Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC 1630 SECTOR 7 C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.0 L+₹1.5 L (6.75%)Rejected-Finance | L2 | Rejected-Finance higher rate quoted by bidder | |
| 3 | L3₹26.1 L+₹4.6 L (21.1%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance higher rate quoted by bidder | |
| 4 | L4₹34.2 L+₹12.7 L (58.7%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance higher rate quoted by bidder | |
| 5 | L5₹35.3 L+₹13.7 L (63.6%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L5 | Rejected-Finance higher rate quoted by bidder |
Tender Value
₹26.4 L
EMD Value
₹52,900
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JAISALMER
HQ CWE AF JAISALMER
PROVN OF 33 KVA INDEPENDENT OH LINE FROM RAJASTHAN STATE ELECTRICITY BOARD AT AF STN PHALODI
2022_MES_520082_4
80180/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF PHALODI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF PHALODI
₹52,900
Yes
26 Aug 2022
4 Jul 2022
29 Jul 2022
4 Jul 2022
27 Jul 2022
11 Jul 2022
60 days
Amount
(d) Switching (DRM Module) : TSM should not be solid state relay, it should be back to back SCRs housed in a enclosure, comprising of schnubber circuit, firing card, temp. sensor with inbuilt co-axial flow fan as a complete module for each bank, fast electrically controlled, self observing thyristors switch for capacitive load and it should be capable to switch capacitors within few milli second (20 m sec) as often as required, inbuilt co-axial flow fan,should have PIV value 2200 V, 12 V, firing card for each module, containing indication of power ON, SCR-1,SCR-2 -ON, Over Temp indication, fan On indication. (e) IR Module section : 1x11.5 KVAR , 1x23 KVAR, 3x92 KVAR, protection thru HRC fuses,should have ON OFF indication , manual switching through Push button.
(f) Enclosure : The panel shall be OEM/ OEM Licence Partner Made, indoor type, free standing, and floor mounting with IP42 degree of protection as per IEC-61921 specification. It shall be completely made of 2mm thick CRCA sheet steel. The enclosure shall have sturdy support structure with angle supports as necessary and shall be finished with powder coating in the approved colour shade/s. The thickness of powder coating should be minimum 60-80 microns. Suitable provisions shall be made in the panel for proper heat dissipation. Air aspiration louvers for heat dissipation shall be provided as a necessary. The front portion shall house the switchgear and the rear portion shall house IR Modules .The enclosure is to be suitable sized to accommodate all the components, providing necessary air clearance between live and non-live parts, providing necessary working clearance. powder coated colour Seimens Gray 7035, having Aluminium busbar, Bottom/Top cable entry, earthing Busbar in entire panel. (g) AXIAL FLOW FAN - 03 nos of EBM- Nadi make 9" hispeed Axial flow fan with thermostate for proper ventilation. Note:- (i) THD-I should remain under specified limits as per IEEE-519 norms. (ii) Power factor is to be maintained above 0.95 at all times after insttalation of system for specified load.
Supply, lay, joint, fix, test and commission PVC copper conductor armoured control cable size 4 core x 10 Sq mm suitable got system upto 1100V 50Hz AC/DC supply from 33 KV PT to Automatic IR Switch Panel complete all as specified and directed.
Supply, lay, joint, fix, test and commission PVC copper conductor armoured control cable size 6 core x 10 sq mm suitable got system upto1100V 50Hz AC/DC supply from 33 KV CT to Automatic IR Switch Panel complete all as specified and directed.
Excavating in trenches in soft/loose soil, n.exc 1.5m wide and n.exc 1.5m in depth for foundation for laying of cable/ pipe and like including getting out complete all as specified and directed.
Excavating in trenches in hard soil, n.exc 1.5m wide and n.exc 1.5m in depth for foundation for laying of cable/ pipe and like including getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m away and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for dry tibba sand laid in trenches sand cushioning to under ground cable (8cm thickness of sand before laying of cable and 15cm thickness of sand after laying of cable), spreading, levelling hand punning complete all as specified and directed. Note- 18cm thickness will be measured for payment purpose.
Supply and lay un-reinforced precast concrete cable covers class HV, type 1, flat of size 300 x 180 x 40 mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
Supply and lay for un-reinforced precast cement concrete cable cover, Class LV, Type-I, flat, size 250 mm x 150mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
Supply, lay, joint, fix, test and commission; cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor,11000 Volts grade, of size 3 core 95 sq mm complete all as specified and as directed
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for in door termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 Sq mm HT Cable XLPE, armoured, aluminium conductor cable complete all as specified and directed
Supply, lay, joint, fix, test and commission of LT underground cable 1100 Volts grade XLPE insulated screened PVC bedded, armoured with sttel strip electric power cable,heavy duty with multi stranded aluminium conductor laid in trenches duct, fixed on poles/walls with proper size saddle and clamp laid under road/path/drain/culvert or encased in GI pipe of size 300 sqmm 3.5 core complete all as specified and directed
S&F 80mm bore steel tubes, light grade galvanised with all fittings laid in trenches or fixed with pole/wall/under road crossing for protection of cable/earthing strip of size complete all a specified and directed
M&L for Earthing complete with galvanised iron earth electrode 60cm x60cm x6.0 mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connecting to the galvanised iron earth strip of size 32x6 mm, by means of nuts, bolts, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point including pron of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4kg/sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance exceeding 50m, complete all as specified in electrical plate No. 3 of SSR Part-1 and connection to earth test point including testing on completion as directed. Note : The cost of 7.5m long galvanised iron earth strip 32x6mm size and protection pipe of 40mm bore GI medium grade is deemed to be included in quoted unit rate.
M/S VIDIT ENTERPRISES
M/s SCHOLASTIC ENTERPRISES
SANJOLI CONSTRUCTION COMPANY
Rasam Engg Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .