| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC TULSI ASTHA FLAT NO 1 PLOT NO 54 SECTOR 12 VASHI NAVI MUMBAI THANE 400 703 | THANE | MAHARASHTRA | 400703 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹12.9 L+₹79,950 (6.61%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹14.6 L+₹2.5 L (21.0%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹15.7 L+₹3.6 L (30.0%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹16.1 L+₹4.0 L (33.3%)Rejected-AOC 1ST FLOOR SIDDHI PUJA BUSINESS SQUARE SONY PAITHANI CHOWK NASHIK MAHARASHTRA INDIA PIN 422 002 | NASHIK | MAHARASHTRA | 422002 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-88
PERIODICAL SERVICES TO VARIOUS BUILDINGS AT NAD (TROMBAY) UNDER GE (NW) MANKHURD
2022_MES_567065_1
8196/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) MANKHURD
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE (NW) MANKHURD
₹50,000
Yes
3 Mar 2023
3 Dec 2022
24 Dec 2022
3 Dec 2022
22 Dec 2022
9 Dec 2022
Amount
Taking down cement or cement lime plaster of any description on brick or stone walls, including raking out joints, hacking for keys, scrubbing down with water, etc. including all necessary scaffolding as required and taking off rubbish outside Mud land, etc. complete all as specified and as directed.
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces using CM 1:6, finished the surface even and smooth with sagol finish including all necessary scaffolding as required all as specified and as directed.
M&L for 20mm thick polymer modified ready mix cement based plaster in two layers (12 + 8 mm) on the wall surfaces, top layer of 8 mm mixed with liquid water proofing compound in the proportion as per manufacturer’s instructions and including finishing the surfaces of the top layer even and smooth, including scaffolding as required complete all as specified and directed, Make : Easy plast from M/s wall plast or chemplast or Readiplast from ultratech. Notes : (i) The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with the ready mix plaster and nothing extra shall be payable on this account. (ii) WPC shall be paid for separately.
M & L Rendering 5 mm thick on fair faces of concrete surfaces using CM 1:3, finished the surface even and smooth in ceiling including all necessary scaffolding as required all as specified and as directed.
Supply only integral water proofing compound
M&L for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. by skilled labour including all necessary scaffolding as required complete all as directed.
M&L for waterproof cement based putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface including all necessary scaffolding as required.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer including all necessary scaffolding as required.
M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. Note for Item No 1 to 10 above (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b.) The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected including all necessary scaffolding as required.
Chipping, removing carefully loose/damaged concrete incl plastering (total thickness up to 60mm ) from RCC surfaces of columns, beams,Chajas, soffits of slabs etc by low impact Hammer/Breaker without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land including all necessary scaffolding as required, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, including all necessary scaffolding as required complete all as specified and directed. [Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.]
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces including all necessary scaffolding as requiredcomplete all as specified and directed. Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.
M&L for providing TMT bars any dia in various structural RCC elements like columns, beams, Slabs etc. including cutting, bending, fixing of bars with welding/ tying as required at site with & including binding wires etc. and all relevant works like anchoring of the bars in the existing RCC Members, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application including all necessary scaffolding as required complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit, up to 20mm thickness while the bonding agent is still tacking, including leveling, profiling etc,including all necessary scaffolding as required complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit while the bonding agent is still tacking, exceeding 20mm thickness and not exceeding 40mm thickness in two layers, each layer not exceeding 20mm, including leveling, profiling etc, including all necessary scaffolding as required complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thickness) with prebatched, prepacked, single component ready to use micro concrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, leveling, finishing, curing etc as per manufacturer's specifications and all other relevant works, including all necessary scaffolding as requiredcomplete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for preparation of newly plastered surfaces of ceilings and applying three coats of white wash including all necessary scaffolding as required complete all as specified.
M & L for preparing new decorated surfaces of wall (plasterered or unplastered or previously white washed) & applying two coat of oil bound distemper with 3mm thick wall care putty including all necessary scaffolding as required complete all as specified.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces including all necessary scaffolding as required complete all as specified and directed.
Material and labour for preparation of old treated surfaces of any description and at any position and applying one coat acrylic exterior antifungal paint including all necessary scaffolding as required complete all as specified and as directed
M&L for leakage / seepage proof coating consisting of preparing the new surfaces of existing exterior walls, parapet walls, chajjas, soffit of beams, columns etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Notes. The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
Material and labour for washing, rubbing down and stopping of old painted surfaces , preparation of surfaces of any description and at any position such as external surfaces of walls, chajjas, roof projections, soffits of chajjas etc, applying one coat of putty (minimum thickness 1 mm) and applying two coats of 100% antifungal acrylic exterior emulsion paint over one coat of acrylic primer by mechanical sprayer as approved by manufacturer of paint, including necessary scaffolding complete all as specified and directed. Note : (i) The aforesaid item shall be got executed by the contractor from the authorised applicator of manufacturer and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE. (ii) Putty, Primer and Paint shall be used from the same manufacturer.
M & L Preparation of old plastered or un-plastered surface of wall and applying one coat of white wash including all necessary scaffolding as required complete all as specified and as directed
All as per ser Item No 24 above but on ceiling.
M & L for preparing old decorated surfaces of wall complete removal of existing treatment (plasterered or unplastered or previously white washed) & applying two coats of cement base paint over one coat of primer including all necessary scaffolding as required complete all as specified.
M & L for washing rubbing down & stopping of distempered & painted surfaces of walls, preparation of surfaces & applying one coat of oil bound distemper including all necessary scaffolding as required complete all as specified & directed by EIC.
M & L for preparing old decorated surfaces of wall (plasterered or unplastered or previously white washed) & applying two coat of oil bound distemper with 3mm thick wall care putty including all necessary scaffolding as required complete all as specified.
M& L preparation of old painted wooden surface of any description not other wise described , over 10cm width or girth and applying one coat of synthetic enamel paint including all necessary scaffolding as required complete all as specified and as directed.
M& L preparation of old painted steel surface of any description not other wise described , over 10cm width or girth and applying one coat of synthetic enamel paint including all necessary scaffolding as required complete all as specified and as directed.
Writing letters or figures (Block.Roman, Italic or Indian) n exc. 30 cm high complete including all necessary scaffolding as required all as specified and directed.
Removing plant/growth including its roots up to 1.00 metre of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, including all necessary scaffolding as requiredcomplete all as specified and directed.
Parmatma Enterprises
AM ENTERPRISES
Joy builders
M/s Mohd Altaf Hanif Qureshi
Vishal Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .