Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹25.9 L+₹2.0 L (8.38%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹27.6 L+₹3.6 L (15.1%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹31.5 L+₹7.6 L (31.7%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
16 Dec 2019, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Provision of street lights LT Electric Supply Network and allied works under GE Utilities Udhampur
2019_MES_295456_2
GE/U-35/2019-20
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹57,000
Yes
4 Feb 2020
26 Nov 2019
17 Dec 2019
26 Nov 2019
16 Dec 2019
3 Dec 2019
Amount
Dismantling old unserviceable GI earthing /cradle guard of any description.
Dismantling of old unserviceable/broken/jointed ACSR conductor and earth wire from poles and removing from site of work complete all as specified and directed by the Engineer-in-Charge.
Dismantling of old unsv concrete poles/struts, any size complete all as specified and directed by the Engineer-in-Charge.
Dismantling cross-arms of MS channel or angle sections etc complete all as specified and directed by the Engineer-in-Charge
Dismantling insulators any type, any size complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches in any type of soil not exc 1.5m wide and exc 1.5m but not exc 3.0 m in depth for foundation of poles etc or for laying of pipes/cables etc and getting out complete all as specified and directed by the Engineer-in-Charge.
Removing excavated soils to a distacnce n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Returning ,filling in trenches in layers not exc 25cm after laying of cable including spreading, leveling,watering and well ramming complete all as specified and directed by the Engineer-in-Charge.
M&L for sand cushioning to underground cable providing with a layer 8 cm before laying and 15 cm after laying, jointing and testing the cable sand shall be punned down to 18 cm thickness complete all as specified and directed by the Engineer-in-Charge. Note: Only punned thickness of sand shall be measured for payment.
Supply and laying brick of size 230x115x75mm covering with width equal to length of bricks as mechanical protection to cable using sub class 'B' bricks laid flat perpendicular to the axis of the cable complete all as specified and directed by the Engineer-in-Charge.
M&L for providing PCC 1:4:8 type D-2 (using 40mm graded mechanically crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by the Engineer-in-Charge.
M&L for providing Plain cement concrete 1:2:4 type B-1 (using 20mm graded mechanically crushed stone aggregate) as in coping, cable duct, cover slab and becning incl all necessary form work complete all as specified and directed by the Engineer-in-Charge.
S&F steel tubular swaged poles type 410-SP-31 (9 mtr long) errected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and external portion embedded in concrete, making five black and white bands with synthetic enamel paint at lower portion of pole each 300 mm wide alternately and marking pole number with black paint on yellow base at suitable height including taking out & dismantling of old damged PCC Pole complete all as specified and directed by the Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth wire of size 4 mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection GI pipe 15 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
M&L for earth continuity conductor or main earthing lead of galvanised iron strip of size 32 x 6 mm fixed to wall on batton or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation for loop earthing etc as required complete all as specified and directed by the Engineer-in-Charge.
S&F MS channel/angle iron/flat iron of required size and bent to shape as cross arms, bracing and support including, MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting two coats of synthetic enamel paint (Aluminium shade) over a coat of red oxide primer complete all as specified and directed by the Engineer-in-Charge.
S&F of shackle type porcelain vitreous white, brown or green insulator including galvanized mild steel straps of size 32x3mm and bolt of size 12mm dia, washers and nuts of 75mm height & 90mm dia for working pressure 1100 V grade complete all as specified and directed by the Engineer-in-Charge.
S&F pin type porcelain vitreous white, brown or green insulator including galvanized mild spindle ,two galvanised iron washer and one galvanised iron nut, 50mm height,65mm dia for working pressure 1100 volt grade 100mm height and 65mm dia complete all as specified and directed by the Engineer-in-Charge.
S&F Danger notice Board of size 20 cm X 15 cm and 1.6 mm thick with mild steel sheet vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS Clamps, bolts and nuts of approved size for LT installation of 1.1 KV/440Volt structure Yard complete all as specified and directed by the Engineer-in-Charge.
S&F loop type insulator and porcelain vitreous white or brown large size with over all dimensions 65 mm x 90 mm clearance of hole 16 mm complete all as specified and directed by the Engineer-in-Charge.
S&F loop type insulator and porcelain vitreous white or brown large size with over all dimensions 140 mm clearance of hole 25.5 mm complete all as specified and directed by the Engineer-in-Charge.
S&F in replacement Stay assembly complete with accessories as shown in electrical plate no.1 of SSR Part-I (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16mm dia stay rod complete all as specified and directed by the Engineer-in-Charge.
S&F in replacement Stay assembly complete with accessories as shown in electrical plate no.1 of SSR Part-I (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 20mm dia stay rod complete all as specified and directed by the Engineer-in-Charge.
S&F aluminum conductor steel reinforced (ACSR) on poles, stretched on LT poles without any kink and bends of various sizes as per site required complete including fixing to insulator with aluminum binding wire complete all as specified and directed by the Engineer-in-Charge.
S&F galvanized steel wire 4mm dia for continuous earth wire on poles and cradles at road crossing with fixing arrangement complete all as specified and directed by the Engineer-in-Charge.
Cleaning the existing exposed surfaces of steel tubular pole of 9 Metre long including cross arms, brackets, clamps etc and M&L painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternatively and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by the Engineer-in-Charge.
Cleaning the existing exposed surfaces of steel tubular pole of 11 Metre long including cross arms, brackets, clamps etc and M&L painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternatively and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by the Engineer-in-Charge.
Supply, laying, jointing and testing of XLPE insulated, served with inner sheating of PVC tape armoured with steel wire over PVC sheathed heavy duty electric cable with aluminium conductor strandard 1100 volts grade of size, 16 sqmm 4 core laid in trenches, ducts etc complete including taking out the old unserviceable LT cable all as specified and directed by the Engineer-in-Charge.
Description all as per srl item No 30 here-in-before but size of cable 25 Sqmm 4 core.
Description all as per srl item No 30 here-in-before but size of cable 35 Sqmm 3.5 core.
Description all as per srl item No 30 here-in-before but size of cable 50 Sqmm 3.5 core.
Description all as per srl item No 30 here-in-before but size of cable 70 Sqmm 3.5 core.
Description all as per srl item No 30 here-in-before but size of cable 95 Sqmm 3.5 core.
Description all as per srl item No 35 here-in-before but size of cable120 Sqmm 3.5 core.
Description all as per srl item No 30 here-in-before but size of cable185 Sqmm 3.5 core.
Description all as per srl item No 30 here-in-before but size of cable 240 Sqmm 3.5 core.
M&L PVC insulated 1.5 sqmm single core multi stranded copper conductor from KIOSK box to street light fitting complete all as specified and directed by the Engineer-in-Charge.
M&L offload changeover switch with enclosure of capacity 32 Amps, 4 pole, 415 V, AC 50 Hz complete all as specified and directed by the Engineer-in-Charge.
Description all as per srl item No 45 here-in-before but change over switch of capacity 63 Amps.
Description all as per srl item No 45 here-in-before but change over switch of capacity 100 Amps.
Description all as per srl item No 45 here-in-before but change over switch of capacity 200 Amps.
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel made out of 3.15 mm thick CRCA steel sheet mounted on 45 cm long legs made out of 45 x 45 x 5 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15 x 15 x 20 cm , front openable, lockable / openable by keys having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice. The LT Panel shall be suitable to accomodate the following equiptments :-
(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for Phases & neutral - 01 set of 04 Nos (b) Control wiring with FRLS suitable size but not less than 1.5 sqmm copper wire single core - 01 Job Incoming:- (c) MCCB 4 pole , Ics=100%Icu- 50 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. Outgoing :- (d) On load Change over switch 250 Amps 4 pole -01 No. (e) MCCB 4 Pole, 100A-Ics=100%Icu-25 KA 415 volts with thermal adjustable and fixed mahnetic setting with extended terminals-01 No. (f) PCC 1:3:6 type C-2 for grouting 4 legs of feeder pillar box (g) Astronomical time switch timeline distribution borad 32 Amps TP/230 volt - 01 No Note: - (i) Rates quoted by the contractor shall be deemed to include for:- (ii) Connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (iii) Necessary PCC and earth work required for the grouting of legs of LT Panel complete all as specified and directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15 x 15 x 20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
(d) MCCB 4 pole , Ics=100%Icu- 18 KA, 415 Volts, 63 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. (e) PCC 1:3:6 type C-2 for grouting 4 legs of LT Panel. (f) Astronomical time switch timeline distribution borad 32 Amps TP/230 volt. (g) Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint. (h) Cable entry gland made out of CP brass as per site requirement for incoming and outgoing cable of size upto 240 sqmm 3.5 core -01 Job (j) Blank space for MCCB of rating upto 100 Amps ,4 pole 25 KA -01 No Note :- (i) Rates quoted by the contractor shall be deemed to include for:- (ii) Connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (iii) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs all as directed by Engineer-in-Charge.
Supply and fix modular box made of FRP / inpact resistance plastic & heat resistant materials including size 200 x 160 x 98 mm with IP 65, MCB provison suitable connection for three phase armoured enclosure weather proof , water proof, dust proof internally embedded gas kit with provision of cable entry through similar IP protected matric size gland haff turn screw of openeeble lid .screw is made out of polycarbonate material alongwith MS /MS powder coted/ galavinsed pole mounted clamp of required size (OD of the pole) complete all as specified and directed by the Engineer-in-Charge. Make: Hensel / Sintex/Havells
M&L for GI tubing medium grade 25mm bore used for cable protection, under road / on pole including all fittings including taking out the old unserviceable GI tubing/ clamps if required including necessary work. Make: Tata/Jindal/Parkash surya
M&L for GI tubing medium grade 40mm bore used for cable protection, under road / on pole including all fittings including taking out the old unserviceable GI tubing / clamps if required. Make: Tata/Jindal/Parkash surya
M&L for GI tubing medium grade 50mm bore used for cable protection, under road / on pole including all fittings including taking out the old unserviceable GI tubing / clamps if required. Make: Tata/Jindal/Parkash surya
M&L for GI tubing medium grade 80mm bore used for cable protection, under road / on pole including all fittings including taking out the old unserviceable GI tubing / clamps if required. Make: Tata/Jindal/Parkash surya
M&L for GI tubing medium grade 100mm bore used for cable protection, under road / on pole including all fittings including taking out the old unserviceable GI tubing / clamps if required. Make: Tata/Jindal/Parkash surya
M&L for fixing new street light bracket made out of GI pipe medium grade 40 mm bore approx length not less than 150 cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting. Welding drilling holes, nut, bolts washer etc including one coat of red oxide primer and two coats of aluminium paint on MS work complete all as directed including taking down existing unserviceable bracket complete all as specified and directed by the Engineer-in-Charge.
Supply, installation, connecting, commissioning and testing 12.5 mtr galvanised high mast system, complete all as specified of make Bajaj/Crompton greaves, Wipro/ Surya & comprising of the following :- (a) One No, mast shaft in two section/ One section/ Polygonal shape, made 355 grade as per BS-EN 10025/gavanised as per BS EN ISO1461 with bottom /top dia and thickness of system to be as BS EN ISI 1461 suitable for wind Velocity of udhampur city as per IS 875 Part-3 alongwih raising lowering system comprising of head frame liminaire carraige suitable to installation 08 Nos luminaires in symmetrical arrangement, double drum winch 5 mm dia mtr SS wire rope of breaking capcity 2350 Kg /rope and AISI 316,7/19 instruction trailing cable connector, integral power tool reversible motor 440v, 50hz,1/1.5 HP for raising and lowering operation @ 3 mtr /min (As per OEM recommendation) of High Mast, manual handle, junction box etc. (b) SS foundation bolts 06 Nos, M24x580mm alongwith nuts, washers, anchor plates and templates as per the design and drawing of manufeacture.
(c) Materials and labour for outdoor stand mounted MS fabricated LT Panel with 63 Amp TPN MCB incomer, single dial time switch, 40 Amp TP contactor, 2 Nos, 9 A and raise lower push bottons with wiring of suitable size copper wire of control circuit for automatic switching on & OFF of the mast lights and suitable control for operation of power tool complete all as specified and as directed) - 01 Job) (d) Material and labour for construction of suitable foundation with M20 grade concrete for the high mast consirdering the safe soil bearing capacity as site as per manufacture design including excavation earth work & removal of surpluse soil/ debries to a distance n exc 50 mtrs etc) 01 Jobs). (e ) Material and labour for wiring of power tool for raising and lowering of high mast and for luminaires and for Aviation light fixed on mast. Note :- Cost of foundation (including excavation. Earth work & PCC) feeder pillar box with accessories complete. Foundation bolts and wiring is also deemed to be included the quoted rate against high mast system.
S&F LED flood light of 150 watt LED with epoxy grey powder coated high pressure dia cast aluminium housing with toughened glass having IP-66 degree of protection, individual LED's must have across and along the road with system luminaries effcacy > 100 lumens per watt, related colour temperature (CCT) of 5700 luminaries should have surge protection upto 05 KV and having additional surge protection upto 10 KA for driver, PF> 0.9 and T.H.D < 10% complete all as specified and directed by the Engineer-in-Charge. Make: Crompton/Wipro/Philips
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle LT Panel made out of 3.15 mm thick CRCA steel sheet mounted on 45 cm long legs made out of 45 x 45 x 5 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm, front openable, lockable / openable by keys having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice. The LT Panel shall be suitable to accomodate the following equiptments :- (a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for Phases neutral - 01 set of 04 Nos (b) Control wiring with FRLS suitable size but not less than 1.5 sqmm copper wire single core - 01 Job (c) MCCB 4 pole , Ics=100%Icu- 50 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No. (d) On load Change over switch 160 Amps4 pole -01 No. (e) PCC 1:3:6 type C-2 for grouting 4 legs of LT Panel Note for Serial item No 44, 45, 53.01 (c) (only panel of high mast) & 55: (i) Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint. (ii) Contractor has to procure the panels directly from the manufacturer as specified in PS and submit origianl purchase vouchers & test certificates thereof. Make: Schneider/ Legrand/ABB/Siemens
MOHAN LAL AND SONS
FANGALIA TRADERS
vijay kumar gupta and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .