| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-Finance | ₹12.6 L | L1 | Accepted-Finance L1 |
| 2 | L2₹13.6 L+₹99,205.86 (7.89%)Rejected-Finance HNO 1131 TIVIM BARDEZ GOA | TIVIM | BARDEZ | GOA | 403507 | ₹13.6 L+₹99,205.86 (7.89%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Documents not submitted |
Tender Value
₹11.0 L
EMD Value
₹22,046
Closing Date
12 Jun 2026, 5:00 pmClosed
EXECUTIVE ENGINEER, DIVN V, BICHOILM.
EXECUTIVE ENGINEER, DIVN V, BICHOILM.
Tender for the work of enhancement of 150 KVA DTC at Adhar Hospital, Sarvan to 200 KVA, with change of structural material of DTC for A.P.S. to 4 nos. of LTD connections to N. Phadte, S.L. Gauns, and A. Abbigeri, in the juridiction of S. O. Karapur.
2026_ED_29613_1
Tender-17/Div-V (2026-27)
Open Tender
Electrical Works
Percentage
180 days
Sarvan
AS PER NIT SPECIFICATIONS
2 documents required · 2 mandatory
₹500
₹22,046
25 Aug 2026
5 Jun 2026
15 Jun 2026
6 Jun 2026
12 Jun 2026
8 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cost of Material | - | - | - | - |
| 2 | 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A | 1 | Sets | 23,535 | ₹23,535 |
| 3 | 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith. | 1 | Sets | 10,450 | ₹10,450 |
| 4 | 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm | 3 | Sets | 3,033 | ₹9,099 |
| 5 | HDGI structure material for 12 DPS. Each trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel | 260 | Kgs | 169 | ₹43,940 |
| 6 | Supply & Erection of 200KVA 11KV/.4KV Distribution transformer level II Aluminium Winding with Bimetetllic terminal connectors energey effeiecny II as per IS 1180 ( Part-I):2014 | 1 | No | 3,77,405 | ₹3,77,405 |
| 7 | Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole | 4 | Sets | 4,366.54 | ₹17,466.16 |
| 8 | HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524 | 7 | Nos | 1,466.2 | ₹10,263.4 |
| 9 | HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole as per drg No.CEE/E-491 and drg no. CEE/E-524 | 5 | Nos | 926.2 | ₹4,631 |
| 10 | LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig 4 of IS: 7935-1975 as amended upto date comprise fo 2 GI strips, 2 GI bolts and 2 nuts with spring washers. | 24 | Sets | 372 | ₹8,928 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 22.94 MB
BOQ_30038.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .