Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹11.4 L+₹16,412.84 (1.46%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹11.5 L+₹22,914.84 (2.03%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹12.5 L+₹1.3 L (11.3%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹29.9 L+₹18.6 L (165.2%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
28 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT TO E/M NATURE OF WORKS AT VARIOUS OTM ACCN OF IHQ MOD (ARMY) CAMP AND 10 JAK LI UNDER AGE E/M (S) OF GE (SOUTH) DELHI CANTT-10
2021_MES_439813_1
GE/DS-01/2021-22
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹34,000
Yes
18 Jun 2021
1 May 2021
31 May 2021
1 May 2021
28 May 2021
13 May 2021
2 May 2021 - 11 May 2021
60 days
Amount
Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site Complete all as specified and directed by Engineer-in-Charge. Note:- This item is applicable only where no store is required. 1. One electrician and One helper shall be provided by the contractor for attending daily complaints on working days including holidays/sunday and shall report to MES complaint cell at 08:00 hrs in morning. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The MES department is not responsible for the payment of electrician as all the items of CA are to be supplied and fixed by the Contractor. 4. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 5. A recovery of Rs. 500/- per person shall be recovered from the contractor for non deploying of electrician and 300/- per person for helper on any day. 6. All the complaint slip, register & other connected documents will be provided and maintained by the contractor without any extra cost. 7. Proper record (date wise) of complaints received & rectified by the contractor and attendance register of tradesman shall be maintained and shall be produced for the verification at the time of payment of each RAR/Bill. 8. Fixing of BOQ item No. 2 to 27, 30 to 35 are inclusive with quoted rate of this items.
Supply only in replacement of switch piano flush type 6 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of switch piano flush type 6 Amps SP 2-way complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement bell push, flush type 6 Amps complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of switch piano type 16 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of bell Ding dong type 230 volts single phase complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement for fixing Universal starter for 230/240V, 36/40 FTL & 18/36W FP-L (CFL) complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of 4 pin holder suitable for 36/18 Watts 4pin type CFL fitting as per site requirement complete all as specified and directed by Engineer-in-Charge
Supply only in replacement of CFL 36 watts 4 pin type 6500 K, complete all as specified and directed by Engineer-in-Charge.
Supply only LED Batten T-5 Fitting 20 Watt LED white, indoor decorative aluminium extruded T-5 LED batten integrated type complete in replacement of old existing unserviceable FTL 36 Watt tubelight fitting complete all as specified and directed by Engineer-in-Charge. Make : Cat Part No LTTB4F20WLED/W of C&S or its equivalent in Havell's/Halonix/CG.
Supply only LED Integrated with Aluminium Batten T5 10 watt - 2 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type complete with including fliexble wire in replacement of old unserviceable existing 20 Watt tube light fitting complete all as specified and directed by Engineer-in-Charge. Make : Benlo/Syska/Bajaj/CG
Supply only Surface mounting round/square shaped LED downlighter with durable housing with Al heat shrink with diffuser to give glare free light with removable driver 6 Watt LED 6000K lamp type in replacement of old unsv existing CFL fitting any type from ceiling of stairs/common areas, complete all as specified and directed by Engineer-in-Charge. Make : Benlo/Syska/Bajaj/CG
Supply only LED Building security light fitting 45W on existing bracket in replacement of old unsv existing security light fitting any type complete all as specified and directed by Engineer-in-Charge. Make : Benlo/Syska/Bajaj/CG
Supply only Surface/Recessed mounting 34 Watt (VENUS NEO-857) 2'x2' LED panel fitting, Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling in replacement of old unsv existing 2'x2' CFL fitting any type from ceiling of stairs/common areas and making good a disturbed surface/armstrong ceiling to match with armstrong ceiling and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engineer-in-Charge. Make : Benlo/Syska/Bajaj/CG
Supply only Surface/Recessed mounting 18 Watt (VENUS NEO-857) 1'x1' LED panel fitting, Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling in replacement of old unsv existing CFL fitting any type from ceiling of stairs/common areas and making good a disturbed surface/armstrong ceiling to match with armstrong ceiling and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engineer-in-Charge. Make : Benlo/Syska/Bajaj/CG
Supply only LED Glass Bulb 12 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/SK light fittings in replacement old unsv CFL any watt of complete all as specified and directed by Engineer-in-Charge. Make:- Bajaj/Halonix/C&S/Syska
Supply only in replacement of PVC casing caping of size 25mm with all accesories, in repairs of batten/surface wiring complete, all as specified and directed by Engineer-in-Charge.
Supply only in replacement of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm in Red/Blue/Yellow&Black&green colour wiring as per site requirement complete all as specified and directed by Engineer-in-charge.
Supply only in replacement of PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core in green Red/ Blue Yellow & Black & Green Colour wiring as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core single core in green Red/ Blue Yellow & Black & Green Colour wiring as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm single core single core in green Red/ Blue Yellow & Black & Green Colour wiring as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement PVC insulated FRLS single core with stranded copper cable of size 10 Sqmm single core single core in green Red/ Blue Yellow & Black & Green Colour wiring as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 20 Amps as per site requirement of existing type complete all as specified and directed by Engineer-in-Charge. (Make of MCB : Legrand/Havells/Indoasian/Benlo/HPL/Standard)
S&F in replacement MCB DB SPN 4 Way double door type, (IP 43 Protection) flush mounting with necessary electric connection as per load wise and existing circuit wise including making good the disturb surface of wall complete all as specified & directed by Engr-in-Charge.
S&F in replacement MCB DB SPN 8 Way double door type, (IP 43 Protection) flush mounting with necessary electric connection as per load wise and existing circuit wise including making good the disturb surface of wall complete all as specified & directed by Engr-in-Charge.
Supply only in replacement of MCCB 3 Pole 415V, Adjustable type, with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement of MCCB 3 pole, 415V, Adjustable type,160 Amps with breaking capacity 35 KA complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement MCCB 3 pole 250 Amps 35 KA 415 Volts with breaking capacity 36 KA, complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement for MCB SP 10 to 40 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement for MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement MCB TPN 100 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F 'in replacement' of submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC conduit 25 mm dia conduit complete all as specified and directed by Engineer-in-Charge. Note:- (i) Two runs of main cable and one run of earth cable all-together shall be considered as one length) (ii) In existing conduit wiring new conduit will be added where there is a burnt/ blokage/ damage to the existing conduit including bends/ elbow/ tee junction box etc.
M&L 'in replacement' submain wiring PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing concealed PVC conduit 20 mm dia conduit complete all as specified and directed by Engineer-in-Charge. Note:- (i) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length) (ii) In existing conduit wiring new conduit will be added where there is a burnt/ blokage/ damage to the existing conduit including bends/ elbow/ tee junction box etc.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces of walls, floors including necessary touch up with the adjoining surface of distrubed area i.e with OBD/ Colour wash/ white wash as the existing finish complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including existing concealed PVC conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly Complete all as specified and directed by Engineer-in-charge. for following : Note:-(I) the rate is inclusive cutting /chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash (ii) In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbow/tee junctoin box etc .
One light / fan/bell point controlled by one switch SP, one way, 230 volts.
One light point controlled by two 2-way switch 230 volts.
One 3 pin socket outlet 5/6 Amps on same board.
One 3 pin socket outlet 5/6 Amps on independent board.
One power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
S&F in replacement of distribution board V-triple pole and neutral 4 way for fixing MCCB up to 125 to 160 Amps as incomer and MCBs as out goings with metal door and IP 43 Protections and connecting including necessary touch up with the adoining surface of distrubed area i.e with OBD/ Colour Wash/ White wash as the existing finish complete all as specified and directed by Engineer-in-charge. ( Make : Legrand/ABB/Crabtree)
M&L for MS iron bracket suitable for fixing of bldg security LED light fitting of 30/45 Watts including grouting and fixing the same on wall/pole for instalation of light fitting with necessary clamps, nut, bolts & washer with painting of synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and directed by Engineer-in-charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Microsys Controls India
ramveer Singh
Chaudhary Constructions
M/s NEERAJ KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .