Project Manager
PROJECT MANAGER, UNIT-10,Udayog Kunj Road, Dada Nagar, Kanpur
Construction of Repair and Modification works of Laboratories at U.P.T.T.I. District-Kanpur
2020_UPPRC_510350_6
12/PCL/PM-10/2020-21
Open Tender
Civil Works
Item Rate
120 days
Kanpur
Construction of Repair and Modification works of Laboratories at U.P.T.T.I. District-Kanpur
2 documents required · 2 mandatory
₹2,360
Project Manager, Unit-10
₹32,000
19 Oct 2020
3 Oct 2020
12 Oct 2020
3 Oct 2020
12 Oct 2020
3 Oct 2020
30 days
Amount
Dismantling existing plaster including disposal of refuse as directed by Engineer-in-charge within a distance of 60 meters.(200feet)
Dismantling existing plaster including disposal of refuse as directed by Engineer-in-charge within a distance of 60 meters.(200feet)
Dismantling existing plaster including disposal of refuse as directed by Engineer-in-charge within a distance of 60 meters.(200feet)
Dismantling cement concrete or granolithic floors including base concrete and including stacking of dismantled materials as directed by Engineer-in-charge within a distance of 60 meters.(200feet)
Dismantling doors & windows including chaukhats with hold fast and including stacking of dismantled materials as directed by Engineer-in-charge within a distance of 60 meters.(200feet)
Dismantling doors & windows leaves including stacking of dismantled materials as directed by Engineer-in-charge within a distance of 60 meters.(200feet)
Scraping old white or colour wash including disposal of refuse as directed by Engineer-in-charge within a distance of 60 meters.(200feet)
Dismantling & Removal of old existing internal electrification & plumbing works.
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (1)1 cement : 6 fine sand.
12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand
12 mm cement plaster in ceiling with 1 cement : 4 coarse sand
Providing and laying of 8 to 10 mm thick ivory or light shade vitrified tiles of 600 mm x600 mm size in flooring or skirt ing laid with 1:3 cement mortar (1 cement :3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T &P required for proper completion of work.
Providing and laying of 8 to 10 mm thick ivory or light shade vitrified tiles of 600 mm x600 mm size in flooring or skirt ing laid with 1:3 cement mortar (1 cement :3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T &P required for proper completion of work.
Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in floors.
Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
Providing & fixing of door / windows grill.
Providing & fixing of hold fast for chaukhats of doors and windows.
Z-Section steel windows
Fixing panes of glass with atul or equivalent I.S.I. marked quality putty, brads and springs complete. (a) 4 mm thick.
Fixing of Door, windows / ventilators chaukhats in position.
(b) Door chaukhats
(b) Window chaukhats
(b) Ventilator chaukhats
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth including cost of material, labour, T & P etc. complete.
Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.
Finishing walls with two coat of Acrylic Smooth exterior paint of best quality including supply of all materials, labour tools and plants etc. required for proper completion of the work.
Providing & fixing ISI marked flush door shutters conforming to IS: 2202 (Part-I) non-decorative type, core of block board construction with frame of Ist class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
(a) 35mm thick
Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc.
Same as above but wooden painting
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete
Supply and fixing of anodised /alluminium door having 2 mm thick alluminium section (powder coated) excluding coating & an average coating of 20 micron fully glazed made of alluminium door tube size 83.5x 44.65 mm as vertical member & 114.00 x 44.45 mm size tube in bottom and horizontal members door chaukhat should be of alluminium tublar vertical with two openable shutters. The rate will include cost of material fixtures, 5 mm glass, locks, screw necessary beeding & excluding cost of floor spring, handles if required for proper completion of work as per direction of Engineer I/C.
Dismantling of old wooden platform & racks
Disposal of malwa including loading & unloading Refused material within distance of 8.00 Km from site.
SUBHEAD I- WIRING POINTS
Wiring points for light with 1 sqmm.FRLSH PVC insulated single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as
earth continuity wire and piano type switch etc. complete in all respects.
Same as item No.(1) but for fan and light duty exhaust fan.
Same as item No.(1) but for 5 Amp plug point
Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.
Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor
cable as earth contunity wire etc. complete in all respects.
Supply and wiring of submain 4 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 32mm dia PVC conduit along with two numbers 6 sqmm FRLSH PVC insulated multistranded copper conductor
cable as earth contunity wire etc. complete in all respects.
Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points.
Addition for light / fan points with modular type switch in place of piono type switch.
Addition for HPSV/Exhaust Fan points with modular type switch in place of piono type switch.
Addition for plug points with modular type switch in place of piono type switch.
SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light complete including tube etc on surface complete in all respect.
SUBHEAD III-DISTIBUTION BOARD
Supply and fixing of flush/surface mounting distribution boards without MCB with additional metal door complete in all respects.(CAT:B)
4 Way TPN
6 Way TPN
Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required. Cat A
Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge.CAT A
32 Amp. 4P MCB (10 KA)
40 Amp. 4 Pole MCB
Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
Supply and fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket switch on concealed M.S. box of including supply of all material, labour T&P etc. required for proper completion of work.
SUBHEAD IV-EARTHING SYSTEM
Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I.
pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in
all respects.
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
Supply and fixing one number 8 SWG G.I. wire in 15 mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand labour, T&P other material required for proper completion of the other work as directed at site
SUBHEAD V-CABLES
Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the
cable run shall be fixed on M.S. clamps etc. of suitable size.
185 sqmm 3.5 core
70 sqmm 3.5 core
Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
185 sqmm 3.5 core
70 sqmm 3.5 core
Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
SUBHEAD VII-MISCELLANEOUS
Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required
Supplying of Heavy duty capacitor start single phase ISI marked 450 mm dia Single Phase Industrial duty (Propeller Type Exhaust Ventilating Fans) 4 pole 1500 rpm exhaust fan having power consumption of 360 w or below and airflow of 6800 CMH and noise level below 65 dB but without regulator complete with louver, bird screen etc. and with 3 core flexible wire lead as required. .
GST extra as applicable
Prerna Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .