Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹28.3 LAccepted-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹29.3 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹29.7 LRejected-Finance | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FOURTH₹31.6 LRejected-Finance SAI VARENYA PARK VIEW FLAT NO 110 GROUND FLOOR 9TH MAIN 6TH CROSS TURAHALLI BANGALORE 560 061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | FOURTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹31.9 LRejected-Finance | FIFTH | Rejected-Finance BEING NOT LOWEST |
| Sl No | Description | Qty | Unit | Pacific Enterprises L5 | kamadhenu Electricals L3 | GKR and CO L6 | m/s raghavendra kulkarni L7 | G K CONSTRUCTIONS L1 | SREE VARU ELECTRICALS L2 | PRANATHI DEVELOPERS L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable old high bay MH light fittings complete, all as directed.
Note : Inclusive all T&P and other asscessories required to be inclusive part of quoted rate . | 30 | Each | 300 ₹9,000 | 180 ₹5,400 | 100 ₹3,000 Lowest | 210 ₹6,300 | 200 ₹6,000 | 100 ₹3,000 Lowest | 150 ₹4,500 |
| 2.00 | Supply , fixing LED highbay lights 120 watts with housing IP-65and IK 07, circular high pressure die cast aluminium housing and manufacture logo embossed on the housing and high transmittance tempered glass cover, optics lens with lens plate having NB and WB optics , system efficacy>120 lumens /watt, xitanium driver-IP 66 complying to IEC61347-2-13 certification like CE ENEC, ROHS, with rated life of 50000 hrs for driver at TC-80 degree C along with all safely features , thermal protections, protection against input over voltage< 320 volt Ac for 48 hrs , driver failure rate ,0.2% per 1 Khr @ TC 70-80 Deg C, wattage 120 Watts , internal wiring-teflon SDCM<5, CCT -5700, CRI>80, THD<20 at max load , third harmonics <20%, PF>.95 colour temperature 6500k, all are specified and as directed | 30 | Each | 15,000 ₹4,50,000 | 5,900 ₹1,77,000 | 7,200 ₹2,16,000 | 8,000 ₹2,40,000 | 5,800 ₹1,74,000 | 5,750 ₹1,72,500 Lowest | 11,500 ₹3,45,000 |
| 3.00 | M&L for sub main wiring/power wiring with 2 runs of 2.5 sqmm PVC insulated stranded copper conductor FRLS 1100 V cable and one run of 1.5 sqmm copper FRLS 1100V cable as earth lead drawn in existing ERW steel conduit including taking down old unserviceable wiring complete all as specified.
Note : (i) Two runs of of 2.5 sqmm PVC insulated stranded copper conductor and one run of earth wire 1.5 sqmm shall be measured and paid as one unit (ii) If any welding work required deemed in quoted rate. | 250 | Rm | 150 ₹37,500 | 120 ₹30,000 | 120 ₹30,000 | 110 ₹27,500 Lowest | 170 ₹42,500 | 125 ₹31,250 | 130 ₹32,500 |
| 4.00 | M&L for sub main wiring/power wiring with 2 runs of 4.0 sqmm PVC insulated stranded copper conductor FRLS 1100 V cable and one run of 2.5 sqmm copper FRLS 1100V cable as earth lead drawn in Existing ERW steel conduit including taking down old unserviceable wiring complete all as specified.
Note : Two runs of of 4.0 sqmm PVC insulated stranded copper conductor and one run of earth wire 2.5 sqmm shall be measured and paid as one unit (ii) If any welding work required deemed in quoted rate. | 220 | Rm | 210 ₹46,200 | 160 ₹35,200 | 130 ₹28,600 Lowest | 140 ₹30,800 | 280 ₹61,600 | 190 ₹41,800 | 160 ₹35,200 |
| 5.00 | M&L for sub main wiring/power wiring with 4 runs of 6.0 sqmm PVC insulated stranded copper conductor FRLS 1100 V cable and two run of 4 sqmm copper FRLS 1100V cable as earth lead drawn in Existing ERW steel conduit including taking down old unserviceable wiring complete all as specified.
Note : Four runs of 6.0 sqmm PVC insulated stranded copper conductor and two runs of earth wire 4.0 sqmm shall be measured and paid as one unit (ii) If any welding work required deemed in quoted rate. | 130 | Rm | 540 ₹70,200 | 500 ₹65,000 | 320 ₹41,600 Lowest | 350 ₹45,500 | 490 ₹63,700 | 450 ₹58,500 | 420 ₹54,600 |
| 6.00 | M&L for sub main wiring/power wiring with 4 runs of 10.0 sqmm PVC insulated stranded copper conductor FRLS 1100 V cable and two run of 6.0 sqmm copper FRLS 1100V cable as earth lead drawn in existing ERW steel conduit including taking down old unserviceable wiring complete all as specified.
Note : Four runs of 10.0 sqmm PVC insulated stranded copper conductor and two runs of earth wire 6.0 Sqmm shall be measured and paid as one unit (ii) If any welding work required deemed in quoted rate. | 50 | Rm | 900 ₹45,000 | 700 ₹35,000 | 700 ₹35,000 | 490 ₹24,500 Lowest | 900 ₹45,000 | 600 ₹30,000 | 730 ₹36,500 |
| 7.00 | S&F MCB DB, TPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed. | 10 | Each | 10,000 ₹1,00,000 | 2,800 ₹28,000 | 3,800 ₹38,000 | 2,500 ₹25,000 Lowest | 4,500 ₹45,000 | 6,000 ₹60,000 | 7,000 ₹70,000 |
| 8.00 | S&F MCB DB, TPN,8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed. | 6 | Each | 15,000 ₹90,000 | 3,540 ₹21,240 | 6,000 ₹36,000 | 3,500 ₹21,000 Lowest | 7,500 ₹45,000 | 7,000 ₹42,000 | 8,000 ₹48,000 |
| 9.00 | S&F MCB DB, SPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed. | 6 | Each | 1,800 ₹10,800 | 880 ₹5,280 | 1,100 ₹6,600 | 1,600 ₹9,600 | 1,200 ₹7,200 | 750 ₹4,500 Lowest | 1,500 ₹9,000 |
| 10.00 | Supply and Fixing MCB SP 6 - 32 Amps complete all as required and directed. | 60 | Each | 160 ₹9,600 | 165 ₹9,900 | 220 ₹13,200 | 300 ₹18,000 | 180 ₹10,800 | 125 ₹7,500 Lowest | 260 ₹15,600 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
16 Jul 2025, 6:00 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIRS AND MAINTENANCE OF GATE BARRIERS,HANGAR BAY LIGHTS,SUN SHELTER,SHUTTER MOTORS, HIGH MAST LIGHTS, RECHARGE PITS,MICS SECURITY LIGHTS AND ITS ALLIED WORKS AT SDI AND ASTE UNDER GE (AF) MARATHAHALLI
2025_MES_715573_1
8763/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹76,000
Yes
30 Oct 2025
19 Jun 2025
22 Jul 2025
19 Jun 2025
16 Jul 2025
3 Jul 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .