Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹19.0 L
Closing Date
6 May 2021, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer to NIT
2021_PWDJK_123437_1
e-NIT No.EDJ/13 of 2021-22 Dated 29-04-2021
Open Tender
Electrical Works
Item Rate
45 days
Bakshi Nagar Jammu
please refer BOQ
2 documents required · 2 mandatory
₹0
Exempted
8 May 2021
29 Apr 2021
7 May 2021
30 Apr 2021
6 May 2021
30 Apr 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying, fixing, installation, testing & commissioning of I/O Module Boxes
Supplying & drawing of UTP 4 Pair CAT-6 LAN Cable in the existing surface/recessed steel/pvc conduit as required
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3 Module (100mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing of 600 mm x 600 mm size recessed mounted LED Luminaries 36 watt. having minimum 3600 Lumens with minimum lumens efficiency 115 Lumens/watt.
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture aluminium housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16%
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning (Above to 32 Amp.).
TPN 63 Amp
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and having ROHS certification. The earthing pit should be covered with PVC cover.
Providing and laying of 25 x 5 mm copper strip from copper rod up-to the main panel.
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode shall be tested from CPRI. The earthing pit should be covered with PVC cover.
Providing and laying of 25 x 5 mm G.I strip from G.I rod upto the main panel.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing of Angle/Baten Holder with 9 watt LED Lamp polycarbonate including making complete connnections etc as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
MCCB FP 160 Amp.25 KA ICU=ICS=100%
Change Over Switch 100A FP MCCB Type
Supply, installation, testing & commissioning of 1.1 KV PVC insulated and PVC sheathed XLPE Power Cable of following size etc. along with providing & fixing of Aluminium thimbles, U Clamps, Insulators etc as required including carriage upto site of work.
95 Sq.mm 3.5 Core Armored
70 Sq.mm 3.5 Core Armored
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
Ceiling fan 1200 mm sweep alongwith 1"-2" long fan rod. Prefered make as per list of approved make.
Exhaust fan 300 mm size Prefered make as per list of approved make.
Wall fan 400 mm size Prefered make as per list of approved make.
Supplying and fixing of (50 + 5) watt LED Street Light complete with M.S/GI pipe bracket duly embeded along the parapet /wall including complete connections as required.
Supplying and fixing of (70 + 5) watt LED Street Light complete with M.S/GI pipe bracket duly embeded along the parapet /wall including complete connections as required.
Supply, Installation, Testing and commissioning of 63 kVA Copper wound Automatic Servo Voltage Stabilizeras per the Specifications Below:- EQUIPMET - SERVO VOLTAGE STABILIZER 63 KVA 3 Phase Digital Microcontrolled Servo Stabilizer Capacity - 63 KVA Input Voltage - 150-460 volts (Phase to Phase) 90-270 volts (Phase to Neutral) Output Voltage - 400 volts ± 1% (Phase to Phase) 230 volts ± % (Phase to Neutral) Type - Suitable for : 100 % UNBALANCED LOAD & 100 % UNBALANCED SUPPLY COMPLETE WITH BYPASS SYTEM.
Supply, testing & commissioning of 20 KVA true online, DSP controlled online UPS with 3 Phase AC input and 3 Phase AC output with SMF Battery Bank for minimum 120 minutes battery backup with MS rack & accessories (min. VAH required for battery bank= 108000 VAH ), The UPS should be with 3 level IGBT Based rectifier & inverter technology with inbuilt/external 20KVA Galvanic isolation transformer of same OEM make and with touch screen LCD/LED display for monitoring of its status. UPS should have following features:- UPS power factor: Input PF should be > 0.99 and output PF= unity, efficiency: overall efficiency (upto 96% without isolation transformer), communication interface :RS232/USB port and optional SNMP port for remote monitoring, Audible Alarm: Mains failure/low battery/UPS warning/overload/fault & bypass mode, CERTIFICATIONS & Standard: ISO certification, EN/IEC 62040-02, EN/IEC 62040-3 compliance & CE/UE certification, compatibility with DG Genset, built in Automatic & maintenance bypass switch, with emergency power off (EPO) feature, UPS should be scabale upto 6-8 same rating UPS in parallel mode. Warranty: 2 year on UPS and 2 year on batteries, Battery Make : Exide/Amaron/Quanta/Panasonic Make only with flexibility in no. of batteries i.e UPS VDC flexibility. Approved brand: APC-Schneider /Emerson-Vertiv/Legrand-Numeric/Mitsubishi/G.E only (As per technical Specification enclosed)
Ganesh Sharma
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .