Chief Engineer (ESG)
DCSEM, DAE, V.S. Bhavan, 3rd floor north wing, Anushaktinagar, Mumbai-94
Contract maintenance of electrical installations at non-residential buildings under DCSEM in Anushaktinagar, Old Mandala, Payalipada, Mumbai
2024_DCSEM_830900_1
DCSEM/CQD/QSC/GSS/24-25/ NIT-30, Dt.15.10.2024
Open Tender
Electrical Works
Item Rate
545 days
Anushaktinagar, new mandala old mandala etc mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹0
₹1.7 L
Yes
7 Feb 2025
16 Oct 2024
14 Nov 2024
16 Oct 2024
12 Nov 2024
16 Oct 2024
16 Oct 2024 - 25 Oct 2024
Amount
PART A:-Day to day maintenance & preventive maintenance.
PART B:- Replacement of the following materials required for maintenance as per specifications of Maintenance contract. (Installation cost shall be included in items of Part A).
PART C:- Job works
Description of Work / Item(s)
Amount
Day to day breakdown maintenance of electrical installations at non-residential buildings in Anushaktinagar, New Mandala, Old Mandala, TMC/TIFR ,Payalipada colonies as per clause no.1 tender specifications and as instructed by the Engineer-in-charge.
Preventive maintenance of DBs/LT panels of Non residential buildings yearly as per clause no.2 tender specifications and as instructed by the Engineer-in-charge.
Preventive maintenance & cosmetic maintenance of lighting fixtures / ceiling fans/exhaust fans of Non residential buildings quarterly as per clause no.2 tender specifications and as instructed by the Engineer-in-charge.
Comprehensive maintenance of UPS & Invertors
Maintenance of 5kVA /120V DC, single PH in / single PH out inverter system with IGBT sine wave technology similar to make M/s. Powerzen with 10 nos of 12V, 200AH capacity battery set similar to make M/s. Exide / Tubular all as per tender specifications of work and as instructed by the Engineer-in-charge. Note: 03nos. of invertors are installed at Dispensaries in Anushalktinagar.
Maintenance of 10kVA /8kW Three Phase In / Single Phase out UPS model no.Adapt ITA of M/s Emerson make with 32nos,12 V, 42 AH Qunata model VRLA batteries of make M/s Amararaja batteries Ltd all as per tender specifications of work and as instructed by the Engineer-in-charge. Note:01no. of UPS installed in Security complex in Anushalktinagar.
5kVA/ True online double conversion Single Phase In/out UPS model no. ONFINITI of M/s Legrand (NUMERIC brand) make with 16nos, 12 V, 100 AH Qunata model SMF batteries of make M/s Amararaja batteries Ltd all as per tender specifications of work and as instructed by the Engineer-in-charge. Note:01 nos. of UPS installed in Dombivali dispensary.
3kVA/ 72V DC Single Phase In/out UPS model no.GXT MT+ CX of M/s Emerson make with 36nos, 2 V, 100 AH Qunata model VRLA batteries of make M/s Amararaja batteries Ltd all as per tender specifications of work and as instructed by the Engineer-in-charge. Note:01no. of UPS installed in Vashi dispensary.
6kVA/ True online double conversion Single Phase In/out UPS model no. GXT MTX+ 6KVA of M/s Vertive Liebert make with 16nos, 12 V, 100 AH SMF batteries Note:02 nos.( 1 in each dispensary) of UPS installed in Chembur & Dombivali dispensary.
1kVA Single Phase Inverter of M/s Prompt make with 4nos, 12 V, 100AH SMF batteries Note: 01no. of UPS installed in Andheri Dispensary.
Repairing, installation testing and commissioning of high mast lighting system with navigation light including replacement of all defective materials like lamp holders, gasket / sealing of lamp compartment, internal wiring with suitable wires and terminal blocks, screws and fixing fasteners etc. for proper functioning of high mast lights on 35mtr. highmast pole at PTAAF complex. Note: 1. All the safety precautions shall be taken during execution of the work. 2. Suitable sky boom / Man lifter shall be used for maintenance of light fixtures. 3. All the paths for entering reptiles into the pole shall be close properly to avoid damage of cables. 4. Light fitting direction adjustment for proper illumination in the athletics ground. 5. Igniter, lamp, capacitor, ballast, conduit, flexible cable will be measured separately. 7. All other materials required if any is included in the scope. 8. There are 9nos. of 2Kw metal halide DE type focus lights & 7nos of 2X400W metal halide flood lights on each high mast poles.
Maintenance, cleaning, treatment & testing of Earth pit : Cleaning of earth pit & removing of earth from the earth pit chamber, Salt water treatment using salt water to improve the earth pit resistance value including measurement of earth pit resistance after treatment, greasing of nut bolts, hinges, welding of hinges, etc., painting MS frame & cover with one coat of red oxide & two coats of enamel paint, including painting of Earth pit resistance value & date of testing, all as require & instructed by E-I-C. scope of work includes measurement of earthing strip continuity from earth pit to LT panel.
Description of Work / Item(s)
Amount
LED Light Lamp & Fixtures:
1200mm LED tube with min.2100Lumen output and efficacy of min.100 lumen/W
2000Lm, 1200mm LED extruded aluminium batten IP40 ingress protection with complete with accessories,
4000Lm, 1200mm LED extruded aluminium batten IP40 ingress protection with complete with accessories,
LED bulkhead similar to model no.:WT140W LED7S CW PSU S1 PC of M/S Philips with allen screw etc.
20 W LED lamp with Bio-nut cap
Master T5 HO 54W/865 fluorescent lamp
Metal Halide lamp 2000Watt similar to HQI-TS 2000W / D/S K12S 10X1 of OSRAM make
Metal Halide lamp 400Watt similar to HQI-TS 400W of OSRAM make
2’ LED batten light fitting of 16W having System Efficacy >120 lm/W, system output min 2000 Lumens, THD <10%, Power Factor >0.95, CRI >80, CCT 6500, IP20 CRCA housing , Life L70B50 @ 50k hrs, Ripple <5%. BIS compliant driver High low cut with auto restart feature @ 140-270V, EMC -EMI compliant. Driver shall have 4KV Surge protection. Similar to BN308C LED20S-6500 L60 PSU WH
LED Fixture Accessories :
Electronic ballast for 2X54W T5 lamp similar to model no. EBP 254/258/255 TL5 HO/TLD PL-L 240V of M/s. Philips make
Driver for LED fixture model no. BRP022 P LED 21 CW MR S1 PSU GR P3568 of M/s Philips make
Driver for LED fixture model no.:BRP410 LED CW 072 MR FG S1 PSU GR of M/s Philips make
Igniter for Metal Halide lamp 2000Watt.
Igniter for Metal Halide lamp 400Watt.
Ballast for Metal Halide lamp 2000Watt.
Ballast for Metal Halide lamp 400Watt.
Holder suitable for T-8 LED tubes
Capacitor
2.5mfd, 400V MPP type capacitor for ceiling fans of M/s. EPCOS make.
4mfd, 400V MPP type capacitor for exhaust fans of M/s. EPCOS make.
32MFD 440V AC Capacitor for 2000W Metal halide fixture
42MFD 250V ACCapacitor for 2x400W Metal halide fixture.
MCB/RCCB/RCBO and enclosures
6 -32A,SP,MCB,10kA B.C.
40-63A,SP,MCB,10kA B.C.
20A/32A,DP,MCB,10kA B.C.
32A,4P,MCB,10kA B.C.
63A,4P,MCB,10kA B.C.
125A MCCB,TP 36kA with neutral link,
Metal enclosure for mounting DP/FP MCB
RCCB RCBO
32A DP,RCBO,30mA,AC type(2module)
32A /25A,FP,RCBO,30mA,AC type(4module)
40A, 30mA DP RCCB AC type
63A, 30mA DP RCCB AC type
40A, 30mA FP RCCB AC type
63A, 30mA FP RCCB AC type
Copper lugs reducer type / Heavy duty tube terminal type for following sizes of wires/cables
6sq.mm/10 sq.mm reducer type
6sq.mm/10 sq.mm Heavy duty tube terminal type
16sq.mm/25sq.mm reducer type
35sq.mm/50sq.mm reducer type
70 sq.mm Heavy duty tube terminal type
Up to 10/16 sq.mm copper ferrule
G.I Fixing fasteners
Coach Screw 3/8” x 3” long
Anchor Fastener 3/8” x 3” long
Anchor Fastener 1/4” x 2” long
Spares of power supply feeder for area lighting/street lighting
Multifunctional digital timer( Similar to AlphaREx D21 astro 1 channel of M/s Legrand make or equivalent of M/s Hager make)
Modular 40A,4P contactor
Modular 25A,2P contactor
1100 V grade PVC insulated, tapped PVC inner sheath and extruded PVC outer sheath, flexible copper conductor power cable of following sizes confirming to relevant IS with up to date amendments and specifications
3 C x 2.5 sq. mm copper flexible cable
3C X 1 sq.mm Flexible copper wires
3C X 0.5 sq.mm Flexible copper wires
Miscellaneous spares
5A,plug top
15A,plug top
White colour sturdy canopy for ceiling fans
16SWG stranded safety chain fro ceiling fans with clamp for fixing
25mm dia G.I flexible conduit PVC coated with adaptor
Danger Sticker Plastic self Adhesive
Electronic Musical door Bell having Poly Carbonated External body, bul bul bell tune, including transformer, transmitter, amplifier, 250 V, AC, Similar in all respect to Vinay Rosy Bell
12V, 200Ah Tubular batteries of Exide make
Description of Work / Item(s)
Amount
Supply and installation of PVC casing – capping / conduit of following sizes as instructed by Engineer-in-charge.
PVC casing – capping of 25 x 16mm fixing on wall / slab / beam with nylon plug and wood screw complete with all accessories and at the intervals of 350mm approx.
PVC casing – capping of 38 x 16mm fixing on wall / slab / beam with nylon plug and wood screw complete with all accessories and at the intervals of 350mm approx.
25mm OD HMS FRLS PVC conduit with accessories like PVC saddles & spacers,couplers,tee,elbows etc. as required on wall / slab / beam with nylon plug and wood screw complete with all accessories
19mm OD flexible PVC pipe
25mm OD Galvanized steel flexible conduit with PVC coating
19mm dia.,14SWG down rod(MS conduit) for ceiling fan including making holes, slit, painting with two coats white enamel paint over one coat of red oxide
19mm dia.,16SWG down rod(MS conduit) for lighting fixture including making treads painting with two coats white enamel paint over one coat of red oxide
Installation of 25mm OD HMS FRLS PVC conduit with supply & installation of new accessories like PVC saddles & spacers,couplers,tee,elbows etc. as required on wall / slab / beam with nylon plug and wood screw complete with all accessories
Supply and installation of PVC conduit junction box 1 way/2way/3way/4way
1 way circularPVC junction box with lid
2way ( Through) circular PVC junction box with lid
3 way circular PVC junction box with lid
4 way circular PVC junction box with lid
PVC gland suitable for 3Cx1.5 sq.mm sq.mm flexible cable
PVC gland suitable for Flexible conduit
Supply, installation, testing & commissioning of 1.1 kV FRLS grade PVC insulated copper wires of following sizes including termination with suitable copper lugs etc.
Supply, installation, testing & commissioning of white colour Switches/ sockets/ DP switches similar to Myrius series of M/s. Legrand make
6 A, SP, one way switch 1 module
6 A, SP, bell push 1 module
6 A, SP, two way switch, 1 module
6 A, 5 pin universal socket with shutter 2 module
16 A SP, one way switch 1 module
6/16 A 3 pin socket with shutter
Ceiling fan regulator 2 module
Blanking plate 1M
Supply & installation of ready made metal flush boxes similar to Myrius series of M/s. Legrand make
1/ 2module
3 module
4 module
6 module
8 module
2 X 4 module
12 (6x2)module
18 module
Supply & installation of Plastic/metal surface boxes similar to Myris series of M/s. Legrand make
1/2 module plastic surface box
3 module plastic surface box
4 module plastic surface box
6 module plastic surface box
8 module plastic surface box
2 X 4 module plastic surface box
12 (6x2)module metal box
18 module metal box
Supply & installation of following White plate cover with frame similar to Myris series of M/s. Legrand make
1 module
2 module
3 module
4 module
6 module
8 module
2 X 4 module
12 (6x2) module
18 module
Supply & installation of following with required hardware.
Batten Holder / Angle holder / pendent holder
Ceiling rose 3plate polycarbonate body.
PVC square box for fixing tube light fixture
5" dia. PVC round plate
Supply, cutting & fixing of 3mm thick Bakelite sheet for installation of modular switch plates including necessary accessories like chromium plated cup washers, GI screws etc. as required & instructed by E.I.C
Providing Ceiling fan hook fabricated out of 150mm x 150mm x 8mm (Approx.) MS sheet with 10 mm MS rod hook welded on MS sheet, holes on corners, hot deep galvanizing & painting with two coat of enamel paint over one coat of red oxide and with four nos. of anchor fasteners 10mm dia ( Approx.), all as required & instruction of Engineer-in-charge (Sample to be got approved) all as required and instructed by Engineer-in-charge.
Providing Ball socket for installation of down rod for lighting fixtures
Supply , installation, testing & commissioning of following MCB DB with suitable coach screws/anchor fasteners on wall/column. Scope of work includes providing danger board on front of DB door and providing SLD pasted on backside of DB door.
20A,2P+E metal clad plug and socket DB similar to model no.507811 of M/s Legrand make with 20A,C-curve, SP, 10kA MCB as controlling switch including all accessories.
32A,3P+N+E metal clad plug and socket DB similar to model no.507862 of M/s Legrand make with 32A,FP,RCBO as controlling switch including all accessories.
12way double door SPN MCB DB similar to Cat. No. 507612 of M/s. Legrand with 32A, RCBO, 2P - 1 no.; 6 to 32A, SP MCB - 10 nos.; cable end box with interconnecting wiring with 1.1kV grade PVC insulated 6sq.mm copper wires
16way double door SPN MCB DB similar to Cat. No. 507613 of M/s Legrand with 25A,FP,RCBO, 4Module -1no.; 32A,DP,changeover switch-1no.; 25A,FP,power contactor-1no.; 0.5A,SP,MCB-1no.; 6 to 32A, SP MCB-5nos.; cable end box with interconnecting wiring with 1.1kV grade PVC insulated 6sq.mm copper wires
8way,IP43, VTPN DB similar to model no.507747 of M/s Legrand with 125A MCCB,TP 36kA with neutral link, 6 to 32A SP MCB- 12 nos., 6 to 32A TP MCB- 4nos., End terminal box similar to model no.507938 of M/s Legrand make
12way,IP43, ETPN DB similar to model no.507673 of M/s Legrand with cable end box and following : 1) 63A,MCB,FP,10kA 2) 63A RCCB 30mA DP-3 nos 3) 6-32A SP MCB C-curve 10kA -30nos 4) PPI Kit 5) SLD, Danger board, etc.
Supply , installation, testing & commissioning 63A,4P change over switch similar to model no.CO21250 OSOO of M/s L&T make with readymade enclosure and end terminal boxes on top and bottom
Supply , installation, testing & commissioning of ceiling fan/ wall fan /pedestal fan/exhaust fan of following sizes including interconnection of fan with ceiling rose/connectors with 1.1KV grade flexible 3C X 1.0sq.mm copper conductor cable with copper lugs etc. as instructed by E.I.C
BLDC ceiling fan 1200mm sweep (similar to Efficio model of M/s Atomberg make) with 16swg safety chain
BLDC ceiling fan 1400mm sweep (similar to Efficio model of M/s Atomberg make) with 16swg safety chain
BLDC ceiling fan 900mm sweep (similar to Efficio model of M/s Atomberg make) with 16swg safety chain
18” industrial wall mounted air circulator (similar to M/s Almonard make)
300 mm,900rpm heavy duty exhaust Fan with frame, impeller and necessary frame work for mounting of the exhaust fan as required
380 mm,900rpm heavy duty exhaust Fan with frame, impeller and necessary frame work for mounting of the exhaust fan as required
400mm BLDC wall mounted fan similar to Renesa of M/s Atomberg make
18” industrial pedestal air circulator
PVC exhaust fan similar to model no. EFFICIO sweep 250mm.
M.S louvers for 300mm / 380mm sweep exhaust fan.
Supply, installation, testing & commissioning of following LED Luminaries with complete accessories like driver etc. suitable for operation on 240 V, 50 Hz. A.C supply ,interconnection with 3C x 1.0 sq. mm flexible copper cable between existing point & fixture, fixing with suitable sizes of coach screws/anchor fastners,clamps etc. and as instructed by EIC
1X20W LED batten similar to TMC 502 1 x T-LED of M/s Philips with 2100lum LED tube with min. 100Lum/watt.
2X20W LED batten similar to TMC 502 2 x T-LED of M/s Philips 2no.s of 2100lum LED tubes with min. 100Lum/watt.
2100 Lm, 1200mm, 100Lum/watt, IP 65 Water proof LED Batten similar to WT150C LED20S of M/s Philips make
4000 Lm, 1200mm, 100Lum/watt, IP 65 Water proof LED Batten similar to WT150C LED40S of M/s Philips make
LED down light luminaire similar to Lunar mid Recess model (L009CTR000) of M/s Lighting Technology make. Scope of work include making suitable cut-out in Lift SS false ceiling if required.
Supply, installation, testing & commissioning of following Luminaries with complete accessories like driver/protective device etc. ,interconnection with 3C x 1.5 sq. mm flexible copper cable between existing point & fixture. etc. suitable for operation on 240 V, 50 Hz. A.C supply as instructed by E.I.C
Street light LED luminaries having minimum output of 2000 lumens and efficacy of 120 lm/watts.
Street light LED luminaries having minimum output of 7000 lumens and efficacy of 120 lm/watts.
Flood light LED luminaries having minimum output of 3500 lumens and efficacy of 120 lm/watts.
Flood light LED luminaries having minimum output of 11000 lumens and efficacy of 120 lm/watts.
Fabrication, supply and installation of swivelling bracket for street light luminaries with 1500 mm long 38 mm dia. G.I. pipe bracket bend into required shape fixed in 450mm long 50 mm dia GI pipe with 3 nos clamping arrangement fixed on surface of slab/beam by 4 Nos. minimum 6mm anchor fastener/on wall with coach screw by means of 300 mm long 40 x 5 mm G.I. strip welded to above 50 mm G.I. pipe with suitable coupler for fixing of lighting fixture.
Supply and installation of IP65 polystyrene thermoplastic cable junction box similar to catalogue No. KF2550 of M/s. HENSEL make with 32A, 4 way, 415V resin cast stud type connector suitable termination cable of size 16 sq. mm, SP MCB C-6A-1no. on DIN channel, 2mm thick G.I. gland plate of suitable size and openable plain cover etc. and as per instructions of E.I.C.
Supply, installation, testing of commissioning of 1100 V grade XLPE insulated, tapped PVC inner sheath and extruded PVC outer sheath, GI wire armoured Aluminium/copper conductor power cable of following sizes confirming to IS-7098 Part – I with up to date amendments and specifications, fixed on wall / column / slab with 4mm thick GI spacer and 16swg thick GI saddles fixed at an interval of 400mm using nylon rawal plug, 10 X 35 mm GI wooden screw etc. for cable sizes up to 35sq.mm/ fixing of cables of sizes above 35sq.mm with 2mm thick saddles on clamps made up of 25X 3mm MS flat at intervals of 500mm using nylon rawal plug, 10 X 50 mm GI coach screw etc./in existing Hume pipes 900 mm below ground level/ in ground at a depth of 900 mm below ground level including excavation in all type of soils excluding hard rock , sand/stone dust bedding, laying of backed bricks(20 nos. per meter) as per IS on side & top, temporary reinstatement, back filling, dewatering if necessary, disposal of excess earth within the radius of 3000 m etc. all as required & instructed by the Engineer-in-charge.
3C X 6sq.mm solid Al. conductor cable in Ground
3C X 6sq.mm solid Al. conductor cable On wall/column
3C X 6sq.mm solid Al. conductor cable in existing Hume pipe/GI pipe/HDPE pipe/excavated trench with out brick and sand
4CX 25sq.mm multistranded aluminium conductor armoured cable in ground / on wall / in pipe
3.5CX 35sq.mm multistranded aluminium conductor armoured cable in ground / on wall / in pipe
3.5CX 50sq.mm multistranded aluminium conductor armoured cable in ground / on wall / in pipe
Installation, testing of commissioning of dept. supplied 1100 V grade XLPE insulated armoured cable of sizes up 31/C X 50sq.mm cable, fixed on wall / column / slab with 4mm thick GI spacer and 16swg thick GI saddles fixed at a interval of 400mm using nylon rawal plug, 10 X 35 mm GI wooden screw etc. for cable sizes up to 35sq.mm/ fixing of cables of sizes above 35sq.mm with 2mm thick saddles on clamps made up of 25X 3mm MS flat at intervals of 500mm using nylon rawal plug, 10 X 50 mm GI coach screw etc./in existing Hume pipes 900 mm below ground level/ in ground at a depth of 900 mm below ground level including excavation in all type of soils excluding hard rock , sand/stone dust bedding, laying of backed bricks(20 no.s per meter) as per IS on side & top, temporary reinstatement, back filling, dewatering if necessary, disposal of excess earth within the radius of 3000 m etc. all as required & instructed by the Engineer-in-charge.
In Ground
On wall/column
In existing Hume pipe/GI pipe/HDPE pipe/excavated trench with out brick and sand
Cable Dressing
Dressing of 3C/4C X6/10sq.mm armoured cable on wall / column / slab with 4mm thick heavy dip galvanized GI spacer and 16swg thick hot dipped GI saddles fixed at a interval of 400mm using nylon rawal plug, 10 X 35 mm GI wooden screw etc.
Dressing of 4C X 16sq.mm to 3.5C X 50 sq.mm armoured cable on wall / column / slab with 4mm thick heavy dip galvanized GI spacer and 16swg thick hot dipped GI saddles fixed at a interval of 400mm using nylon rawal plug, 10 X 35 mm GI wooden screw etc.
Providing cable end termination of the following sizes 1.1kV grade PVC/XLPE insulated armoured cables with solderless, heavy duty tinned copper lugs, brass cable gland, insulation tape, duplicate earthing for cable gland with tinned copper clamp as per relevant IS specification and as per instruction of Engineer in charge.
Up to 4 C x 6 sq. mm PVCA cable
4 C x 10/16 sq. mm PVCA cable
3.5/4 C X 25/35 sq. mm PVCA cable
3 ½ C x 50/70 sq. mm PVCA cable
Installation of 50 mm dia.class B G.I pipe with all fixing arrangements on surface, jointing of pipes with couplers as per required & instructed by the Engineer-in-charge.
Supply, installation, testing and commissioning of earth station with heavy dipped GI earth plates electrode 600 x 600 x6.0 mm in size at the depth minimum of 2.5 m below ground level (bottom of Plate) confirming to IS 3043 complete withall required materials like coke / charcoal, salt, G.I nut bolts, washers, 19 mm dia GI pipe (B class), 150 mm thick concrete wall chamber of suitable size duly plastered, heavy duty (minimum 6 mm thick) M.S chequered plate cover associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements, complete with funnels, GI test links (50 x 6 mm), two runs of 25 x 6mm G.I strips for connecting G.I plate & test link etc. including excavation of ground in all types of soils, refilling & removal of excess earth within a radius of 3000 m etc. all as required as per the drawing specifications & instructed by Engineer-in-charge. Note:- 1. The chamber cover & frame shall be got approved by Department & painted with two coats of red oxide & one coat of enamel paint. 2. Earthing resistance should be less than one ohm.
Supply, installation, testing & commissioning of hot dipped following GI strip fixed to wall / slab / column / beam with 2mm thick GI saddle or in ground at a depth of 750 mm below ground level including excavation in all type of soil , refilling and removal of excess earth within a radius of 500 mtrs., temporary reinstatement and back filling of trench, interconnection of earth strip / wire GI nut bolts & washers, painting with two coats of black bituminous compound for earth strip in ground and green colour enamel painting strip on surface etc. all as required & instructed by the Engineer-in-charge
25X 6mm in ground
25X 3mm in ground
25X 6mm On Wall/column/beam
25X 3mm On Wall/column/beam
Providing earth pit chamber made up of 150 mm thick concrete wall chamber of suitable size duly plastered, heavy duty (minimum 6 mm thick) M.S chequered plate cover associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements etc.
Providing G.I wire of 8SWG along with existing cable. As per instruction of EIC
Earth excavation in hard rock/soft rock & breaking the existing drain walls & reinstatement
Excavating of soft soil including shorting or dewatering, removing of bricks/tiles etc. refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in- charge.
Cutting of asphalt road / concrete flooring /drain of 200 mm depth by using hydraulic drilling machine as required and stacking of rocks, refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in-charge
Excavating in hard rock including shorting or dewatering, removing of bricks/tiles etc. refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in- charge.
Providing Plain cement concrete 1:3:6 using graded stone aggregate of 20 mm maximum size including consolidation, stacking, soling, frame work, shuttering, finishing, curing etc. Complete all as directed by Engineer in charge. Complete all as per specification & as directed by EIC.
Removing & laying of existing old Shahabad stone and paver blocks (60/ 80 mm thick) with care with out any causing any damages to adjacent footpath and paved area etc. , stacking properly the serviceable materials and disposal of unserviceable materials all as per specification and as per direction of Engineer-in-charge.
Installation of RCC Hume pipes of 150 mm Φ(non pressure type) jointing with collars & necessary mortar, excluding excavation and as per instructions of Engineer-in-charge
K Sharma Electricals Private Limited (BID ID -3119115)
PRANIT PROCONCO (BID ID -3119076)
K Sharma Electricals Private Limited (BID ID -3119115)
PRANIT PROCONCO (BID ID -3119076)
PRANIT PROCONCO (BID ID -3119076)
SAMARTH ELECTRIC (BID ID -3111804)
K Sharma Electricals Private Limited (BID ID -3119115)
PRANIT PROCONCO (BID ID -3119076)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .