Tender Value
Refer Docs
EMD Value
₹39,159
Closing Date
1 Dec 2020, 5:00 pmClosed
Executive Enginner
Executive Engineer Water Supply and Sanitation Division No 1 Mansa Village Jawahrke
Improvement of Rural water suplly scheme for village Nangal Kalan in Block and District Mansa Repair of S and S Tank Pump Chamber High Level Tank Filter Beds OHSR Pumping Machinery and water connection to house hold Repair of existing
2020_WB_56188_1
WSSD/MANSA-DIV-1/2020-21/003
Open Tender
Civil Works - Water Works
Item Rate
90 days
Mansa
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
₹39,159
Mansa
18 Jan 2021
16 Nov 2020
2 Dec 2020
16 Nov 2020
1 Dec 2020
16 Nov 2020
24 Nov 2020
Amount
Carriage of Surkhi, Sand, Bajri, Ballast, Stone, Boulders, Kankar,and Building Rubbish
Fine sand Lead 164 KM
Ghaggar sand Lead 314 KM
Bajri Lead 314KM
Filter media Lead 314 KM
Earth filling
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Dismantling concrete
Cement concrete plain 1:3:6 mix
Cement concrete 1:8:16
With stone aggregates 40mm gauge
mixing by mechanical means using concrete mixer volumetric type
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Conglomerate floor 50mm thick cement concrete rete 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggeregate 40 mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
12.5 mm thick cement plaster 1:2
12.5mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at 1.65Kg. Per Sqm laid hot and sanded
Vertical
Cement pointing 1:2 flush on flat brick flooring
White washing (Three coat)
Finishing walls with cement based water soluble exterior paints such as snocem Robbiacem etc. on new work two coats to give an even shade.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position.
panelled, glazed or glazed and panelled
30 mm thick
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)
For shutter area up to 0.50 sqm
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect
Glazing area above 0.09 sqm
4mm thick or 10.78 Kg/ sqm
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
115 mm thick brick on edge lining in herring bone bond/zig-zag or other specified pattern laid in 1:3 cement sand mortar over low density polyethylene over dressed sub grade including laying, trenching & jointing LDPE
On side slopes
Supplying and fixing of ISI Marked CI D-joint (complete with nut, bolts & rubber ring) as per IS:8794 for repair of pipe line including cutting , jointing and testing etc. but excluding cost of excavation complete.
Providing,Layong,fixing and jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications
63mm o/d pipe of 6 Kgf. / sqcm
75mm o/d pipe of 6 Kgf. / sqcm
110mm o/d pipe of 4 Kgf. / sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).
Class PN-1 as per ISI
80mm i/d Sluice Valves flanged
100mm i/d Sluice Valves flanged
150mm i/d Sluice Valves flanged
200mm i/d Sluice Valves flanged
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra.
Class PN-1.0 as per ISI with rubber Flap
200mm i/d Non-return valve
Providing and placing in horizontal layers filtering media screaned washed and cleaned as described below
Top Layer:Top layer :----- Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4mm with uniformity coefficient 2.00 to 3.00) from Pathankot or other approved source
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Size 0.9 m. x 0.9 m.
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects
First class brick on edge paving or flooring laid over and in cement sand mortar 1:5 in ordinary bonded courses or in herring bone or other special courses, to templates, over dressed foundation and to correct longitudinal and cross slopes as shall be required by the Engineer-in-charge. All joints shall be filled with mortar and struck flushed as the work proceeds
Providing house hold connection incuding laying, jointing, fixing testing below ground level MDPE pipe and above of ground level GI pipes (as approved by Engineer-In-Charge), including cost of excavation, Refilling, CI bib cock as per IS:210 with stainless steel, spindle, 15mm i/d GI pipe 2.50 Mtr. and 15 mm i/d MDPE pipe 2 meter (length on average basis) 3" i/d UPVC clamp, ISI marked G.M. ferruleas per IS:2692 connection of 15mm I/D ferrule medium, specials such as tees, bends, sockets, elbow, nipples (100 mm % 150mm) Union Copplings, GI hooks etc.cutting threading making hole in wall and testing in treanches in the ground all material should be of approved make (to the approval of Engineer-in-charge) complete in all respect including cost of carriage. (Ref. CSR item Nos. 28.1,28.36,28.34 B,30.65 B)
on old pipe line
on new pipe line
Repair of existing House Hold connection Providing and laying, jointing, fixing, testing GI Pipe lines including cost of Specials such as tees, bends, sockets, elbow etc. cutting, threading and testing in trenches, ISI Marked G.M. ferrule 15 mm i/d as per IS:2692, drilling and tapping cost iron pipe lines of all diameters and screwing in ferrule,GI Nipple including excavation complete in all respect
Tube Light
Supplying and fixing of LED 23 watt complete in all respects of reputed make in pump chamber.
Providing, installing, testing & Commissioning one no. Electronically actuated, Diaphragm operated, Metering system, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6.0 Litres of Bleaching powder solution/ Sodium Hypo Solution per Hour under maximum delivery pressure up to 7 kg./ sqcm and suction lift not less than 1.5m as per DWSS standard specifications.
Providing & Fixing C.I. assembly & flanged for CI sluice valves & CI bends complete in all respect
Providing fixing Control pannel for Clear water Moter (50 BHP) and Raw water moter (10 BHP) with havel make switch/MCB 40 amp.TP,L&T make 3 pole contractor,Relay 9-15 amp ,ELCB 40 amp 4 pole ,LED indicator,Volt Meter 50/500,AMP Meter,Shunt Capastor 5 KVR,MCB SP 6A,Pannel asseseries ,Panel Box including labour of fitting Complete in all respacts
For Clear water moter (50 BHP)
For Rawr water moter (10 BHP)
Jointing new pipeline with existing pipeline
Minor Repair of OHSR Consisting of Leakage of Container ,Expansion Joints and painting of vertical pipes etc
Provision for making foundation for raw water set and clear water set complete in all respects
Credit for old Sluice valves(80mm,100 mm)
Credit for old Sluice valves(150 mm)
Credit for old Sluice valves(200 mm)
JASSI GOVT CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .