Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAdmitted-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Admitted-Finance | |
| 2 | L2₹37.4 L+₹3.4 L (9.89%)Admitted-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Admitted-Finance | |
| 3 | L3₹39.6 L+₹5.6 L (16.4%)Admitted-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L3 | Admitted-Finance | |
| 4 | L4₹39.9 L+₹5.9 L (17.4%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹39.9 L+₹5.9 L (17.4%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S SITAL BUILDERS L6 | M/S K D TURAIHA L10 | KAKWANI BUILDERS L5 | M/S S.S. Construction L7 | M/s SHARMA BUILDERS & ENGINEERS L8 | PURBANCHAL BUILDERS L2 | M/s B.M. Enterprise L4 | M/S PARKASH ENTERPRISES L1 | Shiva Builders L3 | M/S SEWAK SINGH L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 4 Sqmm section, complete all as specified and as directed by engineer-in-charge. | 400 | RM | 69 ₹27,600 | 60 ₹24,000 | 90 ₹36,000 | 55 ₹22,000 Lowest | 60 ₹24,000 | 89 ₹35,600 | 70 ₹28,000 | 66 ₹26,400 | 130 ₹52,000 | 60 ₹24,000 |
| 2.00 | All as per Item No. 01 here-in-above, but for cross-sectional area 6 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 500 | RM | 89 ₹44,500 | 70 ₹35,000 Lowest | 105 ₹52,500 | 70 ₹35,000 Lowest | 80 ₹40,000 | 99 ₹49,500 | 90 ₹45,000 | 88 ₹44,000 | 140 ₹70,000 | 75 ₹37,500 |
| 3.00 | All as per Item No. 01 here-in-above, but for cross-sectional area 10 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 400 | RM | 139 ₹55,600 | 80 ₹32,000 Lowest | 115 ₹46,000 | 100 ₹40,000 | 100 ₹40,000 | 119 ₹47,600 | 110 ₹44,000 | 111 ₹44,400 | 150 ₹60,000 | 110 ₹44,000 |
| 4.00 | All as per Item No. 01 here-in-above, but for cross-sectional area 16 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 200 | RM | 189 ₹37,800 | 100 ₹20,000 Lowest | 125 ₹25,000 | 130 ₹26,000 | 120 ₹24,000 | 139 ₹27,800 | 120 ₹24,000 | 155 ₹31,000 | 170 ₹34,000 | 160 ₹32,000 |
| 5.00 | Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 240 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including testing and taking out of existing old damaged cable, complete all as specified and as directed by Engineer-in-charge.
NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. | 80 | RM | 2,939 ₹2,35,120 | 1,900 ₹1,52,000 | 2,840 ₹2,27,200 | 2,590 ₹2,07,200 | 2,750 ₹2,20,000 | 1,999 ₹1,59,920 | 2,500 ₹2,00,000 | 1,777 ₹1,42,160 Lowest | 2,359 ₹1,88,720 | 2,700 ₹2,16,000 |
| 6.00 | All as per Item No. 05 here-in-above, but for cross-sectional area 185 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 80 | RM | 2,479 ₹1,98,320 | 1,600 ₹1,28,000 | 2,305 ₹1,84,400 | 2,060 ₹1,64,800 | 2,200 ₹1,76,000 | 1,699 ₹1,35,920 | 2,100 ₹1,68,000 | 1,555 ₹1,24,400 Lowest | 1,835 ₹1,46,800 | 2,200 ₹1,76,000 |
| 7.00 | All as per Item No. 05 here-in-above, but for cross-sectional area 150 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 80 | RM | 1,939 ₹1,55,120 | 1,350 ₹1,08,000 | 1,810 ₹1,44,800 | 1,650 ₹1,32,000 | 1,850 ₹1,48,000 | 1,399 ₹1,11,920 | 1,700 ₹1,36,000 | 1,333 ₹1,06,640 Lowest | 1,550 ₹1,24,000 | 1,800 ₹1,44,000 |
| 8.00 | All as per Item No. 05 here-in-above, but for cross-sectional area 120 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | 1,739 ₹1,73,900 | 1,100 ₹1,10,000 | 1,564 ₹1,56,400 | 1,400 ₹1,40,000 | 1,500 ₹1,50,000 | 1,099 ₹1,09,900 | 1,400 ₹1,40,000 | 888 ₹88,800 Lowest | 1,295 ₹1,29,500 | 1,550 ₹1,55,000 |
| 9.00 | All as per Item No. 05 here-in-above, but for cross-sectional area 95 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | 1,389 ₹1,38,900 | 1,000 ₹1,00,000 | 1,292 ₹1,29,200 | 1,130 ₹1,13,000 | 1,200 ₹1,20,000 | 899 ₹89,900 | 1,100 ₹1,10,000 | 888 ₹88,800 Lowest | 975 ₹97,500 | 1,150 ₹1,15,000 |
| 10.00 | All as per Item No. 05 here-in-above, but for cross-sectional area 70 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | 1,139 ₹1,13,900 | 900 ₹90,000 | 1,082 ₹1,08,200 | 920 ₹92,000 | 1,000 ₹1,00,000 | 699 ₹69,900 | 900 ₹90,000 | 666 ₹66,600 Lowest | 785 ₹78,500 | 850 ₹85,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
25 Aug 2026, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
REPAIR MAINT OF SWITCHGEAR, CORRODED POLE, STREET LIGHT FLOOD LIGHT GARDEN LIGHT AND OTHER CONNECTED WORKS AT TAMULPUR AND DARRANGA MIL STN UNDER GE RANGIA
2026_MES_782656_1
8075/RNG/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
TAMULPUR AND DARRANGA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Rangia
₹1 L
Yes
2 Sept 2026
4 Aug 2026
27 Aug 2026
4 Aug 2026
25 Aug 2026
20 Aug 2026
4 Aug 2026 - 11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 4 Sqmm section, complete all as specified and as directed by engineer-in-charge. | 400 | RM | - | - |
| 2 | All as per Item No. 01 here-in-above, but for cross-sectional area 6 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 500 | RM | - | - |
| 3 | All as per Item No. 01 here-in-above, but for cross-sectional area 10 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 400 | RM | - | - |
| 4 | All as per Item No. 01 here-in-above, but for cross-sectional area 16 Sqmm, complete all as specified and as directed by Engineer-in-charge. | 200 | RM | - | - |
| 5 | Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 240 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including testing and taking out of existing old damaged cable, complete all as specified and as directed by Engineer-in-charge.
NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. | 80 | RM | - | - |
| 6 | All as per Item No. 05 here-in-above, but for cross-sectional area 185 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 80 | RM | - | - |
| 7 | All as per Item No. 05 here-in-above, but for cross-sectional area 150 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 80 | RM | - | - |
| 8 | All as per Item No. 05 here-in-above, but for cross-sectional area 120 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | - | - |
| 9 | All as per Item No. 05 here-in-above, but for cross-sectional area 95 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | - | - |
| 10 | All as per Item No. 05 here-in-above, but for cross-sectional area 70 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. | 100 | RM | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
8075TENDERDOCUMENT.pdf
Tender Documents • 0.40 MB
BOQ_876863.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .