Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.5 LAccepted-AOC AT DAKRA P O DAKRA DISTT RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L-1 | Accepted-AOC As per recommendation of TC and approval of competent authority | |
| 2 | L-2₹1.6 L+₹12,402.69 (8.52%)Rejected-Finance AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | L-2 | Rejected-Finance As per recommendation of TC and approval of competent authority | |
| 3 | L-3₹1.7 L+₹19,790.96 (13.6%)Rejected-Finance AT SUBHASH NAGAR BESIDE QTR NO CHB 22 P O RAY JHARKHAND PIN 829209 | RAY | RANCHI | JHARKHAND | 829209 | L-3 | Rejected-Finance As per recommendation of TC and approval of competent authority |
Tender Value
₹1.4 L
EMD Value
₹1,760
Closing Date
6 Oct 2023, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area
Shifting, installation and commissioning of 02 no. 5 kVA DG set including provision of power cable control and protection devices at ladieds club, at Pratiksha under Magadh - Sanghmitra Area
2023_CCL_289821_1
GM(MS)/SO(EnM)/e-NIT/23-24/102
Open Tender
Electrical and Maintenance Works
Item Rate
5 days
Office of the general manager M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹1,760
27 Jan 2024
28 Sept 2023
7 Oct 2023
28 Sept 2023
6 Oct 2023
28 Sept 2023
28 Sept 2023 - 4 Oct 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc.as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required . 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. COST FOR 50 METERS
Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. Details of cost for 1 cum
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. Details of cost for 1 cum
Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Details of cost for 10 Metres
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required
Supply of 125 A 25 kA, 4 pole MCB
Supply of 32 A, 415, 4-pole MCCB enclosure
Supply of changeover switch 100 A/4-pole
Supply of 16 sq. mm 4-core aluminium armoured cable (25 m + 20 m = 45 m)
Supply of 10 sq. mm 4-core PVC Aluminium Cable (DG to changeover switch x2 unit) 18 m x 2 =36 m
Supply of Bus Bar 100 A
Unskilled labour 4 nos x 2 day= 8 manshift
Semi Skilled labor 01 no. x 2 day= 02 manshift
Erection Cost of item number 7-12 @ 15%
Total impact of GST for the purpose of CTC
M/S ASHOK ENTERPRISES
ODYSSEY INTERNATIONAL
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_300158.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .