Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹9.7 Cr A 122 DEFENCE COLONY MAWANA ROAD MEERUT U P PH 9720166161 | ₹9.7 Cr |
Tender Value
₹9.7 Cr
EMD Value
₹9.7 L
Closing Date
19 Jul 2023, 11:00 amClosed
Civil and Interior, Modular Kitchen, Electrical, Painting, plumbing work, DG set, Solar panel system, Rain Water Harvesting, Lifts, Horticulture, Water Softener etc.
NSL/CEO/SIDBI-BLR/NIT/2023/586
NSL/CEO/SIDBI-BLR/NIT/2023/586
Open Tender-Domestic
Civil Works General
Bengaluru Urban, Karnataka
₹11,800
₹9.7 L
28 Nov 2023
4 Jul 2023
19 Jul 2023
19 Jul 2023
28 Jul 2023
ABSTRACT OF COST
S.N. DESCRIPTION OF ITEM MR AMOUNT (IN LACS)
2 FIRE FIGHTING WORK 57,80,762.04 1,05,379.22
4 ELECTRICAL & LV WORKS 82,76,894.30 37,03,337.94
6 MULTIPLYING FACTOR FOR 18 % GST 1.06
7 Total Rs including 18 % GST 5,73,06,895.49 3,59,48,837.18
9 GRAND TOTAL Rs with GST 9,72,67,215.34
9 GRAND TOTAL Rs with GST 9,72,67,215.34
Digitally signed by SANJAY
Sl No DSR No Description of Item Unit Quantity DSR rate Amount(Rs) Market Rate Amount(Rs)
Sub-Head : Site works
Demolishing brick work manually/ by mechanical means including stacking of
1 15.7 serviceable material and disposal of unserviceable material within 50 metres lead as
per direction of Engineer-in-charge..
15.7.4 In cement mortar (One side Boundary wall) Cum 30.00 1,698.45 50,953.50
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster
including disposal of rubbish to the dumping ground within 50 metres lead.
Demolishing R.C.C. work by mechanical means and stockpiling at designated
locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking
serviceable and unserviceable material separately including cutting reinforcement
Demolishing cement concrete manually/ by mechanical means including disposal
of material within 50 metres lead as per direction of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum 120.00 2,007.10 2,40,852.00
Dismantling tile work in floors and roofs laid in cement mortar including stacking
material within 50 metres lead.
15.23.2 For thickness of tiles above 25 mm and up to 40 mm Sqm 1,201.50 93.40 1,12,220.10
Dismantling stone slab flooring laid in cement mortar including stacking of
serviceable material and disposal of unserviceable material within 50 metres lead
Dismantling asbestos cement pressure pipes including excavation and refilling
7 15.47 trenches after taking out the pipes manually/ by mechanical means and stacking
the pipes within 50 metres lead as per direction of Engineer-in-charge :
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste
materials by mechanical means, including loading, transporting, unloading to
approved municipal dumping ground or as approved by Engineer-in-charge,
beyond 50 m initial lead, for all leads including all lifts involved.
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including
getting out the excavated soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited layer by
ramming, watering, etc. and disposing of surplus excavated soil as directed, within a
2.10.1 All kinds of soil
2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm metre 120.00 651.55 78,186.00
Earth work in excavation by mechanical means (Hydraulic excavator) / manual
means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on
10 2.8 plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including
getting out the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.
2.8.1 All kinds of soil cum 110.00 286.85 31,553.50
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
11 2.25 foundations etc. in layers not exceeding 20cm in depth, consolidating each cum 30.00 253.95 7,618.50
deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) Cum 30.00 8,512.10 2,55,363.00
Providing and laying factory made chamfered edge Cement Concrete paver
blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required
strength, thickness & size/ shape, made by table vibratory method using PU mould,
laid in required colour & pattern over 50mm thick compacted bed of sand,
compacting and proper embedding/laying of inter locking paver blocks into the
sand bedding layer through vibratory compaction by using plate vibrator, filling the
joints with sand and cutting of paver blocks as per required size and pattern, finishing
and sweeping extra sand. complete all asper direction of Engineer-in-Charge.
80 mm thick C.C. paver block of M-30 grade with approved colour design and
Providing and laying at or near ground level factory made kerb stone of M-25 grade
cement concrete in position to the required line, level and curvature, jointed with
cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without
grooves (thickness of joints except at sharp curve shall not to more than 5mm),
including making drainage opening wherever required complete etc. as per
direction of Engineer-in-charge (length of finished kerb edging shall be measured for
payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
15 16.3 Supplying and stacking at site.
Supplying and stacking of well decayed cattle manure at site including
16 2.26 royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in CUM 150 247.5 37,125.00
stacks will reduced by 8% for Payment).
Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry
palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in
full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the
officer-in-charge.
Providing and stacking winter seasonal seedlings/cuttings at site of work well
18 10.1 developed and healthy free from disease in per tray and each tray having 100 Nos
plants as per direction of the officer-in-charge.
10.1.22 Nasturtium Each 20 500 10,000.00
SITC for Bollards: LED150, Warm White, PSU 220-240V
SITC for Light poles with fixtures : Light fixture IP65 post top lantern with symmetric
20 MR light distribution and limited upward with suitable mounting pole - 3 m High , rust No 20.00 20,350.12 4,07,002.00
resistant, stainless steel complete
21 MR SITC for Landscape/ tree uplighter: Description: Led,12-Watt COB Garden Spike No 20.00 1,700.00 34,000.00
22 MR Supply and installation of Wall Uplighter for highlighting the External Boundary wall No 15.00 2,200.00 33,000.00
Surface dressing of the ground including removing vegetation and inequalities not
1 2.28 exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
2.28.1 All kinds of soil SQM 9.00 27.85 250.65
Digitally signed by SANJAY
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm
nominal size) CUM 6.00 6,326.05 37,956.30
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting samples from different strata,
preparing and submitting strata chart/ bore log, including hire & running charges of
all equipments, tools, plants & machineries required for the job, all complete as per
direction of Engineer-in-charge, upto 90 metre depth below ground level.
a 23.1.1 All types of soil
b 23.1.2 Rocky strata including Boulders
Supplying, assembling, lowering and fixing in vertical position in bore well
unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,
including hire & labour charges, fittings & accessories etc. all complete, for all
depths, as per direction of Engineer-in-charge.
23.4.3 200 mm nominal size dia meter 80 1099.25 87,940.00
Supplying, filling, spreading & leveling stone boulders of size range
5 23.5 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads
& lifts, all complete as per direction of Engineer-in-charge. cum 20 1302.3 26,046.00
Supplying, filling, spreading & leveling gravels of size range 5 mm to
10 mm, in the recharge pit, over the existing layer of boulders, in
required thickness, for all leads & lifts, all complete as per direction
of Engineer-in-charge. cum 20 1309 26,180.00
Supplying, filling, spreading & leveling coarse sand of size range 1.5
7 23.7 mm to 2 mm in recharge pit, in required thickness over gravel layer,
for all leads & lifts, all complete as per direction of Engineer -incharge. cum 20 1309 26,180.00
Gravel packing in tubewell construction in accordance with IS: 4097, including
providing gravel fine/ medium/ coarse, in required grading & sizes as per actual
requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the
9 23.13 top of bore well housing/ casing pipe, removable as per requirement, all complete
for borewell of:
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of
10 23.14 tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-in-
11 8.31 Charge, in skirting, risers of steps and dados,
over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing
with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed
with pigment of matching shade complete.
Providing and laying integral cement based treatment for water proofing on
horizontal surface at all
depth below ground level for under ground structures as directed by Engineer-in-
consisting of :
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a
25 mm thick base
of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing
compound conforming to
22.1 IS:2645 in the recommended proportion over the leveling course (leveling course to
be paid separately).
Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with
compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @
thoroughly embedded in the 2nd layer.
22.1.1 Using rough kota stone. sqm 80 1362.95 1,09,036.00
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10
metrenheight, backing filled with a grout of average 12 mm thick cement mortar 1:3
(1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white
12 cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To
be secured to the backing and the sides by means of cramps and pins which
shall be paid for separately) :
Red sand stone - exposed face fine dressed with rough backing.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more
(thickness to be specified by the manufacturer), of 1st quality conforming to IS :
15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume
Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand),
jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white
cement and matching pigments etc., complete.
Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels /
subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral
crystalline slurry : 1 part water) for horizontal surfaces and applying the same from
14 22.23 negative (internal) side with the help of synthetic fiber brush. The material shall meet
the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of
concrete by more than 90% compared with control concrete as per DIN 1048 and
resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be
capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried
out all complete as per specification and the direction of the engineer-in-charge.
The product performance shall carry guarantee for 10 years against any leakage.
22.23.1 For vertical surface two coats @ 0.70 kg per sqm sqm 130.00 406.25 52,812.50
22.23.2 For horizontal surface one coat @1.10 kg per sqm. sqm 50.00 311.05 15,552.50
Digitally signed by SANJAY
Providing and laying flamed finish Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick
15 11.55 base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching
shade including rubbing, curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or
16 MR SITC of Advnace light arrestor with foundation and all required items needed Nos. 2.00 53,280.37 1,06,560.75
Cleaning of drinking water Ug Tank along with Fire fighting tank with non harardous
chemicals and biocleners
18 MR One time repair of existing motors, pipes in water, drain, fire system L.S 1.00 2,00,000.00 2,00,000.00
Supply, erection, testing & commissioning complete in all respect following sizes of
19 MR 125KVA DG Sets in acoustic ( sound proof /weather proof) enclosure as per CPCB Nos 1.00 14,50,001.34 14,50,001.34
norms including all low side works - foundation, exhast system, AMP panel, etc.
20 MR Supply,installation, testing and commitioning of Water Softener system LS 1.00 2,00,000.01 2,00,000.01
21 SITC of SS main gates including all hardwares like fold fast, L-drop, etc LS 2.00 1,90,000.00 3,80,000.00
22 MR Boom Barrier
Automatic Parking Hydraulic Boom Barrier
Boom Length in 2.75 mtr. LED Type Boom, LED Connectivity
Options., Automatic Barrier Feature:
Barriers Hydraulic barrier (Right /Left Version)with boom
Opening/ Closing Time – 4-5 Sec. Fully.
Automatic with use cycles 100% with push button, Four J
hooks, Foundation plate. Round Boom. Push Button.
BARRIER MODEL 630 STD
Power supply (Vac / Hz) 230 {+6%/ -10%} / 50
Absorbed power (W) 220
Absorbed current (A) 1
Type of oil FAAC HP OIL
Oil quantity (Lt) ~ 1.8 , Barrier weight – 73 Kg
Winding heat protection (°C) 120
Anti-crushing system standard by-pass valves
Type of slow-down Electronic
Operating ambient temperature (°C) -20 / +55
Hood protective treatment Catachresis AISI 316 L
Protection class IP 44
Body Dimensions 390,290, 200,94
Photocell (Safety Beam Sensor)
SITC of above items nos 2.00 2,29,670.45 4,59,340.89
Supply and instalation of SIDBI Logo of appropriate size as per architect/ engineer in
charge over the top of Fascade visi
Providing and fixing double scaffolding system (cup lock type) on the exterior side of
building/structure, up to 25 metre height, above ground level, including additional
rows of scaffolding in stepped manner as per requirement of site, made with 40mm
dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with
cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase
system in the scaffolding for working platform etc. and maintaining it in a serviceable
condition for execution of work of cleaning and/ or pointing and/ or applying
chemical and removing it thereafter.
The scaffolding system shall be stiffened with bracings, runners, connecting with the
building etc, wherever required, if feasible, for inspection of work at required
locations with essential safety features for the workmen etc., complete as per
directions and approval of Engineer-in-charge.
Note :- (1) The elevational area of the scaffolding shall be measured for payment
(2) The payment will be made once only for execution of all items for such works. Sqm 2,560.00 285.00 7,29,600.00
Chipping of unsound/weak concrete material from slabs, beams,
columns etc. with manual Chisel and/ or by standard power driven percussion type
or of approved make including tapering of all edges, making square shoulders of
cavities including cleaning the exposed concrete surface and reinforcement with
wire brushes etc. and disposal of debris for all lead and lifts all complete as per
direction of Engineer-In-Charge
26.28.2 50mm average thickness Sqm 1,500.00 211.55 3,17,325.00
Providing and injecting approved grout in proportion recommended by the
manufacturer into cracks/honey-comb area of concrete/ masonry by suitable
26 26.35 gun/pump at required pressure including cutting of nipples after curing etc.
complete as per directions of Engineer-in- Charge. (The payment shall be made on
the basis of actual weight of approved grout injected.)
26.35.3 Epoxy injection grout in concrete/RCC work of approved make KG 800.00 793.25 6,34,600.00
Providing, erecting, maintaining and removing temporary protective screens made
27 26.36 out of specified fabric with all necessary fixing arrangement to ensure that it remains
in position for the work duration as required by the Engineer-in-charge.
Cleaning of exposed concrete surface of sticking material including loose and
28 26.37 foreign material by sand blasting with coarse sand followedby and including sqm 900.00 370.15 3,33,135.00
cleaning with oil free air blast as per direction of Engineer in charge.
Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix
concrete having the specified minimum characteristic compressive strength [with
ordinary portland cement, coarse sand and graded stone aggregate of 10 mm
maximum size in proportion as per design criteria] including the cost of centering
and shuttering at edges and corners etc. as directed by Engineerin- Charge Note:
Rates shall include the providing necessary ground wires etc.
The levelling gauges, if used, shall be paid for separately. Payment
under this item shall be made only after proper wet curing has been done and
surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal
26.38.2 50mm thick in Grade M 25 with cement content not less than 330 kg per cum sqm 900.00 1,073.45 9,66,105.00
Digitally signed by SANJAY
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb
area and along crack line including drilling of holes of required diametre (20mm to
30mm) up to depth from 30mm to 80mm at required spacing and making the hole &
crack dust free by blowing compressed air, sealing the distance between injection
nipple with adhesive chemical of approved make and allow it to cure complete as
per direction of Engineer-In-Charge.
Providing and fixing hard drawn steel wire fabric of size 75 x25 mm
mesh or other suitable size wire mesh to be fixed & firmly anchored
31 26.40 to the concrete surface by means of "L" shaped mild steel shear key welded with sqm 950.00 820.80 7,79,760.00
existing reinforcement including the cost of materials, labour, tool & plants as
approved by Engineer-in-charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete :
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and
0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement
plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with
a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm nominal size), and making necessary
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a floating coat of neat cement, all
complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation)
560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame
to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand
: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12mm thick cement plaster at the external
surface shall be paid for separately) :
19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 15.00 11,886.45 1,78,296.75
35 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 30.00 11,666.90 3,50,007.00
Repair and maintenance of mislaneous items on site unearthed during the
restoration and revitalization process.
37 MR SITC of vertical cycle parking Nos 30.00 5,511.36 1,65,340.81
Preparation of complete set of shop drawings including finishing, MEP services,
details, design calcualtions etc. and any other details as and when desired by
Engineer In charge /client. A qualified professsional for the purpose shall be
appointed after due appproval from Engineer In Charge.
Supply & Installation of tensile fabric canopy in set back to cover car parking bays.
Supply & Installation of free standing tensile fabric canopy. The entire structural
frame work should be designed as per the current codes and fixed over granite
platform / in ground including digging concrete base preparation for foundation
block base plate and erection with repair and resurfacing to match existingfinish.
The fabric to be Ferrari/ low & Bonar or equivalent Fabric is resistance to U.V. rays
and color degradation, U.V. resistance: 7 to 8/8 treated with Teflon for anti staining,
oil repellency and rot proof with a Water Repellent- 30 cm water column and will not
support mildew growth The structure should be complete in all respect including
fittings and accessories. Provision of water drainage via. channel and pipe at the
end of the slope required.
foundation preparation for the tubular section , PCC block exceeding 100mm on all
side more than tubular section foot print, structure should withstand wind load or
structurally sound etc. complete subject to detail engineering on site and submit sqm 220.00 12,476.47 27,44,822.77
shop drawings/ stadd calculation before starting the work.
Providing and fixing 6mm thick poly-carbonate sheet with 40% transparency as per
vendor and to be matched with existing on roof of the attrium including cost of
removing of existing roof sheet and dumping/ storing the same as per instruction of
40 MR Project in charge, including cost of all necessary fixing arrangement, framing sqm 30.00 4,082.69 1,22,480.76
wherever required complete with all respect as per manufecturer details and
specification and instruction of Project in charge/ Architect. (the cost to including
SITC of colour coded garbage bins suitable for both for wet and dry waste of upto
700 liter capacity.
Digitally signed by SANJAY
S. No. DSR Code Description Unit Qty DSR Rate Amount Market Rate Amount
Surface dressing of the ground including removing vegetation and
1 2.28 inequalities not exceeding 15 cm deep and disposal of rubbish,
lead up to 50 m and lift up to 1.5 m.
2.28.1 All kinds of soil SQM 90.00 28.15 2,533.50
Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth,
2 2.6.1 1.5 m in width as well as 10 sqm on plan) including getting out and Cum 150.00 205.45 30,817.50
disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.- All kinds of soil
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m.
Disposal of surplus earth by mechanical transport including
loading, unloading for a lead upto 10 Km.
Providing and laying in position cement concrete of specified
4.1 grade excluding the cost of centering and shuttering - All work up
to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone
aggregate 40 mm nominal size)
Providing and laying in position ready mixed or site batched
design mixcement concrete for reinforced cement concrete work;
using coarseaggregate and fine aggregate derived from natural
sources, PortlandPozzolana / Ordinary Portland /Portland Slag
cement, admixtures inrecommended proportions as per IS: 9103
to accelerate / retard settingof concrete, to improve durability
and workability without impairingstrength; including pumping of
concrete to site of laying, curing, carriagefor all leads; but
excluding the cost of centering, shuttering, finishingand
reinforcement as per direction of the engineer-in-charge; for
thefollowing grades of concrete.
Note : Extra cement up to 10% of the minimum specified cement
contentin design mix shall be payable separately. In case the
cement contentin design mix is more than 110% of the specified
minimum cementcontent, the contractor shall have discretion to
either re-design the mixor bear the cost of extra cement
5.33.1 All works upto plinth level
Concrete of M25 grade with minimum cementcontent of 330 kg
Steel reinforcement for R.C.C. work including straightening,
5 5.22 cutting, bending, placing in position and binding all complete
upto plinth level.
5.22.6 Thermo-Mechanically Treated bars KG 16,351.28 89.65 14,65,892.34
Centering and shuttering including strutting, propping etc. and
removal of form for :
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete SQM 107.56 307.95 33,123.10
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
Providing and fixing 1st quality ceramic glazed floor tiles
conforming to IS : 15622 (thickness to be specified by the
manufacturer ) of approved make in all colours, shades except
burgundy, bottle green, black of any size as approved by Engineer-
in-Charge in skirting, risers of steps and dados over 12 mm thick
bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing
with grey cement slurry @ 3.3kg per sqm including pointing in
white cement mixed with pigment of matching shade complete.
Providing and mixing integral crystalline admixture for water
proofing treatment to RCC structures like basement raft, retaining
walls, reservior, sewage & water treatment plant, tunnels / subway
and bridge deck etc. at the time of transporting of concrete into
the drum of the ready-mix truck, using integral crystalline
admixture @ 0.80% (minimum) to the weight of cement content
per cubic meter of concrete) or higher as recommended by the
manufacturer’s specification in reinforced cement concrete at site
8 22.22 of work. The material shall meet the requirements as specified in kg 284.49 332.40 94,564.87
ACI-212-3R- 2010 i.e. by reducing permeability of concrete by
more than 90%, compared with control concrete as per DIN 1048
and resistant to 16 bar hydrostatic pressure. The crystalline
admixture shall be capable of self-healing of cracks up to a width
of 0.50mm. The work shall be carried out all complete as per
specification and the direction of the Engineer-in-charge. The
product performance shall carry guarantee for 10 years against
Supplying, installation, testing and commissioning of Electric driven
1 1 Main Fire Pump suitable for automatic operation and consisting of
following, complete in all respects, as required:
(a) Horizontal type, multistage, centrifugal, split casing pump of
cast iron body & bronze impeller with stainless steel shaft,
mechanical seal conforming to IS 1520.
(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous
speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz,
AC supply with IP 55 protection for enclosure, horizontal foot
mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling
guard, foundation bolts etc. as required.
(d) Suitable cement concrete foundation duly plastered with anti
vibration pads.
Supplying, installation, testing and commissioning of diesel engine
driven main fire pump suitable for automatic operation and
consisting of following, complete in all respects, as required :
(Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body
and bronze impeller with stainless steel shaft, mechanical seal
conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant IS standard complete with auto starting
mechanism, 12 /24 volts electric starting equipment, diesel tank,
exhaust pipe extended upto 10 m outside pump house duly
insulated with 50 mm thick glass wool with 1.0 mm thick aluminium
sheet cladding, residential silencer, instruments and protection as
per standard specification, stop solenoid for auto stop in the event
of fault with audio indications, painted with post office red colour
etc. as required.
M.S fabricated, common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
Supplying, installation, testing and commissioning of electric
driven pressurisation pump suitable for automatic operation and
consisting of following, complete in all respects, as required :
Digitally signed by SANJAY
Horizontal type, multistage, centrifugal pump of cast iron body
and bronze impeller with stainless steel shaft, mechanical seal
conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for
operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of
protection for enclosure, horizontal foot mounted type with Class-
'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti
vibration pads.
Fabrication, supply, Insallation testing & commissioning of
Electrical control panel of cubical construction, floor mounted
type, fabricated out of 2mm thick CRCA sheet,
compartmentalised with hinged lockable doors, dust and vermin
proof, powder coated of approved shade after 7 tank treatment
process, cable alley, interconnection with suitable size copper
4 5 conductor cable/solid copper strip, having switchgears and
accessories, mountings and internal wiring, earth terminals,
numbering etc. complete in all respect, suitable for main fire
pump, pressurisation pump & diesel pump set complete as per
CPWD specification with following in coming and Outgoings,
suitable for operation on 415V, 3 phase, 50Hz Ac Supply with
enclosure protection class IP 42 as required :
4.1 5.1 Incomings
250A, 50kA 4 Pole MCCB, Ics=100% Icu rating
Digital Voltmeter 0-500V with selector switch
Digital Ammeter (0-250 A) with selector swtich & CTs
LED type RYB phase indicating lamps, ON, OFF, trip indicating
Set of Copper Bus Bar 300A
( Note : All outgoing feeders for pumps should have digital
Ammeter with selector switches, and LED type ON, OFF, trip
indicating lamps)
125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic
Star/Delta starter suitable for 60 HP pump with overload
protection, current sensing type single phase preventor complete
with all acceessories and internal wiring required for automatic
operation, selector switch for local/remote, auto/manual/OFF
63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully
automatic Star/Delta starter with overload protection, current
sensing type single phase preventor complete with all
acceessories and internal wiring required for automatic operation,
selector switch for local/remote, auto/manual/OFF operation.
Diesel Engine Control
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempt starting device,
timers and relays as required, push buttons, start/stop in manual
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indication
Battery charger suitbale for 12V/24 V DC with boost and trickle
selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter
All standard relays and accessories for automatic operation of
System Controller
Designing, Supply, Installation, Testing and commissioning of
system controller to control operation of main electric fire pump,
diesel pump, Pressurization pump, Terrace pump in sequence as
per specification consisting of relays, timers. Sensors, annunciation
window for fault indication, complete as per specification
Providing laying, testing & commissioning of 'C' class heavy duty
MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees,
flanges, tapers, nuts bolts, gaskets etc. in ground including
5 6 welding, excavation & providing cement concrete blocks as
supports, anticorrosive treatment with coaltar/asphalt tape as per
IS 10221, refilling the trench etc. of following sizes complete as
Supplying and fixing Single headed external yard hydrant valve
with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel
6 10 coupling and cast iron wheel, ISI marked, conforming to IS 5290
(type A) with blank Gunmetal/Stainless Steel cap and chain as
6.1 10.1 Single headed Gunmetal Set 4.00 7,494.00 29,976.00
Supplying, fixing, testing and commissioning of butterfly valve of
PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete
with nuts, bolts, washers, gaskets conforming to IS 13095 of
following sizes as required :
Supplying, fixing, testing & commissioning of double flanged sluice
valve of rating PN 1.6 with non rising spindle, bronze/gun metal
seat, ISI marked complete with nuts, bolts, washers, gaskets and
conforming to IS 780 of following sizes as required :
Providing, installation, testing and commissioning of non-return
10 14 valve of following sizes confirming to IS: 5312 complete with rubber
gasket, GI bolts, nuts, washers etc.as required :
Providing, installation, testing and commissioning of stainless steel
11 15 Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304,
sheet with 3 mm dia holes with stainless steel flange.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63
12 16 mm dia male and female couplings duly bound with GI wire, rivets
etc. conforming to IS 636 (type-A) as required :
Supplying and fixing first-aid Hose Reel with MS construction spray
13 17 painted in post office red, conforming to IS 884 complete with the
following as required.
20 mm nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall. Connections
from riser with 25 mm dia stop gun metal valve & M.S. Pipe and
Digitally signed by SANJAY
Supplying & fixing 63 mm dia gun metal short branch pipe with 20
mm nominal internal diameter size nozzle conforming to IS 903
suitable for instantaneous connection to interconnect hose pipe
coupling as required :
Supplying and fixing of fire brigade connection of cast iron body
with gun metal male instantaneous inlet couplings complete with
cap and chain as reqd. for suitable dia MS pipe connection
conforming to IS 904 as required :
Providing and fixing ISI Marked of approved make Fire Extinguishers
complete with all accessories as per manufacturer's specifications.
MR CO2 gas nozzle type - 6.5 Litre capacity (IS:15683). Nos 8.00 13,172.40 1,05,379.22
Digitally signed by SANJAY
Sl No DSR No Description of Item Unit Quantity DSR Rate Amount(Rs) Market Rate (Rs) Amount(Rs)
Demolishing brick work manually/ by mechanical means
including stacking of serviceable material and disposal of
unserviceable material within 50 metres lead as per direction
of Engineer-in-charge..
15.7.4 In cement mortar opening kitchen wall Cum 20.00 1,698.45 33,969.00
Dismantling doors, windows and clerestory windows (steel or
2 15.12 wood) shutter including chowkhats, architrave, holdfasts etc.
complete and stacking within 50 metres lead :
15.12.1 Of area 3 sq. metres and below No. 310.00 302.70 93,837.00
Dismantling old plaster or skirting raking out joints and cleaning
3 15.56 the surface for plaster including disposal of rubbish to the
dumping ground within 50 metres lead.
Outer plaster Sqm 1,500.00 45.05 67,575.00
inner plaster Sqm 1,467.00 45.05 66,088.00
Dismantling tile work in floors and roofs laid in cement mortar
including stacking material within 50 metres lead
4 15.23.1 15.23.1 For thickness of tiles 10 mm to 25 mm Sqm 2,520.00 60.50 1,52,460.00
Removing dry or oil bound distemper, water proofing cement
paint and the like by scrapping, sand papering and preparing
the surface smooth including necessary repairs to scratches
for internal walls Sqm 4,995.00 20.85 1,04,146.00
for External ceiling Sqm 2,560.00 20.85 53,376.00
Dismantling C.I. pipes including excavation and refilling
trenches after taking out the pipes, manually/ by mechanical
6 15.45 means breaking lead caulked joints, melting of lead and
making into blocks including stacking of pipes & lead at site
within 50 metre lead as per direction of Engineer-in-charge:
Dismantling asbestos cement pressure pipes including
excavation and refilling trenches after taking out the pipes
manually/ by mechanical means and stacking the pipes within
50 metres lead as per direction of Engineer-in-charge :
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous
8 15.52 China) including stacking of useful materials near the site and No. 75.00 744.60 55,845.00
disposal of unserviceable materials within 50 metres lead.
Dismanteling old Electrictical wiring including stacking of useful
9 MR materials near the site and disposal of unserviceable materials LS 23.00 5,310.00 1,22,130.00
within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable,
dismantled or waste materials by mechanical means,
including loading, transporting, unloading to approved
municipal dumping ground or as approved by Engineer-in-
charge, beyond 50 m initial lead, for all leads including all lifts
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a
floating coat of neat cement.(External)
Extra for plastering exterior walls of height more than 10 m from
ground level for every additional height of 3 m or part thereof.
Repairs to plaster of thickness 12 mm to 20 mm in patches of
area 2.5 sq.meters and under, including cutting the patch in
proper shape, raking out joints and preparing and plastering
the surface of the walls complete, including disposal of rubbish
to the dumping ground, all complete as per direction of
Engineer-in-Charge
With cement mortar 1:4 (1cement: 4 coarse sand) with chiken
mesh/ fiber mesh
Extra for providing and mixing water proofing material in of 50kg
15 13.21 cement plaster work in proportion recommended by the cement 1,680.00 60 1,00,800.00
manufacturers. used in
Providing and laying vitrified floor tiles in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08%and conforming to IS : 15622 , of
16 11.41 approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand) jointing with
grey cement slurry @ 3.3kg/sqm including grouting the joints
with white cement and matching pigments etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size
300x300 mm or more (thickness to be specified by the
manufacturer), of 1st quality conforming to IS : 15622, of
approved make, in all colours, shades, except White, Ivory,
Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4
(1 Cement : 4 Coarse sand), jointing with grey cement slurry @
3.3kg/sqm including pointing the joints with white cement and
matching pigments etc., complete.
18 13.6 20 mm cement plaster of mix : (for external walls)
19 15 mm cement plaster of mix: (for internal walls)
Providing and laying water proofing treatment in sunken
portion of WCs, bathroom etc., by applying cement slurry
mixed with water proofing cement compound consisting of
applying : a) First layer of slurry of cement @ 0.488 kg /sqm
mixed with water proofing cement compound @ 0.253
20 22.5 layer will be allowed to air cure for 4 hours. b) Second layer of SQM 458.00 516.6 2,36,603.00
slurry of cement @ 0.242 kg/ sqm mixed with water proofing
cement compound @ 0.126 kg/ sqm. This layer will be allowed
to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and
sealing of all joints, corners, junctions of pipes and masonry
with polymer mixed slurry.
FOAM CONCRETE FILLING UNDER TOILETS AND PANTRY:- Filling
and compacting Foam Concrete for raising level of toilets and
21 pantry and finishing in a coat of lean concrete screeding with CUM 67.00 5,308.53 355672
waterproofing compound complete in all respects to take Tile
Flooring as per flooring specifications.
Digitally signed by SANJAY
TILE DADO :- Providing and fixing Ist quality ceramic glazed
wall tiles conforming to IS: 15622 (thickness to be specified by
the manufacturer), of approved make, in all colours, shades
except burgundy, bottle green, black of any size as approved
22 8.31 by Engineer-in-Charge, in skirting, risers of steps and dados, sqm 1,290.00 1063.45 13,71,851.00
over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed with pigment of
matching shade complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen
platforms, vanity counters, window sills, facias and similar
locations of required size, approved shade, colour and texture
23 8.2 laid over 20 mm thick base cement mortar 1:4 (1 cement : 4
coarse sand), joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing,
curing, moulding and polishing to edges to give high gloss
finish etc. complete at all levels
8.2.2 Granite stone slab colour black, Cherry/Ruby red Sqm 159.60 4,425.35 7,06,286.00
Providing edge moulding to 18 mm thick marble stone
counters, Vanitiesetc., including machine polishing to edge to
give high gloss finish etc. complete as per design approved by
Engineer-in-Charge.
8.3.2 Granite work metre meter 266.00 418.85 1,11,414.00
Providing and laying Polished Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of
the building all complete as per the architectural drawings
with 18 mm thick stone slab over 20 mm (average) thick base
25 11.56 of cement mortar 1:4 (1 cement : 4 coarse sand) laid and
jointed with cement slurry and pointing with white cement
slurry admixed with pigment of matching shade including
rubbing, curing and polishing etc. all complete as specified
and as directed by the Engineer-in-Charge
Polished Granite stone slab colour of Black, Cherry/Ruby
Red or equivalent
Three track three panels sliding window with fly proof SS wire
mesh (Two nos. glazed & one no. wire mesh panels) made of
26 9.147D.2 (small series) frame 92 x 44 mm & sash 32 x 60 mm both having Sqm 452.00 10,030.30 45,33,696.00
wall thickness of 1.9 ± 0.2 mm and single glazing bead of
appropriate dimension (Area of window upto 1.75 sqm).
Casement window single panel with S.S. friction hinges (300 x
19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash
27 9.147A.1 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and Sqm 118.00 10,443.75 12,32,363.00
single glass pane glazing bead of appropriate dimension.
(Area of window upto 0.75 sqm.)
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over
the plastered wall surface to prepare the surface even and
smooth complete.
Applying priming coats with primer of approved brand and
29 13.85 manufacture, having low VOC (Volatile Organic Compound )
With water thinnable cement primer on wall surface
having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content
31 13.83 less than 50 grams/ litre. of approved brand and manufacture,
including applying additional coats wherever required to
achieve even shade and colour.
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding,
grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel
nuts and bolts complete, i/c fixing the railing with necessary
32 10.28 accessories & stainless steel dash fasteners , stainless steel bolts Kg 2,450.00 612.25 15,00,013.00
etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in
charge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such
as nuts, bolts, fasteners etc.).
Providing and laying in situ seven course water proofing
treatment with APP (Atactic Polypropylene) modified
Polymeric membrane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of
bonding material @ 1.20 kg/sqm, which shall consist of blown
type bitumen of grade 85/25 conforming to IS : 702, 3rd and
5th layers of roofing membrane APP modified Polymeric
membrane 2.0 mm thick of 3.00 Kg/sqm weight consisting of
five layers prefabricated with centre core as 100 micron
HMHDPE film sandwiched on both sides with polymeric mix and
the polymeric mix is protected on both side with 20 micron
7th, the top most layer shall be finished with brick tiles of class
designation 10 grouted with cement mortar 1:3 (1 cement : 3
fine sand) mixed with 2% integral water proofing compound by
weight of cement over a 12 mm layer of cement mortar 1:3 ( 1
cement : 3 fine sand) and finished neat (item of laying brick
tiles shall be paid for separately).
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate) finished with a floating coat of neat
cement, including cement slurry, but excluding the cost of
nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm 200.00 545.00 1,09,000.00
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300
mm x 20 mm) with SRI (solar refractive index) > 78, solar
reflection > 0.70 and initial emittance > 0.75 on waterproof and
sloped surface of terrace, laid on 20 mm thick cement sand
35 12.55 mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and Sqm 750.00 1,444.90 10,83,675.00
grouting the joints with mix of white cement & marble powder
in ratio of 1:1, including rubbing and polishing of the surface
upto 3 cuts complete, including providing skirting upto 150 mm
height along the parapet walls in the same manner.
Digitally signed by SANJAY
Providing and fixing double scaffolding system (cup lock type)
on the exterior side of building/structure, upto 25 metre height,
above ground level, including additional rows of scaffolding in
stepped manner as per requirement of site, made with 40mm
dia M.S. tube, placed 1.5 metre centre to centre, horizontal &
36 24.2 vertical tubes joint with cup & lock system with M.S. Tubes, M.S.
tube challis, M.S. clamps and staircase system in the
scaffolding for working platform etc. and maintaining it in a
serviceable condition for execution of work of cleaning and/
or pointing and/ or applying chemical and removing it
The scaffolding system shall be stiffened with bracings, runners,
connecting with the building etc, wherever required, if
feasible, for inspection of work at required locations with
essential safety features for the workmen etc., complete as per
directions and approval of Engineer-in-charge.
Note :- (1) The elevational area of the scaffolding shall be
measured for payment purpose.
(2) The payment will be made once only for execution of all
items for such works.
Size of Tile 800x800 mm
Providing 10 mm thick plaster of Paris (gypsum anhydrous)
ceiling up to a height of 5 m above floor level, over first class
37 12.31 kail wood strips 25x6 mm with 10 mm gap in between and
reinforced with rabbit wire mesh fixed to wooden frame (frame
work to be paid separately):
Extra for sunk or raised mouldings in the plaster of Paris
(Gypsum anhydrous) ceiling.
Providing wood work in frames of doors, windows, clerestory
windows and other frames, wrought framed and fixed in
43 position with hold fast lugs or with dash fasteners of required cum 6.48 1,31,576.95 8,52,816.00
dia & length (hold fast lugs or dash fastener shall be paid for
separately). Second class teak wood
Providing and fixing ISI marked flush door shutters conforming
to IS : 2202 (Part I) decorative type, core of block board
construction with frame of 1st class hard wood and well
44 9.20.1 matched teak three ply veneering with vertical grains or cross Sqm 321.84 3,086.10 9,93,230.00
bands and face veneers on both faces of shutters. 35 mm thick
Fixing with hinges of required size and necessary screws (Note:
Hinges and necessary screws hall be paid separately
SITC Stainless steel SS-304 kitchen sink - with drain board 510 x
1040 mm bowl depth 270 mm (min)
MORTICE LOCK AND LEVER HANDLES- Providing and installing
Tubular Handle TH 123 with Roses & Escutcheon in SS
packaged with Mortice lockset 55mm backset, 20 SS forend, SS
strike plate and EP Cylinder for all flush doors.
Providing and fixing bright finished brass 100 mm mortice latch
with one dead bolt and a pair of lever handles of approved
quality with necessary screws etc. complete.
Providing and fixing modular kitchen units for the kitchen
platform and top wall units to be fabricated by using HDHMR
48 MR board of thickness 18 mm for making cabinets of required sizes
to match with the sizes SS kitchen jali units and size of the SS sink
as per following details:-
Front , bottom , top , sides and shelf partitions of the modular
cabinets shall be of 18 mm thick HDHMR boards of M/s Green
panel Industries or approved equivalent and back portion shall
be of 8 mm thick HDHMR board or approved equivalent with
necessary fittings , screws , pasting materials, finishing all
exposed cut surfaces with self adhesive PVC tape in matching
shade as that of laminate . The shutters and the pull out units
shall be fixed 50 mm above the kitchen floor level . All the inner
portions of the cabinets shall be finished with 0.8 mm thick
laminate of white colour and approve make .. The front face
of the cabinet shall be finished with1 .0 mm ultra gloss laminate
shade 21162 MR+ & 21069 MR+ Merino make The fittings like
handles , telescopic channels , SS baskets , auto closing hinges
shall be paid separately under respective items below. Quoted
rates shall be inclusive of labour , materials , wastage ,
scaffolding , fixing arrangements of top and bottom units with
necessary dash fasteners , repairing the damages, shifting the
debris out of colony , CP , taxes etc all as required for the
execution of the work . Note :-Only front elevation area shall
be measured for payment purpose,
Top wall units of depth 300 mm approx. with shelves Sqm 115.00 18,000.00 20,70,000.00
Providing and fixing stainless steel baskets and other fittings,
50 MR accessories of modular kitchen of M/s Hettich or approved each 276.00 3,000.00 8,28,000.00
equivalent make as per below mentioned details :-
Supply and instalation of heavy duty SS 304 external grade
Cloth Hanger/Dryer for Balony, celing mounted with with UV
Protected Nylon Rope and Individual Drop Down Railer syetem
upto 12ft length
Providing and placing on terrace (at all floor levels)
polyethylene water storage tank, IS : 12701 marked, with cover
52 18.48 and suitable locking arrangement and making necessary holes per litre 50,000.00 9.70 4,85,000.00
for inlet, outlet and overflow pipes but without fittings and the
base support for tank.
Complete dismantling of lifts along with disposal of old
machine parts as per Engineer incharge
Supply and Installation of lift for 8 person passenger lift along
with all necessary parts
TV Cabinet Unit- in 18 mm HDHMR ply of size 1500mm x 1200
mm having setup box holder, size 1200 mm x 200 mm placed
100 mm from bottom of TV unit. All side with 2mm laminate of
approved colour and provision of 6/16 Amp socket at top, TV
cable with switch plate. Two numbers of n6/16 Amp socket
with control switch above set up box
Digitally signed by SANJAY
Low side Airconditioning works including chasing, Copper
piping, insulation of copper pipe, and repairing of chased
area with cement and mortar wherever required to match
56 MR existing plastered surface. Specified brand for insulation rmt 1,100.00 1,054.37 11,59,804.35
Superlon with wall thickness of minimum 13mm. SPecified
brand for copper piping. Only One (1) length between indoor
and outdoor unit shall be measured for payment.
Low side Airconditioning works including chasing, laying of
drain pipe, sealing of all joints, and repairing of chased area
57 MR with cement and mortar wherever required. For drain piping rmt 705.00 395.00 2,78,471.50
UPVC pipes of 10KGF to be used. Of 25mm Diameter.
Interconnecting cable for AC units between indoor & Outdoor
59 MR SITC Of chimney for kitchen. nos. 23.00 12,000.00 2,75,999.91
60 MR SITC of wardrobe as per design and detail. nos. 63.00 75,000.00 47,25,000.00
CEILING PELMETS :- Providing and fixed pelmet of overall size
150mmx150mm and made hardwood framings hung from
ceiling @1000mm centre to centre with 2 nos of 6mm thk.
Commercial ply on vertical & 12mm thk. Commercial ply on
horizontal surface (straight & curved). Inclusive of finishing in
64 MR SITC of concealed door closer Nos. 23.00 6,444.42 1,48,221.56
65 MR SITC of Curtain Rod m 23.00 644.93 14,833.32
SITC of SS-304 Steel Safety Main door, with inetrnal SS-304
Mosquito Mesh, with heavy duty interlock
1 SOLAR PANELS
Schedule of Supply, Installation, Testing and Commissioning of on grid Solar
Rates & Delhi Photovoltaic Power Plant conforming to MNRE specifications
Analysis of as amended, consisting of Mono/ Poly Crystalline silicon solar
Rates (E&M) cells, net metering facility, necessary protections, earthing,
(Item for Solar mounted on Aluminium/ GI structure of suitable strength with
Photovoltaic following components complete as required:-
a)Solar Photo voltaic Module of capacity 330W por above,
manufactured in India, conforming to IS 14286/ IEC61215, IS/
IEC61730 - Part - 1, IS/IEC61730 - Part - 2. Solar Photo voltaic
Module conversion efficiency shall not be less than 16.5%. PV
modules used in solar power plants / systems must be
warranted for their output peak watt capacity ,which should
not be less than 90% at the end of 10 years and 80% at the end
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage
range and 400 V AC, three phase, 4 wire, 50 Hz+/- 2.5Hz, output
voltage suitable to generate AC Power with efficiency not less
than 97%, total harmonic distortion less than 3% and suitable for
ambient temperature from 0 to 50 degree C. The PCU shall
adjust the voltage and frequency level to suit the Grid Voltage
c) Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP65
protection and termination arrangement for incoming and out
going cable along with glands, lugs and other accessories etc.
e) Lightning and surge voltage protection.
f) Connections & Interconnections by supplying & fixing
required size XLPE insulated copper conductor 1.1kV grade
armoured power and control cables between solar modules,
main power cable to grid supply PCU unit along with supplying
& fixing of necessary channel/ conduit lugs and other
accessories etc. as required.
Digitally signed by SANJAY
Detail Estimate Based On DSR 2022 & Market Based Item
Project: RESTORATION OF SIDBI APARTMENTS, BANGALORE
Name of Work: Internal Electrification Work
Rate Rs. Amount Rs.
S.No. Description Qty. Unit DSR Item Non-DSR Item DSR Item Non-DSR Item Sch. No.
Sub Head 1 : WIRING IN STEEL AND PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core cable in surface / recessed
1 steel conduit, with modular switch, modular plate, suitable GI box and earthing
the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core
cable etc. as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call
bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated
2 copper conductor single core cable in surface/ recessed steel conduit, and 1.54
earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single
core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface /
recessed steel conduit, 2 way modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable etc. as
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
4 FRLS PVC insulated copper conductor, single core cable in surface/ recessed 1.7
steel conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone
cable in the existing surface/ recessed steel/ PVC conduit as
Supplying and drawing co-axial TV cable, 0.7 mm
solid copper conductor PE insulated, shielded with fine tinned copper braid
and protected with PVC sheath in the existing surface/ recessed steel/ PVC
conduit as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed
9 copper conductor, armored telephone cable as required similar to Skytone or
Supplying and fixing two module stepped type electronic fan
10 regulator on the existing modular plate switch box including 168.0 Each 369.00 61,992.00 0.00 1.25
connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular
11 plate & switch box including connections but excluding modular plate etc. as 1.24
c Telephone socket outlet 84.0 Each 148.00 12,432.00 0.00 1.24.6
d TV antenna socket outlet 84.0 Each 148.00 12,432.00 0.00 1.24.7
e RJ 45 Socket For Internet Similar to Legrand Cat Ref. 673155 or equivalent. 84.0 Each 470.07 0.00 39,485.79 MR (RA-3)
Digitally signed by SANJAY
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc. as required.
Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess, including providing and fixing 3 pin
5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as
Supplying and fixing suitable size GI box with modular plate
and cover in front on surface or in recess, including providing
and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and
15/16 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on
surface or in recess including providing and fixing 25 A modular socket outlet
and 25 A modular SP MCB, “C” curve including connections, painting etc. as
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete
Installation, testing and commissioning of ceiling fan, including wiring the down
17 rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, 168.0 Each 213.00 35,784.00 0.00 1.44
copper conductor, single core cable etc. as required.
18 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. 1402.0 Each 57.00 79,914.00 0.00 1.49
Installation of exhaust fan in the existing opening, including making good the
damage, connection, testing,commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all
Providing and fixing circular/ Hexagonal GI box for ceiling fan
clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet
with its top surface hacked for proper bonding, top lid shall be screwed into the
GI box by means of 3.3 mm dia round headed screws, one lock at the corners,
clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard
Supply, installation, testing & commissioning of following size Telephone KG
Krone Box with hing door and mounting accessories as required.
Supply Installation testing and commissioning of network switch or internet of
following port with all additional accessories as required.
Supply Installation Testing & Commissioning of 2U Wall Mountable powder
24 coted Rack with 3x5A Power Manager, 1 position fan, min 2 nos of shelf, Front 7.0 Each 5,439.90 0.00 38,079.27 MR
Glass door with Lock & key at respective floor.
25 Supply, installation, testing & commissioning of TV Splitter Box. 28.0 Each 861.61 0.00 24,125.00 MR
Sub Head 2 : DBs & MCBs
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution board of
sheet steel, dust protected, duly powder painted, inclusive of
2 200 A tinned copper bus bar, common neutral link, earth bar, 2.5
din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note
: Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
Digitally signed by SANJAY
Supplying and fixing following rating, four pole, 415 V, isolator
3 in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing 240/415 V, 10 kA, “C” curve, miniature circuit breaker
4 suitable for inductive load of following poles in the existing MCB DB complete 2.10
with connections, testing and commissioning etc. as required.
b 5 to 32 Amp. Double pole 28.0 Each 656.00 18,368.00 2.10.3
c 5 to 32 Amp. Triple pole and neutral 28.0 Each 1,228.00 34,384.00 2.10.5
d 63 Amp. Double pole 0.0 Each 2,722.00 0.00 2.14.3
Providing and fixing M.V. danger notice plate of 200 mm X 150
mm, made of mild steel, at least 2 mm thick, and vitreous
enameled white on both sides, and with inscription in single red colour on front
side as required.
Sub Head 3 : Surface/Recess Luminaire
Supplying installation testing and commissioning Recess Mount Downlighter
Mollis Recess Downlighter 15W LED complete in all respect.
Supplying installation testing and commissioning Recess Mount Downlighter
Mollis Recess Downlighter 18W LED complete in all respect.
3 Supplying installation testing and COVE Light LED complete in all respect. 5mtr 1175.0 mtr 137.94 1,62,083.72 MR (RA-8)
4 Supplying of 1200mm sweep ceiling fan 109.0 Each 3,226.85 3,51,726.38 MR (RA-9)
Supplying installation testing and commissioning of 450mm sweep 1500 RPM
heavy Duty Exhaust Fan .
6 Supplying installation testing and commissioning of 20W LED TUB LIGHT 63.0 Each 1,198.07 75,478.17 MR
Sub Head 1 : Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke
and salt as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories,
2 and providing masonry enclosure with cover plate having locking arrangement 16.0 Each 6,855.00 1,09,680.00 0.00 5.2
and watering pipe etc. with charcoal/coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter
below ground as strip earth electrode, including connection/
3 terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be 30.0 Meter 144.00 4,320.00 0.00 5.9
done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth
4 electrode including connection with G.I. nut, bolt, spring, washer excavation 500.0 Meter 706.00 3,53,000.00 0.00 5.11
and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in
recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for
9 connections etc. as required. 210.0 Meter 244.00 51,240.00 0.00 5.15
Sub Head 2 : Panel, Cable & End Termination
BUILDING L.T PANEL
Digitally signed by SANJAY
The Main LT Panel shall use all draw out type breakers suitable for 415 V AC, 3
phase, 50 Hz, 3 phase 4 wire supply system. The panel shall have AMF facility to
achieve electrical interlocking, synchronizing, buscoupler switching, auto
operation of incommer and bus coupler, auto start of D.G. Sets, auto D.G.
running by pre set timing, auto changeover etc and having following
incomming and outgoing Air Circuit Breakers, FSU's as per the drawing and
specification.interlocking, buscoupler switching, auto operation of incommer
1 and bus coupler, auto start of D.G. Sets, auto D.G. running by pre set timing, 1.0 Set 3,25,045.37 3,25,045.37 MR
auto changeover etc and having following incomming and outgoing Air
Circuit Breakers, FSU's as per the drawing and specification.Each incoming
breaker will have microprocessor based releases and all outgoing breaker will
have minimum electrostatic releases or mention as mention in BOQ. The Panel
will be made as per detailed specifications & drawings forming part of this
document. Fault level of panel shall be 35 MVA.
2 Nos. 160 Amp FP MCCB
1 Nos. 200 Amp TPN busbars of aluminium alloy as per SLD.
AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's.
Load Management through PLC
Contactor for Load Management System
Buscoupler switching.
4 Nos. 63 Amp TP MCB
30 Nos. 40Amp DP MCB
2 sets of multifunction meter with parameter current,voltage,KWH,KVAH,Power
factor on incoming from transformers.
2 Sets of phase indicating lights (RYB) with protection fuses (one set for each
incoming breaker).
2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming
2 Sets auto trip indicating lamp .
Note: All outgoings should have ammeter and RYB indications with backup
MCB as indicated in single line diagrams.
30 Nos. Single Phase Energy Meter
UNDER GROUND CABLES
Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded
compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC
7 inner shethed armoured with single layer of galvenized round wire or flat strip
and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of
1.1 kV grade of following size direct in ground including excavation and refilling
8 the trench etc. as required, but excluding sand cushioning and protective 7.3
b Above 35 sq. mm and upto 95 sq. mm 250.0 Meter 217.00 54,250.00 0.00 7.3.2
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of
9 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as
b Above 35 sq. mm and upto 95 sq. mm 100.0 Meter 57.00 5,700.00 0.00 7.5.2
10 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 7.6
1.1 kV grade of following size in the existing masonry open duct as required.
b Above 35 sq. mm and upto 95 sq. mm 100.0 Meter 45.00 4,500.00 0.00 7.6.2
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE
11 power cable of 1.1 kV grade of following size on cable tray as required. 7.8
a Upto 35 sq. mm (clamped with 1mm thick saddle) 330.0 Meter 63.00 20,790.00 0.00 7.6.3
b Above 35 sq. mm and upto 95 sq. mm (clamped with 25 x 3mm MS flat clamp) 50.0 Meter 63.00 3,150.00 0.00 7.6.3
END TERMINATION
Supplying and making cable end terminations with brass compression gland
and aluminium lugs for folowing sizes of 3.5 Core and 4 Core PVC insulated PVC
12 sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as
Digitally signed by SANJAY
SCHEDULE OF QUANTITIES FOR PLUMBING WORKS
RESTORATION OF SIDBI APARTMENTS, BANGALORE
INTERNAL PLUMBING WORKS
SL. DSR RATE DSR AMOUNT NDSR AMOUNT
DESCRIPTION UNIT QUANTITY
I SANITATION WORK
1 Providing and fixing white glazed earthen wate
(European type) W.C. Pan 580mm dia,(10 ltr) C.I.
Flushing Cistern complete with G.I. Pull
chain,M.S.Bracket of Engineer-in-
Charge.(Standered size)
2 Providing & fixing white vitreous china wash basin
with C.I. brackets painted white, 15 mm C.P. brass
pillar taps, C.P. brass chain with rubber plug, 32mm
C.P. brass waste of standerd pattern including
cutting & making good the walls wherever
a)White Vitreous China Wash basin size 630x450
17.7.1 mm with a pair of 15 mm C.P. brass pillar taps each 63.00 1,974.99 1,24,424.37
3 Providing and fixing white vitreous china flat back
half stall urinal of size 580*380*350mm with white
PVC automatic flushing cistern, with fittings,
standard size C.P. brass flush pipe, spreaders with
unions and clamps (all in D.P. brass) with waste
fitting as per IS : 2556, C.I. trap with outlet grating
and other couplings in C.P. brass including painting
of fittings and cutting and making good the walls
and floors wherever required:
Range of single half stall urinals with 5 litre PV.C.
17.5.1 automatic flushing cistern. each 0.00 8,792.65 0.00
4 Providing and fixing P.V.C. waste pipe for sink or
wash basin including P.V.C. waste fittings
17.28 complete.
17.28.1 Semi rigid pipe
5 Providing and fixing 600x450mm bevelled edge
mirror of superior glass (of approved quality)
complete with 6mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and
washers complete.
6 Providing and fixing Stainless Steel AISI 304 (18/8)
kitchen sink as per I.S. 13983 with C.I. brackets and
stainless steel plug 40 mm including painting of
fittings and brackets, cutting and making good the
walls wherever required :
17.10.1 Kitchen sink with drain board
7 Providing and fixing PTMT Bottle Trap for Wash basin
17.70 and sink
Bottle trap 38 mm single piece moulded with
height of 270 mm, effective length of tail pipe 260
mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing
not less than 263 gms
8 Providing and fixing PTMT towel rail complete with
brackets fixed to wooden cleats with CP brass
screws with concealed fittings arrangement of
17.73 approved quality and colour.
600 mm long towel rail with total length of 645 mm,
width 78 mm and effective height of 88 mm,
17.73.2 weighing not less than 190 gms. each 63.00 521.18 32,834.34
CP Brass fittings
9 Providing and fixing unplasticised PVC connection
18.21 pipe with brass unions
18.21.2 45 cm length
10 Providing and fixing C.P. brass bib cock of
18.49 approved quality conforming to IS:8931
11 Providing and fixing C.P. brass long body bib cock
of approved quality conforming to IS standards
18.51 and weighing not less than 690 gms.
18.51.1 a) 15 mm nominal bore each 63.00 614.98 38,743.74Digitally signed by SANJAY
12 Providing and fixing C.P. brass angle valve for basin
mixer and gyser points of approved quality
18.53 conforming to IS:8931
13 Providing and fixing C.P. brass shower rose with 15
18.22 or 20mm inlet
14 Providing and fixing C.P. brass stop cock
(concealed) of standard design and of approved
make conforming to IS:8931:
II RAIN WATER SUPPLY
1 Providing and fixing unplasticised-PVC pipe clips of
approved design to unplasticised-PVC pipes by
means of 50x50x50 mm hard wood plugs, screwed
with MS screws of required length including cutting
brick work and fixing in cement mortar 1:4 (1
cement : 4 coarse sand) and making good the
wall etc. complete.
2 Providing and laying cement concrete 1:5:10(1
cement : 5 coarse sand : 10 graded stone
aggregate 20mm nominal size) around P.V.C Soil
and waste pipe including bed concrete as per
standard design(embedded in the flooring /
3 Providing and fixing on wall face unplasticised-
Rigid PVC rain water pipes conforming to IS: 13592
Type A including jointing with seal ring conforming
to IS: 5382 leaving 10mm gap for thermal
4 Providing and fixing on wall face unplasticised PVC
moulded fittings/accessories for unplasticised Rigid
PVC rain water pipes conforming to IS:13592 Type
A including jointing with seal ring conforming to
12.42 IS:5382 leaving 10mm gap for thermal expansion.
12.42.5.2 Bend 87.5 degree
12.42.6 Shoe (Plain)
5 Providing and fixing to the inlet mouth of rain water
pipe cast iron grating 15 cm diameter and
12.44 weighing not less than 440 grams. Each 92.00 41.58 3,825.36
6 Providing and fixing unplasticised-PVC pipe clips of
approved design to unplasticised-PVC rain water
pipes by means of 50x50x50 mm hard wood plugs,
screwed with MS screws of required length
including cutting brick work and fixing in cement
mortar 1:4 (1 cement : 4 coarse sand) and making
good the wall etc. complete.
7 Making khurras 45x45 cm with average minimum
thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone
aggregate of 20 mm nominal size) over PVC sheet
1m x 1 m x 400 micron, finished with 12 mm cement
plaster 1:3 (1 cement : 3 coarse sand) and a coat
of neat cement,punning,rounding the edges and
12.22 making and finishing the outlet complete. Each 8.00 231.44 1,851.52
Digitally signed by SANJAY
III INTERNAL WATER SUPPLY
1 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot &
cold water supply including all CPVC plain & brass
threaded fittings i/c fixing the pipe with clamps at
1.00m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same
including testiang of joints complete as per
direction of Engineer in Charge.
Concealed work including cutting chases and
making good the walls etc.
18.8.3 25mm dia nominal outer dia pipes Rm. 1,260.00 543.49 6,84,797.40
18.9.6 50mm dia nominal outer dia pipes Rm. 756.00 704.78 5,32,813.68
2 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass
threaded fittings, including fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement
and testing of joints complete as per direction of
Engineer in Charge.
Internal work-Exposed on wall
18.7.2 20 mm nominal outer dia Pipes Metre 150.00 282.23 42,334.50
3 Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot &
cold water supply, including all CPVC plain & brass
threaded fittings, i/c fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the
cost of cutting chases and making good the same
including testing of joints complete as per direction
of Engineer in Charge.
Concealed work, including cutting chases and
making good the walls etc.
18.8.2 20 mm nominal outer dia Pipes Metre 945.00 446.00 4,21,470.00
4 Providing and fixing gun metal gate valve with
18.17 wheel of approved quality.
18.17.1 25mm dia nominal bore Each 23.00 462.15 10,629.45
17.17.4 50mm dia nominal bore Each 23.00 762.43 17,535.89
5 Providing and fixing brass stop cock of approved
18.16 quality.
6 Providing and placing on terrace (at all floor
levels)polyethylene water storage tank ISI : 12701
marked indicating the BIS License No. with cover
and suitable locking arrangement and making
necessary holes for inlet, outlet and over flow pipes
but without fitting and base support for tank.[Sintex,
Electroplast, Star, Lotus or equivalent having valid
ISI license]. per
Capcity in Per Liters
NON SCHEDULED ITEMS
IV SANITARY INSTALLATIONS & C.P FITTINGS
1 Providing and fixing in floor and wall face Ringfit
UPVC Conventional system for soil and waste water
pipes conforming to Type B including jointing with
seal ring. (i) Double socketed pipes.
2 Providing & fixing UPVC Floor trap of self cleansing
design with CP Jali complete in all respects.
P-Trap type Floor Trap 110 x 90 mm Nos. 86.00 274.94 23,644.97
3 NSR Providing and fixing terminal guard.
4 Providing and fixing on wall face unplasticised -
PVC moulded fittings/accessories for unplasticised
Rigid PVC pipes including jointing with seal ring
leaving 10 mm gap for thermal expansion. Digitally signed by SANJAY
Single tee with door
5 Providing and fixing C.P. brass Two-way angle
valve for EWC points & for fixing Ablution Health
Fauct of approved quality conforming to15 mm
6 NSR Providing and fixing clean out plug
7 Providing and fixing on wall face unplasticised-
Rigid PVC pipes conforming to IS: 13592 Type A
including jointing with seal ring conforming to IS:
5382 leaving 10mm gap for thermal expansion.
160mm dia Under floor Metre 40.00 1,141.51 45,660.37
8 Providing and fixing pvc Inlet fitting with 2 inlets 80 749.47
mm size fabricated from 110 mm dia PVC
pipes(approx. length=150mm to 300mm) and fixed
to PVC trap with joint and set in cement concrete
as per standard drawing complete.
NSR Each 40.00 0.00
TOTAL INTERNAL WATER SUPPLY & SANITATION WORKS [I+II+III+IV+V] 28,61,680.86 2,50,674.42
Digitally signed by SANJAY
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT Tech interior.pdf
Tender Document
BOQ BANGALORE.pdf
Tender Document
SCC.pdf
Tender Document
GCC upto amend4.pdf
Tender Document
Approved make list.pdf
Tender Document
Drawings.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
Forms.pdf
Tender Document
ADDENDUM.pdf
Tender Document
Addendum-II.pdf
Tender Document
corrigendum-1803-Corrigendum.pdf
pdf • 0.58 MB
addendum-0718f59c536c-Addendum II.pdf
pdf • 0.22 MB
corrigendum-1758-586 Corrigendum-I.pdf
pdf • 0.16 MB
addendum-71aebf470386-ADDENDUM-I.pdf
pdf • 3.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .