Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.7 L+₹1.0 L (4.03%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹27.0 L+₹1.3 L (5.10%)Rejected-Finance KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance HIGHER | |
| 4 | Rejected-Technical SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | - | Rejected-Technical No, WLR QE Sep 23 CEWC Srl No 31 issued on 29 Feb2024 | |
| 5 | Rejected-Technical RIDMALSAR PUROHITAN BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | - | Rejected-Technical Not Recommended, being not enlisted in category a(ii) |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN-143001
REPAIR/REPLACEMENT OF ASBESTOS CEMENT PIPE BY DUCTILE IRION PIPE INCLUDING FITTINGS AT OLD AMRITSAR CANTT
2023_MES_623408_3
GE/ASR-65/2023-24
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS E CATEGORY a ii
8 documents required · 8 mandatory
₹500
GE Amritsar
₹50,000
18 Sept 2024
7 Mar 2024
29 Mar 2024
7 Mar 2024
28 Mar 2024
15 Mar 2024
Amount
Material and Labour for cutting existing AC/CI/DI water mains of 150mm/200mm dia (in position) for insertion of new tees, branch connections include for turning water off and on and draining and refilling ; Complete all as specifed and directed by Engineer-in-charge. NOTE: Cost of CI/DI fittings shall be measured and paid for separately under relevant item.
All as per ser item No. 01 above but for CI/DI water mains of 100mm dia ; Complete all as specifed and directed by Engineer-in-charge.
Material & labour for DI/CI fittings conforming to IS:9523 for flanged/spigot socketed type DI pieces special any type upto 200mm dia bore such as bends (any type of radious and angle) tapers any type (straight bend increasing, decreasing or double socket etc) Tee pieces, single branch, 'Y' junctions, doubled branch, cross (all sockets and sockets & spigots), collars, caps and plugs ; Complete all as specifed and directed by Engineer-in-charge. Make: ELECTRO-STEEL/ LANCO, JINDAL, TATA METALIKS, RASHMI, KESORAM, TATA KUBOTA,ELECTROTHERM
Supply, lay and testing Ductile Iron pipes pressure with spigot & socket ends of 200mm bore class K-9 centrifugally cast conforming to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and including tyton rubber gasket push-on joints as required at site complete including dismantling & taking out old UNSV asbestos cement pipe or PVC pipe any size from trenches ; Complete all as specifed and directed by Engineer-in-charge. Make: ELECTRO-STEEL/ LANCO, JINDAL, TATA METALIKS, RASHMI, KESORAM, TATA KUBOTA,ELECTROTHERM NOTE FOR SER ITEM NO. 04 to 06: (a) The cost of DI fitting shall be measured and paid separately under relevant item. (b) Excavation & other earth work will be measured and paid separately under relevant items.
All as per ser item No. 04 above but for DI pipe of 150mm dia ; Complete all as specifed and directed by Engineer-in-charge.
All as per ser item No. 04 above but for DI pipe of 100mm dia ; Complete all as specifed and directed by Engineer-in-charge.
Material and Labour for cutting existing GI water mains of 80mm bore (in position) for insertion of new tees, branch connections include for turning water off and on and draining and refilling including S&F GI fittings ; Complete all as specifed and directed by Engineer-in-charge.
Supply & laying/fixing galvanised steel water tubes of size 80mm dia, medium grade with screwed socket joint together with and including all GI fittings such as bends, elbows, short piece connections, backnuts, caps plugs and unions etc laid in trenches/fixed on walls/laid on floors including taking down old UNSV AC/PVC pipes from site ; Complete all as specifed and directed by Engineer-in-charge. Make: ELECTRO-STEEL/ LANCO, JINDAL, TATA METALIKS, RASHMI, KESORAM, TATA KUBOTA,ELECTROTHERM NOTE: Excavation and earth work will be meaured and paid separately under relevant items.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipe line and getting out in soft/loose soil and in road cutting ; Complete all as specifed and directed by Engineer-in-charge.
Returning, filling in excavated material/soil including spreading, leveling, watering and well ramming in layers n exc 25cm in soil ; Complete all as specifed and directed by Engineer-in-charge.
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point ; Complete all as specifed and directed by Engineer-in-charge.
Cutting hard standing/road not exceeding 1.5m deep and making good with and including PCC (1:3:6) type C2 (using 40mm graded aggregates) and removal of debris and making the damaged areas uniform as per existing ; Complete all as specifed and directed by Engineer-in-charge.
Material and Labour for repairing of leakages CI/DI pipes of size 100mm to 200 mm bore by replacing the Tees, bends, sockets and providing the other materials required at site such as lead joint, tyton joint etc., to complete the job including excavation and other earth work, returning, refilling & removal of surplus soil and as described in notes below ; Complete all as specifed and directed by Engineer-in-charge.. NOTE FOR SER ITEM NO. 13 TO 16: (a) The cost of CI/DI fittings will be measured & paid seperately under relevant item, whereas cost of lead joint/tyton rubber joint shall be included in the quoted rate (b) One supervisor will report to the JE in charge on daily basis along with complaint register, complaint slip in duplicate which shall also be arranged by the contractor without any extra cost for recording/monitoring of water supply complaints. (c) All minor complaints shall be completed within 24 hours and all major complaints shall be completed within 48 hours (d) A penalty of Rs. 200/per complaint will be levied on the contractor for all the pending complaints beyond the completion period as specified in S.No (c) above. (e) Contractor shall arrange at his own expense the security passes for himself, his supervisor and his plumbers and labours as per stn security policy.
Material and Labour for repairing of leakages GI pipe of size 80 mm bore by replacing the Tees, bends, sockets and providing the other materials required to complete the job including excavation and other earth work, returning, refilling & removal of surplus soil and as described in notes below ; Complete all as specifed and directed by Engineer-in-charge.
All as per ser item No. 14 above but for GI pipe of size 40 to 50 mm bore ; Complete all as specifed and directed by Engineer-in-charge.
All as per ser item No. 14 above but for GI pipe of size 15 to 25 mm bore ; Complete all as specifed and directed by Engineer-in-charge.
Dismantling and taking down the unserviceable Sluice valves any size/any class, in position by opening of bolts, nuts & washers; checking, repairing of water leakage from sluice valves, air release valve, NRV etc., any sizes in different locations under GE Amritsar including replacement of required size of gland packing, worn out synthetic ball, etc. and making leak proof, reassembling the same after repair and refixing the same in its original location including cleaning the valve chamber of any dimensions by removing water, bushes and any other unwanted materials ; Complete all as specifed and directed by Engineer-in-charge.. NOTE: Cost of gland packing, synthetic ball will be included in the quoted rate
Supply and Fixing in replacement of MS plain black sheet of 1.60mm thick in wall cladding, steel gates and similar work, for valve chamber cover cut to size, holes punched, including round headed screws, clout nails or riveting, welding and fixed to and including steel framing of required size with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc., ; Complete all as specifed and directed by Engineer-in-charge.
Material and Labour for painting one coat of black bituminous/aluminum paint on steel or iron surface of any description, not exc. 10cm width/girth including preparation of old painted surface (i.e. cross arms, bracings, angle iron, clamps etc.) by scrubbing with emery paper around the Pump House Area ; Complete all as specifed and directed by Engineer-in-charge. NOTE: Cost of Aluminium/black bituminous paint will be measure and paid as Supply only under relevant items.
Supply only Black bituminous paint ; Complete all as specifed and directed by Engineer-in-charge.
Material and labour for construction of brick masonary pits (230mm thick wall) of 900x600x1000mm internal dimension (bottom PCC floor of the pit should be minimum 30cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:4:8) type D2 using 15cms thick with 20mm stone aggregate for foundation, brick wall with sub class 'B' bricks built in CM 1:6, inner and exposed surfaces and bottom floor of the pit should be plastered in cement mortar (1:4) 15mm thick, PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping. The sluice valve and other fittings should be housed in center of the pit. The vertices of the pit should in right angle and chamfered. The top cover of the pit will be made out of MS sheet 3mm thick with angle iron frame made out of MS angle 50mmx50mmx6mm with galvanized steel hinges two Nos. and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide including necessary excavation and earth work in any type of soil complete all as shown in Drg No. CEJZ/TD-1060 Sheet 1/3 to 3/3.
All as per ser item No. 21 above but of valve pit of internal dimension 450mm x 450mm x 600mm ; Complete all as specifed and directed by Engineer-in-charge.
Material and labour for Cement concrete in foundation , filling and mass concrete type C-2 (with 40 mm graded stone aggregate ) for anchor blocks or ; Complete all as specifed and directed by Engineer-in-charge.
Supply and Fixing in replacement Sluice valve 150 mm dia ISI marked (IS -14846) with SS spindle and wedge nut , nut bolt GI and rubber gaskets ; Complete all as specifed and directed by Engineer-in-charge
M/s Vijay Construction Co.
ss enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .