| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹19.9 L+₹48,446 (2.50%)Rejected-Finance MANDIR ROAD NEW ABADI AKALGARH AIR FORCE STATION HALWARA TEH RAIKOT DISTT LUDHIANA PB 141106 | LUDHIANA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹19.9 L+₹53,040 (2.73%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹20.8 L+₹1.4 L (7.11%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹20.9 L+₹1.5 L (7.67%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Apr 2023, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
REPAIR/MAINT OF LT INFRASTRUCTURE AND ELECTRONIC GADGETS IN DOMESTIC AND TECH AREA AT AF STN BARNALA UNDER GE (AF) HALWARA
2023_MES_585737_1
GE/HAL-77/2022-23
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS E CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹50,000
Yes
26 Apr 2023
14 Mar 2023
15 Apr 2023
14 Mar 2023
13 Apr 2023
29 Mar 2023
Amount
M&L for excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth and making bottom surface to required gradient complete all as specified and directed.
M&L for removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for returning filling in and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed.
M&L for sand cushioning using dry clean sand for protection of underground cable, consolidated and compacted complete all as specified and as directed.
M&L for well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor of any Cross sectional area from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
Supply and laying, jointing & testing XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 6 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing compete all as specified and directed Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately,
All as per Sl item No. 7.00 here-in-before but Cross sectional area 10 sq mm, 2 core
All as per Sl item No. 7.00 here-in-before but Cross sectional area 10 sq mm, 4 core
All as per Sl item No. 7.00 here-in-before but Cross sectional area 16 sq mm, 4 core
All as per Sl item No. 7.00 here-in-before but Cross sectional area 25 sq mm, 4 core.
All as per Sl item No.7.00 here-in-before but Cross sectional area 35 sq mm, 3.5 core
All as per Sl item No.7.00 here-in-before but Cross sectional area 50 sq mm, 3.5 core .
All as per Sl item No.7.00 here-in-before but Cross sectional area 70 sq mm, 3.5 core
All as per Sl item No.7.00 here-in-before but Cross sectional area 95 sq mm, 3.5 core
All as per Sl item No.7.00 here-in-before but Cross sectional area 185 sq mm, 3.5 core
S & F in replacment of street light timer box company made, three phase for 8 KW light load comprising of nature switch, contactor and MCB housed in a enclosure and mounted on angle iron plateform with pcc work on ground complete all as specified and directed by Engineer-in-Charge. Make:- Swadeep/sinetrac
M&L for isolating, disconnecting and transporting the Servo voltage stabilizer of any capacity to workshop for repair maint , strip opening of stabilizer for inspection and ascertaining the defects for repair & replacement of Unserviceable spare parts ,cleaning, servicing all serviceable accessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed by Engr-in-Charge. Note:- spare parts for replacement shall be measured as supply only under respective items of this BOQ and paid seperatly
Supply only PCB controller/Plate for automatic voltage correction suitable for servo stabilizer of capacity 75/60 KVA as per existing type and make complete all as specified and directed by Engr-in-Charge.(make of servo is AE/Volina.)
Supply only control supply transformer suitable for 75/60 KVA servo voltage stabilizer as per existing make and capacity complete all as specified and directed by Engr-in-charge.
Supply only copper dimmer gear set for automatic voltage correction capacity 75/60KVA servo stabilizer with as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
Supply only micro limit switch with cam lever complete for servo stabilizer of capacity 75/60 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
Supply only servo motor synchronous type for automatic voltage correction suitable for servo stabilizer of capacity 75/60 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
Supply only Control Transformer heavy duty sutiable for servo stablizer of 75/60 KVA capacity, complete all as specified and directed by Engr-in-Charge.
Taking down old burnt out copper winding and replacement of same for stabilizer oil immersed type of capacity 75/60KVA by using suitable gauge super enamelled copper conductor as per existing winding complete all as specified and directed by Engr-in-Charge.
Supply of insulation transformer oil toping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV all as specified and directed by Engr-in-Charge.
M&L for boring of road for crossing of size 80 mm dia pipe at suitable depth not lss than 1 mtr by using machinery / equipments complete without damaging the surface for passing pipes / cables etc including removing excavated soil to a distance n exc 50m complete all as specified and as directed. Note : (i) Location for boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer are advised to keep in mind this aspect while quoting rates.
M &L in replacment for 15mm dia GI pipe light grade, for road crossing / on wall / with pole for cable protection including cutting chasing, cutting of plinth protection or wall for inserting of cable and making good disturbed surface with PCC 1:2:4 type B-1 using 20mm graded stone aggregatges complete all as specified and directed
All as per Sl item No 28 above but 40mm dia GI pipe
All as per Sl item No 28 above but 80mm dia GI pipe
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connetced with GI earthing strip of size 32mmx6mm thick by means of brazing between GI strip and earth plate min 45 cm in vertical length and GI strip also to be joined by brazing only. The GI earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layer with tibba sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work and testing complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs GI strip 32mm x 6mm in ground / laid in floor / fixed to walletc complete all as specified and diredcted. Note :- Excavation and earth work shall be measured and paid separately.
Dismantling and taking out the old stay assembly complete including demolition of plain cement all as specified and directed. Note :- (i) Unit rate of this item includes the loose/ disconnect the all accessories which are connected to stay assy including neccessary excavation as directed.
M&L for stay assembly complete with accessories as shown in electrical plate No1 including GI adjustable stay rod of 16 mm dia GI stay wire of size 7/4 mm including stay clamps, loop type insulators etc all as specified and directed. Note :- Earth work and PCC work shall me measured and paid separately.
Supply and replacement of silica gel complete contains in the breather assembly all as specified and directed.
M&L in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for LT, 20x15cm size all as specified and directed.
All as per item No 36 above but for HT, 25 x 20 cm size
M & L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work complete all as specified and as directed by Engineer-in-Charge.
M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint by spray machine including writing MES /SM No(letter size shall be 50 mm size) in capital letters on body for capacity upto 100 KVA transformer outdoor/indoor complete all as specified and directed
All as per item No: 40 but capacity above 160 KVA and upto 630 KVA.
M&L for painting of steel tubular pole 9.0 m long/Swan neck pole, by applying two coat of alluminum paint after scraping/brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white enammelled paint ( 30 cms each) pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
Material and labour for painting with two coats of synthetic enamel paint on RCC pole from 1.5 mtr above the GL and balance 1.5 m from ground level will be painted by synthetic enamel paint in alternatively black and white strap of 30 cm after scraping /removing the existing paint and the preparation on the surface of RCC LT pole. Pole No will be written on pole by black paint in white circle of 150 mm dia complete all as specified and directed.
M & L for cleaning and preparation of surfaces of any existing E/M equipment / LT Panel of any size and applying one coats of synthetic enameled paint complete all as specified and directed
M& L trimming of tree branches on both sides of HT /LT aluminium conductor overhead complete all as specified and directed.Note : (i) Cutting branches shall be dumped outside th Air Force premises . (ii) Contractor shall be provide the ladder of required height including T&P to his worker and nothing extra shall be paid on this account.
S&F in replacment of onload change over switch 630 Amps 4 pole 415 Volts in sheet steel enclouser complete all as specified and directed Make : Havells/L&T/Indoasian.
Taking down/Removing existing damage and bent PCC/Steel poles from site complete all as specified and directed by Engineer-in- Charge.
S&F steel tubular swaged poles type 410 SP-31 (9.00 meter long) complete with CI base plate and finial taper plug, bolts, nuts and screws as specified type including two coats of synthetic enamel paint over a coat of zinc oxide primer complete all as specified and as directed.
Taking down old unserviceable timer switch and checking out complete circuit wiring and replacement of unserviceable spare parts and worn-out circuit wiring and re fixing the same as its original position with making all electrical connections complete all as specified and directed. Note:- Spare parts will be measured in supply only item and paid seperatly
Supply only analoge time switch Front Mounting, 24 hours program, Programmable every 20 min.,back up of100 hrs., current capacity 16A, with 1 changeover (1 CO). Make : Havells /Indoasian
Supply only Din Chanle mounted single module light sensitive switch,230V with outer sensor complete all as specified and directed.Make:-Indoasian/LT/Havells
Supply only 03 pole power contractor MNX 22 type alonwith Aux.Contacts 1NO and 1NC complete all as specified and directed.Make:- Indoasian/LT/Havells
S&F in replacment of Power contactor 63 Amp 4 pole 415 V 50 Hz model MCX 12 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no CS97014 or equivalent
S&F in replacment of MCCB of 800 Amps 4 Pole 415 Volt breaking capacity 50 KA ,FIXED TM type complete connection with proper size of thimbles,nut bolts etc complete all as specified and directed.
M&L for repair of existing AMF DG set panel complete, checking of circuit wiring and replacment of burnt/US spare parts and replacment of burnt circuit wiring and testing at site for smooth functioning of entire system complete all as specified and directed. Note:- spare parts will be measured as supply only and paid seperatly
Supply only contractor ML-6 type with 2NO+2NC cat part No. SS90935 of L&T or equivalent in Havells or Indoasian
Supply only contractor MCX-23 cat part No.CS97018 of L&T or equivalent in Havells or Indoasian
Supply only contractor MCX-22 cat part No.CS97017 of L&T or equivalent in Havells or Indoasian
Supply only TC1D8011 power contractor of C&S make with auxiliary contractor or equivalent in Havells or indoasian
Supply only LC1FDP115A power contractor 115A of C&S make with auxiliary contractor or equivalent in Havells or indoasian
S&F in replacement Onload change over switch 100 Amps,4 pole ,415 V Make:- C&S, Indoasian, L&T
S&F in replacement Onload change over switch 160 Amps,4 pole ,415 V Make:- C&S, Indoasian, L&T
M&L for cleaning of entire cable duct of any size and depth by removing HT/LT cables from the duct , PCC/ iron duct covers removing waste materials including sand , and clean the entire duct and relaying of cables then fillup new sand and cover with existing PCC/Iron duct covers complete all as specified and directed.
M & L for cleaning and preparation of steel surfaces of existing dull painting of rolling shutter and applying two coats of synthetic enamel paint by spray machine complete all as specified and directed
Taking out ruste/ damaged M.S sheet /PCC/RCC duct covers S&F Fe 410-W (Gde-E- 250)quality- A Fe Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk )forming holes, without anyattachment
M&Lfor MS works, cross arms, bracing, support clamps and back plate fabricated out of structural steel sections including nuts, bolts and washers, welding, bending hot or cold, cutting, drilling holes for bolts in any shape or size as directed and including one coat of red oxide primer, one under coat and one finishing coat of aluminium paint paint completet all as specified and directed.
Tracing out fault in 11KV U/G cable with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. Notes: (i). Jointing kit to be measured and paid separately as supply only. (ii) Earth work to be measured and paid separately. (iii). All other necessary arrangements suitable for locating the faults is deemed to be included in the rate quoted. (iv) T & P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account )
Supply only cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core.
All as per item Sl No 68 here in before but Cross sectional area 120 sq mm, 3 core.
Supply, jointing and testing in replacment 11 KV, 3 core cable end termination joint (heat shrinkable) suitable for 3 core ,11 KV /UG 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core.
Supply, jointing and testing in replacment 11 KV, 3 core cable end termination joint (heat shrinkable) suitable for 3 core ,11 KV /UG 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm 3 core.
Dismantling existing ACSR conductor of any size/type from PCC/Steel poles including taking down MS works such as cross arms, clamps, hooks, stay etc from overhead line complete all as specified and directed by Engineer-in-Charge.
Supply, stringing and fixing ACSR conductor of any type/size on existing poles including fixing to insulators with binding wire or aluminium taps complete all as directed .
S&F MCCB 36 KA, 4 pole, 630 Amp in replacement, by removing melted or brunt terminals/ connections of MCCB, 4 pole, 415 Volts, with in existing electric panel and connecting with new connections complete all as specified and directed.
All as per Sl item No 74 above but MCCB 25 KA, 4 pole, 400 Amp
All as per Sl item No 74 above but MCCB 25 KA, 4 pole, 200 Amp
All as per Sl item No 74 above but MCCB 25 KA, 4 pole, 160 Amp
All as per Sl item No 74 above but MCCB 25 KA, 3 pole, 250 Amp
All as per Sl item No 74 above but MCCB 25 KA, 3 pole, 200 Amp
All as per Sl item No 74 above but MCCB 25 KA, 3 pole, 100 Amp
All as per SI item No 74 above but MCCB 16 KA, 3 pole, 63 Amp
M& L for replacement in repair of Supply, install, testing and commissioning LT Panel, Outdoor type, dust and vermin proof, totally enclosed, platform mounted, factory made having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40 mm x 40 mm x 6 mm thick, duly painted all as specified including necessary foundation bolts, PCC (1:2:4), type B-1 platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 400 Amps and shall be complete with internal wiring with copper conductor and including the following accessories(for alternate site):- (A) Main Incoming (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 250 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic setting - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue, Main ON - 01 Set (B) Main Outgoing (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 100 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA, with adjustable thermal and fixed magnetic setting - 02 No. (ii) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 160 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA, with adjustable thermal and fixed magnetic setting - 01 No.
Kular and Company
CHOUDHARY ENTERPRISES
DHALIWAL CO.
S K BANSAL AND CO.
SANGAM ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .