Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.3 LAccepted-AOC 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | L1 | Accepted-AOC L1 | |
| 2 | L2₹98.3 L+₹5.1 L (5.42%)Rejected-AOC 107 2 AMPA MANOR IST FLOOR NELSON MANICKAM ROAD AMINJIKARAI CHENNAI 0 600 029 NO 107 2 AMPA MANOR 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI | L2 | Rejected-AOC L2 |
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
19 Aug 2024, 11:00 amClosed
AGM(E-E)
AAI, Operational Office, AMED-IX, Chennai Airport
FMC of 4 X 100 TR AC Plant and ACMC for Window, Split, Cassette, Ductable Split Air Conditioner and Water Coolers at Chennai International Airport (2024-2026)
2024_AAI_202545_1
AAM/ENGG(E)/AMED-IX/FMCAC/2024
Open Tender
Electrical Works
Works
730 days
Chennai Airport
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,180
Yes
₹2.3 L
20 Nov 2024
25 Jul 2024
20 Aug 2024
25 Jul 2024
19 Aug 2024
25 Jul 2024
25 Jul 2024 - 2 Aug 2024
Amount
SH-I FMC for 4X100 TR HVAC System in Admin Block
Monitoring and Maintenance of Utility Services of HVAC System in AAI Admin Block (As per - List of Inventories) on 2 Shift Basis (Timing as decided by Engineer In Charge - Duty Timing for One Shift: 8 Hours in a Day) for 100% Serviceability i/c providing consumable material like cotton waste, oil, grease, Insulation Tapes and other Sundry Material required for cleaning etc., attending Minor Faults / Assisting OEM during Servicing and Breakdown of Equipments, ensuring satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis as per Standard Manufacturers' Practices (Other than OEM CAMC Works) and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and Reporting as and when required, complete Upkeeping of the Installations etc., on all days except Sundays as specified and as directed by Engineer-In-Charge as required.
SH-II FMC & CMC for Air conditioners and Water coolers
Monitoring and Maintenance of AC Installations (Various Capacity of Window ACs/Split ACs/Cassette ACs/Water Coolers etc.,) at Various Locations at Chennai Airport (As per - List of Inventories) on 8 Hours Day Shift Basis (Timing as decided by Engineer In Charge) for 100% Serviceability i/c providing Consumable and other Sundry Material required for Cleaning, attending Faults / Breakdown of Equipments, ensuring satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and Reporting as and when required, complete Upkeeping of the Installations etc., on all days except Sundays as specified and as directed by Engineer-In-Charge as required. (Supply of Materials other than Cleaning Materials is NOT in the Scope of Item)
All Inclusive (Except Site Labour) Annual Comprehensive Maintenance of following Type Air- Conditioners including Supply of all necessary Spares (Both Electrical and Mechanical), Consumables (Gas/Oil-Other than Cleaning Materials), Major Electrical and Mechanical Components and Equipments (Compressors/Fan/Motors/Cooling Coils, Controls Systems etc.), To Carry Out Routine and General Preventive Maintenance on Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis as per Standard Manu\facturers' Practices and as per Techno Commercial Specifications (TCS) as required. (Man Power Required at SITE is NOT in the Scope of Item-Excluding Airport Site Labour Cost) [Rate is required to be quoted for Yearly Basis]
Split Air-conditioners of 1.0 TR to 2.0 TR Capacity of different make
First Year
Second Year
Split Air-conditioners of 1.5TR to 2.0 TR Capacity Inverter Type of different make
First Year
Second Year
High wall Split Air-conditioners of 3.0 TR Capacity of different make
First Year
Second Year
Split type Vertical Air-conditioners of 3/4.0 TR Capacity of different make
First Year
Second Year
3 Phase, 3.0/ 4.0 Ton Cassette Type Air-Conditioners of different make
First Year
Second Year
Ductable Type Air-Conditioners of 6.0 TR Capacity
First Year
Second Year
Ductable type Air-Conditioners of 9.0 TR Capacity
First Year
Second Year
Ductable type Air- Conditioners of 16.5 TR Capacity
First Year
Second Year
All Inclusive (Except Site Labour) Annual Comprehensive Maintenance of Voltage Stabilizer upto 5KVA Capacity suitable for Window/Split ACs including Repair/Replacement of Components etc., as required at site.
First Year
Second Year
All Inclusive (Except Site Labour) Annual Comprehensive Maintenance of Kelby/Conway Make Water Cooler of Storage Tank Capacity of 80 Liters and RO Purification at 50 LPH Capacity including Supply of all necessary Spares (Both Electrical (including PCB of same Make) and Mechanical ( Including SS Taps)), Consumables (Gas/Oil/Filters (Carbon & Spun)-Other than Cleaning Materials), Major Electrical and Mechanical Components and Equipments (Compressors/Fan/Motors/Cooling Coils/Booster Pumps/Controls Systems (Including All Type of Sensors) etc.), To Carry Out Routine and General Preventive Maintenance on Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS) as required. (Man Power Required at SITE is NOT in the Scope of Item-Excluding Airport Site Labour Cost and Membrane) [Rate is required to be quoted for Yearly Basis]
First Year
Second Year
All Inclusive (Except Site Labour) Annual Comprehensive Maintenance of Zero B Make Eco Chill 40-80-40 / Eco Chill 150-150-150 Cold / Eco Chill 40-120-150 WCN Models Water Coolers with Storage Tank Capacity 80/120/150 Liters and RO Purification with HRR & ESS Technology at 150 LPH Capacity including Supply of all necessary Spares (Both Electrical (including PCB of same Make) and Mechanical ( Including SS Taps)), Consumables (Gas/Oil/Filters (Carbon/Spun/NOVA Cartridge)-Other than Cleaning Materials), Major Electrical and Mechanical Components and Equipments (Compressors/Fan/Motors/Cooling Coils/Booster Pumps/Controls Systems (Including All Type of Sensors) etc.), To Carry Out Routine and General Preventive Maintenance on Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS) as required. (Man Power Required at SITE is NOT in the Scope of Item-Excluding Airport Site Labour Cost and Membrane) [Rate is required to be quoted for Yearly Basis]
First Year
Second Year
All Inclusive (Except Site Labour) Annual Comprehensive Maintenance of Kelby/Conway Make Normal Hot/Cold Water Cooler of Storage Tank Capacity upto 80 Liters including Supply of all necessary Spares (Both Electrical (including PCB of same Make) and Mechanical ( Including SS Taps)), Consumables (Gas/Oil/Filters (Carbon & Spun)-Other than Cleaning Materials), Major Electrical and Mechanical Components and Equipments (Compressors/Fan/Motors/Cooling Coils/Booster Pumps/Controls Systems (Including All Type of Sensors) etc.), To Carry Out Routine and General Preventive Maintenance on Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS) as required. (Man Power Required at SITE is NOT in the Scope of Item-Excluding Airport Site Labour Cost and Membrane) [Rate is required to be quoted for Yearly Basis}
First Year
Second Year
All Inclusive Annual Comprehensive Maintenance of Various Make 7-10 LPH Capacity RO+UV Water Purifier including Supply of all necessary Spares (Both Electrical and Mechanical), Consumables (Other than Cleaning Materials), Major Components Including Membrane, To Carry Out Routine and General Preventive Maintenance on Daily / Weekly / Monthly / Quarterly / Half Yearly / Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS) as required. [Rate is required to be quoted for Yearly Basis]
First Year
Second Year
SH-III SUPPLY OF MATERIALS
Supply of 80/100 GPD Membrane suitable for Kelby / Conway Make RO Type Water Coolers as required.
Supply of 300 GPD Membrane suitable for Conway/kelby Make RO Type Water Coolers as required.
Supply of 100 GPD RO Membrane of make Ion Exchange as and when required for ZERO B make ECO Chill 40-120-150 WCN RO water cooler.
Supply of 300 GPD RO Membrane of make Ion Exchange as and when required for ZERO B make ECO Chill 40-120-150 WCN RO water cooler.
Supply of Pressure pump of model NSF-400L/H-ECO SM 100/150 LTR as and when required for ZERO B make ECO Chill 40-120-150 WCN RO water cooler.
Supply of cordless remote suitable for different make 1.5/2.0 TR/3.0TR split type/window type/tower type/cassette A/C units as required as per Site Requirement.
Supply of Refrigerant copper piping of suitable size and thickness as per OEM Recommendation to connect indoor and outdoor units, including Insulation of 9mm thick nitrile rubber and protective external covering with Cotton tape all necessary supports/fittings etc., as required. (Material Cost of Brazing to be included in the Quote)
Suction Tube & Liquid Tube for 1.5 TR AC
Suction Tube & Liquid Tube for 2 TR AC
Suction Tube & Liquid Tube for 3 TR & 4 TR AC
Supply of Insulation of 9mm thick nitrile rubber and Cotton tape protective external covering with all necessary supports/fittings etc. as required.
Suction Tube & Liquid Tube for 1.5 TR AC
Suction Tube & Liquid Tube for 2 TR AC
Suction Tube & Liquid Tube for 3 TR & 4 TR AC
Supply of standard outdoor wall bracket with vibration pad of suitable size for Split AC Unit up-to 2 TR Capacity of ACs complete as required.
Supply of following Refrigerant Gases for Installation of AC Units at New Location as required.
Supply of 25 mm dia UPVC drain pipe with Insulation and fixing saddles complete as required.
TOOT MNE TECH PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .