Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.7 LAccepted-AOC 29 7 KACHERI ROAD NEAR DISTRICT HOSPITAL PRATAPGARH PRATAPGARH UTTAR PRADESH 230001 | PRATAPGARH | UTTAR PRADESH | 230001 | 1 | Accepted-AOC Due to L-1 and credit | |
| 2 | 2₹21.8 L+₹1.9 L (9.75%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹21.8 L+₹2.0 L (9.83%)Rejected-Finance HNO 52B LAXMI PLACE PHASE II DEORI ROAD NEAR MOHANDEV SCHOOL UKHARA ROAD AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹22.6 L+₹2.7 L (13.6%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹24.6 L+₹4.8 L (24.0%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR TO CERTAIN B/R COMPREHENSIVE REPAIR WORKS TO SMQS, OMQS AND OTM ACCN UNDER AGE BR-II OF GE (AF) ADM AREA AT AF STN AGRA.
2023_MES_632310_1
8000-2109/E8
Open Tender
Civil Works
Item Rate
180 days
AF Station Agra
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE AF Adm Area Agra
₹50,000
Yes
19 Feb 2024
12 Dec 2023
15 Jan 2024
12 Dec 2023
8 Jan 2024
27 Dec 2023
Amount
Cleaning the roof surface, removal of plants/trees/shrubs from roof top/sides, external walls of building, chajjas, wall junctions of rain water/ CI soil/ Waste pipe junctions including taking out the roots entered in wall/slab surface and making good the disturbed surface using cement concrete 1:2:4 type B-0 using 12.5 mm thick stone aggregate or with cement mortar (1:2) to match with the existing surface, including necessary scaffolding/ staging upto height of 15 m from the ground level complete all as directed.
M&L cement concrete type B-0 (1:2:4) (12.5mm graded stone aggregate) as in roof padding for levelling / maintaining slope, benching, roof kerbs etc. iincluding demolition of existing PCC complete all as specified and directed.
M&L for screed bed or rendering 10 mm thick in averaging on RCC roof slab/parapet in cement mortar 1:4 mixed with and including integral water proofing comound @ 2 % by wt of cement complete all as specified and directed. (Rate of Water proofing compound shall deemed to be included under this item).
M&L for provn of roof treatment with polymeric water proofing membrane all as given below:- (a) Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc. and removing the material retrieved as directed. (b) Applying a coat of bituminous primer @ 0.30 Iit/sqm on prepared surface and allowed to dry. (c) Applying a coat of hot blown bitumen 85/25 conforming to IS-702 @ 1.20 Kg/Sqm (d) Applying and laying 3mm thick APP membrane having non woven polyester matt at core and covered with high quality polymeric asphaltic protected thermo fusible HMHDPE film on both sides with over laps 10 cm and 15 cm at longitudinal and transverse direction respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and groove sealed with cement mortar 1:3. Note : (i) Treatment shall be done through authorised representative of manufacturer.
M&L for 20 mm thick PCC tiles machine pressed factory made of size 300 mm x 300 mm as per IS-1237-1980 laid over and including 15 mm thick screed in cement mortar 1:4 mixed with and including liquid water proofing comound @ 200 ml per bag of cement, grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement complete all as specified and directed. (Rate of Water proofing compound and crude oil shall deemed to be included under this item).
M&L for applying one coats of aluminium paint on membrane @ 0.10 Kg/Sqm complete all as specified and directed.
M&L for applying three or more coats of liquid polymer paint coating on concrete/ plastered surface of floor/ beam/ roof etc. applied all as per manufacturer instructions and all as directed. Make:- Sikka/Fosroc/ Dr Fixit/ Brush bond
M&L for cutting grooves in brick wall/ parapet wall, 75mm wide and 65mm deep and shaping horizontal face of groove for inserting APP membrane and sealed with cement mortar 1:3 complete all as specified and directed.
Taking down and refixing of 20 mm bore GI Steel tubings including new or old fittings and cutting chases of wall wherever required and making good the surface to match the existing complete all as specified and directed.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings including cutting chases of wall wherever required and making good the surface to match the existing or laid in floors and testing including taking down existing GI tubing complete all as specified and directed.
Taking down and refixing of 25 mm bore GI Steel tubings including new or old fittings and cutting chases of wall wherever required and making good the surface to match the existing complete all as specified and directed.
Supply, fixing, laying & testing 25 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings including cutting chases of wall wherever required and making good the surface to match the existing or laid in floors and testing including taking down existing GI tubing complete all as specified and directed.
Disconnecting existing water tank of capacity 500 ltr, setting aside (or lowering of required) for repairs of roof (incl tank nipple) etc. and hosting, reconnecting and refixing in position complete all as specified and directed.
Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes exc 250 & n exc 500 ltrs including removing stored water and cleaning with chlorine water and writing with enamel paint TANK CLEANED ON _______ (Date) complete all as specified and directed.
S&F in repair tripple layer rotational moulded polyethylene water storage tanks 500 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including ball valve 20 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and directed.
Disconnecting existing water tank of capacity 1000 ltr, setting aside (or lowering of required) for repairs of roof (incl tank nipple) etc. and hosting, reconnecting and refixing in position complete all as specified and directed.
Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes exc 500 & n exc 1000 ltrs including removing stored water and cleaning with chlorine water and writing with enamel paint TANK CLEANED ON _______ (Date) complete all as specified and directed.
S&F in repair tripple layer rotational moulded polyethylene water storage tanks 1000 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position with and including ball valve 20 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and directed.
S&F in repair 20 mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and fixed to walls with clamps complete all as specified and directed.
S&F PVC(SWR) bends 110 mm bore any radius complete all as specified and directed.
M&L for two coats of epoxy resin/polymer modified cementaticious coating e.g “Brush Bond” of “Forsroc” or equivalent on concrete/plastered surface of wall/floor/beams etc. applied all as per manufacturer instructions and all as directed.
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) for rough finished surface complete all as specified and as directed.
M&L RCC 1:1.5:3 type A-1 using 20 mm graded stone aggregate as in slab supported on wall, beams and coloumns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and similar works including demolition of existing RCC complete all as specified and directed.
M&L for light shade vitrified ceramic tiles 10 mm thick(square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for light shade vitrified ceramic tiles 10 mm thick polished on vertical surface such as skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including 10 mm thick rendering in cement mortar 1:3 and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick joint less (square or rectangular) on vertical surface such as skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including 10 mm thick rendering in cement mortar 1:3 and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for 75 mm thick cement concrete type C1 1:3:6 (using 20 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and fair including forming construction (dummy) joints 6 mm wide & 10 mm deep and filled with filler at an interval not exceeding 3 metre and at change of direction including demolition of existing plinth protection complete all as specified and directed.
M&L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in flooring finished even and smooth using extra cement including demolition of cement concrete as in floor complete all as specified and directed.
M&L for 25 mm (average) thick cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in sunken floor for correction of slope/levelling etc. demolition of cement concrete as in floor complete all as specified and directed.
M&L for machine cut kota stone slab of size not less than 550 x 550 mm (except where lesser size required) as in flooring or in trades of steps 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing, rounding of edges and mirror finish polishing with & including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes including demolition of existing stone complete all as specified and directed
M&L for machine cut kota stone 18 to 22 mm thick as in steps, risers, skirting, dado etc., bedded and jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of the stone including grinding, rubbing and mirror polishing with & including rendering 15 mm thick in cement mortar 1:4 finished rough to fix stone and taking down existing stone complete all as specified and directed.
M/s Pooran Singh and Company
SHRI RADHAYSHYAM JHA
M/s Shiv Builders
Balaji Associate
M/s K S Builders
Asha Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .