| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹30.5 L+₹1.2 L (3.96%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹39.6 L+₹10.2 L (34.9%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹46.0 L+₹16.7 L (56.9%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Sept 2024, 6:00 pmClosed
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIRS MAINTENANCE OF DG SETS AMF PANELS CONTROL PANELS AND CONNECTED ALLIED WORKS AT ADE DEBEL AND CERTAIN LABS UNDER GE I R AND D EAST BANGALORE
2024_MES_663189_1
8524/E8
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹90,000
Yes
10 Oct 2024
8 Jul 2024
10 Sept 2024
8 Jul 2024
3 Sept 2024
22 Jul 2024
8 Jul 2024 - 20 Jul 2024
Amount
A Check : Material and labour for monthly inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintenance as directed.
Monthly Service : Checking engine oil level and topping up as and when required . NOTE : Oil shall be measures and paid separately
Checking and adjusting the belt for tension and replacement of belt. NOTE : Belt shall be measured and paid separately.
Checking of oil bath air cleaner level.
Checking of exhaust system for leakage.
Draining of sediment from fuel filter and fuel tank.
Cleaning of air cleaner element.
Checking engine alternator coupling, mounting bolts and alignment
Tighting all nuts, bolts, in alternator terminal block
Checking of alternator carbon brush and connections in alternator
Checking and tighting of all connection in DC control wiring.
Checking of all radiator rubber hose and replacement if required. NOTE : Hose pipe shall be measured and paid separately
Checking and recording oil pressure, water and oil temperature
Checking anti vibration mounting and replacement if required. NOTE : Anti vibration pad shall be measured and paid separately
Checking throttle linkage
Checking battery for cell test, electrolyte level, gravity and topping up to required level
Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit.
Checking of AMF panel, all electrical connections etc.
Checking of earthing resistance
Cleaning of vegetation around the DG set up to 1.5 mtr area.
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : DEBEL
365 KVA Capacity, Make :Cummins, Model QSN 14GI Location : Nirbhay/Rustom II
250 KVA Capacity, Make : Cummins, Model 6CTAA8.3-G4 TA, Location : P -63
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 TA, Location : DEBEL, Sameeksha (02 Nos)
200 KVA Capacity, Make : Kirlosar, Model NTA-743-G, Location : ADA II
200 KVA Capacity, Make : Greaves, Model- 6G11TAG29 , Location : MAV ADE
160KVA capacity, Make : Greaves, Model 6G11TAG26, Location : USD Hanger
125 KVA Capacity, Make : Kirlosakar, Model 6BTA5.9 G5, Location : Simulation
125 KVA Capacity, Make : Cummins, Model 6R1080TA, Location : A&K
125 KVA Capacity, Make : Kirloskar, Model 6RTA/125, Location : SED
125 KVA Capacity, Make : Cummins , Model 6BTAA5.9-G3, Location : IDST& MMD-02 NOS
125 KVA Capacity, Make : KIRLOSKAR , Model 6R1080TA, Location : A HILLS
125 KVA Capacity, Make : KIRLOSKAR CUMINS , Model NTC495G, Location : R2 hanger
100 KVA Capacity, Make : KIRLOSKAR, Model- KG10045, Location : DEBEL
100 KVA Capacity, Make : Kirloskar MODEL NO- 68TAA5.9-G3 Location : CASSA
100 KVA Capacity, Make : CUMINS MODEL NO-6BTA5.9-G5 LOCATION : FCTS DIV
100 KVA Capacity, Make : ASHOK LEYLAND MODEL NO-ALU 370/23 LOCATION : CFRE PUMP HOUSE
100 KVA capacity, Make : Greaves, Model UC1274C1 Location : AK Bldg, CTC Hanger, Street light DG at ADE (03 Nos)
81.25 KVA Capacity, Make : KIRLOSKAR MODEL NO-N495G LOCATION : FRP
62.5 KVA Capacity, Make : KIRLOSKAR MODEL NO-4R1040T LOCATION : NISHANT
62.5 KVA Capacity, Make : GREAVES COTTON MODEL NO-3G11TAG25 LOCATION : SANCHAR
62.5 KVA Capacity, Make : KIRLOSKAR MODEL NO-4R810TAG1 LOCATION : PTA
50 KVA Capacity, Make : GREAVES MODEL NO-GPW1150 LOCATION : MK II
37.5 KVA Capacity, Make : ASHOK LEYLAND MODEL NO-ALU370/23 LOCATION : PUMP HOUSE
B' Check once in Six month OR 250 Hrs running of DG set whichever is Earlier : Material and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :-
Repeat the activities of 'A' Check
Replacement of lubricant oil. NOTE: Lub oil are paid separately.
Replacing lubricant oil filter element with 'O' ring
Replacing fuel filter element
Replacing coolant.
Replacing Governer oil
NOTE : B Check kit, coolant shall be measured and paid separately under relevant items. Lubricant oil shall be measured and paid separately under relevant item.
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : DEBEL
365 KVA Capacity, Make :Cummins, Model QSN 14GI Location : Nirbhay/Rustom II
250 KVA Capacity, Make : Cummins, Model 6CTAA8.3-G4 TA, Location : P -63
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 TA, Location : DEBEL, Sameeksha (02 Nos)
200 KVA Capacity, Make : Kirlosar, Model NTA-743-G, Location : ADA II
200 KVA Capacity, Make : Greaves, Model- 6G11TAG29 , Location : MAV ADE
160KVA capacity, Make : Greaves, Model 6G11TAG26, Location : USD Hanger
125 KVA Capacity, Make : Kirlosakar, Model 6BTA5.9 G5, Location : Simulation
125 KVA Capacity, Make : Cummins, Model 6R1080TA, Location : A&K
125 KVA Capacity, Make : Kirloskar, Model 6RTA/125, Location : SED
125 KVA Capacity, Make : Cummins , Model 6BTAA5.9-G3, Location : IDST& MMD-02 NOS
125 KVA Capacity, Make : KIRLOSKAR , Model 6R1080TA, Location : A HILLS
125 KVA Capacity, Make : KIRLOSKAR CUMINS , Model NTC495G, Location : R2 hanger
100 KVA Capacity, Make : KIRLOSKAR, Model- KG10045, Location : DEBEL
100 KVA Capacity, Make : Kirloskar MODEL NO- 68TAA5.9-G3 Location : CASSA
100 KVA Capacity, Make : CUMINS MODEL NO-6BTA5.9-G5 LOCATION : FCTS DIV
100 KVA Capacity, Make : ASHOK LEYLAND MODEL NO-ALU 370/23 LOCATION : CFRE PUMP HOUSE
100 KVA capacity, Make : Greaves , Model UC1274C1 Location : AK Bldg, CTC Hanger, Street light DG at ADE (03 Nos)
81.25 KVA Capacity, Make : KIRLOSKAR MODEL NO-N495G LOCATION : FRP
62.5 KVA Capacity, Make : KIRLOSKAR MODEL NO-4R1040T LOCATION : NISHANT
62.5 KVA Capacity, Make : GREAVES COTTON MODEL NO-3G11TAG25 LOCATION : SANCHAR
62.5 KVA Capacity, Make : KIRLOSKAR MODEL NO-4R810TAG1 LOCATION : PTA
50 KVA Capacity, Make : GREAVES MODEL NO-GPW1150 LOCATION : MK II
37.5 KVA Capacity, Make : ASHOK LEYLAND MODEL NO-ALU370/23 LOCATION : PUMP HOUSE
Supply only B check kit for DG set of following capacities :- NOTE : It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : Debel
365 KVA Capacity, Make :Cummins, Model QSN 14GI Location : Nirbhay/Rustom II
250 KVA Capacity, Make : Cummins, Model 6CTAA8.3-G4 TA, Location : P -63
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 TA, Location : DEBEL, Sameeksha (02 Nos)
200 KVA Capacity, Make : Kirlosar, Model NTA-743-G, Location : ADA II
200 KVA Capacity, Make : Greaves, Model- 6G11TAG29 , Location : MAV ADE
160KVA capacity, Make : Greaves, Model 6G11TAG26, Location : USD Hanger
125 KVA Capacity, Make : Kirlosakar, Model 6BTA5.9 G5, Location : Simulation
125 KVA Capacity, Make : Cummins, Model 6R1080TA, Location : A&K
125 KVA Capacity, Make : Kirloskar, Model 6RTA/125, Location : SED
125 KVA Capacity, Make : Cummins , Model 6BTAA5.9-G3, Location : IDST& MMD-02 NOS
125 KVA Capacity, Make : KIRLOSKAR , Model 6R1080TA, Location : A HILLS
125 KVA Capacity, Make : KIRLOSKAR CUMINS , Model NTC495G, Location : R2 hanger
100 KVA Capacity, Make : KIRLOSKAR, Model- KG10045, Location : DEBEL
100 KVA Capacity, Make : Kirloskar MODEL NO- 68TAA5.9-G3 Location : CASSA
100 KVA Capacity, Make : CUMINS MODEL NO-6BTA5.9-G5 LOCATION : FCTS DIV
100 KVA Capacity, Make : ASHOK LEYLAND MODEL NO-ALU 370/23 LOCATION : CFRE PUMP HOUSE
100 KVA capacity, Make : Greaves , Model UC1274C1 Location : AK Bldg, CTC Hanger, Street light DG at ADE (03 Nos)
81.25 KVA Capacity, Make : KIRLOSKAR MODEL NO-N495G LOCATION : FRP
62.5 KVA Capacity, Make : KIRLOSKAR MODEL NO-4R1040T LOCATION : NISHANT
62.5 KVA Capacity, Make : GREAVES COTTON MODEL NO-3G11TAG25 LOCATION : SANCHAR
62.5 KVA Capacity, Make : KIRLOSKAR MODEL NO-4R810TAG1 LOCATION : PTA
50 KVA Capacity, Make : GREAVES MODEL NO-GPW1150 LOCATION : MK II
37.5 KVA Capacity, Make : ASHOK LEYLAND MODEL NO-ALU370/23 LOCATION : PUMP HOUSE
Supply only coolant, K cool super plus 50-50 Premix.
Supply only Battery water with electrolyte mix.
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil.
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Material and labour for replacement of unserviceable battery 12 V, 150 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Material and labour for replacement of unserviceable battery 12 V, 90 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Dismantling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections, overhauling / servicing the radiator, clearing, removing blockages arresting leakages, assembling back including necessary welding brazing as required, refixing , reconnecting and testing for proper functioning :
37.5 KVA Capacity
62.5 KVA Capacity
100 /125 KVA Capacity
200/250 KVA Capacity
365 KVA Capacity
500 KVA Capacity
Dismantling, removing the alternator / dynamo of from the engine of following capacity of DG Sets, opening up over hauling servicing, replacement of carbon brushes with holders, assembling back, refixing and testing for proper function.
37.5 KVA Capacity
62.5 KVA Capacity
100 /125 KVA Capacity
200/250 KVA Capacity
365 KVA Capacity
500 KVA Capacity
Dismantling, removing the self starter from the engine of following capacity DG Sets, opening up, over hauling / servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function :
37.5 KVA Capacity
62.5 KVA Capacity
75/100 /125 KVA Capacity
200/250 KVA Capacity
365 KVA Capacity
500 KVA Capacity
Dismantling of fuel injector assembly complete from the engine of following capacity of DG sets, reconditioning / serving, replacement of pim spiral, washers, Cup injector, retainer, cup screw etc assembling calibration, setting for proper function refixing and testing for:
37.5 KVA Capacity
50 / 62.5 KVA Capacity
75 /100 / 125 KVA Capacity
200 / 250 KVA Capacity
365 KVA Capacity
500 KVA Capacity
Disconnecting all the connections from alternator of DG Set of following capacity removing the alternator from foundations, transporting to workshop, dismantling completely including starter, roter, removing rotor and bearing cleaning all the parts with thinner and varnishing completely with F class varnishing, applying epoxy coating, reassembling, dynamically balancing the alternator transporting and fixing on frame and realignment within tolerance limit, connecting the alternator with all connections and testing on load completely all as directed.
37.5 KVA Capacity
50/ 62.5 KVA Capacity
75/100 /125 KVA Capacity
180/200/250 KVA Capacity
320 KVA Capacity
500 KVA Capacity
Material and labour for replacement of defective spare parts of DG Sets of capacity 500 KVA, Make : Cummins, Model KTA-19-G9 including connecting and testing all as specified and directed.
Radiator Hose Pipe Set
Air filter (inner & Outer)
Water Pump assembly
Turbocharger repair Kit
V belt
Fuel Pipe
Material and labour for replacement of defective spare parts of DG Sets of capacity 365KVA, Make : Cummins, Model QSN 14GI including connecting and testing all as specified and directed.
Fuel Pipe
Air filter (inner & Outer)
V Belt
Water Pump Kit
Material and labour for replacement of defective spare parts of DG Sets of capacity 250KVA, Make : Cummins, Model 6CTAA8.3-G4 TA & Make : Greaves, Model D3V6TAG21 TA, including connecting and testing all as specified and directed.
Air filter inner
Battery Lead
V Belt
Oil Seal
Material and labour for replacement of defective spare parts of DG Sets of capacity 200 KVA, Make: Kirlosar, Model NTA-743-G, Make: Greaves, Model- 6G11TAG29 including connecting and testing all as specified and directed.
Air filter Inner
Turbo charger repair Kit
Water Pump Assembly
Material and labour for replacement of defective spare parts of DG Sets of capacity 100/125 KVA, including connecting and testing all as specified and directed.
Air Filter
V Belt
Hose Pipe Set
Material and labour for replacement of defective spare parts of DG Sets of capacity 62.5 KVA, Model GIR 20OSL & NRF 225/2 Make: Greaves including connecting and testing all as specified and directed.
Air filter
V Belt
Hose Pipe Set
Material and labour for replacement of defective spare parts of DG Sets of capacity 37.5 KVA, Type 4R 1040 Make: Kirlosker including connecting and testing all as specified and directed.
Air filter
V Belt
Hose Pipe Set
Material and labour for replacement of door hinges of various capacity of DG Set
Supply and fixing battery lead with negative and positive brass terminals of suitable size with 3m length of each lead all as directed
Repairs to AMF Panels of 62.5 KVA to 100 KVA DG set dismantling / taking down of all electrical connections from unserviceable AMF panel to carry out following repairs :- (a) Replacement of unserviceable micro processor auto main failure relay 400 volt AC 3 phase 4 wire system having following parameter :- (i) Display of RYB phase voltage. (ii) Display of generating voltage. (iii) Display of generator frequency. (iv) Display of main frequency. (v) Display of battery voltage. (vi) Display of single phase current. (vii) Display of generator run hurs Make:- C&S / Hitech or equivalent. (b) Replacement of digital multifunctional meter of size 96x96mm having following parameter: (i) Voltage, Ampere and frequency (c) Replacement of digital energy meter 3 phase of size 96 x 96mm. (d) Replacement of safety control relay for cranking-01 Nos. (e) Replacement of burnt out control wiring for panel with suitable size of lugs. (f) Replacement of auto/manual switch
All as per Sl Item No 24 above but for 125 KVA to 250 KVA DG Set
All as per Sl Item No 24 above but for 365 KVA to 500 KVA DG Set
Material and labour for replacement of unserviceable contactor AC operated 4 pole 415 volts suitable for the following capacity of DG set :-
DG set 365 KVA
DG set 250 KVA
DG set 200 KVA
DG set 125 KVA
DG set 100 KVA
DG set 62.5 KVA
Taking out old unserviceable battery charger from the following DG sets replacement with the following battery charger of suitable capacity and checking the terminals including petroleum jelly and spray cleaning and getting test certificate to produce Engineer-in-charge for the following capacities of DG sets all as specified and as directed.
Battery charger 24 volts 20 Amps capacity panel mounted suitable for 500 KVA DG set complete all as directed.
Battery charger 24 volts 10 Amps capacity panel mounted suitable for 200/250/365 KVA DG set complete all as directed.
Battery charger 12 volts 20 Amps capacity panel mounted suitable for 100/125 KVA DG set complete all as directed.
Battery charger 12 volts 10 Amps capacity panel mounted suitable for 37.5/62.5 KVA DG set complete all as directed.
Supply and fix in repairs controller (dia), AVR, start stop relay including complete wiring and necessary modification of main control panel of 500 KVA to 365 KVA DG set including testing on completion of work and taking out old unserviceable parts complete all as directed.
Material and labour for servicing overhauling to complete alternator upto 100 KVA assembly cleaning, varnishing of rotor, starter assembly and replacement of ball bearing front and rear including greasing and testing all as directed.
Material and labour for servicing overhauling to complete alternator upto 125 KVA to 250 KVA assembly cleaning, varnishing of rotor, starter assembly and replacement of ball bearing front and rear including greasing and testing all as directed.
Opening, dismantling and removing of alternator of 100/125 KVA DG set installed at ADE / DEBEL for repair and replacement purpose and to reinstall at site with complete satisfaction, checking and repair of following parts as under :- (a) Diode positive and negative as per capacity of alternator of 100/125 KVA DG Set (b) Automatic voltage regulator card as per capacity of DG Set 100/125 KVA (c) Excitor coil of alternator (d) Xiner IC (e) Bearing front and rear
RAHUL ENTERPRISES (BID ID -3073959)
B5BUILDING SOLUTIONS (BID ID -3072559)
Lucky Enterprises (BID ID -3079756)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .