Loading…
Loading…
Tender Value
₹44.4 L
EMD Value
₹89,000
Closing Date
30 Sept 2026, 6:00 pm
GE (AF) GURGAON
GE (AF) GURGAON
SPECIAL REPAIR TO OLD CI GI AND UPVC WATER PIPE LINE IN TECH AND DOMESTIC AREA OF AF STN ISSAPUR C/O AF STN RAJOKRI AND OTHER 03 EM MINOR WORKS OF AF STN ISSAPUR AND AFS INDAURA UNDER GE (AF) GURGAON
2026_MES_788544_1
GE/GUR-/NIT-87/2026-27
Open Tender
Civil Works
Item Rate
270 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹89,000
9 Sept 2026
9 Sept 2026
3 Oct 2026
9 Sept 2026
30 Sept 2026
23 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface PVC casing caping (ISI marked) with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick for fixing modular type switch and socket including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, the make of cable shall be one of the following M/s Finolex, M/s Havells, M/s Plaza, complete all as specified & directed for light/fan. | 4 | Point | - | - |
| 2 | Supply and fixing ceiling rose PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals | 4 | Each | - | - |
| 3 | M&L for switch modular type single pole one way 6 amps complete all as directed by Engr - in - charge. | 4 | Each | - | - |
| 4 | Supply & fixing Air Circulator fans 230 volts single phase oscillating 450 mm sweep, Metal body , Heavy durty, ISI Marked suitable for wall mounting. | 4 | Each | - | - |
| 5 | M&L for concealed conduit point wiring complete with stranded copper conductor 4 sqmm single core (nominal area ) PVC insulated and unsheathed cable 650 volts grade drawn in and including medium duty concealed in PVC concealed conduit conforming to IS and ISI marked not less than 19 mm dia with 1.6mm thick concealed pressed steel terminal boxes with plate and framecover for rquired module including single core stranded copper conductor 4 sqmm PVC insulated unsheathed cable in same conduit as earth wire to the common earth and connecting to earth dolly all as specified | 4 | Per point | - | - |
| 6Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed . | |||||
| 7 | Supply and fixing drain pipe for AC indoor unit, rigid and flexible type 20mm dia with clamps of suitable size as per site requirement complete all as specified and as directed. | 15 | RM | - | - |
| 8 | Supply , installation, testing and commissioning hi wall split units indoor & outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity -2 Ton capacity complete with all standard accessories, refrigerant and interconnecting cable, mounting arrangements all as specified and as directed.Note - (i) All Tubings shall be of Cu. (ii) AC shall be suitable for outdoor temp of 50 0 C. | 4 | EACH | - | - |
| 9 | Supply , installation, testing and commissionin Voltage stabilizer for automatic operation , single phase naturally air cool indoor type & designed for input variation between 150 volts to 280 volts with output voltage stabilized at 230 volts with accuracy of 2.5% +/- and of capacity of 5 KVA complete with all accessories, mounting arrangement, internal protection, connections and eaerhing complete. | 4 | EACH | - | - |
| 10 | Supply and fixing flame proof ceiling fan 1200 mm sweep, Single phase weather proof IP 65 in die cast aluminium alloy, epoxy powder coated, class F insulation, including regulator and making electrical connections with 4 core class F insulated flexible cable flame proof drawing into flame proof Conduit, complete with making arrangement for fixing of ceiling fan as per site requirement and also making good to disturbed surfaces as per matching the existing complete all as specified and as directed by Engr-in-Charge Make:- Sudhir/ Crompton/Havells/Polycab all as specified and directed | 6 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments87.pdf
Tender Documents • 0.42 MB
BOQ_883882.xls
BOQ • 1.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .