| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | ₹23.8 L | L1 | Accepted-AOC Accepted being lowest on 23 Sep 2020 |
| 2 | L2₹26.7 L+₹2.9 L (12.1%)Rejected-Finance | ₹26.7 L+₹2.9 L (12.1%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹26.8 L+₹3.0 L (12.8%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹26.8 L+₹3.0 L (12.8%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹27.1 L+₹3.3 L (13.7%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | ₹27.1 L+₹3.3 L (13.7%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹27.8 L+₹4.0 L (17.0%)Rejected-Finance A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | ₹27.8 L+₹4.0 L (17.0%) | L5 | Rejected-Finance Rejected |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
3 Sept 2020, 6:00 pmClosed
GE Faridkot
GE Faridkot-151203 01639-264982
Special repairs to ceiling fan against BER, Provn of geyesers, exhaust fan and certain revenue / minor works under AGE E/M at Faridkot Mil Stn
2020_MES_363781_2
GE FRD-46/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faridkot Mil Stn
Class D Category b i
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹69,000
Yes
14 Oct 2020
12 Aug 2020
5 Sept 2020
12 Aug 2020
3 Sept 2020
19 Aug 2020
Amount
Supply, installation, commissioning and testing water storage heater (geyser) vertical type of 25 ltr capacity, ultrathick stainless steel superior 304 Gde PUF insulation thermostate, thermal cut off, 1PX4 multifunctional safety valve technology, feroglas dry powder coating finish, suitable for to operate / function on AC 220 V, single phase having heating element of 2 KW capacity and high thermal cut-out, energy saving BEE 3 star rating or above including fixed along walls including grouting fastening & fixing (04 Nos) 16mm dia 150mm long GI bolts & nuts, washers and connecting up inlet/ outlet with cold water PVC connection pipes and electric connections cable cord min 1.50m length with copper conductor cable 3 core and 3 pin plug 15/16 Amp, including making good the disturbed surfaces matching with existing complete all as specified and directed by the Engr-in-charge. Make :- Havells, Bajaj, V Gaurd, Crompton Greaves, Racold, Jaquar & Co Pvt Ltd Note : PVC connection will be measured & paid separately.
S & F exhaust fan 300mm sweep, 1380 RPM (Trans air 3 blade) 70 watt, with louver shutter suitable for operation on 220/230 volts, single phase , AC and complete all as specified & directed by Engr-in-charge. Make : Crompton, Khaitan, Bajaj, Almonard, GEC, Havells, Surya Roshni Ltd
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 2.5 Sqmm single core drawing through concealed conduit terminated with steel pressed sunken terminal boxes and 2.5 sqmm PVC stranded copper conductor insulated unseathed stranded wire with different colour (red/blue/yellow for line, black for neutral and green for earth point dolly for earth plug & socket with MCB and making good surface after completion of work complete all as specified and directed by Engineer in Charge.
S&F Plug metal clad SP & N with a 2 pin earth plug and socket with MCB SP & N 20 Amps suitable for working on 230 volts AC complete all as specified & directed by Engineer-in-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core drawn in including concealed PVC conduit 20mm dia with all accessories such as bend reducers /MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded wire with different colour (red / blue/ yellow for line, black for neutral and green for earth point dolly for switch socket combination 5 Amp 5 Pin socket outlet one light point/fan point/call bell point, and indipendent board and making good surface after completion of work complete all as specified and directed by Engineer in Charge.
S&F switch piano flush type single pole one way 5 /6 Amp,230 Volt, AC supply complete all as specified and directed by Engineer in Charge.
S&F Ceiling rose, three terminals PVC/ polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed by Engineer in Charge.
M & L for cutting opening through wall for window and other opening or enlarging existing opening etc. cutting out diffective masonary for under pinning in any mortar for fixing / mounting exhaust fan fixed by bolts , nuts and washers grouted in wall in PCC (1: 2 : 4) and making good surface after completion of work complete all as specified & directed by Engr-in-charge.
Supply and laying mild steel water tubing medium grade galvanised of size 15mm bore with all fittings and laid in trenches under floor/ road or on wall complete all as specified and directed by Engineer-in-charge
S&F stop valves cast copper alloy fancy type, chormium plated with long shank and cup (concealed type ), with crutch or butterfly handle screwed for iron pipe or brass ferrule for 15mm bore pipe fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing PVC connections 15mm size with PTMT nuts of length 300mm suitable for (cold pipe) application complete all as specified & directed by Engineer-in-charge.
Supply & fixing PVC connections 15mm size with PTMT nuts of length 300mm suitable for (hot pipe) application complete all as specified & directed by Engineer-in-charge.
S&F 15mm bore bib tap, cast copper alloy, chromium plated with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 cross sectional area 16 Sqmm 4 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
S&F sub-main wiring with two single core cables PVC insulated and un-sheathed 10 sqmm (Nominal Area) FRLS stranded copper conductor drawn into PVC concealed conduit, including one run 6 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 10 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn into PVC concealed conduit, including one run 6 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in repalcement MCB Distribution Board double door of sheet metal TPN 4 way with 415 Volts complete with and including MCCB 63 Amps 4 Poles with fixed thermal magnetic setting with breaking capacity not less than 16 KA complete all as specified & directed by Engineer-in-Charge.
S&F MCB SP&N 240 volt 40 Amp, 16 KA complete all as specified and directed by Engineer in Charge.
M&L for MS clamp fabricated from MS flat of size 40mmx3mm including nuts, bolts, washers, bending cold or hot drilling holes for bolts in any shape or size for holding GI pipe with pole and wall complete all as specified and directed by Engineer in Charge.
Supply, fixing & hanging Energy efficient Ceiling fan (white colour) 1200mm sweep, AC single phase, 230V, including canopies, three Nos. blades down rod double ball bearing with capacitor 2.5 mfd and making connection with including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan including marking of MES number, complete all as specified and directed by the engr-in-charge . Make : Khaitan, Orient, Crompton Greaves, Havells, Legrand
Supply, fixing & hanging Energy efficient Ceiling fan (white colour) 1400mm sweep, AC single phase, 230V, including canopies, three Nos. blades down rod double ball bearing with capacitor 2.5 mfd and making connection with including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan including marking of MES number, complete all as specified and directed by the engr-in-charge . Note : The length of suspension rod shall be as per site requirements. Make : Khaitan, Orient, Crompton Greaves, Havells, Legrand
S&F fan regulator electonic (socket) type, single phase 230 volts to be fixed on laminated sheet top cover and connecting up complete including making up ventilation holes in laminated sheet top cover complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling fan hooks 12mm to 15mm rod in S shape to the ceiling rod including chipping and cleaning with necessary work in RCC roof complete all as specified and directed by Engineer-in-Charge.
S&F of air termination rod 12 mm dia single pointed 300 mm long along with base plate welded at bottom of termination rod,of size 10 cm long fabricated out 25x3 mm thick aluminium strip along with making 9 mm dia for fixing in fastners (wooden block) complete all as specified and directed by Engineer -in-Charge.
M&L for aluminium strip 25mmx3.15mm complete with saddles and fixing screws etc for roof condutors and down conductors above ground complete all as specified and directed by Engineer -in-Charge.
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron strip complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 50mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position.
M&L for test points as per IS specifications of shape and size as approved by GE and Engineer-in-Charge, made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed by Engineer -in-Charge.
M & L for PCC Block of size 25 cm x 25cmx30cm height in PCC (1:2:4) type B-1 using 20mm graded stone aggregate providing 02 Nos. MS fastner at the top of the block by using 8/9mm dia 20cm long bolts with T junction of 10cm & embeded in the PCC block, keep 7 cm portion of the bolt above the upper surface of PCC block alongwith 02 Nos washers and nuts etc complete all as specified and directed by Engineer-in-Charge
S&F wooden block of locally available hard wood of size 25 x 10 x 5cm for mounted on top of PCC block for errection of air termination alongwith bolts and nuts and run the roof conductor complete all as specified and directed by Engineer in Charge.
Supply and fix porcelain insulator 11000 volts grade, of size 150mm height and 150mm dia for isolation of conductor from the building wall by provviding 15cm long fastner at every 16cm distance in the wall complete all as specified and directed by Engineer-in-Charge.
Supply and fix GI pipe 40 mm bore light grade for protection of cable laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge.
Supply, fixing and testing LED street light fitting of 45 Watt fitted on 4 to 9 meter high octagonal pole / 9 & 11 meter PCC/Swan neck pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Philips, Wipro, Bentech, Jaquar & Co Pvt Ltd, Syska LED Lights Pvt Ltd (Syska), Halonix technologies Pvt Ltd (Halonix), C & S Electric Ltd, Havells Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Supply, fixing and testing LED street light fitting of 25 Watt fitted on 4 to 9 meter high octagonal pole / 9 & 11 meter PCC/Swan neck pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Philips, Wipro, Bentech, Jaquar & Co Pvt Ltd, Syska LED Lights Pvt Ltd (Syska), Halonix technologies Pvt Ltd (Halonix), C & S Electric Ltd, Havells Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Supply & fixing in replacement street light bracket fabricated made out of GI Tubing light grade 40mm bore bend to the shape as directed and of length 1.0 mtr complete with mounting MS clamp of flat iron 45 x 5 mm of suitable length 04 pairs including nut bolts etc of suitable size and painting to MS clamps with two coats of aluminum paint over one coat of red oxide metal primer complete all as specified and directed by the engineer in charge.
Supply & fixing in replacement of PVC insulated multi stranded aluminium conductor PVC cable sheathed 2.5 sqmm single core and making connection of street light fittings with overhead lines/ UG cable complete all as specified and directed by Engineer-in-Charge.
NEW AMRITSAR CONSTRUCTION COMPANY
Singla Electricals
GS and Co
AP BUILDERS
DEEPAK ENTERPRISES
UNITED ENGINEERING CORPORATION
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .