| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹5.9 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹6.4 Cr+₹55.5 L (9.45%)Rejected-Finance | ₹6.4 Cr+₹55.5 L (9.45%) | L2 | Rejected-Finance Quoted rate higher than L1 bidder |
| 3 | L3₹6.8 Cr+₹96.3 L (16.4%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹6.8 Cr+₹96.3 L (16.4%) | L3 | Rejected-Finance Quoted rate higher than L1 bidder |
| 4 | L4₹8.7 Cr+₹2.9 Cr (49.0%)Rejected-Finance 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | ₹8.7 Cr+₹2.9 Cr (49.0%) | L4 | Rejected-Finance Quoted rate higher than L1 bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Approved by TSC for the reasons as mentioned on Summary Uploaded |
| Sl No | Description | Qty | Unit | NIRMAL SALES CORPORATION L1 | M P KHAITAN L2 | Omega Elevators L4 | Escon Elevators Pvt Ltd L3 |
|---|---|---|---|---|---|---|---|
| 1.00NOTE (Applicable for all items) :- (i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' | |||||||
| 2.00Dismantling and taking down carefully all electrical and mechanical components, assemblies, sub systems such as drives, machine, control panels, lift car, ropes, guides, counterweights, rails, beams and doors, electrrical wirings, control wiring etc. complete of existing beyond economical repairs (BER) lifts including taking down all steel work and components from machine room, lift shaft, lift pit and stacking neatly all retrieved components deposit to departmental store for safe custody and for persual of BOO and making good the disturbed surface in machine room at all landings and in lift door faces to mactch with existing surfaces, all as directed at site by Engr in charge for the following lifts :( Making good to disturbed surfaces is deemed to be included in the unit rate quoted. | |||||||
| 3.00 | Dismantling of the old 13 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard complete all as specified and directed(Bldg- Hooghly View) | 1 | Each | 54,600 ₹54,600 Lowest | 90,000 ₹90,000 | 1,18,000 ₹1,18,000 | 1,95,000 ₹1,95,000 |
| 4.00 | Dismantling of the old 10 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard complete all as specified and directed(Bldg T V -16) | 1 | Each | 54,600 ₹54,600 Lowest | 95,000 ₹95,000 | 1,18,000 ₹1,18,000 | 1,95,000 ₹1,95,000 |
| 5.00 | Dismantling of the old 13 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg- P-197 & 198 BMC) | 2 | Each | 46,200 ₹92,400 Lowest | 90,000 ₹1,80,000 | 1,18,000 ₹2,36,000 | 1,65,000 ₹3,30,000 |
| 6.00 | Dismantling of the old 08 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg no P-197-02, P-198-02 (BMC), Map A-01, Map B -01(Vijay Durg) | 6 | Each | 46,200 ₹2,77,200 Lowest | 90,000 ₹5,40,000 | 1,18,000 ₹7,08,000 | 1,65,000 ₹9,90,000 |
| 7.00 | Dismantling of the old 06 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No TV-18) | 1 | Each | 46,200 ₹46,200 Lowest | 85,000 ₹85,000 | 1,18,000 ₹1,18,000 | 1,65,000 ₹1,65,000 |
| 8.00 | Dismantling of the old 08 passenger lift machine ( G+9) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No- JSA I & II , Vijay Durg) | 2 | Each | 42,000 ₹84,000 Lowest | 80,000 ₹1,60,000 | 1,18,000 ₹2,36,000 | 1,50,000 ₹3,00,000 |
| 9.00 | Dismantling of the old 8 passenger lift machine ( G+7) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg - P-173 BMC) | 1 | Each | 33,600 ₹33,600 Lowest | 75,000 ₹75,000 | 1,18,000 ₹1,18,000 | 80,000 ₹80,000 |
| 10.00 | Dismantling of the old 13 passenger lift machine ( G+6) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - P-127 (BMC) | 1 | Each | 29,400 ₹29,400 Lowest | 85,000 ₹85,000 | 88,500 ₹88,500 | 70,000 ₹70,000 |
Tender Value
₹8.3 Cr
EMD Value
₹7.4 L
Closing Date
27 Sept 2025, 6:00 pmClosed
Shri Somesh Kumar IDSE CE
HQ Chief Engineer Kolkata Zone Military Engineer Services Ballygunge Maidan Camp Gurusaday Road Kolkata 700019
REPAIR REPLACEMENT OF BER LIFTS IN KOLKATA MIL STN
2025_MES_726702_1
89107/E8
Open Tender
Miscellaneous Works
Item Rate
540 days
Alipore Hastings Fort William
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (CENTRAL) KOLKATA
₹7.4 L
Yes
28 Nov 2025
19 Aug 2025
4 Oct 2025
19 Aug 2025
27 Sept 2025
10 Sept 2025
Amount
NOTE (Applicable for all items) :- (i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A'
Dismantling and taking down carefully all electrical and mechanical components, assemblies, sub systems such as drives, machine, control panels, lift car, ropes, guides, counterweights, rails, beams and doors, electrrical wirings, control wiring etc. complete of existing beyond economical repairs (BER) lifts including taking down all steel work and components from machine room, lift shaft, lift pit and stacking neatly all retrieved components deposit to departmental store for safe custody and for persual of BOO and making good the disturbed surface in machine room at all landings and in lift door faces to mactch with existing surfaces, all as directed at site by Engr in charge for the following lifts :( Making good to disturbed surfaces is deemed to be included in the unit rate quoted.
Dismantling of the old 13 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard complete all as specified and directed(Bldg- Hooghly View)
Dismantling of the old 10 passenger lift machine ( G+12) and all connected accessories and depositing in the mes store yard complete all as specified and directed(Bldg T V -16)
Dismantling of the old 13 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg- P-197 & 198 BMC)
Dismantling of the old 08 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg no P-197-02, P-198-02 (BMC), Map A-01, Map B -01(Vijay Durg)
Dismantling of the old 06 passenger lift machine ( G+10) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No TV-18)
Dismantling of the old 08 passenger lift machine ( G+9) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No- JSA I & II , Vijay Durg)
Dismantling of the old 8 passenger lift machine ( G+7) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg - P-173 BMC)
Dismantling of the old 13 passenger lift machine ( G+6) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - P-127 (BMC)
Dismantling of the old 8 passenger lift machine ( G+6) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - Map C (Vijay Durg), T V - 15)
Dismantling of the old 6 passenger lift machine ( G+5) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - TV 13 and TV-14)
Dismantling of the old 8 passenger lift machine ( G+5) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - P-1 (Vijay Durg)
Dismantling of the old 6 passenger lift machine ( G+4) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - O-32 IGS)
Dismantling of the old 8 passenger lift machine ( G+2) and all connected accessories and depositing in the mes store yard complete all as specified and directed (Bldg No - MES IB (Vijay Durg)
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below complete all as specified and directed:- (Location of lift :Hoogly View) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 13 Passenger, 884 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+12 floor (h) Serving : G+ 12 upper floors- (13 Stops, 13 landings, 13 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10,11,12 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door)),Battery operated emergency light & alarm complete all as specified for 10 passenger as per the details given below complete all as specified and directed:- (Location of lift :TV 16) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 10 Passenger, 680 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+12 floor (h) Serving : G+ 12 upper floors- (13 Stops, 13 landings, 13 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10,11,12 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below complete all as specified and directed:- (Location of lift :P197-1BMC, P198-1 BMC) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 13 Passenger, 884 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+10 floor (h) Serving : G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed:- (Location of lift :P197-2 BMC, P198-2 BMC, MAP A-1 VD, MAP B-1 VD) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+10 floor (h) Serving : G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given below complete all as specified and directed:- (Location of lift :TV18 ALIPORE) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 6 Passenger, 408 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+10 floor (h) Serving : G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+9 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door)),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed:- (Location of lift :JSA ENCLAVE BLOCK1 AND BLOCK 2- 02 NOS) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+9 floor (h) Serving : G+ 9 upper floors- (10 Stops, 10 landings, 10 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+7 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door)),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed:- (Location of lift :P173 BMC-01) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+7 floor (h) Serving : G+ 7 upper floors- (8 Stops, 8 landings, 8 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door)),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below complete all as specified and directed:- (Location of lift :P127 BMC-01) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 13 Passenger, 884 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+6 floor (h) Serving : G+ 6 upper floors- (7 Stops, 7 landings, 7 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed:- (Location of lift :MAPC VD-01, TV15 ALIPORE -01) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+6 floor (h) Serving : G+ 6 upper floors- (7 Stops, 7 landings, 7 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+5 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door)Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed:- (Location of lift :P/1 VD-03 NOS) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+5 floor (h) Serving : G+ 5 upper floors- (6 Stops, 6 landings, 6 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+4 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given below complete all as specified and directed:- (Location of lift :O32 IGS- 01) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 6 Passenger, 408 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+4 floor (h) Serving : G+ 4 upper floors- (5 Stops, 5 landings, 5 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+5 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door)),Battery operated emergency light & alarm complete all as specified for 6 passenger as per the details given below complete all as specified and directed:- (Location of lift :TV13 ALIPORE-01, TV14 ALIPORE-01) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(a) Type & capacity : 6 Passenger, 408 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VVVF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+5 floor (h) Serving : G+ 5 upper floors- (6 Stops, 6 landings, 6 openings) (j) Existing Well size : As existing at site (as per Appx `A' attached)
(k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665.
(l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage. (n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The cost of earthing and connected items shall be paid separaty under respective item of work in schedule. (p) Car Enclosure : Stainless Steel (Hairline) mirror finish body of car having minimum thickness of SS Sheet as 1.5 mm incl recessed LED light, false ceiling, as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code of latest edition.. (r) Flooring : 18-20mm thick granite flooring. (s) No of Entrance : One location - Front.
(t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4, 5 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs (y) Roping : Lift rope shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure.
(ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke illuminated push buttons shall be provided. (ah) All landing door shall be one hour fire rated. (aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror finished stainless steel (1.5mm) panel to be provided on all side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted illuminated buttons in Stainless steel (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button.
(ar) Hall fixtures face plate : Stainless steel (Hairline). (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off.ON/OFF system to be synchronised with car door opening/closing system. (au) Machine room ladder , where applicable should be provided by the contractor (av) Hoist way wiring, where required shall be provided by the contractor (av) Ventilation : High powered axial flow fan with suitable air throw of 600 CFM through a duct all around the car so that uniform air flow shall be available at all side of the car.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+2 upper floors with AC Variable Voltage Variable Frequency (VVVF) Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system ( 01 Nos without hand set in car , (02 Nos with hand set in Machine room & near ground (floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed:- (Location of lift :MES IB VD-01) Note : - The under mentioned scope of work for B/R & E/M works related and any other works required with installation of lift for entire completion and its smooth function is demmed to be included in the unit rate quoted by the contractor :- (i) Preparation of shaft (including structural repair wherever needed by standard practice using polymer modified mortor / microconcrete after rust remover and anti rust coating. (ii) Complete wiring with and including conduit pipe , replacement and installation of load hook, and slab cutting wherever required.
(iii) Shaft pit preparation to host the lift including its water proofing and required concreting to make requisite level of base. (iv) Work related to door facia & lintel preparation and granite finish in all 3 facia of door at all floor. (v) Padestal preperation at machine room. (vi) Requisite shaft lighting with 5 Pin 6A socket at every landing, Pit light with 1 No , 5 Pin 6A socket with switch. (vii) Lift must conform to standards of latest IS 17900 if its implemented since Dec 2025.
(l) Hoist way dimnsions : 2100mm wide x 1200 mm deep (m) Car travel : 9000mm (n) Overhead : 5400mm (o) Pit depth : 2380mm (p) Car dimensions : 1100 mm wide x 1400 mm deep (q) Door opening : 800 mm wide x 2000 mm high
® Car door : 2 panel automatic centre opening with full glass with ACVF drive in stainless steel hairline finish. (s) Landing door : 2 panel automatic center opening with full glass door in hairline finish on all floor. (t) Car design : Car walls in stainless steel hairline with rear side glass fibish ( minimum thickness of the glass is 8 mm) sandwitch type toughned glass. (u) Car suspended ceiling : Hairline stainless tseel finish with stralight LED for lighting (v) Car flooring : 20mm recess for granite flooring (customer) (w) Natural mirror in car : NA (x) Handrail : Round handrail in hairline stainless steel finish provided on rear wall of car. (y) Car operating panel : Half heoght - flush mounte (z) Landing operating panel : Individual landing operating panel for the elevator.
Features Included :- (aa) Alarm button in car operating pannel with battery backup. (ab) automatic operating for car fan (ac) Adjustable door open time (ad) Anti nuisance (empty car) (ae) Anti nuisance ( car call cancellation at direction reversal) (af) Blower fan in car fro ventilation (ag) Braille on push button (ah) Car call cancellation by double pressing floor button in car operating panel (aj) Door open and door close buttons in car operating panel (ak) Door closing retries : door Nudging (al) Emergency light, Home landing (am) Full load by-pass (an) Infra -red screen for car door (ao) 2 way intercom, attendant control (ap) Jammed landing operating panel call button by-pass (aq) Motor overhead protection (ar) Overload function with audio- visual indication in car operating panel
(as) Phase failure and phase reversal protection (at) automatic rescue devise in case of power failure (au) Voice announcement unit in English language in car (av) Red dot matrix display in car operating panel. (aw) Red dot matrix display in landing operating panel on all floors (ax) Fireman control, firman emergency return. (ay) pit ladder
NOTES FOR ITEM NO 16.00 TO 28.06 (i) The system (Lift) shall be guaranteed against manitenance and repir including spares for a period of Two years from the certified date of completion of this contract and the cost of these lifts shall be deemed to be included in the unit rates quoted against the lifts. The lump sum cost of above lift shall be deemed to include cost of comprehensive maintenance if defect liability period of all the lifts provided by the contractor under this contract for a period of two year from the certified date of completion of the work. Fot this a sum of Rs. 4,00,000.00 (Rupees Four Lakh only) shall be retained from the final bill of this contract till satisfactory completion of said comprehensive maintenance period of lifts as certified by the GE. The amount so retained shall be released by the GE after expiry of satisfactory comprehensive manitenance in defect liability period. (ii) The bidder / tenderer be advised to visit existing lifts, lift well, machine room at site, before quoting his offer and nothing will be paid on this account. Irrespective of of the fact if the bidder has visited the site or not, it shall be assumed that he has visited the site and nothing extra shall be payable on account of any variation in site conditions than those specified in tender. (iii) The quoted rate shall deemed to include the cost of minor civil works, MS Beams, MS rail with fixing arrangement including making good to the disturbed surface to match with the existing. (iv) The lifts shall comprise of all latest safety measures as specified in relevent IS Codes ( IS-14665 of 2015 : Part-I, IS-14665 of 2009 : Part V, IS-4591 of 2012, IS-15785 of 2007) and National Building Code-2016 Section-5 Part-8 as revised from time to time. (v) The wiring of lift shall be with copper conductor, stranded, ISI marked of suitable size. The wiring in the lift well shall be in MS conduit, ISI marked medium grade of suitable size. Suitable sockets / lights shall be provided as directed in the lift shaft.
vi) If anything missed above but is techncally required for efficient working of the lift is deemed to be included in the quoted rate. (vii) Instruction shall be provided by the manufacturer inside amd outside the car. The instructions shall be written on a metallic sheet with embossed letters matching eith car decor / outside decor all as directed. (viii) A board depicting manual rescue procedure to be provided at location as directed. (ix) The comprehensive manitenance of lift shall be executed through OEMs or their accredited / authorized agencies. (x) The contractor shall MOU with the OEMs or their accredited / authorized agencies for comprehensive maintenance of defect liability period after one month of date of commencement. (xi) The quoted rate is deemed to include the above provision as specified above. (xii) After errection of lift it must be tested from State Govt licence Insoector or their authorised vendors. (xiii) In case of any specific capacity of passenger are not manufactured by the any above OEM, the contractor shall provide nearby higher capacity of passenger by OEM without any extra cost to the department. (xiv) GA drawing shall be submitted by the contractor prior to execution of work for approval of respective GE`s. (xv) In the above description, if anything is left out it is mandatory requirement to comply relevent IS/NBCs directive or anything more provided by the OEM for better performance of the lift, which may be provided to be included in the cost for extra items shall deemed to be included in the unit cost quoted.No extra payment shall be allowed on this ground letter on.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtrdeep below ground level with top edge of the plate notless than 1.5 m below ground level connetced withgalvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on porcelain insulator or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for wall/ roof etc. as required by 25X4mm galvanised iron strip complete all as specified and directed.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 3.5 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and fixing MCB TPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed.
Supply and fixing MCB , TPN type `C' ,40 Amps 415 Volts FP with rapturing capacity 10KA including taking down of old one complete all as specified.
Supply and fixing MCB, type C, 10 KA 240 Volts 5 to 32 amps single pole complete all as specified.
Supply and fixing MCB DP 40 to 63 amps 240 volts 10KA, type C breaking capacity complete all as specified.
M P KHAITAN (BID ID -3429822)
Escon Elevators Pvt Ltd (BID ID -3430660)
Omega Elevators (BID ID -3430316)
Bidder Name
NIRMAL SALES CORPORATION
Escon Elevators Pvt Ltd
M P KHAITAN
Omega Elevators
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TENDERDOCUMENTS89107.pdf
Tender Documents • 1.46 MB
BOQ_813503.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .