Executive Engineer
Electrical Division PWD Bnr Rohtak
Construction of various residence in the campus of SDO Civil complex at Kalayat in Kaithal Distt. Honble CM announcement Code No. 13764 dated 03.08.2016 Pdg. E.I. only
2020_HRY_146641_1
PWD/Electrical/143828
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jind
Please refer to the letter as per DNIT condition
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Electrical Division PWD BnR RO
₹17,380
Yes
15 Apr 2021
1 Oct 2020
17 Oct 2020
1 Oct 2020
15 Oct 2020
1 Oct 2020
120 days
Amount
( c )Moulded case Circuit breakers. 31.12 © Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections.
31.12 c (i) 15 amp.to 60 amp. 415 V ,10 KA 3-phase
31.12 c (ii) 100 amp.to 220 amp.415 V,10 KA 3-phase
Distrubution board with plug and socket.
31.15 Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc.
31.15 (ii) S.P.N. enclosure for single pole MCB 20 amp
(L) Miniature Circuit Breaker and Isolator
31.17 Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (a) Miniature circuit breakers of 9 KA breaking capacity.
31.17a) (ii) SP MCB 6 amp. to 32 amp.
31.17(a) (ii)SPN MCB 6 amp. To 32 amp.
31.17(a) (ii) TP MCB 6 amp. to 32 amp
31.17(a) (ii) TPN MCB 6 amp. to 32 amp
31.17(a) (iii) TPN MCB 40 amp. to 63 amp
(M) Supply and erection of Fittings and Accessories.
31.18 (vii) Call bell 220 / 230 volts A.C. bakelite with double coil.
31.18 (ix) (b ) Bell push flush type ( without flexible wire ) in existing sheet.
31.18 (xi) Bakelite angle / straight button holder large size
31.18 (xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
31.18 (xxvi) Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
(O) Erection and carriage of fans..
31.20 (i) Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
31.20 (iii) Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.
31.20 (iv) Erection of cabin fan complete with necessary earthing including carriage from local railway station /goods transport /PWD store to the site of work.
31.20 (v) Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick
31.20 (vi) Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
(P) 31.21Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required.
31.21 (xxi) Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness flushed
31.21 (xxii) Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness flushed
31.22 (Q) Earthing
31.22(i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required
31.22(ii) Extra for using salt and charcoal / coke for pipe earth electrode as required
31.22(xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required
31.22(xvi) Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required.
(X) Miscellaneous .
31.35 (vii) Supply and erection of 75 mm x75 mm x 60 mm deep M.S.box for telephone and inter-communication system including 2 pin 5 amp. socket including cost of bakelite sheet .
31.36 PVC insulated wiring in recessed conduit wiring in 1.5 sqmm PVC insulated copper conductor cable in 1.6 mm thick conduit pipe.
( I ) Fan Point -
( b) Medium Point
( c) Long Point.
( II ) Light Point-
(a)Short Point
(b) Medium Point
(C) Long Point.
31.36 (III) Twin control light point with 2 way, 5 amp. single pole switch.
(c) Long point
( VI ) Call bell point including M.S. Box of size 180 mm x 100 mm x 60 mm deep for call bell
( c) Long Point
( VII ) 3-Pin 5 Amp. plug point including earthing the 3rd Pin etc
(a) Short point
(b) Medium Point.
(cLong Point
( VIII ) 3-Pin 15 Amp. plug point with 4 Sqmm PVC insulated copper conductor cable including earthing the 3rd Pin etc.
( c) Long Point
31.40 Supply & erection of PVC unsheathed copper conductor cbale single core 1100 volts grdae in pipe of suitable size excluding cost and erection of pipe.
31.40 (i) Cable size 1.5 Sqmm ( 3/0.81 mm ).
31.40 (iii) Cable size 4 Sqmm ( 7/0.85 mm ).
31.40 (iv) Size 6 sqmm ( 7/1.05 )
31.40 (v) Size 10 sqmm ( 7/1.35
31.41 Supply & erection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work.
31.41 (i) 4-way , SP&N ( Horizontal)
31.41 (v) 4-way , TP&N ( Horizontal) (8+12)
31.41 (vi) 8-way , TP&N ( Horizontal) (8+24)
31.44 Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wal / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work
31.44 (ii) 25 mm dia.
31.66 Supply & fixing of rotary handle for on/off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material requied to complete the job in all respect.
(i) Rotary handle upto 125 Amp. MCCB
M.R. items
NS-1 Supply & erection of M.S. Box made of 16 Gauge of size d 8" x 10" x 4" covered with3 mm thick bakelite sheet white colour of ISI Mark fixed by means of 4 Nos. brass screws with cost of 1 No. 15 Amp. multi socket of ISI Mark and 15 Amp. switch and 3 Nos. 5 Amp. multi-socket with 5 Amp. switches of ISI Mark including fixing the M.S. Box in wall with cost of cement sand mixture including painting of M.S. Box and to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work. (Based on HSR)
NS-2 S/E of sheet steel enclosure distribution board ( Havell's / Standard make ) G Frame 4 Poles recessed in floor / wall / or pedestal suitable for MCCB's including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .