Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹23.4 L+₹1.0 L (4.57%)Rejected-Finance NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹23.5 L+₹1.1 L (4.96%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Not lowest |
Tender Value
₹27.7 L
EMD Value
₹55,340
Closing Date
19 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT-10
PROVN OF WORKS SERVICES FOR DDSP AND PROVN OF STORAGE ROOM AT CAMP AREA AF STN PALAM UNDER GE (AF) PALAM DELHI CANTT-10
2023_MES_619914_1
GENP-52/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹55,340
Yes
16 Dec 2023
21 Sept 2023
20 Oct 2023
21 Sept 2023
19 Oct 2023
6 Oct 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/ loose soil all as specified.
Removal of excavated material /soil not exceeding 100 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, mass concrete and filiings complete all as specified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified.
M&L for reinforced cement concrete (M-25 design mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc basement slabs,under-reamed piles and mass concrete complete all as specified.
Form work to side of columns and simillar work for rough finished surfaces of concrete complete all as specified.
M&L for reinforcement cement concrete (M-25 Design Mix) as in columns, pillars, piers, posts and struts all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete all as specified.
M&L for reinforcement cement concrete (M-25 Design Mix) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping for rough finished surfaces of concrete complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work not exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M&L for reinforcement cement concrete (M-25 Design Mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete complete all as specified.
M&L for reinforcement cement concrete (M-25 Design Mix) as in chajjas complete all as specified.
S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
All as per item No 16 above but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L for brick work with sub class 'B' using old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified.
M&L for brick work with sub class 'B' using old size bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified.
M&L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing even and smooth surface without using extra cement on wall complete all as specified .
M&L for 15 mm thick cement plaster in two layers i.e first layer 10mm thick in cement mortar 1:4 and second layer 5mm thick in cement mortar 1:4 mixed with WPC as per manufacturer's instruction on fair faces of brick work or concrete surfaces including finishing even and fair surface without using extra cement on wall complete all as specified. (Note : WPC shall be measured & paid separately as supply only).
Suppy only integral water proofing liquid compound all as specified.
M&L for 5 mm thick rendering in cement mortar 1:4 on concrete surfaces including finishing even and smooth surface without using extra cement in ceiling complete all as specified .
M&L for two coats of oil bound distemper over a coat of primer using roller and including necessary scaffolding etc including preparation of newly plastered surfaces on wall complete all as specified.
M&L for two coats of oil bound distemper over a coat of primer using roller and including necessary scaffolding etc including preparation of newly plastered surfaces in ceiling complete all as specified.
M&L for prepration of newly plastered surface and finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade with two coats applied @ 1.43 ltr/ 10 Sqm ( Make : wall mista of berger paint or its equivalent in Asian paint, Nerolac etc having three years of performance warranty) over priming coat of exterior primer applied @ 2.20 kg/10 Sqm of same make complete all as specified.
M&L for hardcore of broken stone or boulders gauge not exc. 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface as in plinth protection/path and similar works.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base to floors complete all as specified.
M&L for 25 mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub base to floors complete all as specified.
M&L for digital ceramic tiles coloured of size 300mm x 600mm x 7mm to 8mm thick as on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tile over and including 10mm thick cement plaster in cement mortar 1:4 complete all as specified.
S&F for 10mm thick vitrified tiles 'light shade' (square/rectanglar) polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile laid over 15mm thick screed bed in cement mortar 1:6 complete all as specified.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in landings, cover slabs (for man holes/ drain etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified.
M&L for 20 mm thick granite slab (of any type) work (table rubbed and polished) jet black colour in steps, jambs, pillars, window-cills, cooking platforms, sink/ WHB platform including cutting the slab to oval shape to accomdate the same and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding/rounding to edges and laid over and including 15mm thick screed bed in cement mortar 1:4 complete as specified.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 20mm graded stone aggregate as in plinth protection including finished even and smooth surface without using extra cement and making joints 12 mm wide to the full depth of concrete at every 3 metres interval and at every change of direction and filling the same with & including bitumen 85/25 and sand in the proportion of (1:3 ) by weight complete all as specified.
S&F for factory made PVC door frame of size 50mmx47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawing.
S&F for factory made Solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC shets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC shet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame at site as per specification and drawing.
S&F for butt hinges, stainless steel, ISI Marked 100mm size complete all as specified.
S&F for extruded aluminium alloy handles, fabricated type anodised of 125mm long complete all as specifed.
S&F for aluminium anodised barrel tower bolts of extruded section and fixed of 100mm long complete all as specifed.
S&F for second class hardwood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified.
S&F for 40 mm thick factory made flush shutters, solid core construction with block board core and plywood face panels covered with decorative face veneers both side with lipping/frame to match complete all as specified.
S&F for brass tower bolts of extruded section of size 150 mm length all as specified.
S&F for 250 mm long brass handles complete all as specified.
S&F for 250mm brass sliding door, bolts with hasp and staple ( bolt type ) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section all as specified.
M&L for 4 mm thick frosted sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each panes complete all as specifed.
S&F for aluminium colour powder coated (coating not less than 50 Micron) frame for doors, windows, ventilators, partations and shutters with one or more rebates including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified.
S&F for EWC couple closet wall mounting with 10 Ltr capacity vitreous china flushin cistern including jointing including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel CP or aluminimised hinging device complete
S&F for hand shower (Health faucet) with 1.00 metre long easy flex tube in chrome finish & wall hook Cat Pt No ALD-CHR-565 of JAQUAR or its equivalent in MARC/ KOHLER as approved by the GE.
S&F for vitreous china, counter wash hand basin, oval shape of size 420mm x 420mm x135 mm white fixed on granite counter down slab including brass chromium plated full threaded waste coupling with grating 32mm dia pvc waste pipe complete all as specified. (Note: Granite slab, RCC platform, brick wall support etc shall be measured and paid separately)
S&F for PVC connection 15mm size, 600mm long with PTMP nuts both side complete all as specifed.
S&F for brass CP towel rail 600 mm long of make : Prayag Cat No BA-01 or its equivalent in Jaquar/ Marc/ Kohler as approved by the GE fixed with and including chromium plated screws on walls complete all as specified.
S&F for 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layers, hoisted and fixed in position all as specified in SSR Part I.
S&F for 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layers, hoisted and fixed in position all as specified in SSR Part I.
S&F for ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe of size 20mm dia complete all as specifed.
S& F 15mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified.
S&F for bib tap, fancy type, chromium plated, with crunch or butterfly handle screwed down,screwed for iron pipe or for brass ferrule and fixed of 15mm bore complete all as specifed.
S&F for 15mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specifed.
S&F for 15mm dia stop cock, fancy type, chromium plated, screwed down, high presure with cruntch or butterfly handle screwed both ends for iron pipe complete all as specifed.
M&L for 15mm GI tubing 'Medium grade' with all fiting and fixed complete to wall and celing or laid in floor of floors complete all as specifed.
All as per item No 59 above but 20mm bore.
M&L for 75mm bore cast iron Nahani trap/floor trap with CP grating including jointing with cement joint to waste pipe fixed in cement concrete type B-1(1:2:4) complete all as specified.
S&F for Cast Iron trap `P' 100mm bore complete all as specified.
S&F for 100mm bore cast iron (sand cast) soil, waste and vent pipe in any length with or without ears including suitable clamps after every one mtr of interval with cement joints fixed to wall complete all as specified.
S&F for 75mm bore cast iron (sand cast) soil, waste and vent pipe in any length with or without ears including suitable clamps after every one mtr of interval with cement joints fixed to wall complete all as specified.
S&F for 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door.
S&F for 100mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door.
S&F for 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door.
S&F for cast iron cowl 100 mm bore.
M&L for concrete bed to drain pipes in cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified.
M&L for salt-glazed stone ware drain pipes, internal dia of pipe 150mm, grade 'A' laid in trenches and jointed all as specified.
M&L for salt-glazed stoneware gully traps, square mouthed floor trap, size of gully traps in 100mm x 100 mm complete all as specifed.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall including suitable clamps after every one mtr of interval complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius.
S&F for 5mm thick glass mirror of 750mm x 600mm including all edges/ border moulding complete all as specified.
S&F for 5mm thick glass mirror of 1500mm x 750mm including all edges/ border moulding complete all as specified.
S&F for Vitreous China, Half Stall Urinal, White, first quality including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, provision of brass chromium plated spreader suitable for 15mm bore pipe, provision of 40mm bore PVC waste pipe of required length complete all as specified.
S&F for aluminium grill anodized (DG-102, Deco type) 10 mm dia of extruded aluminium section of suitable size and frame including fixing with U clip or F section beading complete with all fitting and fixture and drilling required in RCC section in rectangular or arch type balcony opening of the building complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from frame) area exc 1.5 Sqm but not exc 4 Sqm each complete all as specified.
M&L for Cutting openings, through brick walls built in cement or cement lime mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish from site to outside MoD land.
M&L for preparation of concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge:- (a) Screed bed 10mm thick in cement mortar 1:4 on concrete surfaces using WPC @3% by weight of cement including finished even and smooth surface. (b) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.40 Ltr /Sqm over concrete / plastered roof surface. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame.
M&L for cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate as in surface channel, drain and manholes complete all as specified.
M&L for cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate as in benching, coping etc including necessary form work complete all as specified.
S&F for 8mm thick glass urinal partition including plugs area not exc 1sqm complete all as specified.
M&L for sand cushioning to under ground cable provided with layers of sand ( 8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) complete all as specified.
M&L for brick with burnt clay sub class 'B' laid in trenches for cable protection laid dry flat complete all as specified.
All as per item No 85 above but except bricks (old serviceiable bricks to be reused).
Taking out old unserviceable LT under ground cable any type from trenches,pipes, poles etc complete all as specified.
Relaying of old serviceable LT undergound cable in trenches, pipes and on poles as retrieved from item No. 87 above complete all as specified.
Supply, laying and testing of XLPE LT armoured under ground cable of size 35 Sqmm 3.5 core, 1100 Volt grade with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified.
All as per item No 89 above but of size 95 Sqmm 3.5 core.
Supply & jointing heat shrinkable straight through joint kit suitable for LT 1100 Volt grade XLPE cable of size 70 to 120 Sqmm 3.5 core complete with treating of cable to make ready for jointing etc all as specified.
All as per item No.91 above but suitable for cable size 25 to 50 Sqmm.
S&F for 100mm bore galvanised iron pipe, light grade, laid below road / fixed along the poles / walls with necessary clamps etc complete all as per specified.
S&F for 80mm bore galvanised iron pipe, light grade, laid below road / fixed along the poles / walls with necessary clamps etc complete all as per specified.
S&F for 50mm bore galvanised iron pipe, light grade, laid below road / fixed along the poles / walls with necessary clamps etc complete all as per specified.
Supply, installation, testing and commissioning of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete including taking down old unserviceable LT panel complete all as specified. (Note : Cost of PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate). INCOMING (i) MCCB 250A 4 pole ,35KA with adjustable thermal & adjustable magnetic setting - 1 No (ii) Digital Multi functional meter VAFPP (voltage , current , frequency,power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set.(set of three) OUT GOING:- (i) MCCB 125A 4 pole ,25 KA with adjustable thermal & fixed magnetic setting – 02 Nos (ii) MCCB 100A ,4 pole ,25 KA with adjustable thermal & fixed magnetic setting -01 Nos (iii) MCCB 63 A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -01 Nos (iv) Digital type time switch 16 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory -01 No. (v) MCB TPN 32A 10 KA - 01
M&L for earthing with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32mm x 6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC concrete chamber in 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish internal surface of concrete chamber with 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm in 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM JALLI and charcoal dust and common salt all as shown in Electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe 20mm bore medium grade and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified.
M&L for cutting to existing road / foot path bituminous macadam and PCC on foot path for laying protection pipe for cable and making good the disturbed surfaces of road/ foot path to match with the existing surface all as required and specified (Note: PCC shall be measured and paid seperately).
M&L for cement concrete 1:3:6, type C-2 using 40mm graded stone agreegate as in foundation, mass concrete and filling around pipe complete all as specified.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base including use of necessary form work complete all as specified.
M&L for 100 mm thick cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in floor, pavement etc including finishing surface even and smooth without using extra cement including use of necessary form work complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of white wash including necessary scaffolding complete all as specified.
M&L for rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and confirming to Fe-410 Gde-E250 Quality -A all as specified.
M&L for rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 all as specified.
S&F for pre-painted galvalume aluminum zink coating GI based corrugated steel seet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering ,cladding to wall etc fixed with self taping screws all as specified.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in coping, kerbs in roof or mud stops,rounded or chamfered on edges including necessary form work complete all as specified.
S&F for TMT bars 8 mm dia cut to length, bent to shape, required, including cranking, bending, welding, spirally for hooping for columns,hooking end and bending including mild steel wire (anneealed) not less than 0.9 mm dia or securing with clips complete all as specified.
S&F for 1mm thick (lath thickness) steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple, erected in position as indicated gear operated type with bevel gear box and crank handle complete all as specified.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surfaces of any description over 10 cm in witdth or girth complete all as specified .
S& F for 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified.
S&F for 20mm dia bib tap, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe complete all as specified.
S&F for steel fire point with requisite fire exitinguishing appliances like fire beater (2 Nos), buckets (3 Nos) and ABC fire extinguisher 9 kg (3 Nos), including paintig and writing, erected in position as indicated complete all as specified.
M & L for Point wiring with single core PVC insulated but unsheathed 1.5 Sqmm FRLSH multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories including modular metal flush box with modullar plate for mounting switches, sockets, fan regulators etc and earth wire singlle core PVC insulated but unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLSH cable as continuous earth wire connecting to common earth dolly in concealed wiring system including making good the disturbed surface of wall for one light point controlled by one switch one way complete all as specified.
All as per item No 114 above but for one fan point controlled by one way switch complete all as specified.
All as per item No 114 above but for one socket outlet 5 Pin, 5 Amp on the same board complete all as specified.
All as per item No 114 above but for one socket outlet 5 Pin, 5 Amp on the independent board complete all as specified.
All as per item No 114 above but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete all as specified.
All as per item No 114 above but for one power point 5 pin 15 Amps socket out let with 4 Sqmm stranded copper conductor cable PVC insulated including earth wire 4 Sqmm copper conductor cable connected to earth dolly complete all as specified.
S&F for modular switch 1 way 6/10 Amp, one module complete all as specified.
S&F for modular switch one way 16 Amp, one module complete all as specified.
S & F for socket modular type 6 Amp, 2/3 pin combined 02 Module complete all as specified.
S & F for socket modular type 16 Amp, 2/3 pin combined 02 Module complete all as specified.
S&F for sheet metal enclosure for distribution board SPN (when MCBs to be used ) 4 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified.
S&F for MCB, SPN, 63A ,10KA all as specified.
S&F for MCB, SP 40 Amp ,10KA all as specified.
M&L for sub main wiring with 2 runs of 4 Sqmm of single core PVC insulated but unsheathed FRLSH cable of specified size multistranded copper conductor 1100 Volt grade IS-694 drawing into and including rigid non metallic PVC conduit, medium grade ISI marked ( not less than 25 mm) with all conduit fittings & fixing accessories for concealed in wall/ ceiling or surface including 1 run of 4 Sqmm earth continuity conductor of similar type of cable complete all as specified. (Note : Two runs of single core cable, one run of earth continuity conductor and one metre of conduit shall be measured as one unit.)
S&F for LED luminaire 600 mm x 600 mm, 35/36 watt, 220 Volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified.
S&F for Indoor decorative LED battens- integrated type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete all as specified.
S&F for XLPE LT 1100 Volt Grade, armoured under ground cable of 25 Sqmm 4 core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified.
S&F for energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP -65, 200 watt flood light with high power LEDs as light source, suitable for high lighting architectural facade highmast and general purpose lighting and connection with suitable size copper conductor wire complete all as specified.
S&F for sheet steel enclosures for MCB distribution board SPN 8 way 240Volt with bus bar, neutral link, earth bar din rail conforms IS-8822:96 and EIC 898-96, double door complete all as specified.
S&F for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 25 Amp MCB SP `C' series, complete all as specified.
S&F for ceiling rose, surface bakelite 65mm x 17.5mm, three terminal complete all as specified.
S&F for MCB SPN 32 Amp, curve 'C' breaking capacity10 kA complete all as specified.
S&F for MCB SP 6-32 Amp, curve 'C' breaking capacity10 kA complete all as specified.
S&F for trim clipon LED panel round 24W 6500K unique slimmest recess cum surface panel and including providing and connecting with twin core copper conductor twisted cable and testing on completion all as specified.
S&F for Indoor decorative LED Battens - integrated type 10 watt 2 feet white fixture complete with driver and all accessories internally pre wired and including connecting up with twin core copper conductor cable complete all as specified.
S&F for exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified.
Supply, laying and testing for LT cable XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified.
M & L for earthling complete with GI earth plate electrode 60 cm x 60 cm x 6.30 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 5 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe of 20 mm bore medium grade including excavation & earth work, PCC pit with RCC cover of required size, charcoal salt funnel, GI wire up to 7.5 mtrs length complete all as specified and directed.
RK TRADERS
HANUMAN BUILDERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .