| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹42.0 L+₹5.1 L (13.7%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹42.2 L+₹5.3 L (14.3%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Highest bid quoted | |
| 4 | Rejected-Technical C 223 MIANWALI COLONY GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | - | Rejected-Technical Rejected due to not enlisted with b (i) category | |
| 5 | Rejected-Technical H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | - | Rejected-Technical Rejected due to not enlisted with b (i) category |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
21 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Gurgaon
Gurgaon
PROVN OF CERTAIN BR AND EM SANCTIONED WORKS AT AF STATION GURGAON UNDER GE AF GURGAON
2021_MES_484320_2
CA NO GE/GUR-/NIT-69/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹85,000
20 Jan 2022
30 Nov 2021
23 Dec 2021
30 Nov 2021
21 Dec 2021
7 Dec 2021
60 days
Amount
Excavation in trenches n.exc 1.50mtr wide and 1.50mtr in depth for foundation etc or for shafts, wells cessipts, manhole etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr deth and getting out in soft /loose soil etc complete all as specified and as directed.
Returning filling in, with soil inlcuidng spreading, levelling, watering and well ramming in layers not exc 25 cm thicks etc complete all as specified and as directed.
Removing excavated soil/ building material/debries to a distance exc 250 mtr but not exceeding 500 mtr and depositing where directed etc complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded aggregates) as in foundation and mass concrete etc complete all as specified and directed.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in CM 1:4 etc complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Providing reinforced cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as in coping , with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and as directed.
Earth work excavation in post holes ( or similar holes) in hard/dense soil ,each not exceeding 0.50 Cum ,getting out ,returning filling in and ramming earth or broken rubble mixed with earth around ,in layers not exceeding 25 cm ,watering and removing surplus soil complete all as specified and as directed.
M&L for Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and as directed.
S&F Framed mild steel work as in posts/ struts in fencing including cutting tops to shape, drilling holes,bolting,rivetting flat etc. complete conforming to Fe-290 gde E165 complete all as specified and as directed.
S&F framed brackets of angles cut to shape ,drilled, including bending and welding angles conforming to Fe 410-0 complete all as specified and as directed.
S&F Framed mild steel work as in gates including pintel hinges, stops, hand made sliding bolts etc. complete conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed.
S&F 10 mm dia Machine made screw bolts with hexagonal or square head at one end and screwed the other each screwed end to be fitted with washers and one hexagonal nut exc 5 and not exc 10 cm long complete all as specified and as directed.
S & F 10mm dia MS bars as in strainers for chain link fencing including necessasary welding and fixing to angle iron complete all as specified and directed.
S & F Fe-410-W(GdeE-250) Joist channel, angle or tee sections fixed independently without connecting plates etc as in fencing posts supplied and face complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and any type of standards, rails, straining bolts etc. complete all as specified and as directed.
Supply only Chain link MS galvanised fencing , any size or type complete all as specified and as directed.
Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F rolled sections, MS Angles, MS tubular Structures, MS Channels, Tee, etc. (Fe 410-W Gde-E-250 quality-A) as in main and cross beams, hip and jack rafters, purlins , posts,trusses (framed or unframed) structures where connected to common rafter and running rails and guides for sliding doors, fixed with angles clleats or other connecting plates all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer-in Charge.
Demolition of cement concrete (un-reinforced ) of any description & in any position not specifically provided for including dismantling of floor tiles etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed.
M&L for Vertified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in sub base complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed.
M&L for exterior grade, coloured glossy finish ceramic designer endura tiles of size 30cm X 30cm X 8-10mm thick (as approved by GE) set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade/ colour/ matrix of tiles as in floor etc. complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping, benching, bed block, window cills etc complete all as specified and as directed by Engr-in-charge.
S&F Fe 410-W (Gde-E 250) quality-A Mild steel chequered plates 5mm thick in available sizes as in ducting and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams at regular intervals of 2m to 2.5 m in chequered plate, including bending or turning up, mitred angles, etc. as required as directed by Engr-in-charge
M&L for 20-25mm thick machine cut kota stone slab as in flooring, steps of stair(treads), set with neat grey cement slurry @ 3Kg/Sqm, laid over and including 20mm thick cement and sand mortar (1:6) screed bed/bedding layer, jointed with grey cement slurry mixed with pigment to match the sahde of the slab including rubbing and polishing complete all as specified and as directed.
M&L for, machine cut kota stone slab 18-20mm thick as in skirting/dado, riser of steps, laid over and including 10mm thick backing coat in CM (1:4), set in neat grey cement slurry @ 3Kg/Sqm, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.
M&L for 25mm thick Cement Concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sub floors, flooring for levelling course complete all as specified and as directed
Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA SHEET & suitable frame work/ support made out of 40 x 40 x 5 mm Aluminium, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- ( Location:-)
BUS BAR CHAMBER :- (a) 200 Amp 3 Strips & Neutral Strip 100 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter ( VAF ) - 01 Set. (ii) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iii) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iv) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 200 Amps 25 KA , 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No.
OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA , 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=02 Nos.(For 20 KW Machine) (ii) MCCB 100 Amps 25 KA , 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No. (For AC & Light load) (iii) MCB 63 Amps 10 KA , TPN 'C' curve = 2 Nos. (For E-Rickshaw charging point) (iv) MCB 32 Amps 10 KA , TPN 'C' curve = 1 No. (For 1 KW machine) (v) Spare MCCB 100 A 25 KA 3 Pole = 1 No. (vi) Spare MCCB 63 A 25 KA 3 Pole = 1 No. The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed FRLS Grade cable 1100 volts grade confirming to IS: 694 for phase and neutral drawn in and including medium duty concealed PVC conduit confirming to ISI marked not less than 20mm dia with concealed sunk-in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and painted with stove enamelled black paint top cover 2.80 mm thick plastic laminated sheet of required colour fixed with brass screwes and cup washers including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for the following :- Note: - This is maint work for routine daily complaints and keeping in view the fact contractors has to deply Elect & Helper to complete the daily works alloted and the work shall be completed within 48 hrs failing which Rs 200/- per complaint/day shall be recovered from the contractor.
One light point controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One fan point/Exhaust fan controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One 5 pin socket oulet 5/6 amps on same board including single core stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth dolly all as specified.
One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sqmm of size all as specified and directed.
All as per item No 34 herein before but one 3 pin socket outlet, 15 Amps on independent boards with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fix switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
Supply and fixing socket outlet 2 in 1, 3 pin 5 Amps all as specified and directed at site.
Supply and fix Switch & socket combination in repairs of 5 Amps/16 Amps, 5 in 1, flush type all as specified and directed at site.
Supply and fix ceiling roses, 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
Supply and fix of 20 watt (4ft long) decorative box type fitting with blue coloured end caps for LED tube etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block and testing complete all as specified and directed at site.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed.
S&F submain wiring with unsheathed multi-stranded FRLSH Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core FRLSH Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- 1.Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F submain wiring with unsheathed multi-stranded FRLSH Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for four runs of 6 Sqmm single core FRLSH Grade and One run of 4 sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- 1.Four run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F submain wiring with unsheathed multi-stranded FRLSH Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for four runs of 10 Sqmm single core FRLSH Grade and one runs of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- 1.Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F vertical type load line distribution board, double door, 4 way AC, 3 phase 415 volts, TPN bus bar 200 Amps rating and earth bus and din rail including 01 No. MCCB 3 pole 415 volts, 50 Hz, 100Amps 10 KA breaking capacity as incomer complete .
Supply and fixing in replacement of MCB single pole and neutral 40 /63 Amps 230 volts 'B' series complete all as specified and as directed at site.
Supply and fixing of MCB signle pole 6-32 Amps 230 volts 'C' series complete all as specified and as directed.
Supply and fix MCB, DB , SPN 8 way suitable for single phase 240 volts with 100 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCB's single/double pole complete all as specified and directed at site.
Supply, laying and testing of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 70 Sq mm. complete all as directed. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified & directed.
S&F MCB DP with steel enclosure 2 Module of 40 Amps, 10 KA Cat Part No. DHMCCDPF040 make: Havells complete fitted in wall complete all as specified and directed by Engr-in-Charge.
Supply, Installation, testing and commissioning transformer floor mounted, stepdown, 11 KV/430V complying with IS:2026, copper wound suitable for AC three phase, 4 wire, 50 HZ system, capacity 63 KVA oil immersed, naturally cooled, delta connected on HT side and star connected on LT side, provided with manually operated tap changer on LT side to vary secondary voltage to +7.5% in step of 2.5% each, with standard fittings and accessories all as specified in MES schedule Part-I and with cable end box at HT/LT side with neutral brought out complete with fill of transformer oil maximum level, temp gauges, breather filled with silica gel, oil conservator level with oil level indicator, explosion vent safety release valve, filling drain, sampling and release valve, LT side cable box to be fitted with suitable size of cable gland, connecting with the electrical system including bi-directional rolar and name plate showing vector gramp/ tap changer system with volatge variation all as specified and direcetd by Engr-in-charge.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 Volts grade of size 3 core 95 Sqmm complete all as specified.
Supply and erect 2 pole structure 11 mtr long 410 SP 55 consisting of steel poles with PCC foundations etc alongwith dropout fuse assembly with bottom outside dia and thickness of section with 193.7mmX4.8mm, LA 11 KV 65 kilo amps metal oxide type including excavation, getting out, pole foundation with PCC type D-2 1:4:8 (with 40mm nominal graded aggregate) coping of pole with PCC type-1 :3:6 (with 20mm graded aggregate) and removing surplus soil to a distance not exceeding 50m and making good surface all as specified and directed by Engr-in-charge.
M&L for air break gang operated switch, triple pole, mechanically operated, with contacts of fros bronze and moving contact of copper, vertically mounted (12 insulator type) on insulator and steel frame with operating mechanism including worked from ground level for current rating up tto 200 Amps 11 KV with locking mechanism, mild steel clamp, nuts, bolts, washers of required size including two coats of aluminum paint over a coat of red oxide complete all as specified including drop out fuse assembly (consists of 06 Nos drop out insulators with HT fuse) with fuse carrier explusion type complete all as specified.
Supply and laying Precast concrete cable cover, class HVP, type-I size 300mmX180mmX40mm complete all as specified.
M&L for PCC platform of size 2MX2MX1.5M made out of brick and masonry work suitable for mounting tranformer of 500 KVA capacity and RMU of 630 Amps capacity complete all as specified and directed by Engr-in-charge. Note :- PCC in foundation 1:4:8 type D2, 100mm thick , Pridework in CM 1:4 width one & half bride thick alround and filling with approved and 150mm thick hard core with 100mm thick 1:2:4 type B1 PCC flooring and finishing to sides with 15mm thick 1:4 plaster with 2 coats of cement base paint complete all as specified and as directed
S&F voltage stabilizer for automatic operation, three phase naturally oil cooled, indoor type designed for input variation between 340V to 460V with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 Volts per second and of capacity 50 KVA complete all as specified.
S&F cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminum conductor cable of size 50 to 95 sqmm complete all as specified.
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and directed. Note : 2 Nos earthing shall be considered as one
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed. Note : 2 Nos earthing shall be considered as one
S&F microprocessor based 3 Phase electronic temper proof, CT operated, energy meter for LT supply with optical communication port, accuracy class 0.5 voltage 3X240V, 1/5 A confirming to IS:13779 complete all as specified.
Supply and fixing galvanized iron tubing 40mm bore medium grade with all ISI marked fittings laid in trenches floor/ road or with wall complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting of existing GI pipe line of size 40/50mm dia bore (supply main) and making connection by inserting GI Tee etc and connecting to new GI Pipe line 40/50mm dia complete all as specified and directed by Engineer-in-Charge. Note :- Run lead joint, excavation earth work, measured and paid for separately)
S&F Rotational moulded Polyethylene (HDPE) Water Storage Tank 1000 LITRE Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I, including tank nipple, union and Lowering of unserviceable Water Storage Tank with Float Valve of any description complete all as specified and directed by Engineer in charge.
Supply and fixing of Gun Metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed of size 40mm bore including taking down old valve complete all specified and as directed by Engr-in-Charge.
S&F ball brass valves high pressure with polthene float and fly nut complete of 40 mm dia complete all specified and as directed by Engr-in-Charge.
Chaudhary Constructions
Ish Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .