Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical As per NIT/ SBD Conditions |
Tender Value
₹38.6 L
EMD Value
₹77,300
Closing Date
12 Oct 2019, 12:00 pmClosed
Er. Bikram Singh
XEN PWD Const Div. No.III Jammu
BOQ
2019_PWDJK_81299_1
Bid No. 45 of 2019-20 Dt.06-09-2019
Open Tender
Civil Works
Item Rate
270 days
Makwal
SBD
4 documents required · 4 mandatory
₹1,000
Yes
Executive Engineer PWD Const Div. No.III
₹77,300
Yes
Jammu
1 Jan 2020
7 Sept 2019
12 Oct 2019
7 Sept 2019
12 Oct 2019
16 Sept 2019
16 Sept 2019
Amount
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead: 1:3:6 or richer mix . (SSR 2012 Code No.15.2.1)
Demolishing R.C.C work manually/by mechanical means including stracking of steel bars and disposal of unserviceable material within 50 metres lead. (SSR 2012 Code No.15.3)
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disopsal of unserviceable material within 50 metres lead: in cement mortar. (SSR 2012 Code No.15.7.4
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) from brick work in cement mortar. (SSR 2012 Code No.15.8.3)
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: of area beyond 3 sq. metres (SSR 2012 Code No.15.13.2)
Demolishing mud phaska in terracing and disposal of material within 50 metres lead (SSR 2012 Code No.15.27)
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (SSR 2012 Code No.15.26)
Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 2.8).
Providing & laying in Position cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded crushed stone aggregate 40mm excluding the cost of centering and shuttering. All works upto plinth level. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.5.10).
Providing & laying in Position cement concrete 1:4:8 (1 cement : 4 fine sand : 8 graded crushed stone aggregate 40mm excluding the cost of centering and shuttering. All works upto plinth level. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.5.9).
Providing and laying in position cement concrete of 1:3:6 grade (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) excluding the cost of centering and shuttering. All work upto plinth level.(Refer J&K Sanctioned Schedule of Rates 2012, Item code 4.5.5).
Providing and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement. All work up to plinth level using crushed aggregate.(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.1.2).
Providing and laying Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) in suspended floors, balconies, landings and staircases having 15 degree slope. upto floor five level excluding the cost of centering and shuttering. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.50)
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars.(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.22.7).
Centering and shuttering including strutting, propping etc. and removal of form work for :-
Foundations, footings, bases of columns.(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.1)
Lintels, beams, plinth beams, girders, bressumers and cantilevers. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.5)
Columns, pillars, piers, abutments, posts and struts. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.6)
Suspended floors, roofs, landings, balconies and access platforms.(Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.3).
Edges of slabs and breaks in floors and walls upto 20cm wide. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 5.9.16.1).
40mm thick Cement concrete flooring 1:2:4 finished with a floating coat of neat cement slurry, but excluding the cost of nosing of steps etc.complete.(SSR 2012 Code No.11.4.2)
Brick work in 1:4 c/s mortar in foundation and plinth of class designation 75..(SSR 2012 Code No.6.1.7)
Brick work in 1:6 c/s mortar in foundation and plinth of class designation 75..(SSR 2012 Code No.6.1.8)
Extra for brick work in superstructure above plinth level upto floor V level..(SSR 2012 Code No.6.2)
Half brick masonry in 1:4 with bricks of class designation 75 in foundation..(SSR 2012 Code No.6.14.2)
12mm cement plaster of mix 1:6..(SSR 2012 Code No.13.1.2)
12mm cement plaster of mix 1:4.(SSR 2012 Code No.13.7.2)
15mm cement plaster of mix 1:4..(SSR 2012 Code No.13.4.1)
15mm cement plaster of mix 1:6 .(SSR 2012 Code No.13.2.2
6mm cement plaster to ceiling of mix 1:3..(SSR 2012 Code No.13.17)
P/F M.S grills of required pattern in frames of windows,railings etc.with M.S flat,square or round bars etc. incl.priming coat with approved steel primer all complete job fixed to openings/wooden frames with rawl plugs screws etc..(SSR 2012 Code No.9.43)
Supply and filling in plinth with fine sand under floors incl.watering,consolidation etc. complete..(SSR 2012 Code No.2.22)
Supply and filling of brick agg. Under floor incl.compacting the same manually incl.all leads & lifts complete..(SSR 2012 Code No.5.49)
50mm thick Cement concrete flooring 1:2:4 finished with a floating coat of neat cement slurry, but excluding the cost of nosing of steps etc.complete(SSR 2012 Code No.11.4.3)
P/F glass strips in joints of terrazzo/cement concrete flooring 40mm wide and 4mm thick.(SSR 2012 Code No.11.18.1)
Making Plinth Protection 50mm thick of C.Conc.1:3:6 over 75mm bed of dry brick ballast 40mm nominal size well rammed & grouted with fine sand & finished the top smooth with crushed aggregate..(SSR 2012 Code No.4.22)
Painting top of roofs with bitumen of approved quality with a coat of clean sand incl.cleaning the slab surface with brushes & finally with a piece of cloth soaked in kerosene oil complete..(SSR 2012 Code No.12.17)
10mm thick mud phaska of damped brick earth on roofs laid to slope consolidated & plastered with 25mm thick mud mortar mixed with bhusa & covered with flat brick tiles & grouted with C.M 1:3 mixed with 2% of internal water proofing compound etc.complete..(SSR 2012 Code No.12.26)
Providing gola 75 x 75mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75 x 75 mm deep chase with all leads, lift and carriage from source to site complete.(Refer J&K Sanctioned Schedule of Rates 2012, Item code 12.30).
Making khurras 45 x 45cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet with all leads, lift and carriage from source to site complete. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 12.31).
P/F on wall face unplastisized Rigid PVC rain water pipes Type A incl. jointing with seal ring leaving gap for thermal expansion single socketed pipes 110mm diameter..(SSR 2012 Code No.12.57.2)
P/F on wall face unplastisized Rigid Bend Type A incl. jointing with seal ring leaving gap for thermal expansion single socketed pipes 110mm diameter..(SSR 2012 Code No.12.58)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in laye3rs not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering, lead upto 50 Mt. and lift upto 1.50 M as per directions of Engineer-in-charge. (Refer J&K sanctioned Schedule of Rates 2012 item code 2.12)
Steel work welded in built-up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladders, railings, brackets, gates and similar work. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 10.32.2).
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) sal wood.(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.1.7).
Providing 40x5mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).(Refer J&K Sanctioned Schedule of Rates 2012, Item code 9.48).
P/F 35mm thick factory made laminated veneer door shutters incl. M.S pressed butt hinges bright finished required size with necessary screws and paneling with panels of 12mm thick one side prelaminated particle board grade-I medium density flat pressed three layer particle board or wood particle board bonded with BWP type synthetic resin adhesive and prelamination Type-II marked..(SSR 2012 Code No.9.4.A.3)
P/F 25mm thick cupboard shutters with prelaminated flat pressed three layer particle board or graded wood particle board having one side decorative lamination & other side balancing lamination incl.2nd class teak wood lipping if 25mm widex12mm thick with necessary screws & stainless steel piano hinges etc. complete..(SSR 2012 Code No.9.134)
P/F 30mm thick of 2nd class deodar wood glazed shutter for doors,windows etc. using 10kg/sqm float glass panes incl. M.S butt hinges of required size with necessary screws etc.complete. .(SSR 2012 Code No.9.6.3)
Providing and applying white cement based putty of approved brand over the plastered wall surface to prepare the surface even and smooth complete..(SSR 2012 Code No.13.101)
Finishing walls with textured exterior paint of required shade on new work incl.base course of water proofing cement paint..(SSR 2012 Code No.13.89)
Distempering with oil bound washable distemper of approved brand and shade on new work over and including priming coat with cement primer.(SSR 2012 Code No.13.52.1)
Applying priming coat with ready mixed pink or grey primer of approved brand and manuf.acture on wood work..(SSR 2012 Code No.13.56.1)
Painting with synthetic enamel paint of approved brand and shade on new steel work(SSR 2012 Code No.13.57.1)
Painting with synthetic enamel paint of approved brand and shade two or more coats on new work(SSR 2012 Code No.13.69)
P/F ISI marked oxdised M.S sliding door bolts with nuts and screws etc.complete 250x16mm.(SSR 2012 Code No.9.57.2)
P/F Aluminium handles ISI marked of superior make transparent or dyed of required colour and shade with necessary screws etc.complete.
100mm(SSR 2012 Code No.9.99.2)
125mm(SSR 2012 Code No.9.99.1)
P/F Aluminium Tower bolts ISI marked of superior make transparent or dyed of required colour and shade with necessary screws etc.complete.
100mmx10mm(SSR 2012 Code No.9.96.5)
200x10mm(SSR 2012 Code No.9.96.3)
P/F on terrace polyethylene water storage tank with cover & suitable locking arrangements & making necessary holes for inlet,outlet & overflow pipes but without fittings & the bases support for tank.(SSR 2012 Code No.20.40)
Concealed pipe incl.painting with anti-corrosive bitumastic paint ,cutting chases and making good the wall.
15mm dia.nominal bore(SSR 2012 Code No.20.2A.1)
20mm dia.nominal bore(SSR 2012 Code No.20.2A.2)
P/F G.I pipes complete with G.I fittings incl.trenching refilling etc.(External Work)25mm dia.nominal bore. (SSR 2012 Code No.20.3.3)
P/F G.I pipes complete with G.I fittings incl.cutting & making good the walls etc
15mm dia.nominal bore medium(SSR 2012 Code No.20.2.1.1)
20mm dia.nominal bore medium(SSR 2012 Code No.20.2.1.2)
P/L non-pressure NP2 class RCC pipe of dia 10mm with collars jointed off with stiff mixture of cement mortar of mix 1:2.(SSR 2012 Code No.21.6.1)
P/F water closet squatting pan(Indian type W.C pan of size 580x440mm with intergral type foot rest) with 100mm sand cast iron P or S trap,10 litre low level white PVC flushing cistern,incl.flush pipe with manually controlled device with all fittings complete incl cutting & making good the walls & floors etc.complete.(SSR 2012 Code No.19.1.2)
P/F white vitreous china pedestal type water closet (European type) with seat and lid ,10 litre low level white vitreous china flushing cistern & CP flush bend,overflow arrangements and mosquito proof coupling incl. painting of fittings & brackets,cutting & making good the walls & floors along with white china vitreous flushing cistern & C.P flush bend.(SSR 2012 Code No.19.3.1)
P/F wash basin of size 550x400mm with C.I/M.S brackets,15mm C.P brass pillar taps,32mm C.P brass waste of standard pattern incl.painting of fittings & brackets,cutting & making good the walls etc. complete.(SSR 2012 Code No.19.7.4)
P/F C.P brass bib cock of 15mm nominal bore etc.complete.(SSR 2012 Code No.20.41)
P/F C.P brass angle valve for basin mixer & geyser points of 15mm nominal bore etc.complete.(SSR 2012 Code No.20.45)
P/F PVC waste pipe for sink or wash basin incl. PVC waste fitting complete 32mm dia.flexible pipe.(SSR 2012 Code No.19.28.2.1)
P/F 100mm sand cast iron grating for gully,floor or nahani trap.(SSR 2012 Code No.19.29)
P/F Mirror of superior glass of required size & rectangular shape 453x357mm outer dimension with 6mm thick hard board backing with plastic moulded frame of approved make.(SSR 2012 Code No.19.32.2)
Constructing masonry chamber 30x30x50cm inside with brick work in C.M 1:5 for stop cock with C.I surface box 100x100x75mm with hinged cover fix in C.conc.slab 1:2:4 mix necessary excavation,bed in 1:5:10 mix & inside plastering with C.M 1:3 with 12mm thick finishing with a floating coat of neat cement slurry etc. complete.(SSR 2012 Code No.20.24.1)
P/L Ist quality ceramic glazed tiles of approved brand 5mm thick in all colours over 12mm thick bed of C.M 1:3 & grouting the joints with matching pigment etc. (SSR 2012 Code No.11.66)
P/L Vitrified floor tiles 60x60cm thick of approved brand & in all colours & shades over 20mm thick bed of C.M 1:4 & grouting the joints with matching pigment etc. complete.(SSR 2012 Code No.11.34.2)
P/F in position precast RCC manholes cover & frame of required shape & approved quality circular shape 560mm internal dia.complete.(SSR 2012 Code No.21.19.3.1)
Making soak pit 2.5m dia.3.0m deep with 45x45cm dry brick honeycomb shaft with bricks & SW drain pipe 100mm dia.1.8m long complete.(SSR 2012 Code No.21.34)
Carriage of material by Mechanical Transport including loading, unloading and stacking at site
Stone aggrigate upto 40 mm nominal size for an average distance of 05 Km
Sand for an average distance of 08 Km
Bricks for an average distance of 08 Km
Brick tiles for an average distance of 08 Km
Electrical Works :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Refer CPWD DSR E&M 2016 Item No. 1.10.1).
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (Refer CPWD DSR E&M 2016 Item No. 1.12).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Refer CPWD DSR E&M 2016 Item No. 1.14).
2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire (1.14.1).
2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire (1.14.2).
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (CPWD DSR E&M 2016 Item No. 1.17)
1x 2.5 Sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. (for service line). (CPWD DSR E&M 2016 Item No. 1.21)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (CPWD DSR E&M 2016 Item No. 2.4)
4 way (4 + 12), Double door
8 way Double door
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (CPWD DSR E&M 2016 Item No. 1.24)
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (CPWD DSR E&M 2016 Item No. 1.25)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required(CPWD DSR E&M 2016 Item No. 1.26).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (CPWD DSR E&M 2016 Item No. 1.32)
Supplying and fixing of following rating, 240/10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (CPWD DSR E&M 2016 Item No. 2.10)
Single Pole 6/16 amp.
Single Pole and Neutral
Installation testing and commissioning of wall bracket/ceiling fitting of all sizes and shapes contating upto two gls/cfl/led lamp per fitting complete with all accessories including connections etc. as required. (CPWD DSR E&M 2016 Item No. 1.35)
Installation of exhaust fan in the existing opening including making good the damage,connection,testing,commissioning etc.as required.(CPWD DSR E&M 2016 Item No. 1.50 Upto 450mm
Earthing with GI earth pipe 4.5 meter long 40 mm dia including accessories and providing measonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. (CPWD DSR E&M 2016 Item No. 5.20)
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required. (CPWD DSR E&M 2016 Item No. 5.18)
Installation testing and commissioning of prewired flourescent fitting/compact flourescent fitting of all type complete with all accessories and tube/lamp etc. directly on ceiling/wall including connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. (CPWD DSR E&M 2016 Item No. 1.41
Installation testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable including providing and fixing of phenolic laminated sheet cover on the fan box etc. as required. (CPWD DSR E&M 2016 Item No. 1.45)
Earthing with copper earth plate 600mm x 600mm x 3mm including accessories and providing measonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal/coke and salt as required.(CPWD DSR E&M 2016 Item No. 5.6)
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required. (CPWD DSR E&M 2016 Item No.5.19)
Supplying & fixing of Angle/Batten holder polycarbonate including making complete connections etc.as required.(CPWD DSR E&M 2016 Item No.1.58)
Supplying and fixing of 9 watt LED Lamp.(Refer Analysis of rate annexure Item No.13)
Supplying and fixing of following rating, 240/10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Refer Analysis of rate annexure Item No.15)
Single Pole and Neutral 63 amp.
Supplying of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. Warranty two years from the date of installation
Ceiling Fan 1400 mm Sweep 5 Star rating. ( Item No. 6).
LED Ceiling light 12 watt (Item No. 4)
LED Ceiling light 6 watt (Item No. 3)
Bulk Head fitting suitable for out door use (Item No. 2)
Exhaust Fan 300mm(Heavy Duty) Item No.07)
1200 mm size 18/20 watt LED Batten Tube Light fitting.
Supplying and fixing of main service line 6 sqmm twin core aluminium cable unarmoured from the LT pole upto the MCB DB incluiding connections etc. as required.(Refer Analysis of rate annexure Item No.10)
Supplying and fixing of main service line 16 sqmm twin core aluminium cable unarmoured from the LT pole upto the MCB DB incluiding connections etc. as required. (Refer Analysis of rate annexure Item No.11)
Supplying and fixing of 15watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall etc as required. (Refer Analysis of rate annexure Item No.9)
Supplying and fixing of 30 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall etc as required. (Refer Analysis of rate annexure Item No.8)
Fire Fighting System ABC Type Multi-purpose based Fire Extinguisher (ISO 9001) CE Marked applicable on all classes of fire (Capacity 6 Kgs).
CO2 based Fire Extinguisher (ISO 9001) CE Marked applicable on sensitive equipments (e.g. Electrical) Capacity 4.50 Kgs.
Fire Bucket (4 Nos.) with stand.
Soil invesigation by way of Plate Load Test (As directed by the Engineer).
Structural Design & prepartion of drawings (As directed by Engineer). @0.5% of Buildings/Toilets/Kitchen Costs
Providing BALA (Building As Learning Aid) provisions as per drawing enlosed , including preparation of specific BaLA drawings as per the directions of the Engineer
Env. Management Plan
Providing 2 mt. high corrugated GI sheet (min. thickness 0.63 mm) barricading fixed with GI hooks and nuts on frame made of MS pipes having diameter not less than 40 mm. Spacing of vertical pipes shall not be less than 3 m (average) and minimum two horizontal pipes shall be provided. Rate shall be inclusive of cost of providing all materials and fixing arrangements, including excavation, transportion to site, fixing, backfilling, removal of the complete barricading after construction work is over and rehabilitation of the site etc., with all incidental charges, leads, lifts and all taxes and duties as applicable and as specified by Engineer-in-charge. Material of barricading shall be the property of contractor after completion the work. Barricading shall be maintained throughout the construction period. It should be installed in a manner so that one cannot crawl underneath it, should be sturdy enough to bear normal wear and tear at the construction site, should not topple off and hurt someone and should be strong enough to withstand the elements, including high wind conditions. Should be erected between existing building blocks and proposed structures and along the access roads.
Provision, installation and maintenance of cautionary/warning signage, including diversion boards as per IRC specifications (SP:55, 2014) on the main road and along the access, including cost of boards and other materials required for fixing, with all incidental charges leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge.
Cost towards first aid and emergency response arrangements in the camp and worksite (including fire and electrical safety provisions)
Cost towards periodic health check-ups once in three months for all construction workers
Provision for Workers Providing of 2 number of mobile toilets 1 wet type and 1 dry type (bio-digester)
Wet type portable toilet (MS fabricated) 2 seats (1 for men and 1 for women with separate entrances), fitted with 2000 liters capacity overhead tank and 500 liters capacity bottom tank, fitted with Indian type of pot with other facilities such as tap, lighting and ventilation; and sludge tank of capacity 1000L, and stationed at a suitable place in or around 50 metres from work front. Includes cost of water, cost for emptying of bottom tank through mobile suction machine, attendent cost for looking after cleaning and operation of the toilets, all materials and labour charges, all incidental charges, leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge.
Dry type portable toilet (MS fabricated) (bio digestor) of approved design with 2 seats (one for men and one for women). Includes cost of water, cost for emptying of bottom tank through mobile suction machine, attendant cost for looking after cleaning and operation of the toilets, all materials and labour charges, all incidental charges, leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge.)
Providing of mobile drinking water counter/kiosk, fabricated from stainless steel with 300 liters capacity, with two taps and with bottom tank (300 litre holding capacity) to collect waste water and stationed at a suitable place within operational area, with one common attendant for both mobile toilet and drinking water kiosk. Cost includes charges for emptying bottom tank through suction machine, shifting cost of the kiosk from one operational area to another area, attendant cost for looking after cleaning and operation, all materials and all labour charges, all incidental charges, leads, lifts and all taxes as applicable from time to time and as specified by Engineer-in-charge
Other Environment, Health & Safety Measures Information dissemination about type and schedule of civil works, utility shifting/damage/emergency repairs, complaint handling and all such issues that affect public near-by residents/building users close to the work zone. Dissemination modes to include display of banners/notices, distribution of handbills, organization of meetings and other appropriate means at least once in a month for the entire project duration.
Provision of Project Information Board in sheet steel and all supports, including fixing and maintenance during the entire project. Minimum board size should be 3 meters x 2 meters, with necessary information in English and local language written in black paint with white back ground. The board details and the required information will be furnished by the Engineer. The complete design, including logo and information to be displayed shall be approved by the Engineer.
Cost of environmental monitoring (air, water and noise) during entire construction period in line with parameters and frequency specified in the EMP. Ambient Air quality, Ambient Noise level and water quality monitoring.
(24 Hourly Ambient Air Quality Monitoring for PM2.5 PM10,SO2, Nox and CO)-Noise Levels (dB) for Day and Night, Water Monitoring- Parameters specified in EMP. AAQ- Once before start of work and thereafter once in every quarter,AAN-Once before start of work and thereafter once in every month, Water monitoring - as specified EMP
Disposal of extra earth/debris/similar unserviceable waste material by mechanical means, including loading, transporting, unloading to pre-approved dumping ground in line with EMP stipulations and as approved by Engineer-In-Charge. (Refer J&K Sanctioned Schedule of Rates 2012, Item code 1.1.2).
Demolishing of unserviceable line materials by mechanical means, including crushing at approved dumping ground in line with EMP stipulations and as per direction of Engineer-In-Charge
Surinder Gupta
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .