Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | ₹26.5 L Quoted ₹28.5 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹30.7 LRejected-AOC | ₹30.7 L | L2 | Rejected-AOC Other than lowest bidder |
| 3 | L3₹31.9 LRejected-AOC | ₹31.9 L | L3 | Rejected-AOC Other than lowest bidder |
| 4 | L4₹43.2 LRejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | ₹43.2 L | L4 | Rejected-AOC Other than lowest bidder |
| Sl No | Description | Qty | Unit | R B TRADERS L4 | Rajesh Agencies L1 | FATEH ENTERPRISES L2 | Ayushmat Contractors L3 |
|---|---|---|---|---|---|---|---|
| .01Schedule 'A' Section - I | |||||||
| 1.00 | Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed. | 120 | Cubic Metre | 180 ₹21,600 | 150 ₹18,000 | 200 ₹24,000 | 100 ₹12,000 |
| 2.00 | Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed. | 93 | Cubic Metre | 40 ₹3,720 | 100 ₹9,300 | 80 ₹7,440 | 25 ₹2,325 |
| 3.00 | Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed. | 27 | Cubic Metre | 50 ₹1,350 | 50 ₹1,350 | 80 ₹2,160 | 25 ₹675 |
| 4.00 | Dismantling and taking out old unserviceable worn out seamless carbon steel pipe line flanged type 150 mm bore including fittings complete with nuts, bolts, washers and gaskets etc and removing from the site complete all as specified and as directed by Engineer-in-charge. | 460 | Running Metre | 100 ₹46,000 | 40 ₹18,400 | 150 ₹69,000 | 70 ₹32,200 |
| 5.00 | Supplying, laying, jointing and testing hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 164.22 mm, with nominal wall thickness 7.11 mm and weight 28.26 Kg/ mtr, including short pieces as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- (i) Excavation, Earth work, PCC, seamless pipe fittings, MS flangeSupply & Fixinglanged joints shall measured and paid for separatly under relevant items.
(ii) Work will be carried out in piecemeal locations experienced based on break downs and weaker sections of existing rising/pumping mains as per site requirement complete all as directed.
(iii) Any other expenses including permision from state authorities are included under this item.
(iv) New pipes shall be laid first and old ones to be taken out later for smooth functioning of pumping lines.
(v) In the case of preparation of new header at pumping installation, all the alternate arrangements for uninterupted pumping shall be made by the contractor at no any additional cost. | 460 | Running Metre | 4,500 ₹20.7 L | 3,700 ₹17.0 L | 3,900 ₹17.9 L | 3,400 ₹15.6 L |
| 6.00 | Material & labour for MS Flange of ASA-150 standard suitable for 150mm dia bore seamless pipe comprising of inner dia 170.70 mm, outer dia 279.4 mm and thickness 25.00 mm, flange having 8 holes drilled to accomodate bolts of size not less than 19.00mm dia, PCS 241.3 complete for jointing with the existing pipes, duly welded with pipes/fittings bends properly to both the plain ends complete all as specified. and directed. | 154 | Each | 1,600 ₹2.5 L | 700 ₹1.1 L | 1,400 ₹2.2 L | 950 ₹1.5 L |
| 7.00 | Supply and fixing of joint for 150 mm nominal bore pipes, comprising one 5.0 mm thick steel-reinforced compressed asbestos fibre gasket, including 8 Nos M38 nuts and bolts (each bolt not less than 25 mm in diameter and 125 mm in length), and 2 Nos. 5 mm thick washers per joint, suitable for pipes/fittings/bends, complete all as specified and directed by the Engineer-in-Charge. | 77 | Each | 600 ₹46,200 | 150 ₹11,550 | 300 ₹23,100 | 150 ₹11,550 |
| 8.00 | Supply & Fixing strainer of size 150mm dia, with flanged ends on both sides suitably fitted with flanges welded with existing water supply pipeline of 150mm dia after removal of old unservicable without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. NOTE:- (i) MS flanges required to be welded to the existing pipe line/header shall be measured and paid seperately in relevant items. (ii) Joints and jointing materials, Nuts, bolts and washers of suitable size shall be provided and cost for the same deemed to be included in the quoted rate of the item itself. | 2 | Each | 4,500 ₹9,000 | 10,000 ₹20,000 | 4,275 ₹8,550 | 9,000 ₹18,000 |
| 9.00 | Material & labour for dismantling carefully the existing pumpsets complete by disconnecting their electrical connections and water supply connections, dismantling from foundation and shifting the same to place where directed for reinstalling/refixing both the pump and motor to be mounted on and including a common steel base frame of suitable size placed on PCC/RCC foundation incl grouting with suitable size nuts and bolts as per standard norms. All the necessary electric and water supply connections to be made including testing and commissioning after installing the pumpset to be carried out complete all as specifed and directed by Engineer-in-charge.
Note : (i) Both pump and motor mounted on and including a common steel base frame, shall be assembled and aligned properly by an authorized rep concern of the existing pumpset manufacturer. (ii) Reconnecting with the suction and delivery pipe lines incl all required materials and labour for any modification for proper fixing with the pumpsets shall be done all as specied and directed. (iii) Flanges, joints, pipes and other items required for connecting the water supply lines shall be measured under relevant items. (iv) All necessary electrical connections shall be made as per standards by an authorized electrician rep. (v) Necessary T&P for lifting,shifting the pumpsets shall be arranged by the contractor and cost for the entire job shall deemed to be included in the quoted rate of the item itself. (vi) Any minor parts and other items of the pumpsets if broken/damaged during shifting process shall be replaced and made good by the contractor himself. No extra payment shall be made in this regard. | 2 | Each Job | 95,000 ₹1.9 L | 8,000 ₹16,000 | 19,000 ₹38,000 | 1,07,300 ₹2.1 L |
Tender Value
₹40.9 L
EMD Value
₹81,700
Closing Date
8 Sept 2025, 6:00 pmClosed
Lt Col Jeethu Vijayan, Garrison Engineer, CEA
GARRISON ENGINEER KASAULI, DISTT SOLAN (HP) PIN 173204 PH 01792273107
REPAIR / REPLACEMENT OF WATER PUMPING MAINS OF VARIOUS SIZES FROM THAN VILLAGE TO HIGH LEVEL AND OTHER ALLIED WORKS UNDER GE KASAULI
2025_MES_725377_1
GEK-43/2025-26
Open Tender
Pipes and Pipe related activities
180 days
DAGSHAI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KASAULI
₹81,700
Yes
22 Dec 2025
9 Aug 2025
9 Sept 2025
9 Aug 2025
8 Sept 2025
26 Aug 2025
11 Aug 2025 - 14 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid