| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹40.4 L+₹2.9 L (7.76%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹42.3 L+₹4.9 L (13.1%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L5₹42.7 L+₹5.2 L (13.9%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹45.2 L+₹7.7 L (20.6%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
21 Jun 2023, 6:00 pmClosed
AJIT KUMAR,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
REPAIR/REPLACEMENT TO FAULTY/DAMAGED HT/LT CABLES WITH JOINTING ACCESSORIES 11 KV OUTDOOR CUBICAL AND HT/LT CABLE END TERMINALS FOR SHANKAR VIHAR,CASSEL ROAD I ,II , VIKRAM VIHAR, ANUJ VIHAR MD ACCN, VRC, AHQ CAMP, DGIS,YOGENDRA VIHAR , CAO POOL,WAR
2023_MES_595724_1
GE/ELEC/D-20/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹76,000
Yes
14 Jul 2023
25 May 2023
23 Jun 2023
25 May 2023
21 Jun 2023
9 Jun 2023
Amount
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 33 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 33 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
(c) PCC cable route indicator shall be paid separately. (d) Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost / cost as finalised by the accepting officer with penalty from the work done.
M & L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Supply and fixing in replacement of galvanised iron strip 32 X 6 mm meter complete all as specified and directed..
Supply, laying, jointing and testing in in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults, XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 to 400 Sqmm,33 KV grade (earth) for 33 KV (E) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed.
Material & Labour for complete jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 to 400 Sqmm complete all as specified and directed.
(a) Against joint failures.
(b) Against breakdown /damages.
Material and labour for supply jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 to 400 Sqmm. Complete all as specified and direceted
(a) Against joint failures.
(b) Against breakdown /damages.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) PCC cable route indicator shall be paid separately. (d)Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done.
supply ,Labour and transport and Laying in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of the following cable sizes,11 KV grade (earth) for 11 KV (E) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed of following sizes
3 core 300 Sq mm
3 core 240 Sq mm
3 core 185 Sq mm
3 core 120 Sq mm
Material & Labour for complete Jointing and testing, indoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm. Against Joint Failures complete all as specified and directed.
All as per srl item No 9 here -in-before but size of 3 core,120 to185 sqmm.
Material and Labour for complete jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 Sqmm. Against joint Failures complete all as specified and direcetd.
All as per srl item No 11 here -in-before but size of 3 core,120 to 185 sqmm.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 V LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) PCC cable route indicator shall be paid separately. (d) Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done.
Supply and Labour in replacement new LT 1100 V end termination with suitable size of aluminium lugs duly crimped for LT 3 ½ core armoured aluminium conductor cable after isolating supply to transformer/LT panel and disconnecting brunt/fault cable from the bunch of cables in trenches, galleries, removing cable loop, opening the cable blank and connecting back after end terminals, testing and commissioning for following sizes all as specified and as directed of following size
3.5 core Cable Size 35 Sqmm to 120 Sqmm
3.5 core Cable Size 150 Sqmm to 240 Sqmm
3.5 core Cable Size 300 Sqmm to 400 Sqmm
Taking down the LT air circuit breakers of various capacities from 800 amps to 1250 amps for repairs, servicing comprising the following and refixing the same, re-orientation and labour for taking down the defective parts and refixing the same spare parts all as specified and directed (a) Checking/repair of mechanical system of ACB. (b) Checking/repair of the manual closing/tripping of breaker.
Material Labour and transport for laying LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults,and of complete lengths as required for laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed of following sizes
4 core, 16 sqmm
4 core, 25 sqmm
3.5 core, 35 sqmm
3.5 core,70 sqmm
3.5 core,95 sqmm
3.5 core,120 sqmm
3.5 core,150 sqmm
3.5 core,185 sqmm
3.5 core,240 sqmm
3.5 core,300 sqmm
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by engineer –in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge, Note : Measurement shall be taken after punning down.
Supplying & laying in replacement un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and direcetd..
Laying only old HT cable cover obtained from excavation complete all as specified and direcetd..
S&Laying in replacement reinforcement precast cbale cover class LV Type-1 Flat size 250x150x40mm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Laying only old LT cable cover obtained from excavation complete complete all as specified and direcetd..
Supply and Laying of GI pipe of 100 mm dia as new provision under re routing complete all as specified and directed.
Supply and Laying of GI pipe of 80 mm dia as new provision under re routing complete all as specified and directed.
Supply and Laying of GI pipe of 50 mm dia as new provision under re routing complete all as specified and directed.
M & L for complete Jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
(a) Against joint failures.
(b) Against breakdown /damages.
M & L for complete Jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 120 to 185 Sqmm.
(a) Against joint failures.
(b) Against breakdown /damages.
M & L for complete Jointing and testing, indoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm. Against Joint Failures complete all as specified and directed.
All as per srl item No 30 here -in-before but size of 3 core,120 to185 sqmm.
M & L for complete jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 Sqmm. Against joint Failures complete all as specified and direcetd.
All as per srl item No 32 here -in-before but size of 3 core,120 to 185 sqmm.
M & L for jointing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade of size 16 to 35 Sqmm x 3.5 / 4 core complete all as directed.
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No34 here -in-before but size of 50 to 70 Sqmm x 3.5 core
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No 34 here -in-before but size of 120 to 185 Sqmm x 3.5 core
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No 34 here -in-before but size of 240 to 300 Sqmm x 3.5 core
(a) Against joint failures.
(b) Against breakdown /damages.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
DS CONSTRUCTION
MV Engineers And Contractors
M/s JAIMAA ASSOCIATES
mayur enterprises
M P TYAGI ENGINEERS AND CONTRACTORS
Vijay Electricals
Bee Kay Engineers & Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .