Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.2 LAccepted-AOC KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | 1 | Accepted-AOC L1 Accepted by competent authority | |
| 2 | 2₹1.4 L+₹22,895 (4.93%)Accepted-AOC | 2 | Accepted-AOC L2 Accepted by competent authority | |
| 3 | 3₹5.4 L+₹73,970 (15.9%)Rejected-Finance | 3 | Rejected-Finance work distribution between L1 and L2 |
Tender Value
₹5.8 L
EMD Value
₹11,626
Closing Date
30 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E), BSNL ED-II jaipur
Room No. 105, Ist Floor, Telephone Exchange Building, Durgapura, Jaipur
Rate Contract for call basis maintenance and shifting of Diesel Engine Alternator sets at various TE /BTS sites under BA Alwar.
2022_BSNL_122977_1
24/EE(E)/BSNL/ED-II/JP/2022-23
Open Tender
Electrical Works
Item Rate
180 days
Alwar
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (Cash), O/o GMTD BSNL, ALWAR
₹11,626
12 Sept 2022
20 Jul 2022
5 Aug 2022
20 Jul 2022
30 Jul 2022
20 Jul 2022
Amount
Pdg & Making of General Servicing of the following capacity E/A sets of different make and model installed at TE/BTS Sites comprising of following jobs i/c Fare and labour charge i/c complete checking of E/A Set after servicing and replacement of consumables for proper working as per manufacturer recommendations etc. complete as reqd. A) Cleaning the bowl inside as well as out side of fuel filter and oil filter , replacement of sealing ring. B) Cleaning the fuel strainer with clean diesel i/c pressure testing of fuel injector and it should be as per manufacturer recommendation. C) Cleaning the cooling system (Raditor) D) Replacement of Air cleaner element if reqd. E) Checking all belt Drives and retensioning the same etc as reqd. F) Remove the tapet cover and checking the valve clearance gap between rocker arm toe and valve stem end in cold condition as per manufacturer recommendation i/c replacement of tappet cover gasket if reqd. etc. as reqd. G) Cleaning the entire E/A Set (inclusive of fins, blower and block). i.e. oil & grease etc. H) Cleaning of diesel tank I) Checking of charging alternaror, starter self and engine control panel connection, gauges and indicators and its fuction. J) Checking and setting of fuel supply and time as per manufacturer recommendations. NOTE: After servicing the set, a trial test also be carried out by the firm for 30 minutes and check its performance & submitt the readings of out put voltage, current (for each phase) and frequency, LOP, RPM, Hr Meter Reading with working condition status report etc. in Service Report. This item shall be paid only after submission of desired report duly verified by concerned telecom authorities.
up to 20 KVA DEA set
Above 20 KVA and up to 50 KVA
Replacement of the following Parts / Items in existing Various capacity E/A sets up to 50 KVA of different make ,model I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd.( Note- Make and Model as per manufacturer recommendation )
Lub Oil Filter Element
Diesel Filter Kit
Radiator Coolent Pre Mix ready to use (Make -kirloskar /HP/Fleetguard)
Lubricating Oil Multi Grade ( 20W40)( Make -KOIL /Servo/HP/volvoline )
Steel wire braided fuel pipe with benjo bolts & washer
Battery Leads Red & Black Standard Length & Size suitable up to 180AH battery i/c brass terminals
Battery Lead brass terminals/copper Lugs
Replacement of Solid state SMPS or SCR based battery chargers suitable up to 12v, 180 AH Battery in existing E/A Set AMF / Manual Control Panels I/c dismentling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. ( Make -Technika, National)
Servicing of the self starter of DEA set i/c dismantling, cleaning of self with petrol, greasing and oiling of bearing i/c testing etc complete as reqd. Note-This item exclude the cost of parts associated with Self Starter.
Repairing of following faulty items in the self starter of DEA set i/c dismantling of unserviceable/ defective items, fixing with new one i/c connection, testing etc complete as reqd. [Note: Labour charges already covered in item No 4]
Carbon bush set
Solenoid coil
Bendex Gear
Servicing of Battery Charging Alternator / Dynamo i/c Dismantling of equipment, cleaning, greasing and oiling of bearings and other parts etc. complete as required. Note-This item exclude the cost of parts associated with Battery Charging Alternator / Dynamo.
Repairing of following faulty items in Battery Charging Alternator / Dynamo of DEA set DEA set i/c dismantling of unserviceable/ defective items, fixing with new one i/c connection, testing etc complete as reqd. [Note: Labour charges already covered in item No 06]
Rectifier assembly
Carbon brush set
Supplying and fixing of 12 Volts Maintenance free Battery of following capacity for E/A sets, i/c initial charging, battery terminals, transportation, testing, commissioning etc. complete as reqd.(Note: Battery should be of atleast 24 months warranty (18 month full replacement +6 month prorata basis). Manufacturer warranty card with dealer stamp shall be submitted along with new battery). (Make:- Exide / Amron)
Transportation charges for alternator up to 50 KVA capacity from Site to Workshop & back after repairing i/c Dismantling, loading, unloading, transportation, safe Handling & Commissioning after repairing etc. complete as reqd.
Rewinding of following parts of existing alternator up to 20 KVA with suitable size copper enamelled wire including providing of insulation of appropriate class, varnishing, assembling i/c testing etc complete as required.
Main Stator winding
Main Rotor winding
Exciter Stator winding
Exciter Rotor winding
Replacement / Repairing of faulty items in the existing Alternator up to 50 KVA Alternator at TE / BTS Sites i/c dismantling the faulty, replacement by new one i/c fixing, testing, commissioning etc. complete as reqd.
AVR Make National /crompton/kirloskar
Power Diode for Rotating Rectifier Assembly
Supplying of following size of pvc insulated pvc sheathed 1.1 kv grade Aluminium conductor armoured cable confirming to relevant IS-Specification etc complete as reqd. (Make -Polycab/havells/finolex )
2 x 6 Sqmm.
2 x 16 Sqmm.
4 x 16 Sqmm.
3.5 x35 Sqmm.
Laying of one no. PVC insulated & PVC sheathed/XLPE power cable of 1.1 KV grade of following size. Direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
Up to 35 sq. mm
Laying of one no. PVC insulated PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/Hume/ Stoneware/Metal pipe as reqd.
Up to 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade of following size on surface as required.
Up to 35 sq. mm (clamped with 1mm thick saddle)
S/F of 63 amps four pole on load change over switch in steel enclosure with side handle operation capable of working 415/500 V ,AC 23 Duty i/c drilling hole on the board, making connection, earthing the body etc. as reqd. (Make:Havells / HPL / Standard)
S/F 63 Amps Heavy duty TPN Switch fuse unit with HRC fuses in steel enclosure with side handle operation capable of working 415/500 V AC 23 Duty i/c drilling hole on the board, making connection, earthing the body etc. as reqd. (Make:Havells / HPL / Standard)
S/F of 100 amps four pole on load change over switch in steel enclosure with side handle operation capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.(Make:Havells / HPL / Standard)
S/F 100 Amps Heavy duty TPN Switch fuse unit with HRC fuses in steel enclosure with side handle operation capable of working 415/500 V i/c drilling hole on the board, making connection, earthing the body etc. as reqd.(Make:Havells / HPL / Standard)
Dismentling of existing silent canopy /open type DEA Set of capacity up to 30 KVA of different Make & model with Manual /AMF control panel with Power and control cable , Silencer and exaust pipe , diesel tank , battery and associated fuel line and all other electrical acessories etc complete at TE/BTS site i/c making good the damage etc as reqd.
Shifting of existing dismentalled Silent canopy/open type DEA Set of capacity up to 30 KVA of different make and model a/w all acessories like AMF Manual control panel with power and control cable , silencer ,exaust pipe , diesel tank and fuel line ,battery and all other electrical acessories etc complete from One TE /BTS /BSNL Campus to other TE /BTS/BSNL Campus for distance up to 100 KM i/c loading at TE /BTS/BSNL campus and transportation to other TE/BTS Site and unloading the same at TE/BTS site on existing CC foundation etc as reqd. Note -Safe loading and transportation and unloading will be responsibility of agency ,any damange during loading ,transit and unloading will be making good ny agency without any extra cost .
Installation, testing , commissioning of Existing Silent canopy /open type Diesel Engine Alternator set of capacity up to 30 KVA of different make & model on existing CC foundation with all acessories like Cubical type manual /AMF control panel i/c fixing of Silencer ,exhaust pipe , fuel tank , fuel line connections, control wiring from panel to engine i/c cutting, jointing, welding of flanges (if reqd) , nuts, bolts , i/c two coat silver paint on exhaust pipe and silencer i/c making good the damage etc. i/c One hour testing of DG set on exchange load etc as reqd (Note -All consumable like diesel will be arrange by the ageny for comissioning purpose )
Tranportation and shifting Charges of Trolley mounted DEA set of capacity upto 50 KVA alongwith canopy, control panel, exhaust pipe, silencer, fuel tank, AVM pads, power cable and all other accessories for approximate average distance of 150 Km subject to variation in either side form sub division HQ i/c toeing arrangement with help of jeep / tractor I/c making connection with existing cable at shifted site to restore the supply immediately including testing on exchnage / BTS Load for 30 Minutes with the help of required consumables i.e. fuel, lube oil and arrangement of starting battery etc. complete as required.
Visit charges to detect and attend the fault of Electromechanical Services on call basis / complaint basis of TE buildings / BTS, attending the minor faults involving petty nature material ( i.e. insulation tap / small pieces of wire etc. ) and submission of detailed report for all type of fault to Engineering -In-charge etc complete as reqd. (Note:- Supply & Fixing Charges of any material required shall be paid extra) Remarks :1. The number of building (site) should be clubbed to attend the fault (atleast two sites to be clubbed). 2. The Visit Charge shall not be paid if the payment of schedule items made more than Rs.2500 for that particular building (site) of the individual agreement.
Witn in Municipal area of Alwar City
Outside the Municipal area of Alwar City
S/F of following MS items to be used for for frame work and adopter box I/c Cutting , welding painting etc. as required.
50mmx50mmx5mm Angle Iron
35mm X 35mm X 5mm Angle iron
Manohar Electricals
Singhal Electricals, Jaipur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .