| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹28.4 L+₹2.4 L (9.31%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹30 L+₹4.0 L (15.4%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Third lowest | |
| 4 | L4₹30.7 L+₹4.7 L (18.1%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest |
| Sl No | Description | Qty | Unit | M/s. VIJAY ELECTRICALS L1 | R. P. Suppliers and Construction Co. L4 | M/S MANOJKUMAR M NAGARKATTE L2 | The Rahul Vig L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning of Centrifugal pump sets of capacity 20 HP, three phase, 415 Volt suitable for 80MM/100mm dia pipe for suction and delivery head range 34-50 Mtr, discharge 15 to 22 LPS including provision of suitable PCC foundation for fixing of Pump Sets and complete all as specified and directed.
Note: 1. Standard test certificate for pump and motor has to be submitted by the contractor (cost for the same is deemed to be included in the quoted rate.)
2. Test results like routine test/Pump performance test/Motor performance/material of construction etc shall be submitted by the contactor after installing the pump sets (cost for the same is deemed to be included in the quoted rate.) | 1 | Each Job | 1,35,000 ₹1,35,000 Lowest | 2,00,000 ₹2,00,000 | 1,48,000 ₹1,48,000 | 1,85,000 ₹1,85,000 |
| 2.00 | Supply, install, testing and commissioning of Non Clog Vertical type Submersible Sewage pump sets with chrome steel impeller and cutter, non-clog to pass 25 mm size particles of capacity 15 HP, three phase , 415V, 150mm dia pipe for delivery ,head range upto 34-50m ,discharge 15 to 20 LPS including provision of all suitable accessories for fixing of pump sets including provision of suitable PCC foundation for fixing of Pump Sets and provision PVC submerssible copper Cables 6 core X 10 sqmm from starter to motor complete all as specified and directed.
Note: 1. Standard test certificate for pump and motor has to be submitted by the contractor (cost for the same is deemed to be included in the quoted rate.)
2. Test results like routine test/Pump performance test/Motor performance/material of construction etc shall be submitted by the contactor after installing the pump sets (cost for the same is deemed to be included in the quoted rate.) | 2 | Each Job | 1,96,000 ₹3,92,000 | 1,75,000 ₹3,50,000 | 1,24,000 ₹2,48,000 Lowest | 1,74,855 ₹3,49,710 |
| 3.00 | Supplying, laying, testing and commisioning 100 mm nominal bore ductile iron pipe , spigot and socket including rubber joints , class K-7 complete all as specified and as directed.
Note :- Specials and fittings shall be measured and paid separately. | 65 | RM | 1,700 ₹1,10,500 Lowest | 2,500 ₹1,62,500 | 1,900 ₹1,23,500 | 2,450 ₹1,59,250 |
| 4.00 | Supplying, laying, testing and commisioning 100 mm nominal bore ductile iron pipe , spigot and socket including rubber joints , class K-7 complete all as specified and as directed.
Note :- Specials and fittings shall be measured and paid separately. | 36 | RM | 1,700 ₹61,200 Lowest | 3,000 ₹1,08,000 | 1,950 ₹70,200 | 2,985 ₹1,07,460 |
| 5.00 | S&F GI tubing of 80mm bore medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs, unions, etc., laid in trenches complete all as specified and as directed | 12 | RM | 1,400 ₹16,800 | 1,000 ₹12,000 | 1,800 ₹21,600 | 980 ₹11,760 Lowest |
| 6.00 | S&F Ductile iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for DI pipe upto 150 mm dia complete all as specified and as directed. | 205 | Kg | 150 ₹30,750 | 100 ₹20,500 | 160 ₹32,800 | 90 ₹18,450 Lowest |
| 7.00 | S&F Cast iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for CI pipe upto 150 mm dia complete all as specified and as directed. | 215 | Kg | 150 ₹32,250 | 100 ₹21,500 Lowest | 160 ₹34,400 | 102 ₹21,930 |
| 8.00 | Cutting the existing pipe line insertion of Tee or fixing of slucie valves except DI specials complete all as specified and directed. | 1 | Each Job | 2,500 ₹2,500 | 250 ₹250 | 3,000 ₹3,000 | 202 ₹202 Lowest |
| 9.00 | S&F cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846-2000 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc of 100mm dia complete all as specified and directed | 2 | Each | 12,500 ₹25,000 | 10,000 ₹20,000 | 13,000 ₹26,000 | 9,850 ₹19,700 Lowest |
| 10.00 | S&F cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846-2000 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc of 150mm dia complete all as specified and directed | 2 | Each | 22,000 ₹44,000 | 10,000 ₹20,000 | 3,000 ₹6,000 Lowest | 9,999 ₹19,998 |
Tender Value
₹29.4 L
EMD Value
₹59,000
Closing Date
19 Nov 2025, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
PROVISION OF DEFICIENT 20 HP CENTRIFUGAL PUMP, SUBMERSIBLE SEWAGE PUMP SETS, LT PANELS, AUTOMATIC CHLORINATOR, UPGRADATION OF LAUNDRY MACHINES AND AIR CONDITIONERS (06 JOBS) AT AFS UNDER GE(AF) SAMBRA.
2025_MES_732570_2
GE(AF)/SAM/TOK-35 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE AF Sambra
₹59,000
Yes
18 Dec 2025
5 Nov 2025
26 Nov 2025
5 Nov 2025
19 Nov 2025
13 Nov 2025
Amount
Supply, install, testing and commissioning of Centrifugal pump sets of capacity 20 HP, three phase, 415 Volt suitable for 80MM/100mm dia pipe for suction and delivery head range 34-50 Mtr, discharge 15 to 22 LPS including provision of suitable PCC foundation for fixing of Pump Sets and complete all as specified and directed. Note: 1. Standard test certificate for pump and motor has to be submitted by the contractor (cost for the same is deemed to be included in the quoted rate.) 2. Test results like routine test/Pump performance test/Motor performance/material of construction etc shall be submitted by the contactor after installing the pump sets (cost for the same is deemed to be included in the quoted rate.)
Supply, install, testing and commissioning of Non Clog Vertical type Submersible Sewage pump sets with chrome steel impeller and cutter, non-clog to pass 25 mm size particles of capacity 15 HP, three phase , 415V, 150mm dia pipe for delivery ,head range upto 34-50m ,discharge 15 to 20 LPS including provision of all suitable accessories for fixing of pump sets including provision of suitable PCC foundation for fixing of Pump Sets and provision PVC submerssible copper Cables 6 core X 10 sqmm from starter to motor complete all as specified and directed. Note: 1. Standard test certificate for pump and motor has to be submitted by the contractor (cost for the same is deemed to be included in the quoted rate.) 2. Test results like routine test/Pump performance test/Motor performance/material of construction etc shall be submitted by the contactor after installing the pump sets (cost for the same is deemed to be included in the quoted rate.)
Supplying, laying, testing and commisioning 100 mm nominal bore ductile iron pipe , spigot and socket including rubber joints , class K-7 complete all as specified and as directed. Note :- Specials and fittings shall be measured and paid separately.
Supplying, laying, testing and commisioning 100 mm nominal bore ductile iron pipe , spigot and socket including rubber joints , class K-7 complete all as specified and as directed. Note :- Specials and fittings shall be measured and paid separately.
S&F GI tubing of 80mm bore medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs, unions, etc., laid in trenches complete all as specified and as directed
S&F Ductile iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for DI pipe upto 150 mm dia complete all as specified and as directed.
S&F Cast iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for CI pipe upto 150 mm dia complete all as specified and as directed.
Cutting the existing pipe line insertion of Tee or fixing of slucie valves except DI specials complete all as specified and directed.
S&F cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846-2000 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc of 100mm dia complete all as specified and directed
S&F cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846-2000 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts etc of 150mm dia complete all as specified and directed
S&F foot valve valves of size 100mm dia complete all as specified and as directed.
S&F 3 core flat multistranded copper cable 10 sqmm for Centrifugal pump set including necessary connection and testing complete all as specified and as directed.
Supplying, fixing, commissioning and testing of Non Return Valve(NRV) butterfly type for 100mm dia with by pass arrangement with all necessary connection all as specified and directed
Supplying, fixing, commissioning and testing of Non Return Valve(NRV) butterfly type for 150mm dia with by pass arrangement with all necessary connection all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 600mmX600mmX6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not le. than 1.5 m below normal ground level connected to Galvanized Strip 32mmX6mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 15 mm dia light grade pipe for protection of earth electrode 20 mm dia funnel for watering and testing on completion complete all as specified and directed.
Excavation in trenches not exceeding 1.5m depth and not exc 1.5m wide and getting out in hard / dense soil for laying cable/erecting poles complete all as specified and directed
Returning and filling in soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
S&F GI tubing of 25mm bore medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc fixed complete to walls and ceiling or laid in floors complete all as specified and as directed
S&F Gun metal, globe or gate valves of 25mm dia with iron wheel head, screwed both ends for iron pipe fixed complete all as specified and directed
Supply, fixing, testing and commissioning Chain Pulley Block 1Ton Single fall CPB with chain 8mm thick including fixing arrangements complete all as specified and directed.
M&L for angle, channels or tee sections, fixed independently, without connection plate (Fe 410 grade ) including necessary drilling holes, welded togethercomplete all as specified and directed
Supplying and laying High Density Polyethylene Pipes (HDPE) 150mm bore of pressure rating 6 kgf/cm2 laid in trenches including all fittings complete all as specified and directed
M&L for construction of brick massonry valve pit chamber of inner dimension 100cmX100cmX100cm suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM(1:6), rendering in CM(1:4) 15mm thick, coping in PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement incl necessary earth work complete all as specified and directed
Supply , install, testing and commissioning of LT Feeder pillar Box 415 V , 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , weather proof , vermin proof indoor type made out of 3.15 mm thick MS sheet protection IP 54 , suitable for outdoor use , with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated with 200A electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI type tested, internal wiring all prewired including the following incoming and outgoing complete all as specified and directed :-
Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core, 10 Sqmm complete all as specified and directed
Supply , install, testing and commissioning of LT Feeder pillar Box 415 V , 50 HZ, 3 Phase 4 wire of suitable size to accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , weather proof , vermin proof indoor type made out of 3.15 mm thick MS sheet protection IP 54 , suitable for outdoor use , with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated with 200A electrical grade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI type tested, internal wiring all prewired including the following incoming and outgoing complete all as specified and directed :-
Supply, installation, fixing and commissioning of split type air conditioner of capacity 1.5 TR, BEE & minimum 5 star rated ,with cordless remote control unit and inbuilt air ioniser, plasma filter for better indoor air quality, suitable for wall mounted single phase 230/250 volt AC including breaking necessary for fixing indoor and outdoor unit and making good to distrubed surfaces with cement morter to match with existing colour after commissioning, making connection between indoor and outdoor unit with copper tubing with proper insulation and making necessary connection unplasticised PVC pipe medium duty 20 mm dia for draining out condensed water all as required including necessary connection complete all as specified and directed Note:-Quoted rate shall be deemed to be included for cost of bracket, drain pipe, hole in brick/stone wall, copper tubing for indoor and out door unit
M&L for submain wiring using 3 runs of single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 02 runs of 4Sqmm of voltage rating 1100V for single phase & neutral, drawn in and including PVC casing caping of dia not less than 25 mm dia with standard acessories, along with two run of FRLSH PVC insulated, unsheathed, stranded copper conductor of size one run x 4 Sqmm as earth continuity conductor all as specified and directed( Note- 2 runs of single core FRLSH PVC cable 4 sqmm for single phase & neutral with one run of 4 Sqmm earth conductor as earth and conduit shall be measured as one unit
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S&F double pole & neutral enclosure with a two pin & earth plug & socket complete with one single pole MCB "C" curve of 20 A rating complete all as specified and directed.
Supplying, installing, testing and commisioning of heavy duty chemical dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 kg/Sqcm comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with chemical grade PVC, NRV alongwith control panel for dosing pump suitable for model SSAPS/CDSPT/25 made of powder coated MS fabricated box consisting of LED indicator, digital volt meter, Amp meter, single phase preventor, High voltage low voltage protection all as specified and directed. Make:- Sathya Sai@/ Sathya Sai Aqua pura services/Fuild control system PVT LTD/Matrix International Model No SSAPS/CDSPT/25
S&F water tubing, unplasticised PVC pipes, of pressure rating 10 kgf/Sqcm laid on floors of 15mm dia complete all as specified and directed
S&F gun metal globe gate valve with iron wheel based screwed both ends for iron pipe complete of 15mm dia complete all as specified and directed
S&F DOL (Direct on Line) Motor starter for 01 HP motor for 01 HP motor set including contractor, over load relay & connected wiring compete all as specified and as directed.
M&L for mild steel angle, channels or tee sections, fixed independently, without connection plate of Fe 410 grade including necessary drilled holes, welded together complete all as specified and directed
M&L for pre-cast cement concrete block masonry with solid blocks, in PCC 1:2:4, type B1, (using 20mm graded stone aggregates) exc 10cm in width and setting in CM 1:6 complete all as specified and directed
M&L for rewinding of electric motor up to 20 HP capacity of laundry machine by dismantling motor, disconnecting cable connections, removing burnt copper wire, rewinding with new super enamelled copper wire (same gauge and turns), applying E-class insulation, varnishing, heating and reassembling for smooth functioning complete all as specified and as directed.
S&F in replacement of roller bearings in laundry machine motors with suitable heavy-duty bearings complete all as specified and directed.
S&F in replacement of LOP (Limit Overload Protector) switch in laundry machines, complete with wiring and testing complete all as specified and as directed.
S&F door gasket for laundry machine front-load drums to ensure water-tight operation complete all as specified and as directed.
S&F water heaters (4KW) for laundry machines including electrical connections complete all as specified and as directed.
S&F in replacement of motor V-belts suitable for laundry machines, including proper tensioning and testing complete all as specified and as directed.
S&F in replacement of drum belts for washing machine drum drive, including alignment and operation check complete all as specified and as directed.
S&F 100 Amps MCCB, 4 Pole, suitable for laundry machine panel complete all as specified and as directed.
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and installation of Direct-On-Line (DOL) Starter suitable for 10 HP laundry motor, complete with enclosure complete all as specified and as directed.
Servicing of laundry machine motor including opening, washing, greasing and replacement of ball bearings complete all as specified and as directed.
S&F cooling fan for laundry motor, complete with nut bolts and alignment complete all as specified and as directed.
M&L for repair/servicing of unserviceable air compressor of capacity 225 liters, maximum working pressure 175 PSIG and hydraulic test pressure 290 PSIG including dismantling of the compressor unit, overhauling of air end, replacement of defective piston rings, valve plates, gaskets, air filter, oil seals, pressure relief valve, and other worn-out consumables, cleaning and flushing of air receiver tank, checking and re-certification of safety valves and testing of the unit at rated working pressure and reassembling, refilling compressor oil, carrying out necessary electrical checks, trial run, and handing over in fully serviceable condition complete all as specified and as directed.
M&L for repair/servicing of unserviceable FABO AIR company ironing unit with connected compressor including dismantling of the ironing unit and compressor assembly and servicing of the ironing bed with replacement of heat-resistant nylon/Teflon cover sheet and padding, checking and rectification of electrical control panel, replacement of damaged steam hoses, testing and certification of safety valves, refilling of compressor oil, reassembly, trial run, and handing over the unit in fully serviceable condition complete all as specified and as directed.
M&L for sub main wiring with 2runs of 2.5 Sqmm PVC insulated FR Copper conductor cable including PVC Casing Capping of Suitable dia along with one run of 2.5 Sq.mm FR copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly complete all as specified and as directed.
M&L for sub main wiring with 2runs of 4 Sqmm PVC insulated FR Copper conductor cable including PVC Casing Capping of Suitable dia along with one run of 4 Sq.mm FR copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly complete all as specified and as directed.
Supply, laying, testing and connecting of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 25 Sqmm, 4 core cable complete all as specified and as directed.
M&L for earthing to Panel / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth STRIP, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately and complition after earthing testing below 2.5 ohm.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in hard/dense soil complete all as specified and as directed.
S&F double wall corrugated HDPE Pipe IS-16205, outer dia 75 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil complete all specified and as directed.
Removing excavated materials /soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and as directed.
S&F galvanised iron pipes 40 mm bore,. light grade, with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors including clumps and nut bolts complete all as specified & directed.
Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 60cm wide and not exc 75cm depth and getting out all as directed including filing back, consolidating etc complete and finishing it with 200mm thick PCC 1:4:8, type D-2 complete all as specified and directed
Supply laying and testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric,1100V, power cables (heavy duty) with stranded aluminium conductor, size of cable 120 sqmm, 3.5 core complete all as specified and as directed.
Supply laying a,nd testing cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric,1100V, power cables (heavy duty) with stranded aluminium conductor, size of cable 95 sqmm, 3.5 core complete all as specified and as directed.
M&L for submain wiring using 6 runs of single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 4 runs of 16Sqmm of voltage rating 1100V for three phase & neutral, drawn in and including PVC casing caping of dia not less than 32 mm dia with standard acessories, along with two run of FRLS PVCH insulated, unsheathed, stranded copper conductor of size 2x 10.0 Sqmm as earth continuity conductor all as specified and directed Note- 4 runs of single core FRLSH PVC cable 16 sqmm for three phase & neutral with two run of 10 Sqmm earth conductor as earth and conduit shall be measured as one unit
M&L for submain wiring using 3 runs of single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 02 runs of 10Sqmm of voltage rating 1100V for single phase & neutral, drawn in and including PVC casing caping of dia not less than 25 mm dia with standard acessories, along with two run of FRLSH PVC insulated, unsheathed, stranded copper conductor of size 2x 6.0 Sqmm as earth continuity conductor complete all as specified and as directed. Note:- 2 runs of single core FRLSH PVC cable 10 sqmm for single phase & neutral with one run of 6 SQMM earth conductor as earth and conduit shall be measured as one unit
M&L for submain wiring using 3 runs of single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 02 runs of 4Sqmm of voltage rating 1100V for single phase & neutral, drawn in and including PVC casing caping of dia not less than 25 mm dia with standard acessories, along with two run of FRLSH PVC insulated, unsheathed, stranded copper conductor of size one run x4 Sqmm as earth continuity conductor all as specified and directed. Note:- 2 runs of single core FRLSH PVC cable 4 sqmm for single phase & neutral with one run of 4 SQMM earth conductor as earth and conduit shall be measured as one unit
S&F Distribution board,double door, 8 way, SPN with 200 Amps rated bus bar 240 Volts complete all specified and as directed.
S&F MCB Single pole, 240 volts 6 to 32 Amps, 10 KA rupturing capacity, 'C' curve complete all specified and as directed.
S&F MCB Single pole & neutral 240 volts 40 to 63 Amps, 10KA rupturing capacity C curve complete all specified and as directed.
S&F Single pole and neutral enclosure with two pin and earth plug and socket with 20 amps MCB SP complete all specified and as directed.
S&F triple pole and neutral enclosure with a three pin and earth plug with socket complete with one TPN MCB 32 Amp 415 volt complete all specified and as directed.
Supply & fix double door TPN DB 4 way TPN with 200 amps rated bus bar, double door complete all specified and as directed.
S&F MCB Triple pole and neutral, 415 volts 63 Amps, 10 KA rupturing capacity, 'C' curve with complete all specified and as directed.
S&F LT panel pillar box cubical type of comprising size (Panel box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door use made out of CRCA sheet 3.15 mm thick powder coated, machine pressed, both side opening with double door (front & rear) in two shalves with provision of rubber beadings and locking system, danger Notice board infront and rear sides including insulated aluminium bus bar of 150Amp capacity, 4 strip mounted on porcelain insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have be independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 50x50x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1 (using 20mm graded stone aggregates) complete including all connections/control wiring incoming/out going with suitable size of copper conductor cable, Foundation is not less than 30 cm below ground level and not less than 45 cm above ground level, legs of panels will be grouted in centre of PCC foundation centre place will be open for connection of Under ground cables including provision of following :- Note: Drawing of LT panel shall be got approved by GE before fabrication.
M/S MANOJKUMAR M NAGARKATTE (BID ID -3483144)
The Rahul Vig (BID ID -3483204)
R. P. Suppliers and Construction Co. (BID ID -3483101)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
tender.pdf
Tender Documents • 1.01 MB
PSii.pdf
Additional Documents • 0.69 MB
BOQ_826884.xls
BOQ • 3.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .