Tender Value
₹8.4 L
EMD Value
₹16,800
Closing Date
9 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT G
12 conditions · 1 needing a document upload
(i)For participating in tender for an electrical nature of work, the contractor shall have to possess valid Electrical License of appropriate voltage issued by any State Government under clause 45 of compilation of rule of Indian Electricity rules 1956 or as amended from time to time. Electrifications of 11 KV and above including OHE, "A" class electrical contractor license is essential. (ii) The license can be possessed with one of the partners or in his own name if sole proprietor. Firm should submit a self-attested copy of the electrical contractor license along with the offer, otherwise, the offer will be summarily rejected
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
13 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the Qualifying criteria mentioned in the tender document. It will not be obligatory on the part of tender committee to scrutinize beyond the submitted document of tenderer as far as his qualification for the tender is concerned. The railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
No post tender correspondence shall be entertained after closing of tender even Suo moto post tender letters of the tenderers shall be treated as null/void.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender . Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim what so ever will be entertained by Railway.
The tenderer should upload the documents carefully. The documents uploaded by tenderer should be clearly visible and in legible format.
Indian Railways Standard General Conditions of contract 2022 along with correction slips corrected up to date of closing of tender and the attached documents are part of the tender document.
The offers which are incomplete, without supporting documents, unsigned, conditional, will be summarily rejected.
As per letter No. 2022/CE-I/CT/GCC/Correspondence/ New Delhi, dated 14.05.2024 "On IREPS Module , a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by tenderer had been discontinued on IREPS"
Repair to old sewer line , damage seepage work and anti-termite treatment in DRM's Office at JBP
JBP-L-T-No-39-2025~WCR
JBP-L-T-No-39-2025
Open
Works - General
6 Months
Jabalpur, Madhya Pradesh
₹0
₹16,800
9 Jan 2026
18 Dec 2025
26 Dec 2025
59 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 8,40,477.82 | ||
| — | Item Breakup | for details. | — | ||
| "SDB for Power. TPN DB 4 way (8+12) IP-43 with metal door, with 63A TPN incomer and outgoing having 5 x 32A SPMCB and 5 x 20/16A SP MCB. MCB make - Legrand, Havells, Hager, simens or equivalent " | — | — | — | 19,901.94 | |
| — | Item Breakup | for details. | — | ||
| SDB for light and fan. TPN DB 4 way (8+12) IP-43 with metal door, 4 with ELCB 32A TPN incomer and outgoing having 5 x 10A SPMCB and 5 x 6A SP MCB with pherrol MCB make - Legrand, Havells, Hager, simens or equivalent , | — | — | — | 12,006.56 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of E/Fan 380mm sweep Erection includes and fixing is to be done on already provided finished opening in the wall using required fasteners , their grouting and then connection is to be given from ceiling rose to this fan using cable of 1.5 sq. mm . size Make- Atomberg, Usha , Bajaj,Havells or simillar make) Sample will be approved by comptent authority before supply | — | — | — | 19,216.47 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of 1 x 18/20W LED fittings 4 feet length. The fittings shall have to be erected by the contractor with all fixing accessories/MS clamps, nuts bolts etc. as per requirement at site. "make- Orient, Havells, Bajaj, Surya, CG or similar | — | — | — | 2,925.2 | |
| — | Item Breakup | for details. | — | ||
| "Supply and Erection of Ceiling fan including electronic modular fan regulator, suitable down rod , Metal fan hook, flexible Pipe, with all necesaary arangment (BLDC, 5 star rated, 1200 mm Make- Atomberg, Usha , Bajaj,Havells or simillar make) Sample will be approved by comptent authority befor supply " | — | — | — | 1,23,044.1 | |
| — | Item Breakup | for details. | — | ||
| Point Wiring : This includes provision of wiring with 1.5 sqmm copper starnded PVC insulated wire [ L & N and earth ]from MDB/SDB/ Board to light & fan control board and provision of control switch on common light and fan control board , together with wiring from control board to ceiling rose and provision of ceiling rose , holder on board ; with earth continuity wire; independent for each fitting. Cost of this item is inclusive of distributed cost of common board & wiring from MDB/SDB/Board to common board in addition to items specifically mentioned Make- Legrand. Havells, L&T, ABB or equivailent | — | — | — | 56,491.5 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection , testing and comssioning of 2X2 LIGHT 45 W Led Recessed Luminaire IS:10322/part 5/sec-2/2012 and IS 16107 (Part 2/Sec 1) : 2012 for Recess type make- Golamedal, Orient, Havells or simillr make | — | — | — | 1,19,034.3 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x2.5 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 2.5 sqmm with one wire of 1.5 sqmm for earth conn). | — | — | — | 36,727.5 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x4 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of4 sqmm with one wire of 2.5 sqmm for earth conn). | — | — | — | 28,296 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x 6 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 6 sqmm with one wire of 2.5 sqmm for earth conn). | — | — | — | 27,354 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of 16A & 6 pin socket point on separate circuit and board. Make Havells, Wipro, legrand, Bajaj or equivalent. | — | — | — | 9,354.8 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of 5 pin 5A on separate boards: wires shall run separate from SDB Havells, Phillips, Orient, Bajaj, Goldmedal or equivalent. | — | — | — | 21,179 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of 6A 5 pin socket point on fan and light control board Havells, Wipro, legrand , Bajaj or equivalent. | — | — | — | 1,811.75 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened at the time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. Two/Four module box of Havells, Wipro, Orient, Bajaj or equivalent | — | — | — | 1,175.3 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitablefor modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). Thisincludes masonry work happened at the time of execution of the work and its associated repairs. Allmaterial required for this job will be supplied by contractor. :Six module box of Havells, Wipro, Orient, Bajaj or equivalent | — | — | — | 1,129.5 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened at the time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. Eight module box of Havells, Wipro, Orient, Bajaj or equivalent. | — | — | — | 7,208.75 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened at the time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. Twelve/Eighteen module box of Havells, Wipro, Orient, Bajaj or equivalent. | — | — | — | 3,612.3 | |
| — | Item Breakup | for details. | — | ||
| Cutting of wall for insertion of 1" dia PVC conduit, fixing hardwares for fixing the conduit along with its supply and then replaster it with cement and sand mixture and then painting with matching colour as per existing colour of the wall. Proper joints in pipes, bends/elbows/ junctions are to be provided as per site requirement | — | — | — | 17,888.4 | |
| — | Item Breakup | for details. | — | ||
| "Cable laying on wall /pole and other similar places fixing using MS flat [25x6mm.]clamps, nuts, bolts,screws or nails as per site requirement" | — | — | — | 7,126 | |
| — | Item Breakup | for details. | — | ||
| Provision of maintenance free earthing.thenTesting with earth tester. | — | — | — | 25,680.48 | |
| — | Item Breakup | for details. | — | ||
| Concealed Wirings:25A/32A MCB and socket for air conditioner / Gyser/ Water cooler: (modular) Havells, Wipro, Orient, Bajaj, crompton or equivalent | — | — | — | 14,055.96 | |
| — | Item Breakup | for details. | — | ||
| Dismantling of air cooling plant ( induction motor, water pump , water filter, blower fan etc. dismantling of , nitrile rubber , tank other connected spares part and accesries ) work included tranportation loading, unloading, labour charge ,& service charges , shifting weightment of released material and handing over to new location of JBP Depot. inclusive GST | — | — | — | 31,500 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection , testing and comssioning of 16 A 2 pole with 2 PP 240VOLT MCB | — | — | — | 4,785 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of Call bell Make- Wipro, Bajaj, Philips, orient or equivailent | — | — | — | 899.88 | |
| — | Item Breakup | for details. | — | ||
| Supply, wiring, fixing, connecting, testing and commissioning ofdouble door lockable out door type MDB LT Panel 16 SWG MDB on brick masonary foundation with 1x250A16KA 4 pole MCCBas incoming, outgoing 2x160A 16KA TP MCCB, 2x100A 16 KA TP MCCB, 2x63A TPN MCB,4x40ATPN MCB, 01 no. separate three phase energy meter, 02 nos. ML-3 contactor with 02 nos. digitaltimer,aluminium bas bar, LED indication lamp RYB, 01 no. Three phase CT energy meter connected to incomingsupply & electronic multifunction meter in LT panel. including earthing, MS Channel | — | — | — | 1,06,165.04 | |
| — | Item Breakup | for details. | — | ||
| Excavation of cable trench in cement concrete / tiles and laying of cables | — | — | — | 28,779.6 | |
| — | Item Breakup | for details. | — | ||
| Dismantling of old points with transportation to concerned railway depot with proper accountal | — | — | — | 1,739.7 | |
| — | Item Breakup | for details. | — | ||
| Supply, fixing, testing and commissioning of 1.5 Ton 5 Star rating Split AC, single Phase,dust filter, make Mitsubishi Heavy, O Gernal,daikin, samsung or equivalent with suitable size of stand. Metalic cage, copper tube as per site requirement , and all other accessories required for installation. | — | — | — | 1,09,881.9 | |
| — | Item Breakup | for details. | — | ||
| Erection of water coolers : Water Coolers will be supplied free of cost by the Railways and the same shallbe collected by the contractor from depot, Jabalpur. Erection includes its foundation on proper place,making points on metal clad plug socket etc. | — | — | — | 1,506.89 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Allcorrectionslip.pdf
ATTACHMENT
AC08to10.pdf
ATTACHMENT
39tenderdoc.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .