Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.8 LAdmitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L1 | Admitted-Finance |
Tender Value
₹4.1 L
EMD Value
₹8,110
Closing Date
10 Aug 2026, 11:00 amClosed
Executive Engineer (E)
EE(E), PWD EMD (M-251) Ramesh Park Delhi
RMO Electrical and Mechanical Services at SDM Court Seelampur, Weight and Measurement building and UTCS building Vishwas Nagar, Delhi. (Sub Head- Temporary Illumination of Govt. buildings on Occasions of Independence Day Celebration 2026
2026_PWD_296367_1
58/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
Percentage
3 days
M-2511
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8,110
Yes
11 Aug 2026
4 Aug 2026
10 Aug 2026
4 Aug 2026
10 Aug 2026
4 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing temporary decorative illumination on hire basis at SDM Court Seelampur on occasions of Independence Day Celebration 2026 by providing & fixing decorative chain lights/ batten/ PVC/ cotton strips fitted with batten holder and 2.7/3 watt LED lamps color temperature 2700° K having average spacing of around 400 mm in between the lamps, the arrangement is to be fixed on vertically/ horizontally as well as on different shaped architectural structure like dome/ minaretas/ Arch etc. and providing & fixing 30/50 watt LED lamps/flood light color temperature 2700° K to be fixed on walls/existing poles/floor of dome etc. as required . The minimum size of wires for connecting the LED Bulb i/c circuit wiring shall be 2x1.5/2x2.5 sq mm copper conductor and from existing main panel board to sub panel board should be 3x6 mm² aluminium conductor unarmoured cable (or As per direction of Engineer-in-charge) on the terrace. The system should be connected to earthing stud at main panel, including maintaining the entire system every events by providing and fixing the following materials complete as required. The Total 2.7/3 watt LED lamp (2700⁰K, efficiency ≥ 85%, B22 Type, surge protection≥3KV):-2500 Nos. (approximately). The Total Min.30/50 watt LED flood light:-46 Nos. | |||||
| 1.1 | For Independent Day (13-08-2026 to 15-08-2026) | - | Job | - | - |
| 2Providing temporary decorative illumination on hire basis at Weight & Measurement Building on occasions of Independence Day Celebration 2026 by providing & fixing decorative chain lights/ batten/ PVC/ cotton strips fitted with batten holder and 2.7/3 watt LED lamps color temperature 2700° K having average spacing of around 400 mm in between the lamps, the arrangement is to be fixed on vertically/ horizontally as well as on different shaped architectural structure like dome/ minaretas/ Arch etc. and providing & fixing 30/50 watt LED lamps/flood light color temperature 2700° K to be fixed on walls/existing poles/floor of dome etc. as required . The minimum size of wires for connecting the LED Bulb i/c circuit wiring shall be 2x1.5/2x2.5 sq mm copper conductor and from existing main panel board to sub panel board should be 3x6 mm² aluminium conductor unarmoured cable (or As per direction of Engineer-in-charge) on the terrace. The system should be connected to earthing stud at main panel, including maintaining the entire system every events by providing and fixing the following materials complete as required. The Total 2.7/3 watt LED lamp (2700⁰K, efficiency ≥ 85%, B22 Type, surge protection≥3KV):-2500 Nos. (approximately). The Total Min.30/50 watt LED flood light:-46 Nos. | |||||
| 2.1 | For Independent Day (13-08-2026 to 15-08-2026) | - | Job | - | - |
| 3Providing temporary decorative illumination on hire basis at UTCS Building at Vishwas Nagar on occasions of Independence Day Celebration 2026 by providing & fixing decorative chain lights/ batten/ PVC/ cotton strips fitted with batten holder and 2.7/3 watt LED lamps color temperature 2700° K having average spacing of around 400 mm in between the lamps, the arrangement is to be fixed on vertically/ horizontally as well as on different shaped architectural structure like dome/ minaretas/ Arch etc. and providing & fixing 30/50 watt LED lamps/flood light color temperature 2700° K to be fixed on walls/existing poles/floor of dome etc. as required . The minimum size of wires for connecting the LED Bulb i/c circuit wiring shallbe 2x1.5/2x2.5 sq mm copper conductor and from existing main panel board to sub panel board should be 3x6 mm² aluminium conductor unarmoured cable ( or As per direction of Engineer-in-charge) on the terrace. The system should be connected to earthing stud at main panel, inclusive communication system (Walky-talky) arrangement to co-ordinate work progress including maintaining the entire system every events by providing and fixing the following materials complete as required. The Total 2.7/3 watt LED lamp (2700⁰K, efficiency ≥ 85%, B22 Type, surge protection≥3KV):-6500 Nos. (approximately).The Total Min.30/50 watt LED flood light:-46 Nos. | |||||
| 3.1 | For Independent Day (13-08-2026 to 15-08-2026) | - | Job | 0.29 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.09 MB
BOQ_394496.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .