Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹24.7 L+₹5.2 L (26.8%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹24.8 L+₹5.3 L (27.3%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹27.3 L+₹7.8 L (40.3%)Rejected-AOC | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | L5₹29.7 L+₹10.3 L (52.9%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
GE(H)-30/2020-21
2020_MES_380120_1
GE(H)-30/2020-21
Open Tender
Miscellaneous Works
Item Rate
240 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹70,000
Yes
31 Oct 2020
23 Sept 2020
22 Oct 2020
23 Sept 2020
20 Oct 2020
7 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil etc complete all as specified and as directed.
All as per Serial item No 1.00 (here-in-before) but depth exceeding 1.5 mtr and not exceeding 3.00 mtr.
All as per Serial item No 1.00 (here-in-before) but hard/dense soil.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed. .
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
Taking up bricks laid as cable covers and stacking serviceable brick for reuse at site etc complete all as specified and directed.
Laying only old bricks retrieved from item Srl Item No. 7.00 (here-in-before) as cable covers in trenches etc complete all as specified and directed.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
Taking out the old unserviceable LT underground cable 10 sqmm 2 core 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed . Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
All as per item No 10.00 (here-in-before) but 16 Sqmm 2 core.
All as per item No 10.00 (here-in-before) but 16 Sqmm 4 core.
All as per item No 10.00 (here-in-before) but 25 Sqmm 4 core.
All as per item No 10.00 (here-in-before) but 35 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 50 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 70 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 95 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 120 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 150 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 185 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 240 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 300 Sqmm 3.5 core.
All as per item No 10.00 (here-in-before) but 400 Sqmm 3.5 core.
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 10 Sqmm 2 core all as directed retrieved from item srl No. 10.00 (here-in-before).
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 16 Sqmm 2 core all as directed retrieved from item srl No. 11.00 (here-in-before).
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 16 Sqmm 4 core all as directed retrieved from item srl No. 12.00 (here-in-before).
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 25 Sqmm 4 core all as directed retrieved from item srl No. 13.00 (here-in-before).
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 35 Sqmm 3.5 core all as directed retrieved from item srl No. 14.00 (here-in-before).
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 50 Sqmm 3.5 core all as directed retrieved from item srl No. 15.00 (here-in-before).
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 70 Sqmm 3.5 core all as directed retrieved from item srl No. 16.00 (here-in-before).
Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of 95 Sqmm 3.5 core all as directed retrieved from item srl No. 17.00 (here-in-before).
Supply , laying , jointing, testing and commissioning of size 10 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per item No 32.00 (here-in-before) but 16 Sqmm 2 core.
All as per item No 32.00 (here-in-before) but 16 Sqmm 4 core.
All as per item No 32.00 (here-in-before) but 25 Sqmm 4 core.
All as per item No 32.00 (here-in-before) but 35 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 50 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 70 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 95 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 120 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 150 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 185 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 240 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 300 Sqmm 3.5 core.
All as per item No 32.00 (here-in-before) but 400 Sqmm 3.5 core.
Taking up or down 40mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified & directed.
Taking up or down 50mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified & directed.
Taking up or down 80mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified & directed.
Fixing only 40mm bore steel tubes light grade including fittings on poles/ walls/ under Road / floor all as directed retrieved from item srl No. 46.00 (here-in-before). Note :- Necessary clamps, nut, bolts, washers etc shall be deemed to be included in rates quoted.
Fixing only 50mm bore steel tubes light grade including fittigns on poles/ walls/ under Road / floor all as directed retrieved from item srl No. 47.00 (here-in-before). Note :- Necessary clamps, nut, bolts, washers etc shall be deemed to be included in rates quoted.
Fixing only 80mm bore steel tubes light grade including fittings on poles/ walls/ under Road / floor all as directed retrieved from item srl No. 48.00 (here-in-before). Note :- Necessary clamps, nut, bolts, washers etc shall be deemed to be included in rates quoted.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing u/s earthing all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
All as per srl item No '55.00' (here-in-before) but using galvanized iron strip 25 x 4 mm as earthing lead and GI protection pipe light grade 40 mm bore. NOTE for Srl item no 55.00 & 56.00 :- The unit rate quoted shall includes for protection pipe and GI earth wire 4.00mm /GI strip 25x4mm from top of earth plate up to 7.5 meter above ground level.
M&L in replacement of earth pit, PCC chamber with PCC (1:3:6) type C-1 with RCC precast cover 40 mm thick of mix (1:2:4) type B-1 using 20mm graded crushed stone aggregate and reinforced with 8mm dia high strength TMT steel bars @ 100mm c/c both ways with handle 8mm dia high strength deformed TMT steel bars including excavation and earth work as per Electrical plate No 03 of SSR Part-I (2009) etc complete all as specified and as directed.
S&F in replacement copper conductor cable, multistranded, single core, 1100 Volts grade of 10 sqmm size, connected to bus bar to MCB with copper thimble (on both side) of suitable size complete all as specified & directed.
S&F in replacement MCB TPN of capacity 63A,10 KA, type 'C', 415 volts complete all as specified and directed.
Supply, installation, commissioning and testing in replacement of MCCB 630 Amp ( fixed on existing panel) 415 volt, 4 pole, 36 KA breaking capacity with adjustable current range for overload protection and thermal release complete with spreader terminals (legs) and with proper lugs complete all as specified and as directed.
All as per Srl item No '60.00' (here-in-before) but 400 Amps, 50 KA.
All as per Srl item No '60.00' (here-in-before) but 320 Amps, 36 KA.
All as per Srl item No '60.00' (here-in-before) but 250 Amps, 36 KA.
All as per Srl item No '60.00' (here-in-before) but 200 Amps, 36 KA.
All as per Srl item No '60.00' (here-in-before) but 160 Amps, 36 KA.
All as per Srl item No '60.00' (here-in-before) but 100 Amps, 25 KA.
Disconnecting the electric connection and draw out Air circuit Breaker (ACB) carefully of any make of capacity upto 800 Amps for servicing the ACB by removing dust, cleaning and checking the serviceability of the parts and testing, refixing it after servicing at the original position etc complete all as specified and as directed.
Disconnecting and taking out underground cable, including carry out megger testing of dismantle LT cable of following sizes of length not more than 5 mtr and locating the fault and cutting the faulty damaged portion of cable , connecting with providing new heat shrinkable straight through jointing kit with suitable size , including excavation, returning filling and all connected materials complete all as specified and directed. Note:-Necessary excavation , sand cushioning ,cable cover as bricks etc beyond 5 mtr should be measured and paid separately.
3.5/4 core 10 to 16 Sqmm
3.5/4 core 25 to 50 Sqmm
3.5/4 core 70 to 150 Sqmm
3.5/4 core 185 to 240 Sqmm
3.5/4 core 300 to 400 Sqmm
M&L for cutting the faulty/ damaged end portion of the U/G cables of any type and making good end termination with and including suitable size of aluminium thimble duly crimped with crimping tool and refixing its own position ,including Insulation tape, nut ,bolts etc as required for the following sizes. Note :- Necessary excavation, earth work shall be measured and paid separately if required.
10 Sqmm to 16 sqmm
25 Sqmm to 35 sqmm
50 Sqmm to 70 Sqmm
95 Sqmm to 120 Sqmm
150 Sqmm to 240 sqmm
300 Sqmm to 400 sqmm
M&L in replacement for house service bracket (hook type ) complete made out of 3.0 m long GI pipe 40 mm bore medium grade, two Nos 90 degree bends, MS hook & stay or guy etc complete all as specified and as directed.
S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cable flat or circular of aluminium solid conductors of size 10 Sqmm twin core including taking down existing service connection all as specified & directed.
All as per item No 71.00 (here-in-before) but 16 Sqmm twin core.
Labour only for disconnecting, taking out underground faulty cable from Panel/ Pole/ Transformer, cut out box, DBs or any position of length not more than 4 m in loop of following sizes including excavation and earthwork, taking out bricks and relaying the old cable in loop and making reconnection with LT panel/ Pole /cut out boxes or MCB DBs after dressing of cable leads, including relaying old bricks and returning, filling in soil etc complete all as specified and as directed by Engineer-in-Charge.
Up to 35 Sqmm 4 core
50 Sqmm to 120 Sqmm 3.5 core
M&L in replacement for LT Danger notice plate of size 20 X 15 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures, and conventional skull and bones, in signal red colour and fixed with MS clamps, bolts, and nuts of approved size etc complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in mass concrete including necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
Dismantling unserviceable concrete pole/struts of any size and removing from site complete all as specified and directed.
Supply, erecting & fixing in true vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) duly painted with two coats of aluminium paint over a coat of primer complete all as specified and directed by Engineer- in-charge. Note :- (i) The rate quoted shall deemed to included taking out conductors, earthwire from existing pole and refixing to newly errected pole. (ii) Earth work & PCC shall be measured and paid separately.
Dismantling unserviceable stay assembly complete and removing from site complete all as specified and directed by Engineer- in-charge.
M&L for GI Stay assembly with 20mm dia of stay rod complete with all accessories as shown in electric plate no 1 of MES schedule Part I complete. Note: - Earth work, PCC, loop type insulator shall be measured separately.
S&F loop type insulator, vitreous porcelain, white brown or green with over all dimensions 65 mm x 90 mm, clearance of hole 16 mm suitable for 1100 volts complete all as specified and directed by Engineer- in-charge.
S&F in replacement galvanized stay stranded wire of size 7/4 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
Dismantling unserviceable cross arms, clamps etc and removing from site complete all as specified and directed.
M&L for Cross Arms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts, washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Dismantling insulator any type/ any size from LT poles complete all as specified and directed by.
S&F pin type insulators LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, one galvanised iron nut, 100 mm height, 65 mm dia all as specified and directed.
M&L for providing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including galvanised insulator bolts, nuts 12 mm dia and washer including 31x3mm galvanised mild steel straps, 75 mm height and 90 mm dia of insulator complete all as specified and directed.
Dismantling unserviceable galvanized earth steel wire 3.15 or 4 mm dia and existing hexagonal cradle guard from HT/LT poles and removing binding wire and removal of the same from site complete all as specified and directed.
Supply and fixing of Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia including stretching, sagging and jointing in position as a continuous earth wire on pole and for guarding complete all as specified and directed.
Taking down unserviceable/old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and directed.
Supply and fixing Aluminium conductor steel reinforced (ACSR) of any size for HT/LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape incl jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and directed.
Re-Stringing / Re-stretching including jointing in situ of each span not more than 45 Mtrs between two electric poles having following nos of ACSR conductors including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered :-
5 Nos of ACSR conductors
4 Nos of ACSR conductors
3 Nos of ACSR of conductors Note for Srl Item No 93.00 :- (i) Qty of GI earth wire or ACSR conductor required to be replaced or extended during stringing operation shall be measured and paid separately. (ii) Quoted rate of Each span includes Stringing / stretching of all ACSR conductors i.e. 5, 4 or 3 as mentioned against above respective items.
Prunning / trimming the branches of trees if any along overhead line with any number of conductor, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away complete all as specified and directed by Engineer-in-Charge (The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required). Note :- Trimming of tree branches shall be carried out for any number of conductors in a span surrounded by tree branches.
Surface dressing not exc 15cm deep in soft/loose soil.. Note:-The contractor will ensure that no vegetation grows during the contract period on the area so excavated.
M&L in replacement of old jumper ACSR (conductor size not less than weasel) upto length 1.5 mtr for OH line (any type) complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of PVC separator in position to keep ACSR conductor as equal spacing complete all as specified and directed by Engineer-in-Charge suitable for following Nos of ACSR conductors wire :-
M&L for Boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including S&F HDPE pipe of 150mm dia for 0.4 Mpa working pressure for laying of cable complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) complete, all as directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M&L for 100mm thick PCC 1:3:6 type B2 using 40mm graded crushed stone aggregate as in floor top, surface finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for 40mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in flooring, finished even and smooth with using extra cement complete all as specified & as directed.
M&L for rendering 10mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M/S D.N Choudhary
fauji electric works
M/S KAVITA CONSTRUCTION
m/s Rajesh Kumar
M/S RAJINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .