Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 accepted | |
| 2 | L2₹11.6 L+₹1.6 L (16.1%)Rejected-AOC H NO 3 1 197 P58 MYTINAGAR COLONY LB NAGAR HYDERABAD 500 074 | HYDERABAD | HYDERABAD | TELANGANA | 500074 | L2 | Rejected-AOC Being L2 not accepted | |
| 3 | L3₹12.5 L+₹2.5 L (25.1%)Rejected-AOC | L3 | Rejected-AOC Being L3 not accepted | |
| 4 | L4₹12.7 L+₹2.7 L (27.5%)Rejected-AOC | L4 | Rejected-AOC Being L4 not accepted | |
| 5 | L5₹13.0 L+₹3.1 L (30.9%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L5 | Rejected-AOC Being L5 not accepted |
| Sl No | Description | Qty | Unit | L and S ENTERPRISES L5 | MOHAMMED MUMTAZ ENGINEERING WORKS L1 | GANGARAJU ENTERPRISES L3 | Rallapati siva sai prasad L4 | veerender constructions L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, erecting, testing and commissioning Raising and Lowering type (min 16 Metre height high mast system hot dip galvanised inside and outside) in single dip, suitable for wind velocity as per IS 875 part 3 with only one longitudinal seam weld per section but without circumferential weld including accessories viz head frame, 2 point suspension system with steel wire rope 6mm dia 7/19 gauge, double drum winch, galvanised lantern carriage arrangement suitable for and with 8 nos luminaries symetrically lightning finial, LED aviation obstruction light of 9/10 watt, lighting arrestor spikes, foundation bolts, nuts, anchor plates, templates, trailing cable and integral power tool for raising and lowering operation of high mast with and including following technical specifications :- (a) High Mast System, Height of Mast - min 16 mtr, No. of sections - two material construction - S355 grade as per BS-EN10025, Base dia and top diameter (A/F) - 360mm and 150mm respectively, Plate thickness : Top - 3mm, Bottom - 3mm, Cross section of Mast - 12 side polygon, standard for of galvanisastion - As per BS EN ISO 1461/BS729/IS2629. (b) Size of opening and door at base - 1200mm x 250mm, Diametre of base plate - 520mm, Thickness of base plate - 25mm, Lightning protection finial - GI single spike, Max wind speed - 50 m/s as per IS 875 (Part-III), Number of foundation bolts - 6 Nos, PCD of foundation bolts - 445mm, Type/diameter/length of foundation bolts - TS 600/24 mm dia/850mm long Diametre of carriage ring (mm) - 535mm (ID) minimum Construction - 8 arm welded 2 sections, Load carrying capacity 8 Lumminaire (c) WINCH/POWER TOOL Type/SWL of winch Double Drum / SWL 350 Kg, Method of operation - Integral Motor, Motor Capacity - 1HP Three Phase, No. of Speed - 6 Pole, Single Speed - 128.02 (d) STAINLESS STEEL WIRE ROPE grade/Construction - AISI304.7/19 Construction No. of Ropes - Two continuous Diametre (mm) - 5mm, Braking load capacity (min) - 1450 Kg x 2128.04.
Note : All as per manufacturer recommedations
(e) FEEDER PILLAR Powder coated CRCA steel sheet feeder pillar for outdoor application with 63 amp four pole MCB incomer, Nature switch, 16 amp, 420 volts suitable for automatic switching ON and OFF of the luminaires, 9 Amp two contactors and raise lower push buttons for motor operation, incoming terminals of 50 Sqmm and outgong terminals of 16 Sqmm for power cable and 2.5 Sqmm for motor mounted on suitable foundation (f) FOUNDATION - Construction of suitable shallow foundation with M20 grade concrete for high mast consdering the state soil bearing capacity at site as 10T/Sqm at 2 m depth. (g) TRAILING CABLE - PVC insulated PVC sheathed 1100 volt grade ISI marked multistranded copper conductor cable 6 core 2.5 sqmm. (h) FLOOD LIGHT LUMINAIRE - Eight number LED flood light luminaires having a nominal system lumen output of minimum 15000 lumens at a minimum system efficacy of 100 lumens per watt and total power consumption not more than 150 watt includin driver, it has a rated sytem life time of 50000 burning hours at L70 and should have a color temperature of 6500 K, CRI>80, THD<10% and PF>0.95 complete & surge protection not less than 10 KV. (j) Automatic light control switch with infrared sensor based Nature Switch & voltage monitoring luminance level for Switching ON is < 30 Lux and for Switching OFF > 10 Lux. The Sensor should also have night operation facility of min. 4 hrs to max 12 hrs. VMS should have adjustable Over & Under voltage trip level and protection against Phaseloss, Neutral Loss & mountable enclosure made of Rust Proof, Electric Shock Proof, Terminate proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e sensor & VMS By-Pass option) with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 16-20 Amps each & Circuit Wiring complete all as specified and directed. | 2 | Each | 6,21,000 ₹12,42,000 | 4,50,000 ₹9,00,000 Lowest | 5,57,492 ₹11,14,984 | 5,50,000 ₹11,00,000 | 5,40,000 ₹10,80,000 |
| 2.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. | 175 | RM | 171 ₹29,925 | 270 ₹47,250 | 310 ₹54,250 | 500 ₹87,500 | 162 ₹28,350 Lowest |
| 3.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in hard/dense soil complete all as directed and specified. | 36 | Cum | 216 ₹7,776 Lowest | 360 ₹12,960 | 608 ₹21,888 | 600 ₹21,600 | 405 ₹14,580 |
| 4.00 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed. | 17 | Cum | 63 ₹1,071 Lowest | 63 ₹1,071 Lowest | 176 ₹2,992 | 150 ₹2,550 | 72 ₹1,224 |
| 5.00 | Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed. | 20 | Cum | 63 ₹1,260 Lowest | 90 ₹1,800 | 160 ₹3,200 | 300 ₹6,000 | 207 ₹4,140 |
| 6.00 | Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed.
Note:- Punned thickness will be measured for payment purpose. | 15 | Cum | 900 ₹13,500 Lowest | 1,260 ₹18,900 | 1,760 ₹26,400 | 1,900 ₹28,500 | 999 ₹14,985 |
| 7.00 | M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed. | 1.56 | 1000 Nos | 5,400 ₹8,451 Lowest | 9,000 ₹14,085 | 14,400 ₹22,536 | 15,000 ₹23,475 | 8,100 ₹12,676.5 |
Tender Value
₹15.2 L
EMD Value
₹30,400
Closing Date
2 Jan 2026, 6:00 pmClosed
GE Golconda
GE GOLCONDA LANGER HOUSE ROAD OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
PROVISION OF 2 X HIGH MAST LIGHTS AT TYPE - V OFFICERS COMPLEX AND TYPE-III MD ACCN CIRCLE UNDER GE GOLCONDA
2025_MES_744297_1
8937/E8
Open Tender
Civil Works
Item Rate
90 days
GE GOLCONDA
As per Tender
9 documents required · 9 mandatory
₹500
GE Golconda
₹30,400
Yes
2 Feb 2026
12 Dec 2025
5 Jan 2026
12 Dec 2025
2 Jan 2026
26 Dec 2025
Amount
Supplying, erecting, testing and commissioning Raising and Lowering type (min 16 Metre height high mast system hot dip galvanised inside and outside) in single dip, suitable for wind velocity as per IS 875 part 3 with only one longitudinal seam weld per section but without circumferential weld including accessories viz head frame, 2 point suspension system with steel wire rope 6mm dia 7/19 gauge, double drum winch, galvanised lantern carriage arrangement suitable for and with 8 nos luminaries symetrically lightning finial, LED aviation obstruction light of 9/10 watt, lighting arrestor spikes, foundation bolts, nuts, anchor plates, templates, trailing cable and integral power tool for raising and lowering operation of high mast with and including following technical specifications :- (a) High Mast System, Height of Mast - min 16 mtr, No. of sections - two material construction - S355 grade as per BS-EN10025, Base dia and top diameter (A/F) - 360mm and 150mm respectively, Plate thickness : Top - 3mm, Bottom - 3mm, Cross section of Mast - 12 side polygon, standard for of galvanisastion - As per BS EN ISO 1461/BS729/IS2629. (b) Size of opening and door at base - 1200mm x 250mm, Diametre of base plate - 520mm, Thickness of base plate - 25mm, Lightning protection finial - GI single spike, Max wind speed - 50 m/s as per IS 875 (Part-III), Number of foundation bolts - 6 Nos, PCD of foundation bolts - 445mm, Type/diameter/length of foundation bolts - TS 600/24 mm dia/850mm long Diametre of carriage ring (mm) - 535mm (ID) minimum Construction - 8 arm welded 2 sections, Load carrying capacity 8 Lumminaire (c) WINCH/POWER TOOL Type/SWL of winch Double Drum / SWL 350 Kg, Method of operation - Integral Motor, Motor Capacity - 1HP Three Phase, No. of Speed - 6 Pole, Single Speed - 128.02 (d) STAINLESS STEEL WIRE ROPE grade/Construction - AISI304.7/19 Construction No. of Ropes - Two continuous Diametre (mm) - 5mm, Braking load capacity (min) - 1450 Kg x 2128.04. Note : All as per manufacturer recommedations (e) FEEDER PILLAR Powder coated CRCA steel sheet feeder pillar for outdoor application with 63 amp four pole MCB incomer, Nature switch, 16 amp, 420 volts suitable for automatic switching ON and OFF of the luminaires, 9 Amp two contactors and raise lower push buttons for motor operation, incoming terminals of 50 Sqmm and outgong terminals of 16 Sqmm for power cable and 2.5 Sqmm for motor mounted on suitable foundation (f) FOUNDATION - Construction of suitable shallow foundation with M20 grade concrete for high mast consdering the state soil bearing capacity at site as 10T/Sqm at 2 m depth. (g) TRAILING CABLE - PVC insulated PVC sheathed 1100 volt grade ISI marked multistranded copper conductor cable 6 core 2.5 sqmm. (h) FLOOD LIGHT LUMINAIRE - Eight number LED flood light luminaires having a nominal system lumen output of minimum 15000 lumens at a minimum system efficacy of 100 lumens per watt and total power consumption not more than 150 watt includin driver, it has a rated sytem life time of 50000 burning hours at L70 and should have a color temperature of 6500 K, CRI>80, THD<10% and PF>0.95 complete & surge protection not less than 10 KV. (j) Automatic light control switch with infrared sensor based Nature Switch & voltage monitoring luminance level for Switching ON is < 30 Lux and for Switching OFF > 10 Lux. The Sensor should also have night operation facility of min. 4 hrs to max 12 hrs. VMS should have adjustable Over & Under voltage trip level and protection against Phaseloss, Neutral Loss & mountable enclosure made of Rust Proof, Electric Shock Proof, Terminate proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e sensor & VMS By-Pass option) with 3 nos. Contactors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 16-20 Amps each & Circuit Wiring complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved dry river sand for cable laying /foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as all as specified and directed. Note:- Punned thickness will be measured for payment purpose.
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed.
veerender constructions (BID ID -3514483)
GANGARAJU ENTERPRISES (BID ID -3520016)
Rallapati siva sai prasad (BID ID -3513923)
L and S ENTERPRISES (BID ID -3512443)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8937NIT.pdf
Additional Documents • 0.31 MB
8937Tender.pdf
Tender Documents • 0.80 MB
BOQ_833423.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .