Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-PreQual/Technical 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Not Admitted-PreQual/Technical Others-Rejected due to FDR not Submitted |
| 4 | Not Admitted-PreQual/Technical 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Not Admitted-PreQual/Technical Others-Rejected due to FDR not Submitted |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
1 Jan 2025, 2:30 pmClosed
EX. ENGINEER (E AND M) M-9
D BLOCK OHT OPP DESU COLONY JANAKPURI NEW DELHI-58
Repair and Renovation of internal wiring of various tubewells room under AC-36 Bijwasan.
2024_DJB_267280_5
N.I.T. No.24 (2024-25)/ EE(EnM)M-9
Open Tender
Civil Works
Works
30 days
OFFICE OF THE EX. ENGINEER (E AND M) M-9
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB EMD Ac No. 50448339804
₹9,000
3 Jan 2025
27 Dec 2024
1 Jan 2025
27 Dec 2024
1 Jan 2025
27 Dec 2024
Dismantling of all old wiring, electrical illumination fittings, fans, MCB’s, DB’s, mains, MS/GI boxes, plates, switches, conduits etc. as per site requirement and shifting it to a safer place.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR 2022, 31.3.2
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR 2022,1.32
Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. DSR 2022,1.33
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR 2022 , 31.7.2
2X1.5sq.mm+1 X1.5sq.mm earthwire DSR 2022 31.7.1
Supply of exhaust fan size 450 mm 1400 RPM sweep, Make: Crompton/ Havells / Almonard/ any other DJB approved make.
SITC of 20 W batten LED Light complete with all accessories and tube etc. Directly on ceiling / wall including connection with 1.5 mm FR PVC insulated, copper conductor, single core cable and earthing etc. as reqd. Make: Havells/Bajaj/Crompton / any other approved make of DJB.
SITC of 30 W LED Flood Light complete with all accessories and tube etc. Directly on ceiling / wall including connection with 1.5 mm FR PVC insulated, copper conductor, single core cable and earthing etc. as reqd. Make: Havells/Bajaj/Crompton / any other approved make of DJB.
Ceiling Fan, 5 Star rating 1200 mm blade size with regulator make: Havells, Crompton, Bajaj or any other DJB approved make.
Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. DSR 2022 31.44
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep DSR 2018, 1.50.1
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4 way (4 + 12), Double door. DSR 2018
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. DSR 2018, 2.10.1
cartage and transportation charges for the above work to be executed at site
Testing & Commissioning of complete work in the presence of Engineer-in-charge.
Raj Engineering Co. (BID ID -1556618)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .