Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹32.9 L+₹6,200 (0.19%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹33.0 L+₹17,320 (0.53%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹33.4 L+₹60,700 (1.85%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹34.9 L+₹2.1 L (6.45%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
29 Sept 2022, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar - Pathardi Road Opp Ahmednagar Fort Ahmednagar - 414 002
Repair/ maint of LT panel copper/GI earthing,lightning arrester,painting of LT/HT poles/two pole structure and repair of main switches/MCCBs and connected accessories work under GE (N) AHmednagar
2022_MES_543445_2
8667 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹60,000
Yes
11 Oct 2022
15 Sept 2022
1 Oct 2022
15 Sept 2022
29 Sept 2022
17 Sept 2022
Amount
Dismantling carefully the existing LT overhead line ACSR of any size from its position by necessary disconnecting of conductor and removing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of unserviceable insulator of any type complete from its position and removing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of existing LT poles carefully of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata, demolition of concrete, disconnecting of conductor etc complete all as specified and directed by Engineer-in-Charge
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm all as specified and as directed. (loop type insulator, stay clamps etc complete all as specified and directed by Engineer-in-Charge Note : excavation and concrete shall be measured and paid separately
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc complete all as specified and directed by Engineer-in-Charge Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor will take care to avoid damage to existing lines/structures if Any breakdown of line caused during punning shall be made good without any extra cost. (ii) Prunning of tree will be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
S&F LT cable route indicator of Cast iron not less than 100 mm dia fixed through welding angle iron supoort of size 25 mm x 25mmx5mm thick ,600mm long including two coats of synthetic enamel paint(yellow in colour) over a coat of red oxide primer planted in a PCC foundation (PCC 1:3:6 using graded stone aggregate), The whole assembly of PCC iron will be planted in ground upto 30 cm etc complete all as specified and directed by Engineer-in-Charge. Note : Rate of PCC foundation is included in quated rate
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of length 2 m etc complete all as specified and directed by Engineer-in-Charge (Excavation and earth work, foundation concrete and PCC coping shall be measured and paid separately)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers etc welding bending cold or hot, drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator bolts, washers and nuts, 100mm height and 115mm dia including two nos of galvanised steel strap of size 31x5mm fitted with 14mm dia bolts and nuts etc complete all as specified and directed by Engineer-in-Charge
Labour for restringing of LT over head line consisting of 4/5/6 conductors retrive from ser item no-01 by dismantling taking down,unserviceable , damged ACSR conductor, repairing wherever required including cutting, re-joining and restringing in, with proper sag, binding to insulator with and including aluminium binding wire etc complete all as specified and directed by Engineer-in-Charge Note : (i) Only good and serviceable conductors are used, unserviceable conductors will be credited to contractor under schedule of credit. (ii) Rate of Transporting of conductor from one site to another site is included this rate.
Supply, fixing and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size etc complete all as specified and directed by Engineer-in-Charge (Note :- (a)jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumpers materials & tree branch cutting to make a safe distance from over head line.)
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil etc complete all as specified and directed by Engineer-in-Charge
All as per ser item No 14 (here-in-before) but hard/ dense soil
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil etc complete all as specified and directed by Engineer-in-Charge
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply & lay HDPE pipe 63 mm bore for laying of LT cables etc complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply & lay HDPE pipe 75mm bore for laying of LT cables etc complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply & lay HDPE pipe 110 mm bore for laying of LT cables etc complete all as specified and directed by Engineer-in-Charge
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-
(a) 16 sqmm 4 core
(b) 35 Sqmm 31/2 core
(c) 50 Sqmm 31/2 core
(d) 70 Sqmm 31/2 core
(e) 95 Sqmm 31/2 core
(f) 120 Sqmm 31/2 core
(g) 150 Sqmm 31/2 core
(h) 185 Sqmm 31/2 core
(j) 240 Sqmm 31/2 core
M/L for GI pipe light grade 40 mm dia Tubes, with all fitting and fixed complete to walls and ceilings or laid in floors complete for protection of cables etc complete all as specified and directed by Engineer-in-Charge
All as per item No 31 (here-in-before) but 50mm dia tubes.
All as per Item No 31 (here-in-before) but 80 mm dia tubes
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling mass concrete etc complete all as specified and directed by Engineer-in-Charge. Note : Rate of mass concrete is included in quated rate.
M & L for cleaning /cutting of grass using grass cutter machine around transformer/ two pole structure/four pole structure and make clear area of 8 X 8 mtr around it etc complete all as specified and directed by Engineer-in-Charge
Demolation of u/s cement concrete in coppings etc complete all as specified and directed by Engineer-in-Charge
M&L cement concrete (1:3:6 ) type C2 using graded stone aggregate as in Copping of pole including necessary form work etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC(1:4:8) type D-2 using 40mm grade stone aggregates as foundation of pole and similar work etc complete all as specified and directed by Engineer-in-Charge
M & L for repair of LT Panel board of any size with replacing the damagable angle iron frame, unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointig cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing thhe panel door by using hinges and repairing the lock system, welding etc painting the LT Panel wit one coat of primer & two coat of synthetic enamel paint as approved or etc complete all as specified and directed by Engineer-in-ChargeNote:(i) MCCB,MCB,Switch fuse unit and change over switch measured and paid separately. (ii) Labour for MCCB, MCB, Switch fuse unit and change over switch measured and paid separately. (iii) Rate of new Busbar, lugs,CRC Solution,nut,bolt, painting etc and washers are deemed to be included in quoted rates.
Supply and fixing in replacement of MCB TPN 63 Amps with breaking cap 16 KA and connecting etc complete all as specified and directed by Engineer-in-Charge .
All as per item No 40 (here-in-before) but 40 Amps
Supply and fixing in replacement of MCB DP, 40 Amps with 10 KA breaking / rupturing capacity including neccssary connection etc complete all as specified and directed by Engineer-in-Charge
All as per item No 42 (here-in-before) but 20 Amps
Supply and fix in replacement MCB, SP, 6 to 32 Amps 10 KA breaking / rupturing capacity capacity including necessary connection with suitable size of copper cable etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in for replacement rewirable switch fuse unit,of sheet metal , triple pole and neutral, 415 Volts grade, 32 Amps capcity including neccssary connection with suitable size of copper cable etc complete all as specified and directed by Engineer-in-Charge
All as Per item No 45 (here-in-before) but 63 Amps capcity .
All as Per item No 45 (here-in-before) but 100 Amps capcity .
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA , Thermal and magnetic adjustable (Ics=100%Icu) 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting etc complete all as specified and directed by Engineer-in-Charge
All as per Sl item No 48 (here-in-before) but 200 Amps 25 KA breaking capacity.
All as per Sl item No 48 (here-in-before) but 160 Amps 25 KA breaking capacity.
All as per Sl item No 48 (here-in-before) but 100 Amps 25 KA breaking capacity.
All as per Sl item No 48 (here-in-before) but 63 Amps 25 KA breaking capacity.
Supply and fix in repairs/replacement of GI continous earth wire 4mm dia on cross arms of poles for guarding including binding and dismentling of old broken guarding etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type on load type, triple pole and neutral, 63 Amps, 415 V, 50 Hz front handle operated, including connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
All as per Item No 54 (here-in-before) but off load type and side handle operated,Conforms IS/IEC 60947 including connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
All per item No 54 (here-in-before) but , off load type, 100 Amps, front handle operated,
All as per item No 54 (here-in-before) but off load type, 125A side handle operated,
All as per item No 54 (here-in-before) but off load type, 200 A side handle operated,
M & L for replacement of existing Amp meter (0-300Amp) along with CTs from existing LT Panel of any size etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of existing Volt meter 0 to 600 volt , digital type from existing LT Panel of any size, etc complete all as specified and directed by Engineer-in-Charge
Material and labour for spray painting the LT Steel tubular pole 9 mtr long with two coats of synthetic enamel paint including prepartion of surfaces, Scraping the old paint and writing pole No in Black letter under yellow circle etc complete all as specified and directed by Engineer-in-Charge
Material and labour for spray painting incuding vehicale and ladder for LT Steel tubular pole(swan neck type) 9 mtr long with two coats of synthetic enamel paint including for prepartion of surfaces, Scraping the old paint and writing pole No in Black letter under yellow circle etc complete all as specified and directed by Engineer-in-Charge
M&L Heat shrinkable straight through joint, with including jointing materials and necessary earth work suitable for 1100 Volts , XLPE LT cable of size 16-25 sq.mm , 3.5/4 core, including fixing, jointing and testing etc complete all as specified and directed by Engineer-in-Charge
M&L Heat shrinkable straight through joint, with including jointing materials and necessary earth work suitable for 1100 Volts , XLPE LT cable of size 35-95 sq.mm , 3.5/4 core, including fixing, jointing and testing etc complete all as specified and directed by Engineer-in-Charge
M & L for Heat shrink joint (end joint) indoor/outdoor LT 1100 volts grade 25-70 sqmm, 4/3.5 core etc complete all as specified and directed by Engineer-in-Charge
M & L for Heat shrink joint (end joint) indoor/outdoor LT 1100 volts grade 95-240 sqmm, 4/3.5 core etc complete all as specified and directed by Engineer-in-Charge
M&L Heat shrinkable straight through joint, with including jointing materials and necessary earth work suitable for 1100 Volts , XLPE LT cable of size 120-240 sq.mm , 3.5/4 core, including fixing, jointing and testing etc complete all as specified and directed by Engineer-in-Charge
M & L for aluminium cable lugs of size upto 50 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed. (Note-To be measured only, fixed at places other than with heat shrink joints) etc complete all as specified and directed by Engineer-in-Charge Make - Dowells or equivalent as approved by GE.
M & L for aluminium cable lugs of size upto 70,95,120,150,185, 240,300 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point etc complete all as specified and directed by Engineer-in-Charge. Make - Dowells or equivalent as approved by GE
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion etc complete all as specified and directed by Engineer-in-Charge Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 600 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc with RYB indicater,internal wiring with suitable size of copper wire,panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts etc complete all as specified and directed by Engineer-in-Charge.(Stn HQ,ASC)
Incoming : - (i) MCCB 400 Amp thermal and magnetic adjustable type with , 4 Pole,36KA - 01 No. (Ics=100%Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable (viii) KWH meter CT operated as per suitable capacity of LT Panel Outgoing ways :- MCCB 200 Amps Thermal and magnetic adjudtable type ,4 pole,25 KA-04 Nos (Ics=100%Icu) Notes:- 1. The Panel Should be approved by CPRI. 2. The rates Quoted shall include for earth work,Plinth protection around the panel apprx 75cm and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0.40 M from GL to the bottom of panel board. 3. All MCCBs should be handle operated and connected through HRC Fuse 4.Make of MCCBs 5.All incoming power MCCBs and outgoing MCCBs connected through busbar and control wiring connected through copper cable
S&F in replacement of drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one etc complete all as specified and directed by Engineer-in-Charge
Repair / Overhauling of air break switch/GOD by replacing stationary and moving contacts using jelly, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and etc complete all as specified and directed by Engineer-in-Charge
Supply & fix LT line seperator 3/4 lines made of high quantity PVC material to provide 300 mm distance between phase to phase and neutal or as per sit reuirement etc complete all as specified and directed by Engineer-in-Charge Make: Supreme & Co Pvt Ltd Sanjay casting and Engineers, Mahalaxmi cable & Conductor or equivalent as approved by GE
M&L Outdoor type bus bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos aluminium bus bar, of capacity 400 Amps fabricated in factory having modern fabrication facility duly powder coated painting, dust and vermin proof, degree of protection not less than IP-55, the panel shall be made out of 3.00mm thick CRCA mild steel sheet, front door (01 layer) and rear door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level including installation, commissioning, testing and necessary PCC work Make: Supreme & Co Pvt Ltd Sanjay casting and Engineers, Mahalaxmi cable & Conductor.
M & L for LED post top lantern 20 watt in repair made of pure polyster UV resistant powder coated die cast aluminium housing, integral, make wipro or equivalent. Make : Wipro Cat No. LP07-251-XXX-57-CL or its equivalent makes mentioned in list of makes in Appendix `C'.
Attending day to day complaints of external electric supply system under AOR of AGE E/M-II, finding big fault in over head line LT/HT and rectify the fault using man power ,vehicale and eletrician etc complete all as specified and directed by Engineer-in-Charge NOTE:- (i) The fault locating equipments will be brought to site within the 02 hours of instruction from Engr-in-Charge. (ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2400 hrs and has to be rectified within 2 hours after notification, failing which Rs 1500/- per day per complaint will be recovered from the dues of the contractor. (iii) Quoted rates are deemed to be included necessary earth work for opening cable,vehical,man power.
Supply only Insulation tape 6 mtr in length in (R ,Y ,B in colour) dimension(0 .125mm thick x1.80 cm width x6 mtr length) etc complete all as specified and directed by Engineer-in-Charge. Make : Anchor
M & L for PVC insulated, PVC sheathed twin flat core 1100 volts grade, 10 sqmm aluminium stranded conductor fron OH conductor or from junction box to street/security/post top luminaries etc complete all as specified and directed by Engineer-in-Charge
M & L for PVC insulated, PVC sheathed twin flat core 1100 volts grade, 4 sqmm aluminium stranded conductor fron OH conductor or from junction box to street/security/post top luminaries etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair of jumper with PVC shealeded aluminium single core power cable of size 70 Sqmm,11KV, with heat shrinkle sleeve at both ends confirming to IS 8098 including taking down unsv cable etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of synthetic insulating rubber mat of size 2m x1m x 12 mm etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of Galvanised iron strip 32 x6mm buried in ground etc complete all as specified and directed by Engineer-in-Charge
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil etc complete all as specified and directed by Engineer-in-Charge
M & L for cement concrete type C2 (1:3:6) using 40 mm graded stone aggregate in foundations, filling as mass concrete etc complete all as specified and directed by Engineer-in-Charge
Supply only chain link MS galvanized fencing of any size or type etc complete all as specified and directed by Engineer-in-Charge
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire etc complete all as specified and directed by Engineer-in-Charge
S & F mild steel bolt screwed one end with hexagonal or square nuts & washers the other end enlarged not exc 15cm long dia of neck 12mm etc complete all as specified and directed by Engineer-in-Charge
M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and directed by Engineer-in-Charge
S & F mild steel flat iron, round or square bars, in available lengths, Fe-290, Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide etc complete all as specified and directed by Engineer-in-Charge
S & F 10mm dia round bars etc complete all as specified and directed by Engineer-in-Charge
An amount of Rs 53,700.00 shall be deducted from BOQ on account of schedule of credit
vedant engineering enterprises
metro electrical services
Shri Sai Enterprises
Ms. S.K. ASSOCIATES
Maruti Abhiyantriki
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .