| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.3 LQualified Make: Firestop
Model: Firestop & FEC4 20 AMARNATH INDUSTRIAL ESTATE ASARWA CHAKLA S O AHMEDABAD ASARWA AHMEDABAD GUJARAT 380016 UDYAM GJ 01 0114231 | AHMADABAD | GUJARAT | 380016 | Make: Firestop
Model: Firestop & FEC4 | L1 | Qualified | |
| 2 | Qualified Make: Aim-EX
Model: Aim-EX co2 TYPE 4.5 kg 390 B DINKAR PADA KONDLE VILLAGE KUDUS WADA MUMBAI MAHARASHTRA 400086 | MUMBAI SUBURBAN | MAHARASHTRA | 400086 | Make: Aim-EX
Model: Aim-EX co2 TYPE 4.5 kg | - | Qualified | |
| 3 | L2₹1.3 L+₹124 (0.09%)Disqualified Make: QUEENFIRE
Model: QF-CO2-4.5 107 TIRUPATI INDUSTRIAL ESTATE SUBHASH NAGAR VILLAGE ROAD BHANDUP WEST MUMBAI 400078 N N 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | Make: QUEENFIRE
Model: QF-CO2-4.5 | L2 | Disqualified | |
| 4 | Disqualified Make: ATCO
Model: ATCO AIRTECH ENTERPRISES JE 9 105 FIRST FLOOR OPPOSITE M BLOCK TIKONA PARK MALVIYA NAGAR NEW DELHI 110017 SOUTH DELHI | SOUTH DELHI | DELHI | 110017 | Make: ATCO
Model: ATCO | - | Disqualified | |
| 5 | Disqualified Make: NA
Model: KATAX FIRE 2 B 11 VISHWA KARMA COLONY SHASTRI NAGAR JAIPUR RAJASTHAN 302016 | JAIPUR | RAJASTHAN | 302016 | Make: NA
Model: KATAX FIRE | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Jul 2018, 5:00 pmClosed
Portable Fire Extinguishers IS 15683 Average Turn Over of Last 3 Years 050 Lakh (s) Experience with Gov. Required 5 Year (s) Portable Fire Extinguishers IS 15683 ( 31 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Carbon Dioxide Based Water Based
Foam Based
Powder Based
Carbon Dioxide Based
Clean Agent Expellant Medium CO2 Extinguishing Medium CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire NA 1
2
NA 1/4 Extinguisher Capacity (Kg) Carbon Dioxide Based Fire Extinguisher Capacity (Kg) 4.5 2
3
4.5
NA Water Based Fire Extinguisher Capacity NA 2
NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 17 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire false - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -30° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 NA - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) 250 kgf/cm2 - Discharge Range for Extinguisher (Meters) >=1 for Class-B - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 8 seconds Fire Rating for Class -A NA - 2/4 Fire Extinguisher Fire Rating for Class -B Fire Extinguisher 21B - Certification BIS Marking Yes - CM/L No.* with Validity Period 7759096 08.07.2019 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 130323 - Test Report Date 14.07.2014 - Name of the Lab First Test & Research Laboratory - Address of the Lab Gurgaon
Haryana-122001 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Chandveer Singh 302012
HQ SOUTH WESTERN COMMAND C/56 APO PIN 302012 (IN FRONT OF TRITON MALL) 31 15 Required No ePBG Required No
283210
GEM/2018/B/40202
Portable Fire Extinguishers IS 15683
15 days
Rajasthan; Jaipur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Average Turn Over of Last 3 Years 050 Lakh (s) Experience with Gov. Required 5 Year (s) Portable Fire Extinguishers IS 15683 ( 31 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Carbon Dioxide Based Water Based | - | - | - |
| Foam Based | - | - | - |
| Powder Based | - | - | - |
| Carbon Dioxide Based | - | - | - |
| Clean Agent Expellant Medium CO2 Extinguishing Medium CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire NA 1 | - | - | - |
| 2 | - | - | - |
| NA 1/4 Extinguisher Capacity (Kg) Carbon Dioxide Based Fire Extinguisher Capacity (Kg) 4.5 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA Water Based Fire Extinguisher Capacity NA 2 | - | - | - |
| NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 17 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire false - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -30° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 NA - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) 250 kgf/cm2 - Discharge Range for Extinguisher (Meters) >=1 for Class-B - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 8 seconds Fire Rating for Class -A NA - 2/4 Fire Extinguisher Fire Rating for Class -B Fire Extinguisher 21B - Certification BIS Marking Yes - CM/L No.* with Validity Period 7759096 08.07.2019 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 130323 - Test Report Date 14.07.2014 - Name of the Lab First Test & Research Laboratory - Address of the Lab Gurgaon | - | - | - |
| Haryana-122001 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Chandveer Singh 302012 | - | - | - |
| HQ SOUTH WESTERN COMMAND C/56 APO PIN 302012 (IN FRONT OF TRITON MALL) 31 15 Required No ePBG Required No | - | - | - |
Exempted
10 Jul 2018
3 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_283210.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .