Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.7 Cr+₹13.2 L (5.08%)Admitted-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹2.7 Cr+₹13.2 L (5.08%) | L2 | Admitted-Finance |
| 3 | L3₹3.1 Cr+₹51.9 L (20.0%)Admitted-Finance 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹3.1 Cr+₹51.9 L (20.0%) | L3 | Admitted-Finance |
| 4 | L4₹3.2 Cr+₹58.4 L (22.5%)Admitted-Finance 6 NEW SADGURU NANIK INDUSTRIAL ESTATE OFF WESTERN EXPRESS HIGHWAY GOREGAON E MUMBAI 400063 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | ₹3.2 Cr+₹58.4 L (22.5%) | L4 | Admitted-Finance |
| 5 | L5₹3.3 Cr+₹71.0 L (27.4%)Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹3.3 Cr+₹71.0 L (27.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL ENTERPRISES L1 | PREMIER ENGINEERING TECHNICS PVT. LTD. L4 | Blue Star Limited L5 | Sterling and wilson pvt ltd L3 | DElite System Engineering (India) Pvt. Ltd. L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00SH I: FMC of Internal, External E & M Installations, All type of Air Conditioners and water coolers. | ||||||||
| 1.01Facility Management of Internal and External Electrical Installations, split AC, window AC , cassette AC, Ductable AC and all type of Water coolers at Integrated Cargo complex , (Import & Export Cargo, CUDCT- I to III) etc, i/c repairs and maintenance, attending to complaints / faults/ breakdown and taking rectification action, ensuring serviceability / satisfactory working condition of the of LT panels at switch rooms,systems repair/replacement of circuit wiring, switches, lamps, chokes, fixtures, DB's (Required replacement of materials shall be issued by AAICLAS at free of cost) i/c providing consumable material like cotton waste, oil, grease, etc. & other sundry material required for cleaning at site etc. as required including ensuring 100% serviceability of installations in cargo movement area, preventive maintenance, maintenance of records / data entries and documentaton including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts (8Hr/Shift) basis on all days including Sundays and holidays as per manpower details given in Annexure "M". | ||||||||
| 1.02 | For First Year | 12 | Months | 6,97,205 ₹83,66,460 Lowest | 8,22,500 ₹98,70,000 | 7,75,332 ₹93,03,984 | 7,98,508 ₹95,82,096 | 7,36,818 ₹88,41,816 |
| 1.03 | For Second Year | 12 | Months | 7,05,120 ₹84,61,440 Lowest | 8,22,500 ₹98,70,000 | 7,75,332 ₹93,03,984 | 8,38,434 ₹1,00,61,208 | 7,36,818 ₹88,41,816 |
| 2.00SH II: ARC for Wiring, Cable Laying and Other Repair Works for Internal & External E & M Installations. | ||||||||
| 2.01Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc complete as required. | ||||||||
| 2.02 | Group B | 100 | Points | 950 ₹95,000 | 1,152 ₹1,15,200 | 1,904 ₹1,90,400 | 1,750 ₹1,75,000 | 900 ₹90,000 Lowest |
| 3.00 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing etc complete as required | 300 | Mtrs | 340 ₹1,02,000 | 342 ₹1,02,600 | 353 ₹1,05,900 | 365 ₹1,09,500 | 250 ₹75,000 Lowest |
| 4.00Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit etc complete as required. | ||||||||
| 4.01 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 500 | Mtrs | 275 ₹1,37,500 | 275 ₹1,37,500 | 279 ₹1,39,500 | 280 ₹1,40,000 | 200 ₹1,00,000 Lowest |
Tender Value
₹3.5 Cr
EMD Value
₹7.0 L
Closing Date
17 Jun 2024, 10:00 amClosed
Regional Manager
AAICLAS, Integrated Air Cargo Complex Meenambakkam Chennai Airport Chennai 600016
Round the clock Maintenance of Internal and External Electrical installations Room Air Conditioners water coolers sliding gates etc at Integrated Air Cargo Complex at Chennai Airport Chennai
2024_AAICL_196481_1
AAICLAS/MAA/FMC/ELECT/2024-25
Open Tender
Electrical Works
Works
730 days
Integrated Air Cargo Complex Meenambakkam
Please refer Tender documents.
24 documents required · 24 mandatory
₹1,180
AAICLAS
₹7.0 L
11 Jul 2024
27 May 2024
20 Jun 2024
27 May 2024
17 Jun 2024
27 May 2024
27 May 2024 - 3 Jun 2024
Amount
SH I: FMC of Internal, External E & M Installations, All type of Air Conditioners and water coolers.
Facility Management of Internal and External Electrical Installations, split AC, window AC , cassette AC, Ductable AC and all type of Water coolers at Integrated Cargo complex , (Import & Export Cargo, CUDCT- I to III) etc, i/c repairs and maintenance, attending to complaints / faults/ breakdown and taking rectification action, ensuring serviceability / satisfactory working condition of the of LT panels at switch rooms,systems repair/replacement of circuit wiring, switches, lamps, chokes, fixtures, DB's (Required replacement of materials shall be issued by AAICLAS at free of cost) i/c providing consumable material like cotton waste, oil, grease, etc. & other sundry material required for cleaning at site etc. as required including ensuring 100% serviceability of installations in cargo movement area, preventive maintenance, maintenance of records / data entries and documentaton including effective supervision etc. as per the detailed specifications, special conditions, terms and conditions covered under the tender clauses on round the clock 3 shifts (8Hr/Shift) basis on all days including Sundays and holidays as per manpower details given in Annexure "M".
For First Year
For Second Year
SH II: ARC for Wiring, Cable Laying and Other Repair Works for Internal & External E & M Installations.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc complete as required.
Group B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing etc complete as required
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit etc complete as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc complete as required.
Group B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing etc complete as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing etc complete as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit etc complete as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc complete as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc complete as required.
5/6 amps Modular switch
15/16 amps Modular switch
3 Pin 5/6A, Modular type Socket (With shutter)
6 pin15/16A, Modular type Socket( With shutter)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc complete as required.
3 module
4 module
6 module
8 module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc complete as required.
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc complete as required.
100 A, 16 KA,TP MCCB
100 A, 30KA, FP MCCB
125 A,36KA,FP MCCB
250 A,50KA,FP MCCB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) etc complete as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc complete as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc complete as required.
Single pole
Double Pole
Supplying and fixing 32 A to 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc complete as required.
63 Amps Triple Pole
63 Amps Triple Pole & Neutral
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc complete as required
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc complete as required.
Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc complete as required.
Supply and installing following size of perforated with powder coating MS cable trays with perforation nor more than 17.5% in convenient section , joined with commectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc complete as required.
300mm width x 50 mm depth x 1.6 mm thickness
450mm width x 50 mm depth x 2.0 mm thickness
Providing of earth pits using Copper bonded Earth electrode of 17.2 mm dia, 3 Metres installed vertically as per the site conditions complete and top cover dully backfilled with backfill earth enhancing compound of 25 kgs. along with required masonary chamber, CI Cover outer size of 450mm X 450mm X 10mm including excavation & refilling etc complete as required.
Providing and fixing 50 mm X 5 mm copper strip in 80 mm dia 'B' Class G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer and brassing i/c excavation of bituminous/ concrete / pavement & excavation of Soil to the depth of 0.30 Mtrs from ground, refilling the Soil and with 1:2:4 concrete on top for 0.15 Mtrs after laying Pipe and making good the same to original surface etc complete as required.
Providing and fixing 50 mm X 5 mm copper strip in recess including cutting of concrete floor and finishing to original floor and connection with brass nut, bolt, spring, washer and brassing etc as complete required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface including connection with brass nut, bolt, spring, washer and brassing for connections etc as complete required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc complete as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc complete as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface etc complete as required
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray etc complete as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade etc complete as required.
3½ X 25 sq. mm (28mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
3½ X 400 sq. mm (82mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade etc complete as required.
3½ X 25 sq. mm
3½ X 35 sq. mm
3½ X 50 sq. mm
3½ X 70 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
3½ X 150 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
3½ X 400 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14333-1996 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
200 mm dia (OD-200 mm & ID-175 mm nominal)
Rewinding with super enamelled copper winding wire, varnishing, baking, overhauling, replacement of ball bearing, capacitor, greasing, refitting etc complete as required of following fans.
600 mm sweep air circulators
450 mm sweep air circulators
1200 mm sweep celling fan
400mm Sweep wall mounting cabin fan
400mm Sweep pedestal fan
300 mm Exhaust fan
450 mm Exhaust fan
Spray painting of LT Panels/feeder pillars / DB's at AAICLAS with two coats of synthetic enamel paint paint of approved shade, make, quality i/c scraping, cleaning and providing metal primer on the surface etc complete as required.
Providing illumination with standard coloured serial lamps 2500 sets per day (containing minimum 20Nos. Of lamps per set)on the city side of Cargo building, car parking area, Lawn & Trees etc., as directed by the Engineer-in-Charge for the each year (illumination on special occasions like Independence day, Deepavali,Christmas,Republic day,New year, Pongal & Ramzan) (in line with the festival the special effect of lights Happy New year, Happy Diwali shall be provided)
Providing illumination with Multicolour LED colour wash flood lights 100 nos per day with required cables & all accessories to illuminate the facia of Integrated Air Cargo complex, Chennai (illumination on special occasion like Independence day, Deepavali,Christmas,Republic day,New year, Pongal & Ramzan)
Supply of LED Aviation Obstruction light in cast aluminium housing with polycarbonate enclosure as per ICAO standards of Bajaj make cat No.BGAV 302 LED or its Equivalent from AAI Preferred make list
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit etc complete as required.
25MM PVC
20MM PVC
SH III : SUPPLY OF ELECTRICAL ITEMS AS AND WHEN REQUIRED
Supply of 100 Watt integrated LED type flood light luminarie with pressure die cast aluminium housing and heat sink in aluminium extrusion with IP65 protection complete with all accessories etc complete as required. (Make:Bajaj, Model: BJFL 100 LED or its Equivalent from AAI Preferred make list)
Supply of 200 Watt integrated LED type flood light luminarie with pressure die cast aluminium housing and heat sink in aluminium extrusion with IP65 protection complete with all accessories etc complete as required. (Make:Crompton, Model: Crompton-CFS-501-200-57-60D-SL-GL-NGG or its Equivalent from AAI Preferred make list)
Supply of 20 Watts (T5) LED tube light, 100 lumen/watt made with polycarbonate material, suitable to operate on 230 V, 50 HZ AC supply etc complete as required.( Make:Orient, Model: 20Watts or its Equivalent from AAI Preferred make list)
Supply of 2 X 2 ft 36 Watt Recess mounted LED type fitting made of CRCA steel, fixture should have minimum efficiency of 100 lm/watt for 6000 deg k complete with all accessories etc complete as required. ( Make:Havells, Model: 36Watts or its Equivalent from AAI Preferred make list)
Supply of 9/10 Watt Recess mounted LED downLight fixture suitable to operate on 230 V, 50 HZ AC supply complete etc complete as required.( Make:Bajaj, Model: LED round panel 09Watts or its Equivalent from AAI Preferred make list)
Supply of 70 WATT LED STREET LIGHT FITTING, luminarie should have minimum efficiency of 130 lm/watt, with pressure die cast aluminium housing and heat sink in aluminium extrusion with IP65 protection complete with all accessories etc complete as required. (Make:Crompton Model:LSTS-70-CDL-M 70 Watts or its Equivalent from AAI Preferred make list)
Supply of 20 Watts (T5) LED tube light fixture(Batten Complete set), 120 lumen/watt made with polycarbonate material, suitable to operate on 230 V, 50 HZ AC supply complete etc complete as required.( Make: Bajaj, Model:IVORA or its Equivalent from AAI Preferred make list)
Supply of 400 mm sweep Oscillating Pedestal fan, suitable to operate on 230 V, 50 HZ AC supply complete etc complete as required.( Make: Bajaj Model: ESTEEM or its Equivalent from AAI Preferred make list)
Supply of 400 mm sweep Oscillating fan for wall mounting with all accessories, suitable to operate on 230 V, 50 HZ AC supply complete etc complete as required.(Make: Crompton Model: Highflo wave) KENDRIA BHANDAR or its Equivalent from AAI Preferred make list)
Supply of 1200 mm sweep energy efficient ceiling fan suitable for operate on 230 V, 50 HZ AC supply with all accessories etc complete as required (Make: Orient or its Equivalent from AAI Preferred make list)
Supply of 1.1 KV grade of following size of armoured Aluminium conductor PVC/XLPE insulated and PVC sheathed cable as per IS 1551(Part I) 1988/IS-7098 (Part I) 1985 respectively with up to date amendments .
4 x 10 sq.mm
3.5 x 25 sq.mm
3.5 x 35 sq.mm
3.5 x 50 sq.mm
3.5 x 70 sq.mm
3.5 x 95.sq.mm
3.5 x 300 sq.mm
Supply of wires with the following sizes of FRLS PVC insulated flexible copper conducting, Single core cable.
Supply of 300 mm sweep exhaust fan suitable for operation on single phase 230 V AC supply i/c all accessories etc complete as required. (Make:Bajaj, Model:BAHAR 300 mm Metallic Grey Exhaust Fan or its Equivalent from AAI Preferred make list)
Supply of spares for existing Halonix fittings 200 watts /100 Watts suitable to operate on 230V, AC 50Hz etc complete as required.
100 watts Drive for the Constant Current LED Driver for the above fitting.
100 Watt: LED lamps fitted on LED MCPCB board having 24 numbers of LED lamps.
200 watts Drive for the Constant Current LED Driver for the above fitting.
200 Watt: LED lamps fitted on LED MCPCB board having 24 numbers of LED lamps.
Supply for spares for LED Display Boards or Sign boards
BAL CX G4 white colour LED Strip with 20 module,1.5 per module OSRAM make or equivalent for replacement in existing LED display Board
LED drive with 300W output power range for outdoor application with IP66 protection Model No: OT FIT 300 of OSRAM or equivalent for replacement in LED display board
Supply of casing and capping 25 mm size with accessories etc complete as required
SH: IV AC, WATER COOLER AND WATER DISPENSER - Spares
Supply of various accessories of split/cassette AC of different makas (Carrier, Blue Star, Voltas, Hitachi, etc)
FAN MOTOR (INDOOR)
Fan Motor Blower
FAN MOTOR (OUTDOOR)
Fan Blade
REPAIR WORK FOR INDOOR SPLIT/ CASSETTE AC
Reparining of Indoor unit coil, i/c arresting of leakage by necessary bracing/welding etc complete as required as per site condition
COMPRESSOR
Compressor 1.5 TR
Compressor 2.0 TR
Inverter Compressor 1.5 TR
Capacitor (2.5 mfd)
Capacitor (3 mfd)
Capacitor (4 mfd)
Capacitor (6 mfd)
Capacitor (50 mfd)
Capacitor (60 mfd)
Contactor 32 Amps for 4 TR Cassette AC
Contactor 64 Amps for 9 TR ductable AC
Supply of various consumables/ accessories for split AC of different makes (Carrier, Blue Star, Voltas, Hitachi, etc.,) consisting of Fasteners( 8 nos ) , White Roll( 10 nos ) , LPG gas for welding 2 kg Tin 8 nos, Welding rod -4 nos , strainer-2 Nos, Capillary tube- 3 mtr, Coil Brush -4 nos, Terminal Clip Box-1 box, Teflon tape-1 box Flare nuts of different sizes 1/4 inch to 5/8 inch all 8 nos each in one Lot
Supply of following items for split AC installation / replacement of existing damaged items
Drain Hose (1/2")
Two way valve (1/4")
Two way valve (3/8")
Two way valve (1/2")
Two way valve (5/8")
Refrigerant Gas (R 22 A)
Refrigerant gas 410 A
Refrigerant Gas (R 32A)
Refrigerant Gas (R 134 A)
Repairs to Split AC /Window AC PC board including replacement of damaged spares, if any complete etc as required
Repairs to Inverter type Split AC PC board including replacement of damaged spares
Supply of A/C Remote (all models)
Supply of various accessories for different type of water cooler (Make: kelby,conway,crossfield)
Adapter (240 / 24 v)
Solenoid Valve
Pump (24 / 36 v) suitable for 100 GPD Membrane
Pump (24 / 36 v) suitable for 300 GPD Membrane
Float valve switch
Heater switch
Thermostat
Heater Coil (1000w)
Thermostat & Cut off
Membrane (100 GPD)
Membrane (300 GPD)
Spun (10 inch)
Spun (20 inch)
Carbon Filter (10 inch long)
Carbon Filter (20 inch long)
Micro Controller based PC board for water cooler
Sediment filter
Ro Water Connectors (Allsizes) elbow/coupling
Different sizes of Hose pipes for RO
Supply of spares for Blue star Make Water dispenser (Model no : GMB-D-23130)
Top load dispenser needle
Flow sensor
Pump for bottom load
Relay and Overload switch
Thermostat for water dispenser
Compressor for water dispenser
Water dispenser tap
Heater tank
Heater thermostat and relay
Micro Controller based PC board for water Dispenser
Supply, Fixing & connection of following size refrigeration pipe (copper) along with suitable size flexible cable with insulation of copper pipe etc., complete as required (for re-installation purpose)
Copper Pipe with Insulation Hose (1/4")
Copper Pipe with Insulation Hose (3/8")
Copper Pipe with Insulation Hose (1/2")
Copper Pipe with Insulation Hose (5/8")
Copper Pipe with Insulation Hose (3/4")
SH V: CMC/AMC/Repairs of Different type of Electrical Installation
CMC of 04 Nos sliding gates including replacement of limit switches, Wheels, MS Rod Rail & other spare Parts in control panel routine and preventive maintenance of all the items covered except rewinding/replacement of motors etc complete as required.
Rewinding of Sliding gate motor
Annual Service contract of 27 Nos of L&T/C&S make low voltage ACB of capacity of ranging from 800 A to 2500 A by carrying out preventive maintenance (Once in Six months) as per OEM's Recommendations (excluding spare) (Service shall be carried by OEM/OEM Authorized service provider)
Repair of Submersible Water Pumps including overhauling/ repairing, supply and replacement of both side bearings, mechanical seal,stud bolts, gland packing, gasket, rubber bush for coupling etc., Cleaning and Greasing of bearings, reassembling, realignment of the pump with motor, testing, commissioning and painting etc. complete as required.
All inclusive comprehensive maintenance of complete boom barrier system , including all spares, consumables and manpower required for trouble shooting, routine, preventive, breakdown maintenance etc., as per OEM recommendations and instructions of engineer-in-charge for maintaining the systems in acceptable functional, operational and serviceable state. (For 04 Nos Boom Barrier)
Servicing of different Sizes HVLS fans incuding program checking and cleaning panel, gear motor oil level checking, safety guy ropes tight check, all bolt, nuts check & blade and hub alignment check., cleaning of blades etc complete as required.
First Year
Second Year
Supply of Synthetic Oil for Gear Motor
DElite System Engineering (India) Pvt. Ltd.
Sterling and wilson pvt ltd
PREMIER ENGINEERING TECHNICS PVT. LTD.
Blue Star Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
FULLNIT.pdf
Tender Documents • 6.52 MB
BOQ_215037.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .