| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹27.5 L+₹10.4 L (61.4%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹30.5 L+₹13.5 L (79.3%)Rejected-Finance 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹31.9 L+₹14.8 L (87.3%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹33.4 L+₹16.4 L (96.5%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT OF LT DISTRIBUTION SYSTEM AND OTHER CONNECTED WORK OF SECTOR A AND ADJACENT AREA UNDER AGE EM II OF GE 865 EWS
2024_MES_647513_1
865/EWS(NIT-34)/2024-25
Open Tender
Civil Works
Item Wise
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹80,000
Yes
24 Jun 2024
22 Mar 2024
18 Apr 2024
22 Mar 2024
11 Apr 2024
5 Apr 2024
Amount
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation etc in Hard and Dence soil & getting out for laying of cable complete all as specified & directed.
All as per item No 1 above but additional 1.5 mtrs or part there of in depth beyond the first 1.5 m complete all as specified & directed.
Returning filling in including spreading leveling watering & well ramming in layers n exc. 25cm Cum thick, complete all as specified & directed.
Removing of surplus excavated soil to a distance n.exe 50 Mtr and depositing where directed at a level n.exe 1.5 mtr above the starting point complete all as specified & directed.
Material and labour for sand in trenches as in cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose complete all as specified and directed.
Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm complete all as specified & directed.
Dismantling of ACSR conductor any size complete all as specified and directed.
Material and labour for ACSR conductor of required size for O/H lines, on poles, including stringing and binding wire, complete all as specified & directed.
Fixing only of ACSR conductor of any size obtained from item No. 7 here-in-above with required sag, including jumparing complete all as specified & directed.
Restringing of old ACSR conductor / earth continuity conductor by unbinding the conductor from the insulators, stringing the conductor to the extent to avoid over sag, binding the conductors to insulators with aluminium binding wire (max five conductor per span of length upto 35m) complete all as specified and directed.
Dismantling and taking out damaged / rusted GI earth wire / cradle guard complete all as specified and directed.
Supply and fixing / stringing, galvanized steel wire 4mm dia for earth conductor, on poles including binding wire etc complete all as specified and directed.
Material and labour for Cradle guard by bending the 4mm GI wire in the required shape hexagonal or rectangular and fixing it on OH Line at site by incorporating the required number of reel insulators complete all as specified & directed.
Dismantling of insulator complete of any size and type from exisiting site complete all as specified & directed.
M&L for Shackle Type polymer insulator including galvanised mild steel straps, washers insulator bolts, washers and nuts of height 100 mm, max dia 115 mm,section of straps 31x5 mm,dia of bolts 14 mm complete all as specified & directed.
M&L for Pin insulator polymer white, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified & directed.
M&L for loop Polymor insulator white small size with overall dimensions 65 x 90mm, clearance of hole 16mm for stay complete all as specified & directed.
Dismantling of stay assembly complete of any size and type from exisiting site complete all as specified & directed.
M&L for stay assembly complete with stay plate bow, stay rod of dia 16mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR part - I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) complete all as specified & directed.
M&L for replacement of LT PVC Separator and Spacer Sparell with all accessories complete all as specified and directed by Engr-In-Charge.
M&L for Painting to exposed surfaces of LT Steel tubular pole with one coat of synthetic enamel paint of complete pole and up to 1 mtr height from ground level with 3 strip of yellow colour synthetic enamel paint and two strip of black synthetic paint including preparation of old painted surface, complete all as specified and directed by engr-in charge.
Disconnecting and Taking out old LT armored XLPE cables from trenches of any size/core/any voltage grade from trenches/poles /pipes, for replacement complete all as specified & directed.
Supply and lay PVC insulated, heavy duty, LT XLPE galvanised steel strip armoured electric power cable of size 25 Sqmm x 4 core with stranded aluminium conductor 1100 Volts grade, jointed with cable glands, lugs etc., laid in trenches/drawn through pipe, with and including taking down old unserviceable cable, complete all as specified and directed.
All as per item srl No 23 above but of size 35 sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item srl No 23 above but of size 50 sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item No 23 above But size of 95 Sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item No 26 above But size of 120 Sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item No 23 above But size of 150 Sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item srl No 23 above but of size 185 sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item No 26 above But size of 300 Sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item No 26 above But size of 400 Sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
All as per item No 23 above But size of 630 Sqmm 3.5 core nominal cross section complete, 1100 volts. complete all as specified & directed.
Taking down old unserviceable GI pipe light grade any size coplete all as specified and directed
S&F GI tubing 40mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as specified & directed.
S&F GI tubing 50mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as specified & directed.
S&F GI tubing 80mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc, complete all as specified & directed.
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 32X6 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed Note- (i) earth resistance not more than 1.0 OHMS.Writing of details on the surface of the pit with paint. (ii) In case earth resistance more than 1.0 ohms, the contractor wiil re earthing at no extra cost. (iii) On testing, if the earth resistance less than specified is not obtained, earthing will be regenerated at NO EXTRA COST till the desired earth resistance is obtained.
All as per itme no:37 above but 4 mm GI wire omplete all as specified & as directed.
Dismantling steel poles/struts, any size complete all as specified & as directed.
Supply, erecting and fixing in true vertical position Steel tubular swaged poles (9.0 metres long) complete with cast iron base plate, finial taper plug,bolts,nuts & screws as specified type 410 SP-31, complete all as specified. Note : - Earth work & PCC work will be measured & paid seprately under relavent item.
Material & labour for PCC 1:4:8, type D2 ( using 40 mm graded stone aggregate) as in base for foundation of the pole, complete all as specified & directed.
Material & labour for Providing PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in mass filling complete all as specified & directed.
Material & labour for providing PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) for plinth coping complete all as specified & directed.
Supply and fixing in replacement On load changeover switch 1000 Amps, 4 pole in sheet metal enclosure, side /front handle operated, complete all as specified & directed.
Supply and fixing in replacement On load changeover switch 630 Amps, 4 pole in sheet metal enclosure, side /front handle operated, complete all as secified and directed
Supply and fixing in replacement On load changeover switch 400 Amps, 4 pole in sheet metal enclosure, side /front handle operated, complete all as secified and directed
Supply and fixing in replacement On load changeover switch 200 Amps, 4 pole in sheet metal enclosure, side /front handle operated, 30 complete all as secified and directed
Supply and fixing in replacement Off load changeover switch 630 Amps, 4 pole in sheet metal enclosure, side /front handle operated, complete all as secified and directed
Supply and fixing in replacement Off load changeover switch 400 Amps, 4 pole in sheet metal enclosure, side /front handle operated, complete all as secified and directed
Supply and fixing in replacement Off load changeover switch 200 Amps, 4 pole in sheet metal enclosure, side /front handle operated, 0 complete all as secified and directed
S & F in replacement ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1250 Amps 50 KA complete incl taking down old one, complete all as specified and directed by Engr-In-Charge.
S & F in replacement ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 1000 Amps 50 KA incl taking down old one complete all as specified and directed by Engr-In-Charge.
S & F in replacement MCCBs 415 Volt 4 pole Adjustable thermal & adjustable Magnetic Setting with breaking capacity 36KA 160 Amps complete all as specified and directed by Engr-In-Charge.
S & F in replacement MCCBs 415 Volt 4 pole Adjustable thermal & adjustable Magnetic Setting with breaking capacity 36KA 200 Amps complete all as specified and directed by Engr-In-Charge.
S & F in replacement MCCBs 415 Volt 4 pole Adjustable thermal & adjustable Magnetic Setting with breaking capacity 36KA 250 Amps complete all as specified and directed by Engr-In-Charge.
S & F in replacement MCCBs 415 Volt 4 pole Adjustable thermal & adjustable Magnetic Setting with breaking capacity 36KA 400 Amps complete all as specified and directed by Engr-In-Charge.
S & F in replacement MCCBs 415 Volt 4 pole Adjustable thermal & adjustable Magnetic Setting with breaking capacity 50KA 630 Amps complete all as specified and directed by Engr-In-Charge.
Dismantling UNSV air break gang operated and Supply, installation connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on Polymer insulators 15 Nos and steel frame with operating mechanism with 20 mm dia GI Pipe (Medium Grade) Rod worked from ground level, drop out fuse, for current rating upto 200 amps and working voltage 11000 volts all as required at site or directed by Engr-in-charge.
Supply & laying or fixing 1100 volts grade duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall PVC sheathed solid conductor in service connections 4 Sqmm twin core flat/circular cable complete all as specified and directed.
All as per item No 59.00 above but 6 Sqmm 2 core.
All as per item No 59.00 above but 10 Sqmm 2 core.
S & F earth continuity conductor or main earthing lead buried in ground or fixed on installations/poles for earthing etc of size 32 mm x 6 mm galvanised iron strip, including suitable clamps for fixing complete all as specified.
S&F danger notice plate for LT 20x15cm size made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red, colour and fixed with suitable MS clamps, bolts and nuts. complete all as specified & directed.
Supply and fixing cable route indicator, made of MS sheet of size 200 mm x 150 mm x 3 mm thick, spot welded with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2 ( using 40mm graded crushed stone aggregate) block 30cm x 30cm x 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint and showing size of cable HT /LT complete all as directed & specified.
Cutting the existing PCC/ Road for passing of UG Cable in road crossing and making good the disturbed surface of road to its original specification complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 25 sqmm cable complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 50 sqmm cable complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 70 sqmm cable complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 95 sqmm cable complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 150 sqmm cable complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 240 sqmm cable complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 400 sqmm cable
S & F in replacement of aluminium thimble suitable for size 500 sqmm cable complete all as specified & directed.
S & F in replacement of aluminium thimble suitable for size 625/630 sqmm cable complete all as specified & directed.
S & F in replacement aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified & directed.
S & F in replacement air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified & directed.
S & F in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified & directed.
SUMEET TRADING CORPORATION
Sona Enterprises
Horizon Construction Company
R B TRADERS
RAVI KUMAR
RND ENGINEERS & CONTRACTORS
M.S Sharma Enterprises
EESSI
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .