SR DEE/G
16 conditions · 5 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "totalcontractual payments" in the previous three financial years, as per the audited balancesheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered forcalculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Valid Electrical contractor license as per IE rules 1956, Clause 45.
The tenderer must have successfully completed or substantially completed any one ofthe following categories of work(s) during last 07 (seven) years, ending last day of monthprevious to the one in which tender is invited: (i) Three similar works each costing notless than the amount equal to 30% of advertised value of the tender, or (ii) Two similarworks each costing not less than the amount equal to 40% of advertised value of thetender, or (iii) One similar work costing not less than the amount equal to 60% ofadvertised value of the tender.Substantially completed work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender.
SIMILAR NATURE OF WORK : (As per CESE/KKK's note no. EL/112/0 dated 19.8.2013): "Repair/Rehabilitation/Reconditioning of compressors and accessories including wiring works of RMPU/under slung AC equipments in AC coaches."
Valid Electrical Supervisor's License
27 conditions · 1 needing a document upload
Following Annexures duly filled and signed are to be uploaded online prior to Closing of Tender. Annexures are available at Upload/View Document menu in Home Page of IREPS portal for works tender. 1. The details of the works completed by the tenderer during the last three years to be filled in Annexure-I. 2. The details of Plants and Machinery with the tenderer to be filled in Annexure- II. 3. Details of Personnel and Organization of the Tenderer to be filled in Annexure- III. 4. Details of Works presently on hand of the Tenderer to be filled in Annexure- IV. 5. The details regarding Association of Railway Officer(s) with the tenderer to be filled in Annexure-V. 6. List of the Arbitration cases of the Tenderer during last Five years to be filled in Annexure-VI. 7. List of the Court cases of the Tenderer during last Five years to be filled in Annexure- VII. 8. NEFT MANDATE FORM. All Payments to the agency (including the refund of the Earnest Money of the unsuccessful bidder preferably) will be remitted through NEFT. The Tenderer is required to submit Bank details and A/C No. etc. in Annexure-VIII. 9. Documents related to Credentials as per eligibility criteria: (For tender value above Rs. 50 Lakh). 10. Format (Declaration of tenderer) to be uploaded by tenderer as per "Document Verification Certificate", available in home page, view document. 11. Tenderer shall exercise an Option in writing in favour of taking payment due against the tender through 'Letter of Credit' arrangement. 12. All necessary papers in support of eligibility criteria. 13. Special condition mandatory updation of Labour data "Annexure-C". 14. Contractor should upload Electrical contractor license as per IE rules 1956, clause 45. 15.Contractor should upload Electric supervisor license or Electric supervisor's certificate of competency along with tender offer.
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days
This tender complies with public procurement policy (Make in India) order 2017, dated 15.6.2017 issued by department of industrial promotion & policy , Ministry of commerce, circulated vide Rly. Board's L/no. 2015/RS(G)/779/5 dated 03.8.2017 and 27/12/2017. The definition & calculation of content in accordance with the make in India policy as approved by PCEE is 50% of minimum local content(MLC).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Annual corrective maintenance contract of Fedders Lloyds/ Lloyds/Sidwal/ intech/ Amit/ Doulatram/Stesalite etc. make RMPU plants of AC coaches, (ICF & LHB type) at MLDT & BGP for the period of 3 years.
EL-MLDT-E-TENDER-414
EL-MLDT-E-TENDER-414
Open
Works - General
36 Months
Maldah, West Bengal
₹0
₹3.9 L
17 Mar 2026
23 Feb 2026
3 Mar 2026
161 items across 1 schedule · ₹4,83,33,654.81 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of new scroll Compressor ZR-61KC- 2TFD-523 as per RSDO specification . (MLDT- 30 , BGP-40 ) | Each | 70.00 | 34,888.64 | 24,42,204.8 |
| 2 | Removal of defective Compressor and re- fitment with new one. (all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr.SEE/ACC/BGP) (MLDT-30 , BGP-40 ) | Each | 70.00 | 7,250.59 | 5,07,541.3 |
| 3 | Supply of new blower motor 1.5 HP 1400 RPM with TOP (Make-RDSO approved source) SR- 075-1027) (MLDT-20 , BGP-40 ) | Each | 60.00 | 12,444.78 | 7,46,686.8 |
| 4 | Removal of defective blower motor and fitment with new one with released blower runner (A+B) (Defective to be returned to Sr.SEE/ACC/BGP) (MLDT-20 , BGP-40 ) | Each | 60.00 | 1,982.82 | 1,18,969.2 |
| 5 | Supply of new condenser fan motor 1 HP/1400 RPM with TOP(Make-RDSO approved source) SR-075-1028 (MLDT- 40 , BGP-50 ) | Each | 90.00 | 11,432.99 | 10,28,969.1 |
| 6 | Removal of defective condenser fan motor and fitment ofnew one with TOP & released fan blade. (Defective tobe returnd to Sr.SEE/AC/BGP) (MLDT- 40 , BGP-50 ) | Each | 90.00 | 1,831.32 | 1,64,818.8 |
| 7 | Supply of new plastic fan with Aluminium hub (SR-075-1036) (MLDT- 30, BGP-70) | Each | 100.00 | 5,268.91 | 5,26,891 |
| 8 | Removal of defective plastic fan with Aluminium hub and replacement with new(SR- 075-1036)(Defective to be returnd to Sr.SEE/AC/BGP, MLDT) (MLDT- 30 , BGP-70 ) | Each | 100.00 | 1,762.98 | 1,76,298 |
| 9 | Supply of new SS welded round guard.(SR-075- 1041) of condenser fan motor. (MLDT-10, BGP- 10) | Each | 20.00 | 2,398.96 | 47,979.2 |
| 10 | Removal of defective SS welded round guard and refitment with new one in condenser fan motor. (Defective to be retuned to Sr.SE/AC/BGP, MLDT ). (MLDT-10, BGP-10) | Each | 20.00 | 896.6 | 17,932 |
| 11 | Leak testing of refrigerant system by charging Supply of N2 Gas (N-2 gas will be supplied by firm) (MLDT-150, BGP-150) | Each | 300.00 | 3,525.43 | 10,57,629 |
| 12 | Rectification of leakage after flushing the system with N2 Gas and charging of refrigerent R-407 / R-22 or other refrigerant gas .( Brazing kit, Vacuum pump, N2 gas, refrogerant gas to be supplied by Firm) (MLDT- 150, BGP-150) | Each | 300.00 | 2,525.31 | 7,57,593 |
| 13 | Supply & removal of defective Drier filter (1/2"Solder type) SR-075-1019 and refitment by new one. (all associated jobs e.g. brazing, leak testing etc. alongwith all type of gas & vacuum pump reqd. will be supplied by firm). (MLDT-40, BGP-40) | Each | 80.00 | 7,913.89 | 6,33,111.2 |
| 14 | Supply of new Hartige (Couplers) connector 24 pin SR-075-1001. (MLDT-15, BGP-35) | Each | 50.00 | 8,143.39 | 4,07,169.5 |
| 15 | Removal of defective/damage Hartige (Couplers) connector 24 pin & refitment with new one. (Defective to beretuned to Sr.SE(AC)/BGP, MLDT). (MLDT-15, BGP-35) | Each | 50.00 | 2,261.15 | 1,13,057.5 |
| 16 | Supply of new Hartige (Couplers) connector 16 pin SR-075-1002.(MLDT-10, BGP-20) | Each | 30.00 | 7,035.29 | 2,11,058.7 |
| 17 | Removal of defective /damaged Hartige (Couplers) connector 16 pin and replacement with new one. (Defective to be retuned to Sr.SE/AC/BGP, MLDT).(MLDT-10, BGP-20) | Each | 30.00 | 2,003.29 | 60,098.7 |
| 18 | Supply of new Dumper Actuator SR-075-1046 ( BGP-2) | Each | 2.00 | 6,412.12 | 12,824.24 |
| 19 | Removal of defective /damage Dumper Actuator and replacement with new one. (Defective to be retuned to Sr.SE/AC/BGP, MLDT ). ( BGP-2) | Each | 2.00 | 1,623.25 | 3,246.5 |
| 20 | Supply of new male - female plug & socket for Dumper actuator SR-075-1046 ( BGP-2) | Each | 2.00 | 1,059.85 | 2,119.7 |
| 21 | Removal of defective/damage plug & socket for Dumper Actuator and replacement with new one.(Defective to be retuned to Sr.SE/AC/BGP, MLDT).( BGP-2) | Each | 2.00 | 892.2 | 1,784.4 |
| 22 | Supply of new Pressure Transmiter (0-10 bar SR-075-1010) (MLDT-30, BGP-40) | Each | 70.00 | 8,544.63 | 5,98,124.1 |
| 23 | Removal of defective Pressure Transmiter and replacement with new one SR-075-1010. (all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be retuned to Sr.SE/AC/BGP, MLDT). (MLDT-30, BGP-40) | Each | 70.00 | 2,495.84 | 1,74,708.8 |
| 24 | Supply of new Pressure Transmiter (0-40 bar) SR-075-1011 (MLDT-30, BGP-40) | Each | 70.00 | 8,562.51 | 5,99,375.7 |
| 25 | Removal of defective Pressure Transmiter (0- 40 bar)and replacement with new one SR-075- 1011.(all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be retuned to Sr.SE/AC/BGP, MLDT). (MLDT-30, BGP-40) | Each | 70.00 | 2,495.84 | 1,74,708.8 |
| 26 | Supply of protection for heater (OHP), SR-075- 1066. (MLDT-50, BGP-100) | Each | 150.00 | 1,537.9 | 2,30,685 |
| 27 | Removal of defective protection for heater (OHP) and replacement by new one. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT- 50, BGP-100) | Each | 150.00 | 2,586.24 | 3,87,936 |
| 28 | Supply of new glass bulb Cartridge + 130 degree and replacement by new SR-075-1015 . (Defective to be returned to Sr.SE(AC)/BGP, MLDT) (MLDT@45<44@ BGP-140) | Each | 200.00 | 1,445.98 | 2,89,196 |
| 29 | Supply of new ESTI switch assembly with cartidge. SR-075-1014. (MLDT-10, BGP-15) | Each | 25.00 | 14,179.52 | 3,54,488 |
| 30 | Removal of defective ESTI switch assembly with cartidge replacement by new complete assembly SR-075-1014. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT-10, BGP-15) | Each | 25.00 | 2,376.73 | 59,418.25 |
| 31 | Supply of new Air Heater set consisting 400W(15 nos)coil with insulated backalite sheet. (MLDT-10, BGP-20) | Each | 30.00 | 10,046.29 | 3,01,388.7 |
| 32 | Removal of defective Air Heater set replacement by new one. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT-10, BGP-20) | Each | 30.00 | 1,623.89 | 48,716.7 |
| 33 | Supply of new Low pressure control switch (auto reset) SR-075-1037. (MLDT-15, BGP-45) | Each | 60.00 | 3,080.96 | 1,84,857.6 |
| 34 | Removal of defective Low pressure control switch (auto reset) & replacement by new one SR-075-1037 (all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will supplied by firm). (Alco make to Alco make and Danfoss make to Alco make). Danfoss make-KP-1/Alco make PS3-AP3 HNK4/1.5b. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT-15, BGP-45) | Each | 60.00 | 3,036.82 | 1,82,209.2 |
| 35 | Supply of new High pressure control switch (auto-reset).(SR-075-1038) (Alco make to Alco make and Danfoss make to Alco make) Danfoss make-KP-5/Alco make-PS3-WP HNK27/21 (MLDT-20, BGP-40) | Each | 60.00 | 3,004.04 | 1,80,242.4 |
| 36 | Removal of defective High pressure control switch (auto reset) and replacement by new one(all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT-20, BGP-40) | Each | 60.00 | 3,036.83 | 1,82,209.8 |
| 37 | Supply of new Control pressure switch (auto- reset)(Alco make to Alco make and Danfoss make to Alco make)Danfoss make-KP-5/Alco make-PS3-A4P HNK23/20' +/-0.3 bar (MLDT- 25, BGP-35) | Each | 60.00 | 3,038.21 | 1,82,292.6 |
| 38 | Removal of defective Control pressure switch (auto reset) and replacement by new one (all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT-25, BGP-35) | Each | 60.00 | 2,936.6 | 1,76,196 |
| 39 | Supply of new Expansion Valve and refitment by new one after removing SR-075-1039. (all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT-40, BGP@45<41@ | Each | 100.00 | 12,261.25 | 12,26,125 |
| 40 | Supply of new Liquid leval cum moisture idicator, SR-075-1021. (MLDT-10, BGP-15) | Each | 25.00 | 1,202.36 | 30,059 |
| 41 | Removal of defective Liquid leval cum moisture idicator and refitment with new one SR-075-1021. (all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm. (MLDT-10, BGP-15) | Each | 25.00 | 3,067.55 | 76,688.75 |
| 42 | Supply of new Evaporator coil - Left hand SR- 075-1042/ Right hand -SR-075-1043 (MLDT-3, BGP-4) | Each | 7.00 | 50,113.17 | 3,50,792.19 |
| 43 | Removal of defective Evaporator coil - Left hand /Right hand & replacement with new one as required. (all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT) (MLDT-3, BGP-4) | Each | 7.00 | 11,795.22 | 82,566.54 |
| 44 | Supply of new Condenser coil- Left hand SR- 075-1044/Right hand SR-075-1045. (MLDT-3, BGP-4) | Each | 7.00 | 61,874.1 | 4,33,118.7 |
| 45 | Removal of defectiveCondenser coil- Left hand SR-075-1044/Right hand SR-075-1045 & fitment with new one as required. (all associated jobs e.g. brazing, leak testing etc. alongwith all types of gas & vacuum pump reqd. will be supplied by firm.) (Defective to beretuned to Sr.SE(AC)/BGP, MLDT) (MLDT-3, BGP-4) | Each | 7.00 | 11,866.43 | 83,065.01 |
| 46 | Supply & replacement of HP gauge (0 to 40 bar) (Sifam make)SR-075-1053 with new one. ( MLDT-20, BGP-30) | Each | 50.00 | 12,121.76 | 6,06,088 |
| 47 | Supply & replacement of LP gauge (0 to 10 bar) (Sifam make)SR-075-1052 with new one. ( MLDT-20, BGP-30) | Each | 50.00 | 12,121.76 | 6,06,088 |
| 48 | Supply of new Rotary switch of AC "Off-on" SR- 075-1048 (MLDT-20, BGP-40) | Each | 60.00 | 1,149.57 | 68,974.2 |
| 49 | Removal of defective Rotary switch of AC "Off- on" and refitment with new one. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). (MLDT- 20, BGP-40) | Each | 60.00 | 662.37 | 39,742.2 |
| 50 | Removal of defective Selector switch for pressure gauge meter for four no. compressor SR-075-1050 and fitment with new one. (Defective to be retuned to Sr.SE(AC)/MLDT, BGP). (MLDT-15, BGP-25) | Each | 40.00 | 1,640.53 | 65,621.2 |
| 51 | Removal and replacement of defective Hygrostat 35 - 100%. SR-075-1022 with new one. (MLDT-10, BGP-15) | Each | 25.00 | 13,849.82 | 3,46,245.5 |
| 52 | Supply of new Temperature Sensor (Liberhan make controller) FA SR-075-1059. (MLDT-10) | Each | 10.00 | 7,099.56 | 70,995.6 |
| 53 | Supply of new compressor contactor Type- LS1BK 00 DC 110 V(With or TAL 40-30 01+RT5/150 CAS - 22 M ABB make or RDSO/RCF approved make. ( MLDT-40, BGP-60 ) | Each | 100.00 | 5,093.38 | 5,09,338 |
| 54 | Removal of defective compressor contactor and refitment with new one. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). ( MLDT-40, BGP60 ) | Each | 100.00 | 646.88 | 64,688 |
| 55 | Supply of new condenser motor contactor Type-L54K 10E DC110V(With Diode) 77.137 V DC AEG Make or TAL 16 - 30 01/110V DC+RT 5/150+CAS-01ABB make or RDSO/RCF approved make. ( MLDT-30, BGP-60 ) | Each | 90.00 | 3,237.71 | 2,91,393.9 |
| 56 | Removal of defective condenser motor contactor and replacement with new one. (Defective to be retuned to Sr.SE(AC)/BGP, MLDT). ( MLDT-30, BGP-60 ) | Each | 90.00 | 646.88 | 58,219.2 |
| 57 | Supply of new blower motor contactor type- LS4L10B DC110V (with diode 1HS7K01)77-137 VDC AEG make or TAL16-30 01/110V DC +RTS/150 + CAS-01ABB make or RDSO/RCF approved make. (MLDT-25, BGP-50) | Each | 75.00 | 3,237.71 | 2,42,828.25 |
| 58 | Removal of defective blower motor contractor and refitment with new one. Defective to be handed over to concerned SSE/TL&AC. (MLDT- 25, BGP-50) | Each | 75.00 | 679.57 | 50,967.75 |
| 59 | Supply of new blower motor runner (A type + B type) with new one. (MLDT-10, BGP-25) | Each | 35.00 | 7,279.6 | 2,54,786 |
| 60 | Removal of defective blower motor runner and refitment (A type + B type) with new one. Defective to be handed over to concerned SSE/TL&AC. (MLDT-10, BGP-25) | Each | 35.00 | 2,671.26 | 93,494.1 |
| 61 | Supply of new flapper of servo motor. ( BGP-2) | Each | 2.00 | 1,679.85 | 3,359.7 |
| 62 | Removal of defective flapper of servo motor and refitment of new one. Defective to be handed over to concerned SSE/AC. (BGP-2) | Each | 2.00 | 895.42 | 1,790.84 |
| 63 | Supply of new blower housing complete of different make ( Sidwal, Daulatram, SSK, Fedders etc and as per site demand) with motor and runner by new assembly. (MLDT-2, BGP-2) | Each | 4.00 | 23,198.99 | 92,795.96 |
| 64 | Removal of defective blower housing complete with motor and runner by new one. Defective to be handed over to concerned SSE/AC. (MLDT-2, BGP-2) | Each | 4.00 | 2,643.77 | 10,575.08 |
| 65 | Supply of Electronic controller (SRMC-20/22L) compatible with all type of LHB AC coaches with all sensors ( microprocessor with matching sensor & digital display unit as per RDSO spec) . (MLDT-20, BGP-25) | Each | 45.00 | 1,75,237.1 | 78,85,669.5 |
| 66 | Replacement of defective Electronic controller (SRMC-20/22L) and refitment with new one with all sensors. Defective to be handed over to concerned SSE/AC. (MLDT-20, BGP-25) | Each | 45.00 | 17,815.06 | 8,01,677.7 |
| 67 | Portable data dowloading and analysis unit having processor intel core 15 or higher operating system- windows 11 pro or higher , hard-disc SSD 512 GB or higher . Display 14- inch FSD1920 x1180 or Higher IPS LCD , USB 1.0 & 3.0 HDMI port, wifi, inbuilt camera and speakera and others component accessories like portable charging device and portable back-p shall be having Microshoft office 2019 - accepted brand- HP/DEL/ACCER or similar (MLDT-2, BGP-2) | Each | 4.00 | 54,103 | 2,16,412 |
| 68 | Supply of new fresh air temperature sensor for SRMC-22L microprocessor with LHB RMPU. (MLDT-25, BGP-35) | Each | 60.00 | 3,615.69 | 2,16,941.4 |
| 69 | Removal of defective fresh air temperature sensor for SRMC-22L microprocessor and refitment with new one. Defective to be handed over to concerned SSE/AC. (MLDT-25, BGP-35) | Each | 60.00 | 941.66 | 56,499.6 |
| 70 | Supply of new return/supply air temperature sensors for SRMC-22 L microprocessor with LHB type RMPU. (MLDT-25, BGP-50) | Each | 75.00 | 4,382.03 | 3,28,652.25 |
| 71 | Removal of defective return/supply air temperature sensors for SRMC-22L microprocessor and refitment with new one . Defective to be handed over to concerned SSE/AC. (MLDT-25, BGP-50) | Each | 75.00 | 941.66 | 70,624.5 |
| 72 | Supply & fitment of new double inlet centrifugal blower 415 V, 3 phase , 50 HZ, 120W, 450 cubic meter per hr. Discharge for exhauting air from lavatory/ switch board cabinet, make- RDSO approved source in place of defective one. (MLDT-15, BGP-15) | Each | 30.00 | 17,625.28 | 5,28,758.4 |
| 73 | Supply and fitment of new multifunctional monitoring relay for three main suitable for 750 V system, monitoring phase parameters like phase sequence, phase failure over and under voltage and phase unbalance , make- ABB , Type- CM-MPN-72 in place of defective one. (MLDT-25, BGP-50) | Each | 75.00 | 15,095.47 | 11,32,160.25 |
| 74 | Supply and fitment of new DC-DC converter 110V/24 V 20A model no- 300-Sl-24 or equivalent model make-preshtech, ABB, CSEL, ASTEC in place of defective one. (MLDT-15, BGP- 25) | Each | 40.00 | 20,179.87 | 8,07,194.8 |
| 75 | Supply of sealing compound(280 ml), cleaning agent orion 510-D (10 Lt), return filter and fresh casset filter during schedule attention of coaches. (MLDT-150, BGP-200) | Each | 350.00 | 3,227.73 | 11,29,705.5 |
| 76 | Cleaning of condenser & cooling coil , tightness checking of all motor during schedule attention of AC coaches removal of defective return filters fresh air casset filter and refitment with new one and testing with proper instrument. Defective to be handed over to concerned SSE/AC. (MLDT-150, BGP- 200) | Each | 350.00 | 3,147.17 | 11,01,509.5 |
| 77 | Cleaning of fresh air filter by removing and re- fitment. (MLDT- 50000, BGP-150000) | Each | 200000.00 | 13.67 | 27,34,000 |
| 78 | Cleaning of return air filter by removing and re-fitment. (MLDT- 50000, BGP-150000) | Each | 200000.00 | 13.67 | 27,34,000 |
| 79 | Supply of new supply air duct complete with meta aramid fabric having silicon rubber coating on both sides including frame and associated acceessories for all makes of LHB AC coaches ,as per Sidwal cat no. SR-075-1056 or similar. (MLDT-10, BGP-40) | Each | 50.00 | 17,089.39 | 8,54,469.5 |
| 80 | Labour charges for Removal of defective supply air duct & re-fitment of new one with associated accessories (defective item to be handed over to SSE/TL&AC/BGP, MLDT). (MLDT-10, BGP-40) | Each | 50.00 | 4,940.16 | 2,47,008 |
| 81 | Supply of new set of 2 nos. Return air duct complete with meta aramid fabric having silicon rubber coating on both sides including frame and associated accessories for all make of LHB AC coaches. as per Sidwal cat no. SR- 075-1055 or similar. (MLDT-5, BGP-20) | Each | 25.00 | 7,980.36 | 1,99,509 |
| 82 | Labour charges for Removal of defective return air duct & re-fitment of new one with associated accessories (defective item to be handed over to SSE/TL&AC/BGP, MLDT). (MLDT-5, BGP-20) | Each | 25.00 | 2,632.38 | 65,809.5 |
| 83 | Supply of new set of 2 nos. Fresh air duct complete with meta aramid fabric having silicon rubber coating on both sides including frame and associated accessories for all make of LHB AC coaches. as per Sidwal cat no. SR- 075-1054 or similar. (MLDT-3, BGP-12) | Each | 15.00 | 7,235.93 | 1,08,538.95 |
| 84 | Labour charges for Removal of defective fresh air duct & re-fitment of new one with associated accessories (defective item to be handed over to SSE/TL&AC/BGP, MLDT). (MLDT-3, BGP-12) | Each | 15.00 | 1,812.15 | 27,182.25 |
| 85 | Supply & replacement of MPCB for ventilation fan unit, rating- 3-4 A, Thermal release rate- 2.5-4 A, Class-10, Breaking capacity- 100 ka, pole-3, volt-415 V ac, 1 NO, 1 NC, auxiliary contact block, make- Legrand/ Siemens/ Schneider. (MLDT-15, BGP-35) | Each | 50.00 | 2,708.85 | 1,35,442.5 |
| 86 | Supply & replacement of MPCB for compressor unit, rating- 16 A, Thermal release rate-10-16 A, Class-10, Breaking capacity- 100 ka, pole-3, volt-415 V ac, make- ABB/ Siemens/ Schneider. (MLDT-20, BGP-40) | Each | 60.00 | 6,599.73 | 3,95,983.8 |
| 87 | Supply & replacement of MPCB for condenser fan unit, rating- 2.5 A, Thermal release rate- 1.6-2.5 A, Class-10, Breaking capacity- 100 ka, pole-3, volt-415 V ac,make- ABB/ Siemens/ Schneider. (MLDT-20, BGP-40) | Each | 60.00 | 2,708.85 | 1,62,531 |
| 88 | Replacement of defective hinge/latch lock of side entry hood cover (return air filter cover) by new one . RDSO approved material to be supplied. (MLDT-20, BGP-40) | Each | 60.00 | 837.63 | 50,257.8 |
| 89 | Supply of contactor of 60 KVA transformer , voltage 415 V, rating-200 A, Pole-4, 2 NO+ 2 NC, control voltage- 168-300 V ac with surge supression, Make- ABB/Siemens/Schneider. ( BGP-15) | Each | 15.00 | 22,163.24 | 3,32,448.6 |
| 90 | Supply of feeder contactor Net-1, Net2, voltage-750 V ac, rating-200 A, Pole-4, 2 NO+ 2 NC, control voltage- 380-415 V ac with surge supression, Make- ABB/Siemens/Schneider. (MLDT-10, BGP-20 ) | Each | 30.00 | 22,163.24 | 6,64,897.2 |
| 91 | Supply of new 3 Pole MCB of 6A/10A/16A/20A (For MLDT - 30, BGP -50) | Each | 80.00 | 1,617.83 | 1,29,426.4 |
| 92 | Labour charges for removal of defective MCB & replacement with new 3 pole MCB of 6A/10A/16A/20A (For MLDT - 30, BGP -50) | Each | 80.00 | 1,082.8 | 86,624 |
| 93 | Supply & replacement of of new PCB for LED's. ( MLDT-8 & BGP-2) | Each | 10.00 | 4,984.69 | 49,846.9 |
| 94 | Supply of strainer capillary (RDSO materials to be supplied) (MLDT-5, BGP-10) | Each | 15.00 | 1,434.17 | 21,512.55 |
| 95 | Removal of defective strainer capillary with drier and fitment by new one (all associated job of brazing, leak testing etc along with all types of gas system flushing with N2 , leak test as per SMI , vaccum pump required to be supplied by the firm, defective to be returned to consignee store) ( (MLDT-5, BGP-10) | Each | 15.00 | 5,767.93 | 86,518.95 |
| 96 | Supply & replacement of new brass distributor 8 hole inlet 19 small SR-075-1028 (RDSO Material to be supplied) (MLDT-5, BGP-10) | Each | 15.00 | 734.58 | 11,018.7 |
| 97 | Supply of insulation control relay 415 V net , make- ABB , Cat no. CM IWS.2S (MLDT-5, BGP- 10) | Each | 15.00 | 13,252.94 | 1,98,794.1 |
| 98 | Supply of insulation control relay 110 V net , make- ABB , Cat no. CM IWS.1S (MLDT-5, BGP- 10) | Each | 15.00 | 13,933.55 | 2,09,003.25 |
| 99 | Supply of voltmeter NW 72 for 110 V DC , 0- 150 V , make- AE/Rishabh/ Yokins/L&T (MLDT- 5, BGP-5) | Each | 10.00 | 1,691.33 | 16,913.3 |
| 100 | Supply of voltmeter NW 72 for Net1 & Net2, 0- 800V , 800 V AC , make- AE/Rishabh/ Yokins/L&T (MLDT-5, BGP-5) | Each | 10.00 | 1,691.33 | 16,913.3 |
| 101 | Supply of new suction accumulator for LHB/ICF type RMPU (MLDT-5, BGP-5) | Each | 10.00 | 2,769.34 | 27,693.4 |
| 102 | Removal of defective accumulator & re-fitment with new one including drier. (all types of gas, system flushing with N2 , leak test as per SMI , vaccum pump required will be supplied by the firm ) defective item to be returned to consignee stores. (MLDT-5, BGP-5) | Each | 10.00 | 5,538.68 | 55,386.8 |
| 103 | Supply of new NTC temperature sensor (rated capacity 5 K) with connector for RA/FA/SA for LHB RMPU (MLDT-10, BGP-20) | Each | 30.00 | 2,307.79 | 69,233.7 |
| 104 | Removal & replacement of defective/damaged NTC temperature sensor by new one for LHB RMPU. Defective item to be returned to consignee stores. (MLDT-10, BGP-20) | Each | 30.00 | 692.34 | 20,770.2 |
| 105 | Supply of rotary switch (16 A, 7 pole, 3 position (Auto , Maual, OFF) for LHB RMPU (MLDT-10, BGP-20) | Each | 30.00 | 2,653.95 | 79,618.5 |
| 106 | Removal & replacement of defective/damage rotary switch (16 A, 7 pole, 3 position (Auto , Maual, OFF) for LHB RMPU . Defective to be return to consignee store (MLDT-10, BGP-20) | Each | 30.00 | 1,384.67 | 41,540.1 |
| 107 | Supply of 2A, 1.2 KV AC fuse (Make-SIBA), Fuse size- 8 mmx 50 mm for LHB RMPU (MLDT-500, BGP-500) | Each | 1000.00 | 923.11 | 9,23,110 |
| 108 | Supply of 125 A, NH-1L type, 120 KA, 1000 V AC HRC fuse (Make-SIBA/ETN/Bushman or similar) for LHB coaches (MLDT-200, BGP-300) | Each | 500.00 | 2,538.56 | 12,69,280 |
| 109 | Supply of Refrigerant gas R-407 C (45/47 Kg Cylinder) without cylinder (Empty cylinder will be returned after consumption of gas ) (set- Cylinder) (MLDT-5, BGP-5) | Set | 10.00 | 52,063.63 | 5,20,636.3 |
| 110 | Supply of MCB (Triple pole) 10 A, C-curve, 415 V AC for ventilation fan motor and condenser fan motor . Make- Legrand -DX3-C10 or similar (MLDT-10, BGP-15) | Each | 25.00 | 794.03 | 19,850.75 |
| 111 | Supply of MCB (Triple pole) 20 A, C-curve, 415 V AC for compressor motor . Make- Legrand - DX3-C20 or similar (MLDT-10, BGP-15) | Each | 25.00 | 794.03 | 19,850.75 |
| 112 | Supply of MCB for heater with auxiliaary contact block. Thermal release range, Rated current-16 Amp , C-curve, 415 V AC, breaking capacity- 10 KA, Pole-3 . Make- Siemens - 5SL43167RC +5ST3010 or ABB-SB203 M-C16 or similar (MLDT-10, BGP-15) | Each | 25.00 | 826.89 | 20,672.25 |
| 113 | Supply of MPCB with NO+NC auxiliary for water pump ( 1 to 1.6 Amp) (MLDT-25, BGP-25) | Each | 50.00 | 2,769.37 | 1,38,468.5 |
| 114 | Supply of MPCB with NO+NC auxiliary for Exhaust Fan ( 0.1 to 2.5 Amp) (MLDT-5, BGP-5) | Each | 10.00 | 3,461.68 | 34,616.8 |
| 115 | Supply of MCB (Double pole) 10 A, C-curve, 415 V AC for Light control circuit . Make- Legrand -DX3-C10 or similar (MLDT-10, BGP- 15) | Each | 25.00 | 498.33 | 12,458.25 |
| 116 | Supply of MCB (Double pole) 6 A, C-curve for diagnosis circuit, AC compact control and pump control circuit, light control circuit (MLDT-10, BGP-15) | Each | 25.00 | 498.33 | 12,458.25 |
| 117 | Supply of MCB (Double pole) 16 A, C-curve for DC-DC converter related circuit (MLDT-5, BGP- 10) | Each | 15.00 | 923.11 | 13,846.65 |
| 118 | Supply of selector of power supply (ON/OFF) switch with NO/NC auxiliary contactor . Make- Siemens 3SB50002ABO1+3SB54000E, L&T - EMNCSK1+ECIC or XB5AD21N+ZBE101N+ ZBE102N-Schneider or simlar (MLDT-5, BGP- 10) | Each | 15.00 | 692.34 | 10,385.1 |
| 119 | Supply of feeder selection rotary switch with marking "I-O-II" net-I-local main supply +Net-2 (Change over switch with 0-positon -3 pole) rated Amp- 16 Amp. Make- Siemens 3SB5000- 2D801+ 3SB5400-0A or L&T 6169SCB03TDY or Schneider-XB5AD33N+ ZBE101N+ZBE102NN or simlar (MLDT-15, BGP-25) | Each | 40.00 | 923.11 | 36,924.4 |
| 120 | Supply & replacement of new multifunctional monitoring relay for 3 phase main suitable for 400/480 V AC +/- 15% , 50-60 HZ, control 300- -500 V AC system, monitoring phase parameter, phase sequence, phase failure, over and under voltage and phase unbalance . Make- ABB type M- MPS 415 or Siemens - 7UGOB18-ICA20 or M's Carlo Gavazzi - DPCO1DMA8 400/480 or simlar (MLDT-15, BGP- 25) | Each | 40.00 | 4,015.55 | 1,60,622 |
| 121 | Supply of MCB for RBC cum EBC , rated current -25 Amp, cuyrve-D, rated voltage-415 V,AC, Pole-3P, Breaking capacity-10 KA, make- Siemens- 5SL73258RC or ABB-SB203 M-D25 or L&T- BB30250D or similar. (MLDT-20, BGP-30) | Each | 50.00 | 826.89 | 41,344.5 |
| 122 | Supply of MCB for EBC , rated current -20 Amp, cuyrve-C, rated voltage-415 V,AC, Pole-2P, make- Siemens- 5SL42207RC or ABB-SB202 M- C20 or L&T- BB20200C or similar. (MLDT-10, BGP-15) | Each | 25.00 | 498.33 | 12,458.25 |
| 123 | Supply of MCB for 5 KVA transformer (Primary) , rated current -16 Amp, curve-D, rated voltage-415 V AC, Pole-3P, Breaking capacity- 10 KA, make- Siemens- SL73168RC or ABB- SB203 M-D16 or Schneider- A9N3P16D or similar. (MLDT-10, BGP-10) | Each | 20.00 | 826.89 | 16,537.8 |
| 124 | Supply of MCB for 5 KVA transformer (Secondary) for mobile/Laptop charging circuit , rated current -25 Amp, curve-C, rated voltage-230V AC, Pole-4P, Breaking capacity- 10 KA, make- Siemens- 5SL73168RC or ABB- SB204 M-C25 or L&T- BB20160D or similar. (MLDT-10, BGP-10) | Each | 20.00 | 1,085.05 | 21,701 |
| 125 | Supply of new solonoid valve lower part size 3/8" SR-075-1016 or equivalent as required (all associated job e.g. brazing , leak testing etc alongwith refrigerant gas & vacuum pump will be supplied by firm . (MLDT-5, BGP-5) | Each | 10.00 | 3,219.31 | 32,193.1 |
| 126 | Removal & fitment of solonoid valve lower part size 3/8" SR-075-1016 or equivalent as required (all associated job e.g. brazing , leak testing etc alongwith refrigerant gas & vacuum pump will be supplied by firm . (MLDT-5, BGP- 5) | Each | 10.00 | 3,504.74 | 35,047.4 |
| 127 | Supply of new Display panel with feather touch operation (MLDT-5, BGP-5) | Each | 10.00 | 18,367 | 1,83,670 |
| 128 | Removal of defective /damage Display panel with new one . Defective item to be returned to sonsignee store. (MLDT-5, BGP-5) | Each | 10.00 | 1,476.45 | 14,764.5 |
| 129 | Supply of new heater contactor type LS4K 10B DC 110 (with diode 1HS 7K 01) 77-137 V DC AEG make or TAL 16-30 01/110 V DC +RT5/150 +CA5-01 ABB make or similar (MLDT-10, BGP-10) | Each | 20.00 | 2,950.31 | 59,006.2 |
| 130 | Replacement of defective heater contactor type LS4K 10B DC 110 (with diode 1HS 7K 01) 77-137 V DC AEG make or TAL 16-30 01/110 V DC +RT5/150 +CA5-01 ABB make or similar (MLDT-10, BGP-10) | Each | 20.00 | 610.65 | 12,213 |
| 131 | Supply of new DC/DC converter 110V/24V 1,5 A Type CPE-24V/2.5 A (MLDT-5, BGP-15) | Each | 20.00 | 4,883.45 | 97,669 |
| 132 | Replacement of defective DC/DC converter 110V/24V 1,5 A Type CPE-24V/2.5 A by new one. Defective item to be returned to consignee store (MLDT-5, BGP-15) | Each | 20.00 | 710.98 | 14,219.6 |
| 133 | Supply of new fresh air filter synthetic fibre type (RCAC-016AF) (For MLDT-40, BGP-10) | Each | 50.00 | 762.55 | 38,127.5 |
| 134 | Labour charges for Removal of fresh air filter (old) &replacement with new filter synthetic fibre type (RCAC-016AF)(For MLDT-40, BGP-10) | Each | 50.00 | 604.56 | 30,228 |
| 135 | Supply of new Return air filter synthetic fibre type (RCAC-16R) (For MLDT@45<44@ BGP-15) | Each | 75.00 | 1,806.12 | 1,35,459 |
| 136 | Labour charges for Removal of return air filter (old) &replacement with new filter synthetic fibre type (RCAC-16R)(For MLDT-35, BGP-15) | Each | 50.00 | 743.53 | 37,176.5 |
| 137 | Supply of new HP/LP cut out. (For MLDT-20, BGP-05) | Each | 25.00 | 410.5 | 10,262.5 |
| 138 | Labour charges for Removal of defective HP/LP cut out replacement with new cut out charging additional gas if required (For MLDT-20, BGP- 05) | Each | 25.00 | 2,741.59 | 68,539.75 |
| 139 | Supply of new Vane relay (RCAC-06) (For MLDT-20 &BGP-5) | Each | 25.00 | 1,631.89 | 40,797.25 |
| 140 | Labour charges for Removal of defective Vane relay & replacement with new one (RCAC-06) (For MLDT-20, BGP-5). | Each | 25.00 | 2,224.48 | 55,612 |
| 141 | Supply of new rotary cum switch 63 A 440 V 3 Ph., 3,Pole, ON-OFF , Make-KAYCEE/ SALZER (RCAC-066)(For MLDT-10, BGP-5) | Each | 15.00 | 1,526.17 | 22,892.55 |
| 142 | Labour charges for Removal / replacement of defective rotary cum switch 63 A 440 V 3 Ph., 3, Pole, ON-OFF with new one, Make- KAYCEE/SALZER(RCAC- 066)(For MLDT-10, BGP-5) | Each | 15.00 | 1,145.98 | 17,189.7 |
| 143 | Supply of new rotary-cum switch 16A, 250V, ON-OFF 3 Pole, 3 way without OFF(For MLDT- 10,BGP-5) | Each | 15.00 | 893.27 | 13,399.05 |
| 144 | Labour charges for Removal & replacement of defective rotary-cum-switch 16A, 250V, ON- OFF 3 Pole, 3 way without OFF(For MLDT-10, BGP-5) | Each | 15.00 | 1,145.98 | 17,189.7 |
| 145 | Supply of new rotary cum switch 16A, 250V, DC 2 pole ON-OFF 1 Position,Make-KAYCEE, SALZER(For MLDT-10, BGP-5) | Each | 15.00 | 826.13 | 12,391.95 |
| 146 | Labour charges for Removal of defective rotary-cumswitch and replacement with new rotary cum switch 16A, 250V, DC 2 pole ONOFF 1 Position, Make- KAYCEE, SALZER (For MLDT- 10, BGP-5) | Each | 15.00 | 1,145.98 | 17,189.7 |
| 147 | Supply of new 415/110V, 500 VA isolation type transformer, make- Guru, Logistech etc. (For MLDT-10, BGP-5) | Each | 15.00 | 4,555.99 | 68,339.85 |
| 148 | Labour charges for Removal & replacement of 415/110V, 500 VA isolation type transformer, make- Guru, Logistech etc. (For MLDT-10, BGP- 5) (Defective Transformer to be returned to depot) | Each | 15.00 | 949.32 | 14,239.8 |
| 149 | Supply of timer Electronic/ Pneumatic type of 110V AC coil 0.5 180 Sec.(For MLDT-10, BGP-5) | Each | 15.00 | 9,382.94 | 1,40,744.1 |
| 150 | Labour charges for Removal of defective Timer & replacement with new timerElectronic/ Pneumatic type of 110V AC coil 0.5 180 Sec. (For MLDT-10, BGP-5) | Each | 15.00 | 2,638.96 | 39,584.4 |
| 151 | Supply of new MCB of cap. 63 A, 3 Pole, 415 V. (For MLDT-8, BGP-2) | Each | 10.00 | 1,593.74 | 15,937.4 |
| 152 | Labour charges for Removal of defective Main MCB &replacement with new MCB of cap. 63 A, 3 Pole, 415V.(For MLDT-8, BGP-2) | Each | 10.00 | 485.65 | 4,856.5 |
| 153 | Supply of new MCB of cap,32A for Sealed compressor,3 Pole (For MLDT-8, BGP-2) | Each | 10.00 | 1,861.93 | 18,619.3 |
| 154 | Labour charges for Removal of defective MCB & replacement with new MCB of cap, 32A for compressor motor, 3 Pole (For MLDT-8, BGP-2) | Each | 10.00 | 1,246.18 | 12,461.8 |
| 155 | Supply of new 3 Pole MCB of 6A/10A/16A (For MLDT-20, BGP-5) | Each | 25.00 | 1,861.93 | 46,548.25 |
| 156 | Labour charges for Removal of defective MCB &replacement with new 3Pole MCB of 6A/10A/16A(For MLDT-20, BGP-5) | Each | 25.00 | 1,246.18 | 31,154.5 |
| 157 | Supply of new Single Pole MCB of 2A/4A(For MLDT-10, BGP-5) | Each | 15.00 | 1,246.18 | 18,692.7 |
| 158 | Removal of defective MCB & replacement with new Single Pole MCB of 2A/4A(For MLDT-10, BGP-5) | Each | 15.00 | 1,246.18 | 18,692.7 |
| 159 | Supply of new Electronic thermostat as per latest RDSO ammendment .(MLDT-20 & BGP-5) | Each | 25.00 | 9,167.46 | 2,29,186.5 |
| 160 | Labour charges for Supply & replacement of defective Electronic thermostat with new one . (MLDT-20 & BGP-5) | Each | 25.00 | 1,759.3 | 43,982.5 |
| 161 | Supply of new expansion valve and re-fitment by new one after removing SR-075- 1039 including all associated jobs e.g. brazing, leak testing, etc. alongwith all types of refrigerant gas & vacuum pump required will be supplied by firm. (Make- Danfoss etc.) (MLDT-8, BGP-2) | Each | 10.00 | 16,631.44 | 1,66,314.4 |
| Schedule total | ₹4,83,33,654.81 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
BGFormatforBidSecurity.pdf
ATTACHMENT
GCC-2022uptoACS10.pdf
ATTACHMENT
Checklist.pdf
ATTACHMENT
Technicalcompliances.pdf
ATTACHMENT
CommercialCompliances.pdf
ATTACHMENT
Othercompliances.pdf
ATTACHMENT
414SpecificationofworksAnnexureA.pdf
ATTACHMENT
414Othertenderconditions.pdf
ATTACHMENT
Deploymentofqualifiedengineer.pdf
ATTACHMENT
Mandatorydocumentslist.pdf
ATTACHMENT
TenderDocuments-2022MLDT.pdf
ATTACHMENT
LetterofcreditformatAnnexure-B.pdf
ATTACHMENT
MandatoryupdationLabourdataAnnexC.pdf Labour Data Annexure C
ATTACHMENT
NewDocumentverificationcertificate.pdf
ATTACHMENT
MandatoryupdationLabourdataAnnexC.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .