shape , with LED lamp complete with fixing arrangements on wall all as specified and directed. make CITY 1 OF HAVELLS /luker light code no LWL-110-2 or equivalent OR equivalents Bajaj/Philips/CG as approved by GE(I)
Supply & Fixing in replacement Ceiling light round shape surface mounted LED 10/12 WATT with dome shape opal diffuser compelete with fixing all as required and directed at site with copper conductor of suiyable size & length complete all as specified & directed. Make : Bajaj cat no BCCML12W WH /SURYA CAT NO SLEDLS 12WXX OR Havells Cat Part No.INTEGRANEOSURFACEDLS10WLED830S Equivalent make & model in Philips / Crompton
Supply & Fixing in replacement Bulk head endura LED light fitting complete with10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suiyable size & length complete all as specified & directed. Make : Havells Cat Part No. RUGBY NEONFT10WLED760SSYMBOP/ BIBWP10W LED OF bAJAJ Equivalent SURYA SLEBLH 10 / Philips / Crompton
Supply & Fixing in repalcement of recess mounted CRCA LED 600x600mm with maximum power consumption of 33W and minimum output of 3600 Lumens at system level. CRI>80 @ 6500 K CCT. Product should have 2 diffuser sheets one should be a PS diffuser and other should be a prismatic diffuser for UGR<19. Life class of 50,000 burning hours @ L70,B50 @45 degree ambient. Supplied with LED Driver with operating voltage 140-277V AC, P.F.>=0.95, THD<10% and ripple less than 5% (flicker free). LED Driver should have 4KV inbuilt surge protection with auto cut-off above 325 V AC and auto restart feature. LED Driver should be EMC/ EMI Compliant. with biological human safty certification Similar to Philips RC380B LED30S-6500 G5 L60W60 PSU OD SG/osram
Supply & fixing in repair 20 watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessories with and including 40 mm dia GI pipe light grade bracket fixed with 30x5 mm FI clamp with nut bolts & washers complete in all respect as specified & directed. mAKE bAJAJ CAT NO BRLEP20WLED V2 OR SURYA CAT NO SLEUL20W OR OR PHILIPS/CROMPTON
Supply & fixing in repair 45 to 50 watt watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessories with and including 40 mm dia GI pipe light grade bracket fixed with 30x5 mm FI clamp with nut bolts & washers complete in all respect as specified & directed. MAKE- SURYA CAT NO SLEUL45W OR BAJAJ CAT NO BRTFG 45W LED V2
Supply & fixing in repair 55 to 65 watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessories with and including 40 mm dia GI pipe light grade bracket fixed with 30x5 mm FI clamp with nut bolts & washers complete in all respect as specified & directed. MAKE SURYA CAT NO SLEUL 60 WATT /BAJAJ CAT NO BRTFG 60 WATT LED V3
S&F in replacement LED light fitting INDOOR TYPE of 15 to 18 watt along with fixture recessed slim LE luminaries mounting channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and direc tedy by Enginmeer in charge. Make SURYA CAT NO SLEDLR 15 W XX OR Havells Cat no Pulto1x1PLR15wlfd857s or Luker elegent slim panel LNPS30 or Wipro or philips/syaska
Supply & fixing in repair LED light down lighter die cast aluminum luminaire in powder coated white with drop down PC diffuser with optimised heat sink with repalaceable electronic driver complata recess or surface mounted 15 watt with fixing arrangemnts on ceiling with steel chain complete all as specified & directed. mkae SURYA CAT NO SLEDR 15 W STELER /Havells Cat No RISEDLR15WLED83OS or Bajaj/Philips make
S&F in repairs Recess/ Surface mounted IP20 PIR movement detector with a built-in switch for lighting. It should be able to take lighting load of 6A. It should control office area of around 20sq.mtr for small movement and 50sq.mtr for large movements. It should have smart daylight sensing for additional savings through daylight override and daylight switching. It should have timer knob (1 to 30 min setting) and light detection knob (100 to 1500 Lux setting) on the bottom face for ease of controlling after installation as well. Smart timer should extend the delay time by 10 mins if movement is detected shortly after switch-off. It should have a retractable shield. Operating temperature +5 to +50 Degree Celsius. It should have EMC compliance IEC (EN) 60669-2-1, Immunity IEC (EN) 61547 And Immunity IEC (EN) 55015 & IEC (EN) 55022, Class B. Max power consumption of 1.2W at standby. Make Philips LRM1071 or Bajaj/ Crompton
Supply & fixing in replacement electronic energy meter tamper proof design digital technology of three phase 3 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site make HPL socomec model PPEM 01 or equivalent in Havells or as approved by GE.
Supply & fixing in replacement electronic energy meter tamper proof design digital technology of SINGLE phase 1 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site make HPL socomec model PPEM 02 or equivalent in Havells or as approved by GE.
Taking out old Unserviceable meter of any capacity after disconnecting the electric connection and refixing the electric meter new or old as directed of any capacity and making necessary electric connection and sealing the same with sealign wire and lead seal complete all as directed at site.
Supply & Fixing in replacement sheet metal enclosure MCB DB double door , Vertical Triple pole and neutral [VTPN], 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar, Din rail earth bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO 507745 / siemens/ GE
Supply & Fixing in replacement sheet metal enclosure MCB DB double door, Triple pole and neutral, 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and DB double door IP 43 protection with insulated bus bar with tested 10 KA braking capacity complete all as specified & directed. Make : Legrand CAT NO 507640 / SIEMENS CAT NO 8GB32203RC04 / GE
Supply & Fixing in repair sheet metal enclosure MCB DB double door, single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and DB double door IP 43 protection with insulated bus bar with tested 10 KA braking capacity complete all as specified & directed. Make : Legrand CAT NO 507610 /SIEMENS /ABB / Schinider
Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required andDB double door IP 43 protection with insulated bus bar with tested 10 KA braking capacity complete all as specified & directed. Make : Legrand CAT NO 507611 / sIEMENS CAT NO 8 GB 32102RC8/GE
Supply & Fixing in repair sheet metal enclosure MCB DB double door single pole and neutral, 240 volts, 12 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and DB double door IP 43 protection with insulated bus bar with tested 10 KA braking capacity complete all as specified & directed. Make : Legrand CAT NO507612 / SIEMENS CAT NO 8GB32203RC12/GE
Supply & Fixing in repair MCB Triple Pole and Neutral 63 Amps, MCB shall be of 10 KA breaking capacity ‘C’ characteristic as per IS – 8828 of 1996 with fully safety shutters transparent label holder air circulating channels Bi-contact terminal dual position DIN rail, clamps, enclosure and items inside enclosure shall be of similar complete all as specified & directed. Make : Legrand DX3 TPN C 63A AC 408683 / Siemens cat no- 5SL44637 RC / GE
Supply & Fixing in repair MCB double pole 230Volt, 32 Amps,MCB shall be of 10 KA breaking capacity ‘C’ characteristic as per IS – 8828 of 1996 with fully safety shutters transparent label holder air circulating channels Bi-contact terminal dual position DIN rail, clamps, enclosure and items inside enclosure shall be of similar complete all as specified & directed. Make : Legrand DX3 DP CAT No 408636/ Siemens cat no- 5SL 42327RC / GE
Supply & Fixing in repair MCB Double Pole and Neutral 240Volt, 63 Amps, MCB shall be of 10 KA breaking capacity ‘C’ characteristic as per IS – 8828 of 1996 with fully safety shutters transparent label holder air circulating channels Bi-contact terminal dual position DIN rail, clamps, enclosure and items inside enclosure shall be of similar complete all as specified & directed. Make : Legrand Dx3 408639 / Siemens / GE
Supply & Fixing in repairs MCB Single Pole 240Volt, 6 to 32Amps, MCB shall be of 10 KA breaking capacity ‘C’ characteristic as per IS – 8828 of 1996 with fully safety shutters transparent label holder air circulating channels Bi-contact terminal dual position DIN rail, clamps, enclosure and items inside enclosure shall be of similar complete all as specified & directed. Make : Legrand cat no DX3 SP 408587,408590,408592,408593,408594,408595 / Siemens cat no- 5SL41067RC, 5SL41107RC, 5SL41167RC, 5SL41207RC, 5SL41257RC, 5SL41327RC / GE
Supply & Fixing in repairs RCBO double Pole 240Volt, 32 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411333 / Siemens / GE
Supply & Fixing in repairs RCBO four Pole 240Volt, 63 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411374 / Siemens / GE
Supply only self adhesive PVC electrical insulation tape,conforming to IS 7809, Part - 3, Section -1 and ISI Marked, of size as under :- (i) Length - 25.0 Metre (ii) Width - 18/19 mm (iii) Thickness - 0.125 mm Make - Steelgrip/Anchorgrip/Miracle as approved by GE(I)
Supply and fixing in replacement FR PVC insulated, Heavy duty, unsheathed single core flexible copper conductor cables of 1100 Volt grade, conforming IS 694 with latest ammendment and ISI marked in different colour of following sizes of make:Polycab//Indo Asian/Havells/Finolex/ National / HPL as approved by GE :-
Supplyand fixing in replacement metalised poly-propylene film capacitor as per IS 1569 for use in luminaires to improve power factor complete all as specified and directed of 4.0 Mfd capacity, 250VAC for 1 x 40 watt FTL fitting /ceiling fan and of Make - Epcos or its equivalent of Surya/Havells/CG/Siemens as approved by GE(I)
Supply and fixing in replacement metalised poly-propylene film capacitor as per IS 1569 for use in luminaires to improve power factor complete all as specified and directed of 2.50 Mfd capacity, 250VAC and of Make - Epcos or its equivalent of Surya/Havells/CG/Siemens as approved by GE(I)
Supply and fixing in replacement pressed MS/GI steel terminal boxes not less than 1.22 mm thick for mounting switch, socket etc of appx size 100 mm x 100 mm x 50 mm complete all as specified and directed.
Supply and fixing in replacement pressed MS/GI steel terminal boxes not less than 1.22 mm thick for mounting switch, socket etc of appx size 175 mm x 100 mm x 50 mm complete all as specified and directed.
Supply and fixing in replacement pressed MS/GI steel terminal boxes not less than 1.22 mm thick for mounting switch, socket etc of appx size 250 mm x 200 mm x 50 mm complete all as specified and directed.
Supply and fixing in replacement Hylam brand mica laminated 3 mm thick sheet cover of size 125mmx125mm complete with cutting for suitable size for fixing swiches/socket all as directed at site
Supply and fixing in replacement Hylam brand mica laminated 3 mm thick sheet cover of size 200mmx125mm complete with cutting for suitable size for fixing swiches/socket all as directed at site
Supply and fixing in replacement Hylam brand mica laminated 3 mm thick sheet cover of size 275mm x 225mm complete with cutting for suitable size for fixing swiches/socket all as directed at site
S&F in replacement of Mirror Light fittings white powder coated CRCA sheet housing with oppal acrylic diffuser cap with copper ballast and with 2 pin 11 watt CFL complete with fixing arrangement complete all as specified and directed. Make-Bajaj BJC 111 or equivalent of Havells/CG.
S&F in replacement the LED rechargeble emergency light slim ray sutable for 240 volts charging system complete with all respect all as required and directed at site make philips slim ray or equivalent bajaj
Supply only starter suitable for tube light 40 watt
Supply only bipin holder as per sample
Supply only angle holder backelit
Supply only ceilling rose 60x25mm
Supply only regulator dimmer type 60/80 watt
S&F in replacement lamp LED 12 watt
S&F in replacement lamp LED 8 watt etc complete all as specified and directed. Make crompton greaves/ Wipro/Philips/Havells/ Bajaj as approved by GE.
Supply & fixing in replacement FTL tube rod 36 watt 230 volts, AC , 50 Hz complete all as specified and directed Make crompton greaves/ Wipro/Philips/Havells/ Bajaj as approved by GE.
Supply & fixing in replacement LED tube rod 36 wat 3/4 pin type 230 volts, AC , 50 Hz complete all as specified and directed Make crompton greaves/ Wipro/Philips/Havells/Bajaj as approved by GE(I).
Dismantling & taking down unserviceable street light/security light fitting of fluorescent tube(1x 40 Watt),MV/SV fitting of 125/70 Wattage, CFL Luminaires of any type from existing pole/building from height not more than 6.0 Mtr from ground level for repair/replacement of worn out accessories and refixing at same location after making it serviceable including testing and connecting to street light feeder complete in all respect or as directed by Eng-in-charge.
Ditto all as per above item but taking down the U/S light fitting of SV/MV type of 150/250/400 Wattage or T- 5 Street Light luminaires - ditto - Note -Spare parts/service wire/control wiring required to make the light fittings serviceable shall be measured and paid separately as supply only under relevant items.
Supply only the following spare part/service wire/control wiring required to make the light fittings serviceable complete all as directed.
(i) Supply only commercial copper ballast for CFL/FTL lamps HF made of engineering plastic of PF>0.9 suitable for 36/40 watt FTL lamp at 240 VAC supply. Make Bajaj cat no BJHF 136 cat 169204 or eqvt wipro /philips/ crompton /surya
(ii) Supply only lamp holder porcline base with screw holder suitable for 150/250/400 lamp all as required and directed at site
(iii) Supply only Metal halide tubular lamp (single ended), Base cap - E 40 type of 150 Watt suitable for 240 VAC supply. Make Bajaj 150 T or surya cat no 250(T) or eqvt philips/bajaj/wipro
(iv) Supply only Metal halide tubular lamp (single ended), Base cap - E 40 type of 250 Watt, 6K suitable for 240 VAC supply. Make Bajaj 250 T or surya / philips/bajaj/wipro
(v) Supply only Metal halide tubular lamp (single ended), Base cap - E 40 type of 400 watt, 6K suitable for 240 VAC supply. Make Bajaj 400 MH or surya / havells/crompton/philips
(vi) Supply only open construction electromagnetic MH ballast consisting of silicon steel lamination with argon welding, super enamelled copper wire wound, vacuum impreganated with white resin, terminal block with tapping for 220/240 Volt AC Supply of 150 Watt suitable for Metal halide luminaires complete etc all as speciifed and directed. make Bajaj BJOS code 162109 or surya /bajaj/philips /wipro
(vii) Supply only open construction electromagnetic MH ballast consisting of silicon steel lamination with argon welding, super enamelled copper wire wound, vacuum impreganated with white resin, terminal block with tapping for 220/240 Volt AC Supply of 250 Watt suitable for Sodium/Metal halide luminaires copmlete all as speciifed and directed.Make Bajaj BJOS code162602 or Surya / bajaj/philips/wipro
(viii) Supply only open construction electromagnetic MH ballast consisting of silicon steel lamination with argon welding, super enamelled copper wire wound, vacuum impreganated with white resin, terminal block with tapping for 220/240 Volt AC Supply of 400 Watt suitable for Metal halide luminaires copmlete all as speciifed and directed. Make Bajaj BJOS code 169233 or Surya /Bajaj/Philips/Wipro
(ix) Supply only electronic ignitor for integral type luminaires type of 70/150/250/400 Wattage suitable for HPSV/MH Lamp upto 5 mtr striking distance complete all as specified and direct make - Bajaj or Wipro /Philips /Bajaj/CG as approved by GE(I).
(x) Supply only metalised poly-propylene film capacitor 20 MFD as per IS 1569 for use in luminaires to improve power factor complete as specified and directed of following capacity . Make - CG/Surya/Havells/Epcos/Siemens as approved by GE(I)
(xi) Supply only metalised poly-propylene film capacitor33 MFD as per IS 1569 for use in luminaires to improve power factor complete as specified and directed of following capacity . Make - CG/Surya/Havells/Epcos/Siemens as approved by GE(I)
S&F in replacement tube rod 14 watt complete all as specified and directed.
S&F in replacement rotary bipin holder sutable for tube light fitting rotary type etc all as specified and directed at site
S&F in replacement T-5 tube light 28 watt complete with repair the tube light fitting all as required and directed at site
S&F in replacement electronic ballast 28 watt suitable for T-5 lamps etc all as specified and directed at site
Supply & Fixing in replacement MCCB with thermal magnetic protection of 63 amps 415 volts 3 pole capacity complete all as specified & directed. Make : Legrand cat no DPX3 TP 420003 / Siemens/ GE/ABB
Supply & Fixing in replacement MCCB with thermal magnetic protection of 100 amps 415 volts 3 pole capacity complete all as specified & directed. Make : Legrand cat no DPX3 TP 420004 / Siemens/ GE/ABB
Supply & fixing in repair LED 20 watt lamp high efficiency linear lamp complete all as specified & directed.
Supply & fixing in repair LED 18 watt lamp high efficiency linear lamp complete all as specified & directed.
Supply & fixing in repair copper Ballast suitable for 36/40 Watt, 240 Volt tube light fittings complete all as specified & directed.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.
Supply & Fixing in repair tube rod 36 watt 240 volt fitted in tube light fiitings complete all as specified & directed.
Supply and fixing in repairs 36 watt 4 pin lamps complete etc all as required and directed at site
S&F the 36 watt ballast suitable CFL 36 watt lamps all as required and directed at site
Supply and fixing in replacement of decorative wall light fitting WITH LAMPS 9 WATT made up of Polycarbonate , , Cylindrical shape , with LED lamp complete with fixing arrangements on wall all as specified and directed. make CITY 1 OF HAVELLS /luker light code no LWL-110-2 or equivalent DECON/ or equivalent Bajaj/Philips/CG as approved by GE
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete.
M&L for Earthing complete with galvanised steel earthpipe of 3000mm long and 65mmouter x50mm inner dia laid in ground by drilling in the ground as required with filling the back fill compound complete with all as required and directed with 32x6 mm GI strip up to testing point and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed.Make HP earth or eqvt
M&L for Earthing complete with galvanised steel earthpipe of 3000mm long and 65mmouter x50mm inner dia laid in ground by drilling in the ground as required with filling the back fill compound complete with all as required and directed with 4 mm GI wire up to testing point and making the earth pit of PCC as per sample as required at site and testing after completion complete all as specified and directed.Make HP earth or eqvt
S&F in replacement romote bell Ac 230 volts with switch and battery and fixing on site etc all as specified and directed at site. Make : Havells/Anchor
Taking down and supplying & fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and over all PVC sheathed in service connection, one twin core 6 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and directed.
Taking down and supplying & fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and over all PVC sheathed in service connection, one twin core 10 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and directed.
Taking down and supplying & fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and over all PVC sheathed in service connection, one twin core 4 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and directed.
S&F in replacement blanking plate in any description
S&F in repairs bed side LED lamp light fitting 9/10 watt with lamp and glass etc complete all as per sample .
Supply & fixing in repair cubical board of meter box of size 750 mm x 500 mm x 150 mm with 1.6 mm thick CRCA sheet cover with fabricating of required size welding moulding of required shape with suitable hinging device & providing locking arrangement with & including Godrej pattern locks five lever 65 mm size having three keys fixed in meter box with cutting the sheet in square shape / size of 100mm x 100mm (06 Nos) with providing transparent fibre sheet for looking the meter from outside and painting steel surface with grey colour synthetic enamel paint over a coat of red oxide primer and fixed on wall with required nut, bolts grouting on wall and making holes for connections complete all as specified & directed.
Supply & fixing in repair Electronic Ballast suitable for 36/40 Watt, 240 Volt light fittings complete all as specified & directed.
Supply & fixing in repair Electronic Ballast suitable for 28 Watt, 240 Volt light fittings complete all as specified & directed.
Supply & Fixing in repair tube rod 28 watt 240 volt fitted in tube light fiitings complete all as specified & directed.
Supply and fixing in repairs electronic driver sutable for 25 watt light fitting etc all as specified and directed site.
Supply and fixing in repairs copper wire 3 core round with sheathed 2.5 sqmm all as specified and directed at site
Supply and fixing in replacemnt of mainswitch single pole with neutral link 32 amps complete with sheet steel enclosure and fixing on board all as specified and and directed at site
Supply and fixing in replacemnt of mainswitch triple pole with neutral link 32 amps complete with sheet steel enclosure and fixing on board all as specified and and directed at site
Supply and fixing in replacemnt main switch single pole with neutral link 63 amps complete with fixing on board etc all as specified and directed at site.
Supply and fixing in replacemnt main switch triple pole with neutral link 63 amps complete with fixing on board etc all as specified and directed at site.
Supply and fixing in replacemnt main switch triple pole with neutral link 125 amps complete with fixing on board etc all as specified and directed at site.
S&F in repairs change over switch 63 amps TPNL on load type with sheet steel enclosure etc all as specified and directed at site
S&F in repairs change over switch 125 amps four pole on load type with sheet steel enclosure etc all as specified and directed at site
S&F in replacement inner and outer plate of minimum 4 modules and up to 8 modules
RAVI TEJ BUILDERS
kiran electrical and hardware centre
mandeka constructions
RAVINDRA ELECTRICAL
SONAL CONSTRUCTION AND ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .